Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Endosc Ultrasound ; 12(3): 319-325, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37693112

RESUMEN

Background and Objectives: Several types of needles are available for EUS-guided tissue sampling of pancreatic lesions. Whereas fine-needle aspiration (FNA) needles typically provide cytological samples, fine-needle biopsy (FNB) needles are designed to obtain microcores with preserved tissue architecture. The aim of this study was to compare tissue amount and diagnostic yield between a modified Franseen-type FNB needle (TopGain; Medi-Globe GmbH, Grassau, Germany) and a standard FNA needle. Methods: We performed a prospective, multicenter randomized controlled study between June 2020 and September 2021, including patients with a solid pancreatic lesion referred for EUS-guided tissue sampling at 3 centers in Denmark. The patients were randomized 1:1 to either FNA needle or the novel FNB needle. Primary outcomes included the number of obtained tissue microcores and total and diagnostic tissue area. Results: Sixty-four patients were included. The median number of tissue microcores procured per pass was significantly higher in the FNB group compared with FNA (3 vs. 2, P < 0.001). Similarly, the mean total tissue area (2.74 vs. 0.44 mm2, P < 0.001) and mean diagnostic tissue area (1.74 vs. 0.28 mm2, P < 0.001) were more than 6-fold larger in the FNB samples compared with FNA. The median number of passes needed for a diagnostic sample was 1 for the FNB needle and 2 for FNA needle (P = 0.12). The novel FNB needle provided a higher percentage of samples of excellent quality (P = 0.002). Conclusions: The novel Franseen-type FNB needle seems to be significantly superior to a conventional FNA needle. The results of this study underline excellent performance of crown-cut needles.

2.
Ann Surg ; 275(5): 911-918, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33605581

RESUMEN

OBJECTIVE: To describe the pooled learning curves of Ivor Lewis totally minimally invasive esophagectomy (TMIE) in hospitals stratified by predefined hospital- and surgeon-related factors. BACKGROUND: Ivor Lewis (TMIE is known to have a long learning curve which is associated with considerable learning associated morbidity. It is unknown whether hospital and surgeon characteristics are associated with more efficient learning. METHODS: A retrospective analysis of prospectively collected data of consecutive Ivor Lewis TMIE patients in 14 European hospitals was performed. Outcome parameters used as proxy for efficient learning were learning curve length, learning associated morbidity, and the plateau level regarding anastomotic leakage and textbook outcome. Pooled incidences were plotted for the factor-based subgroups using generalized additive models and 2-phase models. Casemix predicted outcomes were plotted and compared with observed outcomes. The investigated factors included annual volume, TMIE experience, clinic visits, courses and fellowships followed, and proctor supervision. RESULTS: This study included 2121 patients. The length of the learning curve was shorter for centers with an annual volume >50 compared to centers with an annual volume <50. Analysis with an annual volume cut-off of 30 cases showed similar but less pronounced results. No outcomes suggesting more efficient learning were found for longer experience as consultant, visiting an expert clinic, completing a minimally invasive esophagectomy fellowship or implementation under proctor supervision. CONCLUSIONS: More efficient learning was observed in centers with higher annual volume. Visiting an expert clinic, completing a fellowship, or implementation under a proctor's supervision were not associated with more efficient learning.


Asunto(s)
Neoplasias Esofágicas , Laparoscopía , Cirujanos , Estudios de Cohortes , Neoplasias Esofágicas/complicaciones , Neoplasias Esofágicas/cirugía , Esofagectomía/métodos , Hospitales , Humanos , Laparoscopía/métodos , Curva de Aprendizaje , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Resultado del Tratamiento
3.
Ugeskr Laeger ; 165(27): 2751-2, 2003 Jun 30.
Artículo en Danés | MEDLINE | ID: mdl-12886568

RESUMEN

Acute compartment syndrome (CS) is a limb threatening condition which warrants emergency treatment. We describe a case of a 37-year-old man with acute CS developed without major trauma. Early diagnosis and prompt treatment by decompressive fasciotomy is of vital importance in order to preserve limb function and to avoid complications. As a consequence of this case the department purchased a pressure transducer. Measurement of high pressure could have saved the patient for an undue risk of serious complications.


Asunto(s)
Tobillo , Tobillo/fisiopatología , Síndromes Compartimentales/etiología , Traumatismos de la Pierna/complicaciones , Pierna , Enfermedad Aguda , Adulto , Tobillo/cirugía , Síndromes Compartimentales/diagnóstico , Síndromes Compartimentales/cirugía , Humanos , Pierna/fisiopatología , Pierna/cirugía , Traumatismos de la Pierna/fisiopatología , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...