Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Vasc Surg ; 101: 120-126, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38110085

RESUMEN

BACKGROUND: Despite the evidence of good performance, carbon dioxide (CO2) routine employment as a contrast agent for endovascular procedures is far from being adopted with its use currently limited to patients with renal impairment and known allergy to iodinated contrast medium (ICM). The purpose of our study is to evaluate the safety and effectiveness of CO2 guided endovascular abdominal aortic aneurysm repair (EVAR) in a standard population and to assess the rationale for a future widespread use. METHODS: We retrospectively collected data of every patient who underwent CO2 guided standard EVAR from September 2020 to May 2021 and compared them with the data of every patient who underwent EVAR using ICM from December 2019 to August 2020 in our unit. The selection of the contrast medium was not based on any preoperative factor as the contrast medium was routinely used in every patient in both periods. The primary end point of the study was the technical success rate. Secondary end points were the early and late complication rates, radiation exposure and renal function impairment. RESULTS: 49 patients underwent ICM guided EVAR and 52 patients underwent CO2 guided EVAR in our unit in the time frames specified above. The technical success rate was 100% in both groups with no accidental coverage of any target vessel. Intraoperative endoleaks were observed in 14% of ICM patients and 25% of CO2 patients. The radiation exposure was higher in the CO2 group if compared to the ICM group (311.48 vs. 159.86 median mGy/cm2 - P < 0.001). The incidence of postoperative acute kidney injury was low and similar in the 2 groups. No significant worsening over time of the renal function has been reported in both groups. CONCLUSIONS: EVAR can be safely performed under CO2 guidance without the integration of any quantity of ICM but with an increase in radiation exposure. The nephroprotective role of CO2 guided EVAR in a standard population is unclear and the same role in renal impaired patients should be validated with further studies on selected populations.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Insuficiencia Renal , Humanos , Medios de Contraste/efectos adversos , Dióxido de Carbono/efectos adversos , Aortografía/efectos adversos , Aortografía/métodos , Estudios Retrospectivos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Angiografía de Substracción Digital/efectos adversos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Insuficiencia Renal/etiología , Factores de Riesgo
2.
Vascular ; 30(6): 1088-1096, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34559031

RESUMEN

OBJECTIVE: This study aims to report a case series of anastomotic femoral pseudoaneurysms (PSA) treated with stent-grafting (SG) in patients at high-risk for the open surgical approach. METHODS: It is a retrospective, observational cohort study. Between 1 January 2002 and 1 April 2020, post-hoc analysis of the database including patients who received repair for femoral PSA identified those treated with SG. All but one patient were approached through a contralateral percutaneous transfemoral access, and the SG was always deployed from the common femoral artery to the profunda femoris artery. For this study, primary outcomes of interest were early (≤ 30 days) survival and patency rate. RESULTS: We identified 10/823 cases of the entire PSA cohort (1.2%). There were 9 men and 1 woman: the mean age was 76 years ± 9 (range: 64-92). Urgent intervention was performed in 4 patients. The median operative time was 30 min (IQR: 25-36). Access-related complication was never observed. In-hospital mortality occurred in 1 patient due to novel coronavirus-19-related pneumonia. Median follow-up was 24 months (IQR: 12-37); 5 patients died. At the last radiologic follow-up available, all SGs were patent without necessity of reintervention. CONCLUSION: Stent-graft repair for anastomotic femoral PSA may be considered a reasonable alternative for patients at high-risk for open surgical repair.


Asunto(s)
Aneurisma Falso , Implantación de Prótesis Vascular , COVID-19 , Procedimientos Endovasculares , Masculino , Femenino , Humanos , Anciano , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Stents/efectos adversos , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA