Environ Health Perspect ; 108(4): 323-8, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10753090

RESUMEN

We developed a sensitive and accurate analytical method for quantifying methyleugenol (ME) in human serum. Our method uses a simple solid-phase extraction followed by a highly specific analysis using isotope dilution gas chromatography-high resolution mass spectrometry. Our method is very accurate; its limit of detection is 3.1 pg/g and its average coefficient of variation is 14% over a 200-pg/g range. We applied this method to measure serum ME concentrations in adults in the general U.S. population. ME was detected in 98% of our samples, with a mean ME concentration of 24 pg/g (range < 3.1-390 pg/g). Lipid adjustment of the data did not alter the distribution. Bivariate and multivariate analyses using selected demographic variables showed only marginal relationships between race/ethnicity and sex/fasting status with serum ME concentrations. Although no demographic variable was a good predictor of ME exposure or dose, our data indicate prevalent exposure of U.S. adults to ME. Detailed pharmacokinetic studies are required to determine the relationship between ME intake and human serum ME concentrations.


Asunto(s)
Carcinógenos/análisis , Eugenol/análogos & derivados , Espectrometría de Masas/métodos , Adolescente , Adulto , Anciano , Exposición a Riesgos Ambientales , Eugenol/sangre , Femenino , Humanos , Masculino , Espectrometría de Masas/normas , Persona de Mediana Edad , Valores de Referencia , Sensibilidad y Especificidad , Estados Unidos
2.
Sci Total Environ ; 144(1-3): 153-77, 1994 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-8209226

RESUMEN

We measured the residues of polychlorinated biphenyls (PCBs) in the serum of 23 residents of the New Bedford, Massachusetts, area and from two homogenates each of bluefish and lobsters from the same area. We used congener-specific and total Aroclor quantitative approaches, both of which involved gas chromatography with electron capture detection. Using gas chromatography mass spectrometry (electron ionization mode), we confirmed the presence of PCBs in the combined serum samples and in the aliquots of bluefish and lobsters. In measuring the PCB levels in serum, we found good agreement between the two electron capture detector approaches (r > or = 0.97) when the serum of specific congeners was compared to total Aroclor. We used univariate and multivariate quality control approaches to monitor these analyses. Analytical results for bluefish showed a better agreement between the two techniques than did those for lobsters; however, the small number of samples precluded any statistical comparison. We also measured levels of chlorinated pesticides in the serum samples of two groups of New Bedford residents, those with low PCB levels (< 15 ng/ml) and those with high PCB levels (> or = 15 ng/ml). We found that residents with high PCB levels also tended to have higher levels of hexachlorobenzene (HCB) and 1,1-dichloro-2,2-di-(p-chlorophenyl) ethylene (p,p'-DDE). The higher concentration of all three analytes appears to be influenced by employment in the capacitor industry, by seafood consumption, or both. Using Jaccard measures of similarity and principal component analysis we compared the gas chromatographic patterns of PCBs found in the serum of New Bedford area residents with high serum PCBs with the patterns found in homogenates of lobsters (inclusive of all edible portions except the roe), in homogenates of bluefish fillets taken from local waters, and in serum from goats fed selected technical Aroclors (e.g. Aroclors 1016, 1242, 1254, or 1260). The patterns found in human serum samples were similar to the patterns found in lobster homogenates. Both of these patterns closely resembled patterns found in the serum samples of the goat fed aroclor 1254, as demonstrated by both pattern recognition techniques. In addition, the chromatographic patterns of human serum and of lobsters and bluefish homogenates all indicated the presence of PCBs more characteristic of Aroclors 1016 or 1242.


Asunto(s)
Peces , Contaminación de Alimentos/análisis , Nephropidae/química , Bifenilos Policlorados/análisis , Análisis de Varianza , Animales , Cromatografía de Gases/métodos , Humanos , Insecticidas/análisis , Massachusetts , Bifenilos Policlorados/administración & dosificación , Bifenilos Policlorados/sangre , Control de Calidad , Encuestas y Cuestionarios
3.
J Assoc Off Anal Chem ; 74(4): 577-86, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1917803

RESUMEN

The present study uses gas liquid chromatography (GLC) electron capture detection with packed and capillary columns to detect polychlorinated biphenyls (PCBs) in serum samples from people living near the electric car repair and maintenance facility of the Southeastern Pennsylvania Transit Authority in Paoli, Pennsylvania. Most of the cohort surveyed had serum patterns similar to patterns for Aroclor 1260 (AR 1260); a small portion (3/89) had patterns indicative of an AR with higher chlorination (e.g., AR 1268). In addition to analyzing serum samples from humans, we also analyzed serum samples from canines (pets of some of the subjects). In general, the serum pattern for canines was less descriptive for AR 1260 than the pattern for humans; however, the pattern for several canines (9/16) was that of the higher chlorinated PCBs (e.g., AR 1268). By using mass spectrometry and capillary column GLC, we confirmed the presence of high molecular weight polychlorinated congeners in both human and animal samples. We were not able to show a statistically significant relationship between serum patterns of PCBs in canines and their owners or between canines and certain behavioral traits (e.g., runs free, retrieves, hours outside, hours inside). However, the correlation between PCBs quantified as AR 1268 and canines' residence time was statistically significant.


Asunto(s)
Bifenilos Policlorados/sangre , Animales , Cromatografía de Gases/métodos , Cromatografía Liquida/métodos , Estudios de Cohortes , Perros , Exposición a Riesgos Ambientales , Estudios de Evaluación como Asunto , Cromatografía de Gases y Espectrometría de Masas , Humanos , Pennsylvania
4.
Analyst ; 115(3): 243-51, 1990 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-2109552

RESUMEN

Serum for reference pools of in vivo polychlorinated biphenyls (PCBs) was obtained from four goats that had received one dose (100 mg kg-1) of a selected technical Aroclor (AR) (1016, 1242, 1254 or 1260) and were allowed to recover for 30 d. These pools were used to assess the differences in an analytical method that determines and quantifies PCBs using packed-column gas chromatography (PCGC) (quantified on the basis of mean mass percent. data for grouped PCB peaks) and capillary-column gas chromatography (CCGC) (quantified on the basis of percent. composition data for specific congeners). With CCGC, results were statistically significantly different (p less than or equal to 0.0002) from results with PCGC for ARs 1016, 1242 and 1254 but not for AR 1260 (p = 0.23). When comparing these gas chromatographic methods using bovine serum spiked in vitro with the same ARs at 17-25 p.p.b., it was found that the methods were not statistically significantly different for any of the ARs (p = 0.30-0.92). Levels of serum PCB determined by the two methods for 12 persons, divided into two groups according to exposure, were compared using the paired t-test. Group 1 consisted of three persons with dietary and/or environmental exposure; one with dietary and/or environmental exposure in addition to occupational exposure dating back 20 years. Group 2 consisted of eight persons with recent occupational exposure.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Cromatografía de Gases/normas , Cabras/sangre , Bifenilos Policlorados/sangre , Animales , Arocloros/sangre , Bovinos , Cromatografía de Gases/métodos , Exposición a Riesgos Ambientales , Humanos , Control de Calidad , Estándares de Referencia
5.
J Assoc Off Anal Chem ; 72(4): 649-59, 1989.
Artículo en Inglés | MEDLINE | ID: mdl-2547752

RESUMEN

A gas chromatographic-electron capture detection method for determining the concentration of polychlorinated biphenyls (PCBs) as Aroclor 1254 (AR 1254) in serum was evaluated through a 2-phase collaborative study. In Phase I, each collaborator's lot of Woelm silica gel (70-150 mesh) was evaluated for elution and recovery of AR 1254, which had been added in vitro at 25 ng/mL to a serum extract. In Phase II, each collaborator analyzed a series of bovine serum samples that contained the following: (1) in vitro-spiked AR 1254; (2) in vivo AR 1254 and 8 in vitro-spiked chlorinated hydrocarbons; (3) in vivo AR 1254 only; (4) 8 in vitro-spiked chlorinated hydrocarbons only; and (5) neither AR 1254 nor chlorinated hydrocarbons above the detection limit of the method. In Phase I, the average recovery of AR 1254 from silica gel for the 6 collaborators was 87.9 +/- 15.44% (mean +/- 1 SD; N = 18; range = 52.3-105.8%). In Phase II, the analysis of in vitro spikes of AR 1254 in serum at 8.58, 16.8, 41.8, and 84.3 ppb gave mean (means) interlaboratory recoveries of 89.0, 83.3, 79.4, and 76.9%, respectively, with within-laboratory (repeatability) relative standard deviations (RSDr) of 18.8, 20.5, 10.2, and 14.1%, respectively, and among-laboratory (reproducibility) relative standard deviations (RSDR) of 21.5, 21.1, 14.6, and 20.8%, respectively. The determination of in vivo AR 1254 in samples containing approximately 10, 25, 50, and 100 ng/mL of AR 1254 resulted in interlaboratory means of 10, 22, 39, and 79 ng/mL, respectively, with RSDr = 6.7, 9.7, 6.4, and 5.8%, respectively, and RSDR = 20.6, 16.0, 10.9, and 10.3%, respectively. The precision of the method for incurred AR 1254 showed a maximum RSDr of less than 10% and a maximum RSDR of less than 21% for a concentration range of 10-100 ng/mL. The accuracy of the method as demonstrated by the mean recovery of in vitro-spiked AR 1254 over a concentration range of 8.58-843 ng/mL was 82.2%. The method has been approved interim official first action.


Asunto(s)
Arocloros/sangre , Bifenilos Policlorados/sangre , Animales , Bovinos , Cromatografía de Gases , Indicadores y Reactivos , Gel de Sílice , Dióxido de Silicio , Sulfatos
9.
J Anal Toxicol ; 7(6): 279-82, 1983.
Artículo en Inglés | MEDLINE | ID: mdl-6319819

RESUMEN

An interlaboratory quality assurance program was designed and implemented for the analysis of serum for polychlorinated biphenyls (PCBs) and polybrominated biphenyls (PBBs). The two primary means of quality control were analysis of known and blind quality control samples and analysis of blind duplicate serum samples.


Asunto(s)
Bifenilos Polibrominados/sangre , Bifenilos Policlorados/sangre , Cromatografía de Gases/métodos , Humanos , Laboratorios/normas , Control de Calidad
10.
J Assoc Off Anal Chem ; 66(4): 956-68, 1983 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-6411677

RESUMEN

Forty-four laboratories participated in evaluation of a method for determining polychlorinated biphenyls (PCBs) as AR 1254 in serum at the parts per billion level. The method involves deproteinating serum with methanol, extracting with hexane-ethyl ether, and eluting PCBs from deactivated silica gel for gas-liquid chromatographic determination with electron capture detection. Compounds are quantitated by using the Webb-McCall factors. Five serum pools, 4 containing in vivo-fortified PCBs (as AR 1254) or 8 in vitro-fortified chlorinated hydrocarbons (CHs), or both, were used. For PCB fortification levels of 9.89 (EP 2), 24.74 (EP 3), and 74.20 ppb (EP 4), interlaboratory coefficients of variation (CVs) for collaborators that adhered to protocol were 92.7, 67.6, and 25.8%, respectively. CVs on the same pools analyzed by the Centers for Disease Control (CDC) were 7.4, 7.8, and 4.6%, respectively. Average interlaboratory recoveries for pools EP 2, EP 3, and EP 4 were 138.1, 111.2, and 91.1%, respectively, and 99.8, 89.6, and 90.4%, respectively, for CDC on the same pools. There was a general decrease in the mean error for those laboratories that had participated in an earlier study in which they were allowed to use their own methods.


Asunto(s)
Bifenilos Policlorados/sangre , Animales , Bovinos , Fenómenos Químicos , Química , Cromatografía de Gases/métodos
11.
J Assoc Off Anal Chem ; 66(1): 32-9, 1983 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-6402483

RESUMEN

A method is proposed for concurrently determining the levels of multiple intact exogenous compounds in serum, particularly polychlorinated biphenyls (PCBs) as Aroclor (AR) 1254 and chlorinated hydrocarbons (CHs). Bovine serum pools containing in vivo-bound PCBs (as AR 1254) and in vitro-spiked CHs are used to evaluate the method, which encompasses serum denaturation with methanol, mixed solvent extraction, multiple solvent fractionation from activated silica gel, and determination by electron capture gas-liquid chromatography. Mean recoveries of the in vitro-spiked 9 CHs at levels of 2.0-29.1 ppb ranged from 52.8 to 98.4% from trial environmental pools; mean recoveries of the in vivo-bound PCBs (as AR 1254) were 114.1 and 92.6% at levels of 10 and 50 ppb, respectively.


Asunto(s)
Hidrocarburos Clorados/sangre , Bifenilos Policlorados/sangre , Animales , Arocloros/sangre , Bovinos , Cromatografía de Gases
12.
J Assoc Off Anal Chem ; 66(1): 40-5, 1983 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-6402484

RESUMEN

Twenty-five laboratories participated in a study to determine the levels of polychlorinated biphenyls (PCBs) in 3 bovine serum pools, referred to as trial environmental pools (TEPs). TEPs 2 and 3 contained, respectively, low (9.97 ppb) and high (49.64 ppb) levels of PCBs (as in vivo-bound Aroclor 1254) and the same level of 9 commonly occurring chlorinated hydrocarbons. TEP 1 contained only naturally occurring levels of these analytes. Laboratories analyzed each sample in duplicate by the method used in their laboratory for measuring PCBs in blood serum. The coefficients of variation (CV) for the 12 laboratories reporting quantitative data and the required number of analyses for TEP 2 and TEP 3 were 37.0 and 30.7%, respectively. The mean recoveries for these 12 laboratories were 239.3 and 165.4% for TEP 2 and TEP 3, respectively. Three laboratories reported data with mean values for TEP 2 and TEP 3 within +/- 3 standard deviations of the CDC characterized mean. Their coefficients of variation were 12.4 and 18.8% for TEP 2 and TEP 3, respectively. The mean recoveries for these 3 laboratories were 150.7 and 98.4% for TEP 2 and TEP 3, respectively. Our most significant observations were the laboratories' failure to separate PCBs from DDTs and the excessive background of the reagent blanks. The widely discrepant results indicate a definite need to standardize methodology for this analysis.