Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Appl Physiol (1985) ; 133(6): 1341-1348, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36356255

RESUMEN

Bronchial thermoplasty (BT) is a treatment for moderate-to-severe asthma in which the airway smooth muscle layer is targeted directly using thermal ablation. Although it has been shown to be safe and effective in long-term follow-up, questions remain about its mechanism of action, patient selection, and optimization of protocol based on structural phenotype. Using a cohort of 20 subjects who underwent thermoplasty and assessment by computed tomography (CT), we demonstrate that response to BT can be feasibly predicted based on pretreatment airway dimensions that inform a subject-specific computational model. Analysis revealed the need for CT assessment at total lung capacity, rather than functional residual capacity, which was less sensitive to the effects of BT. Final model predictions compared favorably with observed outcomes in terms of airway caliber and asthma control, suggesting that this approach could form the basis of improved clinical practice.NEW & NOTEWORTHY Bronchial thermoplasty is a treatment for asthma that targets the airway smooth muscle directly. We demonstrate the feasibility and constraints of predicting patient-specific response to thermoplasty using a computational model informed by pretreatment CT scans at different lung volumes. Predictions are compared with functional outcomes and posttreatment CT scans. This has the potential to form the basis for improved clinical practice.


Asunto(s)
Asma , Termoplastia Bronquial , Humanos , Termoplastia Bronquial/métodos , Selección de Paciente , Estudios de Factibilidad , Bronquios/cirugía
2.
Bone Joint Res ; 8(6): 275-287, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31346456

RESUMEN

OBJECTIVES: Our primary aim was to describe migration of the Exeter stem with a 32 mm head on highly crosslinked polyethylene and whether this is influenced by age. Our secondary aims were to assess functional outcome, satisfaction, activity, and bone mineral density (BMD) according to age. PATIENTS AND METHODS: A prospective cohort study was conducted. Patients were recruited into three age groups: less than 65 years (n = 65), 65 to 74 years (n = 68), and 75 years and older (n = 67). There were 200 patients enrolled in the study, of whom 115 were female and 85 were male, with a mean age of 69.9 years (sd 9.5, 42 to 92). They were assessed preoperatively, and at three, 12 and, 24 months postoperatively. Stem migration was assessed using Einzel-Bild-Röntgen-Analyse (EBRA). Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), EuroQol-5 domains questionnaire (EQ-5D), short form-36 questionnaire (SF-36,) and patient satisfaction were used to assess outcome. The Lower Extremity Activity Scale (LEAS), Timed Up and Go (TUG) test, and activPAL monitor (energy expelled, time lying/standing/walking and step count) were used to assess activity. The BMD was assessed in Gruen and Charnley zones. RESULTS: Mean varus/valgus tilt was -0.77° and axial subsidence was -1.20 mm. No significant difference was observed between age groups (p ⩾ 0.07). There was no difference according to age group for postoperative WOMAC (p ⩾ 0.11), HHS (p ⩾ 0.06), HOOS (p ⩾ 0.46), EQ-5D (p ⩾ 0.38), patient satisfaction (p ⩾ 0.05), or activPAL (p ⩾ 0.06). Patients 75 years and older had a worse SF-36 physical function (p = 0.01) and physical role (p = 0.03), LEAS score (p < 0.001), a shorter TUG (p = 0.01), and a lower BMD in Charnley zone 1 (p = 0.02). CONCLUSION: Exeter stem migration is within normal limits and is not influenced by age group. Functional outcome, patient satisfaction, activity level, and periprosthetic BMD are similar across all age groups.Cite this article: N. D. Clement, M. Bardgett, K. Merrie, S. Furtado, R. Bowman, D. J. Langton, D. J. Deehan, J. Holland. Cemented Exeter total hip arthroplasty with a 32 mm head on highly crosslinked polyethylene: Does age influence functional outcome, satisfaction, activity, stem migration, and periprosthetic bone mineral density? Bone Joint Res 2019;8:275-287. DOI: 10.1302/2046-3758.86.BJR-2018-0300.R1.

3.
Respir Res ; 20(1): 157, 2019 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-31311604

RESUMEN

BACKGROUND: The purpose of this study was to use CT scanning with computational fluid dynamics to evaluate the mechanisms by which Bronchial Thermoplasty (BT) improves asthmatic symptoms. METHODS: The study was conducted in a university teaching hospital, experienced in performing BT. Imaging studies were performed before, and after, BT of the left lung, and prior to treatment of the right lung, which therefore acted as a control. On each occasion, two high-resolution CT scans were performed, one at full inspiration (TLC) and the other at Functional Residual Capacity (FRC). The study protocol was offered to 10 patients, all of whom met the definition of severe asthma, despite high dose inhaled corticosteroids and dual long acting bronchodilators. RESULTS: Significant increases in airway luminal volume were observed on the treated side, compared with control, at both full inspiration (by 27%) and at FRC (by 17%). The ratio of distal airway volume to lung volume significantly increased on the treated side. The change in airway volume with inspiration from FRC increased by 48% on the treated side compared to 5% in the control lung, suggesting treatment increased airway distensibility. No effect was observed on airway wall thickness, nor air trapping. There was a trend towards correlation between the improvement in airway volume at TLC and improvement in symptoms. CONCLUSION: This study demonstrates that BT increases the luminal airway volume on the treated side compared to the control lung. We suggest that this is an important link between the airway smooth muscle atrophy demonstrated pathologically, and the improvement in symptoms observed clinically.


Asunto(s)
Asma/diagnóstico por imagen , Asma/terapia , Termoplastia Bronquial/métodos , Pulmón/diagnóstico por imagen , Pulmón/fisiología , Volumen de Ventilación Pulmonar/fisiología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mecánica Respiratoria/fisiología , Tomografía Computarizada por Rayos X/métodos
4.
Bone Joint Res ; 8(3): 146-155, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30997040

RESUMEN

OBJECTIVES: We investigated the reliability of the cobalt-chromium (CoCr) synovial joint fluid ratio (JFR) in identifying the presence of a severe aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) response and/or suboptimal taper performance (SOTP) following metal-on-metal (MoM) hip arthroplasty. We then examined the possibility that the CoCr JFR may influence the serum partitioning of Co and Cr. METHODS: For part A, we included all revision surgeries carried out at our unit with the relevant data, including volumetric wear analysis, joint fluid (JF) Co and Cr concentrations, and ALVAL grade (n = 315). Receiver operating characteristic curves were constructed to assess the reliability of the CoCr JFR in identifying severe ALVAL and/or SOTP. For part B, we included only patients with unilateral prostheses who had given matched serum and whole blood samples for Co and Cr analysis (n = 155). Multiple regression was used to examine the influence of JF concentrations on the serum partitioning of Co and Cr in the blood. RESULTS: A CoCr JFR > 1 showed a specificity of 83% (77% to 88%) and sensitivity of 63% (55% to 70%) for the detection of severe ALVAL and/or SOTP. In patients with CoCr JFRs > 1, the median blood Cr to serum Cr ratio was 0.99, compared with 0.71 in patients with CoCr JFRs < 1 (p < 0.001). Regression analysis demonstrated that the blood Cr to serum Cr value was positively associated with the JF Co concentration (p = 0.011) and inversely related to the JF Cr concentration (p < 0.001). CONCLUSION: Elevations in CoCr JFRs are associated with adverse biological (severe ALVAL) or tribocorrosive processes (SOTP). Comparison of serum Cr with blood Cr concentrations may be a useful additional clinical tool to help to identify these conditions.Cite this article: D. J. Langton, S. Natu, C. F. Harrington, J. G. Bowsher, A. V. F. Nargol. Is the synovial fluid cobalt-to-chromium ratio related to the serum partitioning of metal debris following metal-on-metal hip arthroplasty? Bone Joint Res 2019;8:146-155. DOI: 10.1302/2046-3758.83.BJR-2018-0049.R1.

5.
Bone Joint J ; 100-B(10): 1310-1319, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30295525

RESUMEN

AIMS: There are limited published data detailing the volumetric material loss from tapers of conventional metal-on-polyethylene (MoP) total hip arthroplasties (THAs). Our aim was to address this by comparing the taper wear rates measured in an explanted cohort of the widely used Exeter THA with those measured in a group of metal-on-metal (MoM) THAs. PATIENTS AND METHODS: We examined an existing retrieval database to identify all Exeter V40 and Universal MoP THAs. Volumetric wear analysis of the taper surfaces was conducted using previously validated methodology. These values were compared with those obtained from a series of MoM THAs using non-parametric statistical methodology. A number of patient and device variables were accounted for using multiple regression modelling. RESULTS: A total of 95 Exeter MoP and 249 MoM THAs were examined. The median volumetric loss from the MoM cohort was over four times larger than that from the MoP cohort (1.01 mm3 vs 0.23 mm3, p < 0.001), despite a significantly shorter median period in vivo for the MoM group (48 months vs 90 months, p < 0.001). Multiple regression modelling indicated that the dominant variables leading to greater female taper material loss were bearing diameter (p < 0.001), larger female taper angles (p < 0.001), and male titanium stem tapers (p < 0.001). CONCLUSION: Consistent with the long-term clinical success of the device, the volumetric material loss from Exeter femoral head tapers was, in general, small compared with that from larger-diameter MoM head tapers. Cite this article: Bone Joint J 2018;100-B:1310-9.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Polietileno , Falla de Prótesis , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Cabeza Femoral , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Análisis de Regresión
6.
Bone Joint Res ; 7(6): 388-396, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30034792

RESUMEN

OBJECTIVES: We have encountered patients who developed large joint fluid collections with massive elevations in chromium (Cr) and cobalt (Co) concentrations following metal-on-metal (MoM) hip arthroplasties. In some cases, retrieval analysis determined that these ion concentrations could not be explained simply by the wear rates of the components. We hypothesized that these effects may be associated with aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). PATIENTS AND METHODS: We examined the influence of the ALVAL grade on synovial fluid Co and Cr concentrations following adjustment for patient and device variables, including volumetric wear rates. Initially restricting the analysis to include only patients with one MoM hip resurfacing device, we performed multiple regression analyses of prospectively collected data. We then repeated the same statistical approach using results from a larger cohort with different MoM designs, including total hip arthroplasties. RESULTS: In the resurfacing cohort (n = 76), the statistical modelling indicated that the presence of severe ALVAL and a large fluid collection were associated with greater joint fluid Co concentrations after adjustment for volumetric wear rates (p = 0.005). These findings were replicated in the mixed implant group (n = 178), where the presence of severe ALVAL and a large fluid collection were significantly associated with greater fluid Co concentrations (p < 0.001). CONCLUSION: The development of severe ALVAL is associated with elevations in metal ion concentrations far beyond those expected from the volumetric loss from the prosthetic surfaces. This finding may aid the understanding of the sequence of events leading to soft-tissue reactions following MoM hip arthroplasties.Cite this article: D. J. Langton, R. P. Sidaginamale, T. J. Joyce, J. G. Bowsher, J. P. Holland, D. Deehan, A. V. F. Nargol, S. Natu. Aseptic lymphocyte-dominated vasculitis-associated lesions are related to changes in metal ion handling in the joint capsules of metal-on-metal hip arthroplasties. Bone Joint Res 2018;7:388-396. DOI: 10.1302/2046-3758.76.BJR-2018-0037.

7.
Clin Exp Allergy ; 48(6): 650-662, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29676834

RESUMEN

BACKGROUND: Severe asthma affects quality of life; however, its impact on workplace productivity is poorly understood. OBJECTIVE: To compare workplace productivity-absenteeism and presenteeism-and impairment in daily activities in severe and non-severe asthma over time and identify characteristics associated with presenteeism in severe asthma. METHODS: The Severe Asthma Web-based Database is an ongoing observational registry from Australia, New Zealand and Singapore. At April 2017, 434 patients with severe asthma and 102 with non-severe asthma were enrolled (18-88 years; 59% female). Participants provided comprehensive clinical and questionnaire data at baseline and were followed-up every 6 months for 24 months. Absenteeism (percentage of time not at work), presenteeism (self-reported impairment at work) and impairment in daily activities outside work due to health problems in the last week were calculated. RESULTS: At baseline, 61.4% of participants with severe asthma and 66.2% with non-severe asthma under 65 years were employed. At younger ages (30-50 years), fewer severe asthma participants were employed (69% vs 100%). Presenteeism and impairment in daily activity were more frequently reported in severe asthma and in participants with poorer asthma control, poorer lung function and more past-year exacerbations (P < .01). Over time, deteriorating asthma control was associated with increasing presenteeism. Although absenteeism was not different between severe and non-severe asthma, worse asthma control was associated with absenteeism (P < .001). In participants with severe asthma, presenteeism was reported more frequently in those with poorer asthma control, poorer asthma-related quality of life and symptoms of depression or anxiety (P < .01). CONCLUSION AND CLINICAL RELEVANCE: Severe asthma was associated with impairment at work and outside the workplace. Improving asthma control and mental health may be important targets for optimizing workplace productivity in severe asthma. Presenteeism and absenteeism may represent key metrics for assessing intervention efficacy in people with severe asthma of working age.


Asunto(s)
Absentismo , Asma/epidemiología , Eficiencia , Calidad de Vida , Lugar de Trabajo , Actividades Cotidianas , Adulto , Anciano , Asma/diagnóstico , Asma/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios
8.
Bone Joint J ; 99-B(10): 1304-1312, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28963151

RESUMEN

AIMS: We sought to determine whether cobalt-chromium alloy (CoCr) femoral stem tapers (trunnions) wear more than titanium (Ti) alloy stem tapers (trunnions) when used in a large diameter (LD) metal-on-metal (MoM) hip arthroplasty system. PATIENTS AND METHODS: We performed explant analysis using validated methodology to determine the volumetric material loss at the taper surfaces of explanted LD CoCr MoM hip arthroplasties used with either a Ti alloy (n = 28) or CoCr femoral stem (n = 21). Only 12/14 taper constructs with a rough male taper surface and a nominal included angle close to 5.666° were included. Multiple regression modelling was undertaken using taper angle, taper roughness, bearing diameter (horizontal lever arm) as independent variables. Material loss was mapped using a coordinate measuring machine, profilometry and scanning electron microscopy. RESULTS: After adjustment for other factors, CoCr stem tapers were found to have significantly greater volumetric material loss than the equivalent Ti stem tapers. CONCLUSION: When taper junction damage is identified during revision of a LD MoM hip, it should be suspected that a male taper composed of a standard CoCr alloy has sustained significant changes to the taper cone geometry which are likely to be more extensive than those affecting a Ti alloy stem. Cite this article: Bone Joint J 2017;99-B:1304-12.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Aleaciones de Cromo , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Adulto , Anciano , Anciano de 80 o más Años , Corrosión , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Microscopía Electrónica de Rastreo , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Estrés Mecánico , Propiedades de Superficie
9.
Bone Joint Res ; 6(2): 113-122, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28246095

RESUMEN

OBJECTIVES: The high revision rates of the DePuy Articular Surface Replacement (ASR) and the DePuy ASR XL (the total hip arthroplasty (THA) version) have led to questions over the viability of metal-on-metal (MoM) hip joints. Some designs of MoM hip joint do, however, have reasonable mid-term performance when implanted in appropriate patients. Investigations into the reasons for implant failure are important to offer help with the choice of implants and direction for future implant designs. One way to assess the performance of explanted hip prostheses is to measure the wear (in terms of material loss) on the joint surfaces. METHODS: In this study, a coordinate measuring machine (CMM) was used to measure the wear on five failed cementless Biomet Magnum/ReCap/ Taperloc large head MoM THAs, along with one Biomet ReCap resurfacing joint. Surface roughness measurements were also taken. The reason for revision of these implants was pain and/or adverse reaction to metal debris (ARMD) and/or elevated blood metal ion levels. RESULTS: The mean wear rate of the articulating surfaces of the heads and acetabular components of all six joints tested was found to be 6.1 mm3/year (4.1 to 7.6). The mean wear rate of the femoral head tapers of the five THAs was 0.054 mm3/year (0.021 to 0.128) with a mean maximum wear depth of 5.7 µm (4.3 to 8.5). CONCLUSION: Although the taper wear was relatively low, the wear from the articulating surfaces was sufficient to provide concern and was potentially large enough to have been the cause of failure of these joints. The authors believe that patients implanted with the ReCap system, whether the resurfacing prosthesis or the THA, should be closely monitored.Cite this article: S. C. Scholes, B. J. Hunt, V. M. Richardson, D. J. Langton, E. Smith, T. J. Joyce. Explant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint. Bone Joint Res 2017;6:113-122. DOI: 10.1302/2046-3758.62.BJR-2016-0130.R2.

10.
Bone Joint J ; 98-B(7): 925-33, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27365470

RESUMEN

AIMS: We wished to investigate the influence of metal debris exposure on the subsequent immune response and resulting soft-tissue injury following metal-on-metal (MoM) hip arthroplasty. Some reports have suggested that debris generated from the head-neck taper junction is more destructive than equivalent doses from metal bearing surfaces. PATIENTS AND METHODS: We investigated the influence of the source and volume of metal debris on chromium (Cr) and cobalt (Co) concentrations in corresponding blood and hip synovial fluid samples and the observed agglomerated particle sizes in excised tissues using multiple regression analysis of prospectively collected data. A total of 199 explanted MoM hips (177 patients; 132 hips female) were analysed to determine rates of volumetric wear at the bearing surfaces and taper junctions. RESULTS: The statistical modelling suggested that a greater source contribution of metal debris from the taper junction was associated with smaller aggregated particle sizes in the local tissues and a relative reduction of Cr ion concentrations in the corresponding synovial fluid and blood samples. Metal debris generated from taper junctions appears to be of a different morphology, composition and therefore, potentially, immunogenicity to that generated from bearing surfaces. CONCLUSION: The differences in debris arising from the taper and the articulating surfaces may provide some understanding of the increased incidence of soft-tissue reactions reported in patients implanted with MoM total hip arthroplasties compared with patients with hip resurfacings. Cite this article: Bone Joint J 2016;98-B:925-33.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cromo/análisis , Cobalto/análisis , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Líquido Sinovial/química , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tamaño de la Partícula , Estudios Prospectivos , Diseño de Prótesis , Adulto Joven
11.
Clin Exp Allergy ; 46(11): 1407-1415, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27377155

RESUMEN

BACKGROUND: Omalizumab (Xolair) dosing in severe allergic asthma is based on serum IgE and bodyweight. In Australia, patients eligible for omalizumab but exceeding recommended ranges for IgE (30-1500 IU/mL) and bodyweight (30-150 kg) may still receive a ceiling dose of 750 mg/4 weeks. About 62% of patients receiving government-subsidized omalizumab are enrolled in the Australian Xolair Registry (AXR). OBJECTIVES: To determine whether AXR participants above the recommended dosing ranges benefit from omalizumab and to compare their response to within-range participants. METHODS: Data were stratified according to dose range status (above-range or within-range). Further sub-analyses were conducted according to the reason for being above the dosing range (IgE only vs. IgE and weight). RESULTS: Data for 179 participants were analysed. About 55 (31%) were above recommended dosing criteria; other characteristics were similar to within-range participants. Above-range participants had higher baseline IgE [812 (IQR 632, 1747) IU/mL vs. 209 (IQR 134, 306) IU/mL] and received higher doses of omalizumab [750 (IQR 650, 750) mg] compared to within-range participants [450 (IQR, 300, 600) mg]. At 6 months, improvements in Juniper 5-item Asthma Control Questionnaire (ACQ-5, 3.61 down to 2.01 for above-range, 3.47 down to 1.93 for within-range, P < 0.0001 for both) and Asthma Quality of Life Questionnaire (AQLQ mean score (3.22 up to 4.41 for above-range, 3.71 up to 4.88 for within-range, P < 0.0001) were observed in both groups. Forced expiratory volume in one second (FEV1 ) improved among above-range participants. There was no difference in response between above-range and within-range participants. Above-range participants due to either IgE alone or IgE and weight had similar improvements in ACQ-5, AQLQ and FEV1 . CONCLUSIONS AND CLINICAL RELEVANCE: Patients with severe allergic asthma above recommended dosing criteria for omalizumab have significantly improved symptom control, quality of life and lung function to a similar degree to within-range participants, achieved without dose escalation above 750 mg.


Asunto(s)
Antiasmáticos/administración & dosificación , Asma/tratamiento farmacológico , Omalizumab/administración & dosificación , Adulto , Anciano , Alérgenos/inmunología , Asma/diagnóstico , Asma/inmunología , Femenino , Humanos , Inmunoglobulina E/inmunología , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
12.
Intern Med J ; 46(9): 1054-62, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27350385

RESUMEN

BACKGROUND: Severe asthma is a high impact disease. Omalizumab targets the allergic inflammatory pathway; however, effectiveness data in a population with significant comorbidities are limited. AIMS: To describe severe allergic asthma, omalizumab treatment outcomes and predictors of response among the Australian Xolair Registry participants. METHODS: A web-based post-marketing surveillance registry was established to characterise the use, effectiveness and adverse effects of omalizumab (Xolair) for severe allergic asthma. RESULTS: Participants (n = 192) (mean age 51 years, 118 female) with severe allergic asthma from 21 clinics in Australia were assessed, and 180 received omalizumab therapy. They had poor asthma control (Asthma Control Questionnaire, ACQ-5, mean score 3.56) and significant quality of life impairment (Asthma-related Quality of Life Questionnaire score 3.57), and 52% were using daily oral corticosteroid (OCS). Overall, 95% had one or more comorbidities (rhinitis 48%, obesity 45%, cardiovascular disease 23%). The omalizumab responder rate, assessed by an improvement of at least 0.5 in ACQ-5, was high at 83%. OCS use was significantly reduced. The response in participants with comorbid obesity and cardiovascular disease was similar to those without these conditions. Baseline ACQ-5 ≥ 2.0 (P = 0.002) and older age (P = 0.05) predicted the magnitude of change in ACQ-5 in response to omalizumab. Drug-related adverse events included anaphylactoid reactions (n = 4), headache (n = 2) and chest pains (n = 1). CONCLUSION: Australian patients with severe allergic asthma report a high disease burden and have extensive comorbidity. Symptomatic response to omalizumab was high despite significant comorbid disease. Omalizumab is an effective targeted therapy for severe allergic asthma with comorbidity in a real-life setting.


Asunto(s)
Antiasmáticos/administración & dosificación , Asma/tratamiento farmacológico , Omalizumab/administración & dosificación , Vigilancia de Productos Comercializados , Adolescente , Corticoesteroides/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Antiasmáticos/efectos adversos , Australia , Dolor en el Pecho/inducido químicamente , Niño , Comorbilidad , Femenino , Cefalea/inducido químicamente , Humanos , Hipersensibilidad/etiología , Modelos Lineales , Masculino , Persona de Mediana Edad , Omalizumab/efectos adversos , Calidad de Vida , Sistema de Registros , Resultado del Tratamiento , Adulto Joven
13.
Vet Rec ; 176(24): 626, 2015 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-25977404

RESUMEN

Five UK goat farms with high levels of lameness (prevalence 14-67 per cent) were investigated. On two farms (farms 1 and 2), the animals presented with typical footrot lesions. The remaining three farms (farms 3, 4 and 5) presented with infected lesions on the foot that did not resemble footrot. These lesions were observed to start from the white line or sole but the interdigital space was rarely affected. Swabs were processed by PCR to assess the presence of Dichelobacter nodosus and three specific treponeme groups (group 1: Treponema medium/Treponema vincentii-like, group 2: Treponema phagedenis-like and group 3: Treponema denticola/Treponema putidum-like) that are reported to be associated with bovine digital dermatitis and contagious ovine digital dermatitis. On farms 1 and 2, 85.7 per cent of samples were found to be positive for D nodosus while only 9.5 per cent were positive for treponeme groups 1, 2 and 3. In contrast, 5.3 per cent of samples from farms 3, 4 and 5 were positive for D nodosus, while 34.2, 68.4 and 36.8 per cent of samples from these farms tested positive for treponeme groups 1, 2 and 3, respectively. T medium/T vincentii-like, T phagedenis-like and T denticola/T putidum-like treponemes were detected on foot lesions of lame goats suggesting that they have a role in the aetiology of this lameness, which has not previously been described in dairy goats.


Asunto(s)
Úlcera del Pie/veterinaria , Enfermedades de las Cabras/microbiología , Cojera Animal/microbiología , Treponema/aislamiento & purificación , Infecciones por Treponema/veterinaria , Animales , Femenino , Panadizo Interdigital/diagnóstico , Úlcera del Pie/microbiología , Enfermedades de las Cabras/epidemiología , Cabras , Cojera Animal/epidemiología , Masculino , Treponema/clasificación , Infecciones por Treponema/microbiología , Reino Unido/epidemiología
14.
Bone Joint Res ; 3(3): 60-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24627327

RESUMEN

OBJECTIVES: Wear debris released from bearing surfaces has been shown to provoke negative immune responses in the recipient. Excessive wear has been linked to early failure of prostheses. Analysis using coordinate measuring machines (CMMs) can provide estimates of total volumetric material loss of explanted prostheses and can help to understand device failure. The accuracy of volumetric testing has been debated, with some investigators stating that only protocols involving hundreds of thousands of measurement points are sufficient. We looked to examine this assumption and to apply the findings to the clinical arena. METHODS: We examined the effects on the calculated material loss from a ceramic femoral head when different CMM scanning parameters were used. Calculated wear volumes were compared with gold standard gravimetric tests in a blinded study. RESULTS: Various scanning parameters including point pitch, maximum point to point distance, the number of scanning contours or the total number of points had no clinically relevant effect on volumetric wear calculations. Gravimetric testing showed that material loss can be calculated to provide clinically relevant degrees of accuracy. CONCLUSIONS: Prosthetic surfaces can be analysed accurately and rapidly with currently available technologies. Given these results, we believe that routine analysis of explanted hip components would be a feasible and logical extension to National Joint Registries. Cite this article: Bone Joint Res 2014;3:60-8.

15.
Bone Joint Res ; 2(5): 84-95, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23836464

RESUMEN

OBJECTIVES: The aims of this piece of work were to: 1) record the background concentrations of blood chromium (Cr) and cobalt (Co) concentrations in a large group of subjects; 2) to compare blood/serum Cr and Co concentrations with retrieved metal-on-metal (MoM) hip resurfacings; 3) to examine the distribution of Co and Cr in the serum and whole blood of patients with MoM hip arthroplasties; and 4) to further understand the partitioning of metal ions between the serum and whole blood fractions. METHODS: A total of 3042 blood samples donated to the local transfusion centre were analysed to record Co and Cr concentrations. Also, 91 hip resurfacing devices from patients who had given pre-revision blood/serum samples for metal ion analysis underwent volumetric wear assessment using a coordinate measuring machine. Linear regression analysis was carried out and receiver operating characteristic curves were constructed to assess the reliability of metal ions to identify abnormally wearing implants. The relationship between serum and whole blood concentrations of Cr and Co in 1048 patients was analysed using Bland-Altman charts. This relationship was further investigated in an in vitro study during which human blood was spiked with trivalent and hexavalent Cr, the serum then separated and the fractions analysed. RESULTS: Only one patient in the transfusion group was found to have a blood Co > 2 µg/l. Blood/Serum Cr and Co concentrations were reliable indicators of abnormal wear. Blood Co appeared to be the most useful clinical test, with a concentration of 4.5 µg/l showing sensitivity and specificity for the detection of abnormal wear of 94% and 95%, respectively. Generated metal ions tended to fill the serum compartment preferentially in vivo and this was replicated in the in vitro study when blood was spiked with trivalent Cr and bivalent Co. CONCLUSIONS: Blood/serum metal ion concentrations are reliable indicators of abnormal wear processes. Important differences exist however between elements and the blood fraction under study. Future guidelines must take these differences into account.

16.
Orthop Traumatol Surg Res ; 99(3): 263-71, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23507457

RESUMEN

INTRODUCTION: There is an ongoing debate about the optimal use of metal-on-metal (MoM) bearings in total hip replacement, since there are uncertainties about local and systemic adverse effects due to wear and corrosion of these bearings. Despite various national recommendations, efforts to achieve international harmonization of specific evidence-based recommendations for best practice are still lacking. HYPOTHESIS: An international consensus study group should be able to develop recommendations on the use and monitoring of MoM bearings, preferably at the European level, through a multidisciplinary approach, by integrating the perspectives of various stakeholders. MATERIALS AND METHODS: Twenty-one experts representing three stakeholder groups and eight countries participated in this European consensus study, which consisted of a consensus meeting, subsequent structured discussion, and consensus voting. RESULTS: The current statement defines first of all benefits, local and systemic risks, as well as uncertain issues related to MoM bearings. Safety assessment after implantation of MoM comprises all patients. A closer follow-up is recommended for large head MoM (≥36mm) and resurfacing. In these implants basic follow-up should consist of x-rays and metal ion measurement of cobalt in whole blood, performed with GF-AAS or ICP-MS. Clinical and/or radiographic abnormality as well as elevated ion levels needs additional imaging (ultrasound, CT-scan and/or MARS-MRI). Cobalt values less than 2 µg/L are probably devoid of clinical concern, the threshold value for clinical concern is expected to be within the range of 2-7 µg/L. DISCUSSION: This is the first multinational, interdisciplinary, and multiprofessional approach for developing a recommendation for the use and monitoring of MoM bearings in total hip replacement. The current recommendations are in partial agreement with previous statements regarding the extent of follow-up and imaging techniques. They however differ from previous communications regarding measurement of metal ions and especially the investigated medium, technique, and eventual threshold levels. LEVEL OF EVIDENCE: Level V, expert opinion/agreement conference.


Asunto(s)
Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Artroplastia de Reemplazo de Cadera , Cobalto , Europa (Continente) , Humanos , Osteoartritis de la Cadera/cirugía , Tamaño de la Partícula
17.
J Bone Joint Surg Br ; 94(4): 471-6, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22434461

RESUMEN

We present the clinical results and survivorship of consecutive 100 Birmingham Hip Resurfacings in 90 patients at a minimum follow-up of ten years. All procedures were carried out by an independent surgeon who commenced a prospective study in 1998. Patients were assessed clinically using the Western Ontario and McMaster Universities osteoarthritis index, Short-Form 36, Harris hip score and University of California, Los Angeles activity score. Radiological analysis was performed by an independent observer and blood metal ion levels concentrations were measured at ten years post-operatively in 62 patients. The median acetabular component inclination was 46.2° (34° to 59°) and anteversion 11.0° (0° to 30°). The median chromium concentration in the unilateral group was 1.74 (0.41 to 15.23) and for the bilateral group was 2.98 (1.57 to 18.01). The equivalent values for cobalt were 1.67 (0.54 to 20.4) and 1.88 (1.38 to 19.32). In total there were eight failures giving an overall survival at ten years of 92% (95% confidence interval (CI) 86.7 to 97.3). BHR in male patients had an improved survivorship of 94.6% (95% CI 89.4 to 100) compared with females at 84.6% (95% CI 70.7 to 98.5), but this did not reach statistical significance (p = 0.119). Four of the nine BHRs with a bearing diameter of 42 mm failed. The overall results were consistent with data produced from other centres in that the clinical outcome of large male patients was extremely encouraging, whereas the survival of the smaller joints was less satisfactory.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Metales/sangre , Osteoartritis de la Cadera/cirugía , Adulto , Anciano , Cromo/sangre , Cobalto/sangre , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Satisfacción del Paciente , Falla de Prótesis , Radiografía , Índice de Severidad de la Enfermedad , Factores Sexuales , Resultado del Tratamiento , Adulto Joven
18.
Bone Joint Res ; 1(4): 56-63, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23610672

RESUMEN

OBJECTIVES: An ongoing prospective study to investigate failing metal-on-metal hip prostheses was commenced at our centre in 2008. We report on the results of the analysis of the first consecutive 126 failed mated total hip prostheses from a single manufacturer. METHODS: Analysis was carried out using highly accurate coordinate measuring to calculate volumetric and linear rates of the articular bearing surfaces and also the surfaces of the taper junctions. The relationship between taper wear rates and a number of variables, including bearing diameter and orientation of the acetabular component, was investigated. RESULTS: The measured rates of wear and distribution of material loss from the taper surfaces appeared to show that the primary factor leading to taper failure is the increased lever arm acting on this junction in contemporary large-diameter metal-on-metal hip replacements. CONCLUSIONS: Our analysis suggests that varus stems, laterally engaging taper systems and larger head diameters all contribute to taper failure.

19.
J Psychiatr Ment Health Nurs ; 18(10): 934-42, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22074353

RESUMEN

The New to Forensic educational programme has been developed for use across all forensic services in Scotland. It is designed to meet the needs of all staff who are both new to and already working within forensic mental health services. Its objectives are targeted to both clinical and non-clinical staff. The programme follows the patient's journey through the mental health and criminal justice systems. It covers mental disorder, legislation, psychiatric defences, assessment and treatment, risk of harm to others, services, attitudes and boundaries, multidisciplinary working, users and carers, community, learning disability, and prison services. It is self-directed and practice based, and uses a problem-based approach. Over a 3-year period, trainers and mentors have been trained to deliver the programme by members of the School of Forensic Mental Health http://www.forensicnetwork.scot.nhs.uk/ and all services have adopted the programme as a core educational initiative. Initial findings from the programme evaluation indicate a significant improvement in learning following engagement in the initiative.


Asunto(s)
Psiquiatría Forense/educación , Aprendizaje Basado en Problemas/métodos , Humanos , Evaluación de Programas y Proyectos de Salud/métodos , Escocia
20.
J Bone Joint Surg Br ; 93(8): 1011-6, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21768621

RESUMEN

There is widespread concern regarding the incidence of adverse soft-tissue reactions after metal-on-metal (MoM) hip replacement. Recent National Joint Registry data have shown clear differences in the rates of failure of different designs of hip resurfacing. Our aim was to update the failure rates related to metal debris for the Articular Surface Replacement (ASR). A total of 505 of these were implanted. Kaplan-Meier analysis showed a failure rate of 25% at six years for the ASR resurfacing and of 48.8% for the ASR total hip replacement (THR). Of 257 patients with a minimum follow-up of two years, 67 (26.1%) had a serum cobalt concentration which was greater than 7 µg/l. Co-ordinate measuring machine analysis of revised components showed that all patients suffering adverse tissue reactions in the resurfacing group had abnormal wear of the bearing surfaces. Six THR patients had relatively low rates of articular wear, but were found to have considerable damage at the trunion-taper interface. Our results suggest that wear at the modular junction is an important factor in the development of adverse tissue reactions after implantation of a large-diameter MoM THR.


Asunto(s)
Prótesis de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Cromo/sangre , Cobalto/sangre , Métodos Epidemiológicos , Análisis de Falla de Equipo/métodos , Femenino , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Reoperación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...