Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 67(5): 736-40, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19246204

RESUMEN

A low-level gamma-ray spectrometry system, based on an HPGe-detector with 92% relative efficiency recently installed in the underground laboratory Felsenkeller at 110 m water equivalent (w.e.) depth, is described. The integral background count rate normalised to the Ge-crystal mass in the energy range from 40 keV until 2.7 MeV of 0.034 s(-1)kg(-1) has been achieved by careful material selection of the detector construction material, a graded shielding construction and effective radon suppression. The detector is highly suitable for the effective surveillance of water for human consumption with decision thresholds for (226)Ra and (228)Ra in the order of some mBq L(-1).


Asunto(s)
Radón/análisis , Espectrometría gamma/instrumentación , Contaminantes Radiactivos del Agua/análisis , Humanos , Laboratorios , Espectrometría gamma/métodos , Agua/análisis
2.
J Synchrotron Radiat ; 13(Pt 4): 314-20, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16799222

RESUMEN

A Ge pixel array detector with 100 segments was applied to fluorescence X-ray absorption spectroscopy, probing the local structure of high-temperature superconducting thin-film single crystals (100 nm in thickness). Independent monitoring of pixel signals allows real-time inspection of artifacts owing to substrate diffractions. By optimizing the grazing-incidence angle theta and adjusting the azimuthal angle phi, smooth extended X-ray absorption fine structure (EXAFS) oscillations were obtained for strained (La,Sr)2CuO4 thin-film single crystals grown by molecular beam epitaxy. The results of EXAFS data analysis show that the local structure (CuO6 octahedron) in (La,Sr)2CuO4 thin films grown on LaSrAlO4 and SrTiO3 substrates is uniaxially distorted changing the tetragonality by approximately 5 x 10(-3) in accordance with the crystallographic lattice mismatch. It is demonstrated that the local structure of thin-film single crystals can be probed with high accuracy at low temperature without interference from substrates.


Asunto(s)
Algoritmos , Cristalografía/métodos , Germanio/efectos de la radiación , Cristales Líquidos/análisis , Cristales Líquidos/química , Membranas Artificiales , Procesamiento de Señales Asistido por Computador/instrumentación , Espectrometría por Rayos X/instrumentación , Espectrometría por Rayos X/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Conformación Molecular , Temperatura , Rayos X
3.
J Synchrotron Radiat ; 12(Pt 1): 57-69, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15616366

RESUMEN

This paper accounts for selected detector developments carried out over the past 15 years within the ESRF X-ray Absorption Spectroscopy group. This includes various types of photodiodes used as integrated current detectors. Special emphasis is put on the long-standing development of a Si drift-diode array suitable for energy-dispersive detection of X-ray fluorescence. This detector, which is now operational, was used to record high-quality XMCD/XAFS spectra on [Fe70Pt30] nanoparticles highly dispersed on a Si wafer. Using numerically deconvoluted spectra, energy resolution was decreased to 82 eV for the Si Kalphabeta line, 126 eV for the Fe Kalpha line and 176 eV for the Pt Lalpha line. A high-vacuum-compatible high-energy-resolution crystal analyzer was also installed on ID12, making it possible to record X-ray fluorescence excitation spectra in the photon-in/photon-out mode over a wide spectral range. Prospects of adapting these methods in order to investigate biological samples are briefly discussed.


Asunto(s)
Espectrometría de Fluorescencia/instrumentación , Análisis Espectral/instrumentación , Diseño de Equipo , Fotones , Rayos X
4.
J Synchrotron Radiat ; 5(Pt 3): 863-5, 1998 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-15263678

RESUMEN

The performance of silicon-drift-detector (SDD) arrays and digital electronics designed for X-ray absorption spectroscopy in the fluorescence excitation mode is reported. Different detectors have been manufactured and tested: two single-channel SDDs with different active areas (10 mm(2) and 1 cm(2)) and a monolithic 2 cm(2) SDD with eight readout anodes. The energy resolution varies between 160 and 170 eV FWHM. A new digital multichannel shaping amplifier has been produced. Its performance is presented in comparison with that of a standard commercial shaper.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...