Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Legal Med ; 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38861166

RESUMEN

The authors present the case of a 58-year-old man found hanging from a radiator by his shoelaces. The time of death was approximately 6 h before the body was discovered. An autopsy was performed approximately 24 h after the body was found, which revealed hemorrhages in the thoracic aorta at the junctions of the posterior intercostal arteries. Before autopsy, a routine whole-body CT scan was performed. Histologic examination of the aorta and the posterior intercostal arteries revealed a fresh hemorrhage into the tunica adventitia of the aorta. To our knowledge, there is no case description of such findings in hanged persons in the literature. Conclusion: Hemorrhages into the tunica adventitia of the junction of the posterior costal arteries may occur in association with suicidal hanging. The significance of these hemorrhages as a sign of vitality may be debated.

2.
Forensic Sci Int ; 353: 111878, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37980856

RESUMEN

BACKGROUND: A 3D sequence was introduced to unenhanced post-mortem cardiac magnetic resonance imaging (PMCMR) to enable multiplanar coronary artery image analysis and to investigate its diagnostic accuracy for the diagnosis of coronary artery stenosis and thrombosis. MATERIALS AND METHODS: N = 200 forensic cases with suspected coronary artery pathology underwent 3 Tesla PMCMR (sequence used: T2 weighted transversal 3D turbo spin echo) before autopsy. Main coronary artery stenosis and thrombosis were assessed in PMCMR by multiplanar image analysis by two observers. Coronary artery histology was determined as the gold standard and compared to PMCMR. Sensitivity, specificity, negative (NPV) and positive predictive values (PPV) with 95% confidence intervals were calculated. RESULTS: For all coronary arteries combined, sensitivity was 75% (PPV 73%) for the diagnosis of stenosis and 72% (PPV 71%) for the diagnosis of thrombosis. Specificity was 92% (NPV 90%) for correct diagnosis of non-existing stenosis and 97% (NPV 97%) for non-existing thrombosis. Sensitivity for correct diagnosis of different degrees of stenosis ranged between 67% and 80% (PPVs 67-82%); specificity ranged between 96% and 99% (NPVs 96-99%). CONCLUSION: Multiplanar PMCMR coronary artery stenosis and thrombosis assessment based on an unenhanced T2 weighted 3D sequence provide moderate sensitivity and high specificity for the diagnosis of coronary artery stenosis and/or thrombosis. Hence, 3D T2w PMCMR cannot reliably detect existing coronary artery stenosis and thrombosis but may be particularly useful for the exclusion of stenosis or thrombosis of the main coronary arteries.


Asunto(s)
Estenosis Coronaria , Trombosis , Humanos , Constricción Patológica , Sensibilidad y Especificidad , Imagen por Resonancia Magnética/métodos , Trombosis/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA