Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Dent J (Basel) ; 10(1)2022 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-35049610

RESUMEN

This study evaluated the influence of distal implants angulation and framework material in the stress concentration of an All-on-4 full-arch prosthesis. A full-arch implant-supported prosthesis 3D model was created with different distal implant angulations and cantilever arms (30° with 10-mm cantilever; 45° with 10-mm cantilever and 45° with 6-mm cantilever) and framework materials (Cobalt-chrome [CoCr alloy], Yttria-stabilized tetragonal zirconia polycrystal [Y-TZP] and polyetheretherketone [PEEK]). Each solid was imported to computer-aided engineering software, and tetrahedral elements formed the mesh. Material properties were assigned to each solid with isotropic and homogeneous behavior. The contacts were considered bonded. A vertical load of 200 N was applied in the distal region of the cantilever arm, and stress was evaluated in Von Misses (σVM) for prosthesis components and the Maximum (σMAX) and Minimum (σMIN) Principal Stresses for the bone. Distal implants angled in 45° with a 10-mm cantilever arm showed the highest stress concentration for all structures with higher stress magnitudes when the PEEK framework was considered. However, distal implants angled in 45° with a 6-mm cantilever arm showed promising mechanical responses with the lowest stress peaks. For the All-on-4 concept, a 45° distal implants angulation is only beneficial if it is possible to reduce the cantilever's length; otherwise, the use of 30° should be considered. Comparing with PEEK, the YTZP and CoCr concentrated stress in the framework structure, reducing the stress in the prosthetic screw.

2.
Polymers (Basel) ; 13(21)2021 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-34771387

RESUMEN

Evidence regarding the effect of the onlay preparation design for different CAD/CAM restorative materials considering the preservation of cusps is lacking. Molars were 3D-modeled in four preparation designs for onlay restoration: traditional design with functional cusp coverage (TFC), non-retentive design with functional cusp coverage (NFC), traditional design with non-functional cusp coverage (TNFC) and non-retentive design with non-functional cusp coverage (NNFC). The restorations were simulated with two CAD/CAM restorative materials: LD-lithium disilicate (IPS e.max CAD) and RC-resin composite (GrandioBloc). A 100 N axial load was applied to the occlusal surface, simulating the centric contact point. Von Mises (VM) and maximum principal (Pmax) stress were evaluated for restorations, cement layer and dental substrate. The non-retentive preparation design reduced the stress concentration in the tooth structure in comparison to the conventional retentive design. For LD onlays, the stress distribution on the restoration intaglio surface showed that the preparation design, as well as the prepared cusp, influenced the stress magnitude. The non-retentive preparation design provided better load distribution in both restorative materials and more advantageous for molar structure. The resin composite restoration on thenon-functional cusp is recommended when the functional cusp is preserved in order to associate conservative dentistry and low-stress magnitude.

3.
Dent Mater ; 37(11): 1688-1697, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34497022

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the influence of three different dental implant neck geometries, under a combined compressive/shear load using finite element analysis (FEA). The implant neck was positioned in D2 quality bone at the crestal level or 2 mm below. METHODS: One dental implant (4.2 × 9 mm) was digitized by reverse engineering techniques using micro CT and imported into Computer Aided Design (CAD) software. Non-uniform rational B-spline surfaces were reconstructed, generating a 3D volumetric model similar to the digitized implant. Three different models were generated with different implant neck configurations, namely 0°, 10° and 20°. D2 quality bone, composed of cortical and trabecular structure, was modeled using data from CT scans. The implants were included in the bone model using a Boolean operation. Two different fixture insertion depths were simulated for each implant: 2 mm below the crestal bone and exactly at the level of the crestal bone. The obtained models were imported to FEA software in STEP format. Von Mises equivalent strains were analyzed for the peri-implant D2 bone type, considering the magnitude and volume of the affected surrounding cortical and trabecular bone. The highest strain values in both cortical and trabecular tissue at the peri-implant bone interface were extracted and compared. RESULTS: All implant models were able to distribute the load at the bone-implant contact (BIC) with a similar strain pattern between the models. At the cervical region, however, differences were observed: the models with 10° and 20° implant neck configurations (Model B and C), showed a lower strain magnitude when compared to the straight neck (Model A). These values were significantly lower when the implants were situated at crestal bone levels. In the apical area, no differences in strain values were observed. SIGNIFICANCE: The implant neck configuration influenced the strain distribution and magnitude in the cortical bone and cancellous bone tissues. To reduce the strain values and improve the load dissipation in the bone tissue, implants with 10° and 20 neck configuration should be preferred instead of straight implant platforms.


Asunto(s)
Implantes Dentales , Diseño Asistido por Computadora , Análisis del Estrés Dental , Análisis de Elementos Finitos , Estrés Mecánico
4.
Am J Dent ; 34(3): 157-162, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34143586

RESUMEN

PURPOSE: To evaluate the effect of different substrate stiffness [sound dentin (SD), resin composite core (RC) or metal core (MC)] on the stress distribution of a zirconia posterior three-unit fixed partial denture (FPD). METHODS: The abutment teeth (first molar and first premolar) were modeled, containing 1.5 mm of axial reduction, and converging axial walls. A static structural analysis was performed using a finite element method and the maximum principal stress criterion to analyze the fixed partial denture (FPD) and the cement layers of both abutment teeth. The materials were considered isotropic, linear, elastic, homogeneous and with bonded contacts. An axial load (300 N) was applied to the occlusal surface of the second premolar. RESULTS: The region of the prosthetic connectors showed the highest tensile stress magnitude in the FPD structure depending on the substrate stiffness with different core materials. The highest stress peak was observed with the use of MC (116.4 MPa) compared to RC and SD. For the cement layer, RC showed the highest values in the molar abutment (14.7 MPa) and the highest values for the premolar abutment (14.4 MPa) compared to SD (14.1 and 13.4 MPa) and MC (13.8 and 13.3 MPa). Both metal core and resin composite core produced adequate stress concentration in the zirconia fixed partial denture during the load incidence. However, more flexible substrates, such as composite cores, can increase the tensile stress magnitude on the cement. CLINICAL SIGNIFICANCE: The present study shows that the choice of the cast core and metallic post by the resin composite core and fiberglass post did not improve the biomechanical behavior of the FPD. This choice must be performed based on clinical criteria (other) than mechanical.


Asunto(s)
Dentadura Parcial Fija , Circonio , Análisis del Estrés Dental , Análisis de Elementos Finitos , Estrés Mecánico
5.
Work ; 68(s1): S251-S255, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33337425

RESUMEN

BACKGROUND: Aircraft seating comfort has a significant impact on passenger on-board experience. Its assessment requires the adoption of well-designed strategies for data collection as well as appropriate data analysis methods in order to obtain accurate and reliable results. OBJECTIVES: This paper focuses on the assessment of aircraft seating comfort based on subjective comfort responses collected during laboratory experiments and taking into account seat features and passenger characteristics. METHODS: The subjective comfort evaluations have been analyzed using a model-based approach to investigate the relationship between overall seating comfort and specific seat/user characteristics. RESULTS: The results show that the overall seating comfort perception is significantly influenced by the thickness of the seat pan, the backrest position (upright or reclined), the age of the passenger and the passenger perception of being comfortably supported at the lumbar region. CONCLUSIONS: The adopted model-based approach allows the analysis of subjective seating comfort data taking into account their ordinal nature as well as the dependency between evaluations provided by the same subject.


Asunto(s)
Aeronaves , Ergonomía , Humanos , Región Lumbosacra
6.
Ergonomics ; 63(3): 324-333, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31648616

RESUMEN

This paper presents an innovative safety training method based on digital ergonomics simulations and serious games, which are games that focus on education. Digital ergonomics is intended to disseminate the culture of safety among workers, while serious games are used to train the operators on specific safety procedures and verify their skills. The results of the experimentation in a real industrial environment showed that, compared to the traditional training methodology, multimedia contents and quantitative ergonomic analyses improve the level of attention and the awareness of the workers about their own safety. However, serious games turned out to be promising training tools with regard to standard operating procedures that are usually difficult or dangerous to simulate in a real working scenario without stopping production. Practitioner summary: Digital ergonomics and serious games are used to disseminate the culture of safety among the workers and for safety training. Our results show that the proposed methodology improves the level of attention and provides a better feedback about the actual skills of the workers than the standard educational strategies. Abbreviations.


Asunto(s)
Instrucción por Computador/métodos , Ergonomía/métodos , Salud Laboral/educación , Entrenamiento Simulado/métodos , Juegos de Video , Lugar de Trabajo , Humanos
7.
Dent Mater ; 35(10): 1514-1522, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31395448

RESUMEN

OBJECTIVES: To investigate the influence of different resin composite and glass ionomer cement material combinations in a "bi-layer" versus a "single-layer" adhesive technique for class I cavity restorations in molars using numerical finite element analysis (FEA). MATERIALS AND METHODS: Three virtual restored lower molar models with class I cavities 4mm deep were created from a sound molar CAD model. A combination of an adhesive and flowable composite with bulk fill composite (model A), of a glass ionomer cement with bulk fill composite (model B) and of an adhesive with bulk fill composite (model C), were considered. Starting from CAD models, 3D-finite element (FE) models were created and analyzed. Solid food was modeled on the occlusal surface and slide-type contact elements were used between tooth surface and food. Polymerization shrinkage was simulated for the composite materials. Physiological masticatory loads were applied to these systems combined with shrinkage. Static linear analyses were carried out. The maximum normal stress criterion was adopted as a measure of potential damage. RESULTS: All models exhibited high stresses principally located along the tooth tissues-restoration interfaces. All models showed a similar stress trend along enamel-restoration interface, where stresses up to 22MPa and 19MPa was recorded in the enamel and restoration, respectively. A and C models showed a similar stress trend along the dentin-restoration interface with a lower stress level in model A, where stresses up to 11.5MPa and 7.5MPa were recorded in the dentin and restoration, respectively, whereas stresses of 17MPa and 9MPa were detected for model C. In contrast to A and C models, the model B showed a reduced stress level in dentin, in the lower restoration layer and no stress on the cavity floor. SIGNIFICANCE: FE analysis supported the positive effect of a "bi-layer" restorative technique in a 4mm deep class I cavities in lower molars versus "single-layer" bulk fill composite technique.


Asunto(s)
Cementos Dentales , Restauración Dental Permanente , Resinas Acrílicas , Resinas Compuestas , Análisis del Estrés Dental , Cementos de Ionómero Vítreo , Ensayo de Materiales , Diente Molar , Dióxido de Silicio , Estrés Mecánico
8.
Am J Dent ; 32(2): 55-60, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31094138

RESUMEN

PURPOSE: To examine the influence of different bulk and block composite and flowable and glass-ionomer material combinations in a multi-layer technique and in a unique technique, in deep Class I dental restorations. METHODS: 3D CAD of the sound tooth were built-up from a CT scan dataset using reverse engineering techniques. Four restored tooth models with Class I cavity were virtually created from a CAD model of a sound tooth. 3D-finite element (FE) models were created and analyzed starting from CAD models. Model A with flowable resin composite restoring the lower layer and bulk-fill resin composite restoring the upper layer, model B with glass-ionomer cement (GIC) restoring the lower layer and bulk-fill resin composite restoring the upper layer, model C with block composite as the only restoring material and model D with bulk-fill resin composite as the only restoring material. Polymerization shrinkage was simulated with the thermal expansion approach. Physiologic masticatory loads were applied in combination with shrinkage effect. Nodal displacements on the lower surfaces of FE models were constrained in all directions. Static linear analyses were carried out. The maximum normal stress criterion was used to assess the influence of each factor. RESULTS: Considering direct restoring techniques, models A, B and D exhibited a high stress gradient at the tooth/restorative material interface. Models A and D showed a similar stress trend along the cavity wall where a similar stress trend was recorded in the dentin and enamel. Model B showed a similar stress trend along enamel/restoration interface but a very low stress gradient along the dentin/restoration interface. Model C with a restoring block composite material showed a better response, with the lowest stress gradient at the dentin, filling block composite and enamel sides. CLINICAL SIGNIFICANCE: Bulk resin-based composite materials applied in a multilayer technique to deep and large Class I cavities produced adverse stress distributions versus block resin composite. Polymerization shrinkage and loading determined high stress levels in deep Class I cavities with bulk multi-layer restorations, while its impact on adhesion in block composite restorations was insignificant.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Preparación de la Cavidad Dental , Análisis del Estrés Dental , Análisis de Elementos Finitos , Ensayo de Materiales , Polimerizacion , Estrés Mecánico
9.
Appl Ergon ; 76: 155-163, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30642520

RESUMEN

This paper focuses on the comparative assessment of comfort and discomfort (hereafter, (dis-)comfort) for aircraft seating. Subjective and objective data of seating (dis-)comfort were collected during an experiment involving 20 volunteers who tested 3 aircraft double-seats in upright and reclined position. In order to minimize experimental uncertainty due to well-known noise factors (i.e. patterns of discomfort during the work week and during the work day, order of evaluation, inter-individual differences), experimental trials were performed according to a crossover design. Statistical data analysis aimed mainly at investigating (dis-)comfort differences across seat conditions; gender-based differences in perceived discomfort on different body parts; effect of sitting duration on perceived discomfort on different body parts. The experimental results show that differences across seat conditions impacted differently on perceived discomfort depending on gender, body parts and sitting duration. No significant differences in perceived discomfort across gender were evident for the lightweight seat in both upright and reclined positions. On the contrary, for both baseline configurations, perceived discomfort at head and neck areas was higher for males than for females. For all seat conditions, participants experienced a significant worsening of perceived comfort over time at shoulders, back, sacrum and thighs and, in addition, at upper body area (i.e. neck, arm and forearm) and knees only for seats in reclined position.


Asunto(s)
Aeronaves , Diseño de Equipo , Diseño Interior y Mobiliario , Adulto , Dorso , Comportamiento del Consumidor , Estudios Cruzados , Femenino , Cabeza , Humanos , Rodilla , Masculino , Cuello , Percepción , Proyectos de Investigación , Factores Sexuales , Muslo , Factores de Tiempo , Extremidad Superior , Adulto Joven
10.
Dent Mater ; 34(7): 1063-1071, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29703402

RESUMEN

OBJECTIVES: To assess conceptual designs of dental posts consisting of polyetherimide (PEI) reinforced with carbon (C) and glass (G) glass fibers in endodontically treated anterior teeth. METHODS: 3D tessellated CAD and geometric models of endodontically treated anterior teeth were generated from Micro-CT scan images. Model C-G/PEI composite posts with different Young's moduli were analyzed by Finite Element (FE) methods post A (57.7GPa), post B (31.6GPa), post C (from 57.7 to 9.0GPa in the coronal-apical direction). A load of 50N was applied at 45° to the longitudinal axis of the tooth, acting on the palatal surface of the crown. The maximum principal stress distribution was determined along the post and at the interface between the post and the surrounding structure. RESULTS: Post C, with Young's modulus decreasing from 57.7 to 9.0GPa in the coronal-apical direction, reduced the maximum principal stress distribution in the restored tooth. Post C gave reduced stress and the most uniform stress distribution with no stress concentration, compared to the other C-G/PEI composite posts. SIGNIFICANCE: The FE analysis confirmed the ability of the functionally graded post to dissipate stress from the coronal to the apical end. Hence actual (physical) C-G/PEI posts could permit optimization of stress distributions in endodontically treated anterior teeth.


Asunto(s)
Resinas Compuestas/química , Polímeros/química , Técnica de Perno Muñón , Diente no Vital , Fibra de Carbono/química , Diseño Asistido por Computadora , Materiales Dentales/química , Diseño de Prótesis Dental , Análisis del Estrés Dental , Módulo de Elasticidad , Análisis de Elementos Finitos , Vidrio/química , Humanos , Imagenología Tridimensional , Técnicas In Vitro , Microtomografía por Rayos X
11.
Dent Mater ; 33(12): 1466-1472, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29126633

RESUMEN

OBJECTIVE: To assess the effect of a ferrule design with specific post material-shape combinations on the mechanical behavior of post-restored canine teeth. METHODS: Micro-CT scan images of an intact canine were used to create a 3-D tessellated CAD model, from which the shapes of dentin, pulp and enamel were obtained and geometric models of post-endodontically restored teeth were created. Two types of 15mm post were evaluated: a quartz fiber post with conical-tapered shape, and a carbon (C) fiber post with conical-cylindrical shape. The abutment was created around the coronal portion of the posts and 0.1mm cement was added between prepared crown and abutment. Cement was also added between the post and root canal and a 0.25mm periodontal ligament was modeled around the root. Four models were analysed by Finite Element (FE) Analysis: with/without a ferrule for both types of post material and shape. A load of 50N was applied at 45° to the longitudinal axis of the tooth, acting on the palatal surface of the crown. The maximum normal stress criterion was adopted as a measure of potential damage. RESULTS: Models without a ferrule showed greater stresses (16.3MPa) than those for models with a ferrule (9.2MPa). With a ferrule, stress was uniformly distributed along the abutment and the root, with no critical stress concentration. In all models, the highest stresses were in the palatal wall of the root. Models with the C-fiber post had higher stress than models with the quartz fiber posts. The most uniform stress distribution was with the combination of ferrule and quartz fiber post. SIGNIFICANCE: The FE analysis confirmed a beneficial ferrule effect with the combination of ferrule and quartz fiber post, with tapered shape, affording no critical stress concentrations within the restored system.


Asunto(s)
Coronas , Diente Canino/fisiología , Tratamiento del Conducto Radicular , Diente no Vital/fisiopatología , Diseño Asistido por Computadora , Diente Canino/diagnóstico por imagen , Pilares Dentales , Materiales Dentales/química , Diseño de Prótesis Dental , Análisis de Elementos Finitos , Humanos , Imagenología Tridimensional , Ensayo de Materiales , Técnica de Perno Muñón , Diente no Vital/diagnóstico por imagen , Microtomografía por Rayos X
12.
Dent Mater ; 33(12): 1456-1465, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29128128

RESUMEN

OBJECTIVES: To investigate the influence of specific resin-composite, glass ceramic and glass ionomer cement (GIC) material combinations in a "multi-layer" technique to replace enamel and dentin in class II mesio-occlusal-distal (MOD) dental restorations using 3D-Finite Element Analysis (FEA). METHODS: Four 3D-FE models (A-D) of teeth, adhesively restored with different filling materials, were created and analyzed in comparison with a 3D model (E) of a sound lower molar. Models A, B & C had "multilayer" constructions, consisting of three layers: adhesive, dentin replacement and enamel replacement. Model A: had a low modulus (8GPa) composite replacing dentin and a higher modulus (12GPa) composite replacing enamel. Model B: had a GI cement replacing dentin and a higher modulus (12GPa) composite replacing enamel. Model C: had a low modulus (8GPa) composite replacing dentin and a very high modulus (70GPa) inlay replacing enamel. Model D: had a lithium disilicate inlay replacing both dentin and enamel with a luting cement base-layer. Polymerization shrinkage effects were simulated and a load of 600N was applied. All the materials were assumed to behave elastically throughout the entire deformation. RESULTS: Model A showed the highest stress distribution along all the adhesive interfaces of the shrinking resin-based materials with a critical condition and failure risk marginally and internally. Model D, by contrast, showed a more favorable performance than either of the multilayer groups (A-C). Stress and displacement plots showed an elastic response similar to that obtained for the sound tooth model. Model B and Model C performed according to their bilayer material properties. The use of a non-shrink dentin component simulating a GIC clearly affected the shrinkage stress at the basis of the Model B; while the bulk resin composite having a 12GPa Young's modulus and linear polymerization shrinkage of 1% strongly influenced the biomechanical response in the bucco-lingual direction. SIGNIFICANCE: Direct resin-based composite materials applied in multilayer techniques to large class II cavities, with or without shrinking dentin layers, produced adverse FEA stress distributions and displacements. An indirect lithium disilicate inlay used to replace lost dentin and enamel in posterior restored teeth generated lower stress levels, within the limits of the elastic FEA model.


Asunto(s)
Cerámica/química , Resinas Compuestas/química , Materiales Dentales/química , Restauración Dental Permanente/métodos , Cementos de Ionómero Vítreo/química , Simulación por Computador , Diseño Asistido por Computadora , Análisis del Estrés Dental , Análisis de Elementos Finitos , Humanos , Ensayo de Materiales , Diente Molar , Microtomografía por Rayos X
13.
Materials (Basel) ; 10(2)2017 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-28772505

RESUMEN

A statistical approach for the characterization of Additive Manufacturing (AM) processes is presented in this paper. Design of Experiments (DOE) and ANalysis of VAriance (ANOVA), both based on Nested Effects Modeling (NEM) technique, are adopted to assess the effect of different laser exposure strategies on physical and mechanical properties of AlSi10Mg parts produced by Direct Metal Laser Sintering (DMLS). Due to the wide industrial interest in AM technologies in many different fields, it is extremely important to ensure high parts performances and productivity. For this aim, the present paper focuses on the evaluation of tensile properties of specimens built with different laser exposure strategies. Two optimal laser parameters settings, in terms of both process quality (part performances) and productivity (part build rate), are identified.

14.
Dent Mater ; 33(6): 690-701, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28413061

RESUMEN

OBJECTIVES: To study the influence of resin based and lithium disilicate materials on the stress and strain distributions in adhesive class II mesio-occlusal-distal (MOD) restorations using numerical finite element analysis (FEA). To investigate the materials combinations in the restored teeth during mastication and their ability to relieve stresses. METHODS: One 3D model of a sound lower molar and three 3D class II MOD cavity models with 95° cavity-margin-angle shapes were modelled. Different material combinations were simulated: model A, with a 10µm thick resin bonding layer and a resin composite bulk filling material; model B, with a 70µm resin cement with an indirect CAD-CAM resin composite inlay; model C, with a 70µm thick resin cement with an indirect lithium disilicate machinable inlay. To simulate polymerization shrinkage effects in the adhesive layers and bulk fill composite, the thermal expansion approach was used. Shell elements were employed for representing the adhesive layers. 3D solid CTETRA elements with four grid points were employed for modelling the food bolus and tooth. Slide-type contact elements were used between the tooth surface and food. A vertical occlusal load of 600 N was applied, and nodal displacements on the bottom cutting surfaces were constrained in all directions. All the materials were assumed to be isotropic and elastic and a static linear analysis was performed. RESULTS: Displacements were different in models A, B and C. Polymerization shrinkage hardly affected model A and mastication only partially affected mechanical behavior. Shrinkage stress peaks were mainly located marginally along the enamel-restoration interface at occlusal and mesio-distal sites. However, at the internal dentinal walls, stress distributions were critical with the highest maximum stresses concentrated in the proximal boxes. In models B and C, shrinkage stress was only produced by the 70µm thick resin layer, but the magnitudes depended on the Young's modulus (E) of the inlay materials. Model B mastication behavior (with E=20GPa) was similar to the sound tooth stress relief pattern. Model B internally showed differences from the sound tooth model but reduced maximum stresses than model A and partially than model C. Model C (with E=70GPa) behaved similarly to model B with well redistributed stresses at the occlusal margins and the lateral sides with higher stress concentrations in the proximal boxes. Models B and C showed a more favorable performance than model A with elastic biomechanics similar to the sound tooth model. SIGNIFICANCE: Bulk filling resin composite with 1% linear polymerization shrinkage negatively affected the mechanical behavior of class II MOD restored teeth. Class II MOD direct resin composite showed greater potential for damage because of higher internal and marginal stress evolution during resin polymerization shrinkage. With a large class II MOD cavity an indirect composite or a lithium disilicate inlay restoration may provide a mechanical response close to that of a sound tooth.


Asunto(s)
Porcelana Dental , Restauración Dental Permanente , Resinas Compuestas , Análisis de Elementos Finitos , Ensayo de Materiales , Estrés Mecánico
15.
Dent Mater ; 33(1): e39-e47, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27890355

RESUMEN

OBJECTIVE: To study the influence of the different class II mesio-occlusal-distal (MOD) cavity shape on the stress and strain distributions in adhesive indirect restorations, using numerical finite element analysis (FEA). To investigate the relationship between restored teeth failure and stiffness of food, three values of Young's modulus were used for the food. METHODS: A 3D model of a sound lower molar and three class II MOD cavities with different shape were created. Slide-type contact elements were used between tooth surface and food. An adhesive resin-based cement, modeled with fixed-type contact elements, and a single restorative filling materials were considered. To simulate polymerization shrinkage effect, which is basically restricted to the thin composite cement layer, shell elements were employed and the thermal expansion approach was used. A vertical occlusal load of 600N was applied, while assigning fixed zero-displacements on the cutting surfaces below the crevices. All the materials were assumed to be isotropic and elastic. A static linear analysis was carried out. RESULTS: In the lingual cusp, the displacements increased as the values of the stiffness food increased. In the restored teeth, the stress near the restoration-tooth interface was strongly dependent on the MOD cavity shape. The stress peaks were mainly located along the enamel-dentin interface at the lingual side; wedge-shaped MOD cavity with a low angle, in combination with the lowest food stiffness provided the best results. SIGNIFICANCE: A more complex load application on the occlusal surfaces was introduced. Food stiffness slightly affected the stress distribution of the restored and sound teeth. Teeth with adhesive class II MOD indirect resin composite restorations were potentially more susceptible to damage if the class II MOD cavity-margin-angle was higher than 95°. Restored teeth with a higher cavity-margin-angle led to considerable stress concentration in the lingual cusp along the enamel-dentin interface. These models were more susceptible to fracture in the lingual cusps when compared to the buccal ones.


Asunto(s)
Preparación de la Cavidad Dental , Restauración Dental Permanente , Análisis del Estrés Dental , Resinas Compuestas , Materiales Dentales , Análisis de Elementos Finitos , Cementos de Resina , Estrés Mecánico
16.
Med Eng Phys ; 35(1): 36-46, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22475566

RESUMEN

It was reported that next to style, comfort is the second key aspect in purchasing footwear. One of the most important components of footwear is the shoe sole, whose design is based on many factors such as foot shape/size, perceived comfort and materials. The present paper focuses on the parametric analysis of a shoe sole to improve the perceived comfort. The sensitivity of geometric and material design factors on comfort degree was investigated by combining real experimental tests and CAD-FEM simulations. The correlation between perceived comfort and physical responses, such as plantar pressures, was estimated by conducting real tests. Four different conditions were analyzed: subjects wearing three commercially available shoes and in a barefoot condition. For each condition, subjects expressed their perceived comfort score. By adopting plantar sensors, the plantar pressures were also monitored. Once given such a correlation, a parametric FEM model of the footwear was developed. In order to better simulate contact at the plantar surface, a detailed FEM model of the foot was also generated from CT scan images. Lastly, a fractional factorial design array was applied to study the sensitivity of different sets of design factors on comfort degree. The findings of this research showed that the sole thickness and its material highly influence perceived comfort. In particular, softer materials and thicker soles contribute to increasing the degree of comfort.


Asunto(s)
Diseño Asistido por Computadora , Análisis de Elementos Finitos , Zapatos , Adolescente , Adulto , Femenino , Humanos , Masculino , Percepción , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...