Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 149
Filtrar
3.
Mov Disord ; 38(7): 1223-1235, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37165974

RESUMEN

BACKGROUND: Double-blind, sham-controlled neurosurgical trials for neurodegenerative disorders are debated as an ethical dilemma, particularly regarding subjects randomized to the sham surgery group with general anesthesia. OBJECTIVE: The objective of this study was to examine the safety of sham surgeries in Parkinson's disease (PD) clinical trials through complications related to the procedure. METHODS: A systematic review and meta-analysis were performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Rates and odds ratios (OR) were compared using random effects analysis. RESULTS: Seven studies, all randomized, double-blind, sham surgery-controlled trials, with 309 patients with PD, were qualitatively and quantitatively analyzed: 141 patients in sham groups and 168 patients in the experimental arms of gene or cell therapy trials. Sham subjects had lower rates of gastrointestinal, positioning, incision-site, respiratory (hypoxic or hypercapnic respiratory failure), cardiovascular, thromboembolism, postoperative cognitive decline, skull fracture, and intracranial or spinal complications when compared with active treatment subjects. Sham subjects, however, had a higher rate of perioperative respiratory infections, such as pneumonia or sinusitis. Further, sham subjects were less likely to experience postoperative cognitive decline (OR, 0.23; 95% confidence interval [CI]: 0.11-0.47), intracranial or spinal complications (OR, 0.10; 95% CI: 0.01-0.75), total major morbidity (OR, 0.30; 95% CI: 0.19-0.47), or overall complications (OR, 0.59; 95% CI: 0.47-0.75) when compared with patients receiving experimental therapy. CONCLUSIONS: Patients with PD in the sham surgery control arm of cell transplantation or gene therapy clinical trials have a low risk of procedure-related adverse events overall and fewer complications than patients in the experimental groups. There were no reported deaths attributed to sham surgery-controlled PD clinical trials. © 2023 International Parkinson and Movement Disorder Society.


Asunto(s)
Enfermedad de Parkinson , Complicaciones Cognitivas Postoperatorias , Humanos , Enfermedad de Parkinson/cirugía , Enfermedad de Parkinson/tratamiento farmacológico , Ensayos Clínicos Controlados Aleatorios como Asunto
4.
Zootaxa ; 5353(4): 379-392, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-38220677

RESUMEN

Here we describe a new species of sea anemone from the family Aiptasiidae based on specimens collected from the Gulf of Mexico (USA: Florida & Alabama). Accounts of this species have been known since the early 1990s, primarily from an underwater field guide and hobbyist aquarium literature under the name Lightbulb Anemone. We describe it as a new species from the genus Bellactis based on anatomy, histology, and cnidom. Members of this species are small in size, with a smooth, typically contracted column divided into regions based on color and bearing rows of two or three elevated cinclides in the mid column. Their tentacles are distinctive, translucent, distally inflated and can be bulbous in shape, with sub annular rings. This description synthesizes information about Bellactis and contextualizes what is known about its diversity in light of other members of the Aiptasiidae.


Asunto(s)
Antozoos , Anémonas de Mar , Animales , Anémonas de Mar/anatomía & histología , Golfo de México
5.
Front Hum Neurosci ; 17: 1339340, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38384668

RESUMEN

Deep brain stimulation (DBS) of the anterior limb of the internal capsule (ALIC) has been used to treat refractory obsessive-compulsive disorder (OCD) and depression, but outcomes are variable, with some patients not responding to this form of invasive neuromodulation. A lack of benefit in some patients may be due to suboptimal positioning of DBS leads. Recently, studies have suggested that specific white matter tracts within the ALIC are associated with improved outcomes. Here, we present the case of a patient who initially had a modest improvement in OCD and depressive symptoms after receiving DBS within the ALIC. Subsequently, he underwent unilateral DBS lead repositioning informed by tractography targeting the ventrolateral and medial prefrontal cortex's connection with the mediodorsal thalamus. In this patient, we also conducted post-implant and post-repositioning diffusion imaging and found that we could successfully perform tractography even with DBS leads in place. Following lead repositioning into tracts predictive of benefit, the patient reached responder criteria for his OCD, and his depression was remitted. This case illustrates that tractography can potentially be used in the evaluation and planning of lead repositioning to achieve therapeutic outcomes.

6.
Neurosurgery ; 91(5): 717-725, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-36069560

RESUMEN

BACKGROUND: Interventional MRI (iMRI)-guided implantation of deep brain stimulator (DBS) leads has been developed to treat patients with Parkinson's disease (PD) without the need for awake testing. OBJECTIVE: Direct comparisons of targeting accuracy and clinical outcomes for awake stereotactic with asleep iMRI-DBS for PD are limited. METHODS: We performed a retrospective review of patients with PD who underwent awake or iMRI-guided DBS surgery targeting the subthalamic nucleus or globus pallidus interna between 2013 and 2019 at our institution. Outcome measures included Unified Parkinson's Disease Rating Scale Part III scores, levodopa equivalent daily dose, radial error between intended and actual lead locations, stimulation parameters, and complications. RESULTS: Of the 218 patients included in the study, the iMRI cohort had smaller radial errors (iMRI: 1.27 ± 0.72 mm, awake: 1.59 ± 0.96 mm, P < .01) and fewer lead passes (iMRI: 1.0 ± 0.16, awake: 1.2 ± 0.41, P < .01). Changes in Unified Parkinson's Disease Rating Scale were similar between modalities, but awake cases had a greater reduction in levodopa equivalent daily dose than iMRI cases ( P < .01), which was attributed to the greater number of awake subthalamic nucleus cases on multivariate analysis. Effective clinical contacts used for stimulation, side effect thresholds, and complication rates were similar between modalities. CONCLUSION: Although iMRI-DBS may result in more accurate lead placement for intended target compared with awake-DBS, clinical outcomes were similar between surgical approaches. Ultimately, patient preference and surgeon experience with a given DBS technique should be the main factors when determining the "best" method for DBS implantation.


Asunto(s)
Estimulación Encefálica Profunda , Imagen por Resonancia Magnética Intervencional , Enfermedad de Parkinson , Estimulación Encefálica Profunda/métodos , Humanos , Levodopa/uso terapéutico , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/terapia , San Francisco , Resultado del Tratamiento , Vigilia
7.
Mov Disord Clin Pract ; 9(6): 775-784, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35937489

RESUMEN

Background: Despite over 30 years of clinical experience, high-quality studies on the efficacy of bilateral versus unilateral deep brain stimulation (DBS) of the ventral intermediate (VIM) nucleus of the thalamus for medically refractory essential tremor (ET) remain limited. Objectives: To compare benefits and risks of bilateral versus unilateral VIM DBS using the largest ET DBS clinical trial dataset available to date. Methods: Participants from the US St. Jude/Abbott pivotal ET DBS trial who underwent staged-bilateral VIM implantation constituted the primary cohort in this sub-analysis. Their assessments "on" DBS at six months after second-side VIM DBS implantation were compared to the assessments six months after unilateral implantation. Two control cohorts of participants with unilateral implantation only were also used for between-group comparisons. Results: The primary cohort consisted of n = 38 ET patients (22M/16F; age of 65.3 ± 9.5 years). The second side VIM-DBS resulted in a 29.6% additional improvement in the total motor CRST score (P < 0.001), with a 64.1% CRST improvement in the contralateral side (P < 0.001). An added improvement was observed in the axial tremor score (21.4%, P = 0.005), and CRST part B (24.8%, P < 0.001) score. Rate of adverse events was slightly higher after bilateral stimulation. Conclusions: In the largest ET DBS study to date, staged-bilateral VIM DBS was a highly effective treatment for ET with bilateral implantation resulting in greater reduction in total motor tremor scores when compared to unilateral stimulation alone.

10.
J Am Coll Radiol ; 19(3): 488-492, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35094941

RESUMEN

The ACR Council passed Resolution 47 at its 2020 annual meeting establishing a representative task force (TF) to explore the concept of the "multispecialty radiologist," previously proposed in 2012. The TF held eight virtual meetings over 8 months, considered data from a 2020 ACR Membership Tracking Survey, conducted a review of current literature, and collected anecdotal experience from TF members and ACR leadership. ACR legal counsel and a cross-section of ACR Commissions and Committees also provided input. The TF concluded that there is scant interest from the radiology community in the multispecialty radiologist title and no agreed-upon definition for the term. Radiologists may identify as diagnostic or subspecialty radiologists; however, the roles they fill in clinical practice include general, multispecialty, and subspecialized radiology. The TF proposes definitions for each of these terms to support radiologist recruitment aligned with optimal patient care in the practice community and to improve the quality of data collection about the field. To reduce ambiguity, the TF proposes adoption of the defined terms by the radiology community, including radiologist recruiters and employers, and suggests ways in which resident training and the ABR board examination can be adapted to support this new structure. Additionally, as part of an exploration of hyperspecialization and trainee preparedness for clinical practice, the TF discussed the challenges faced by community-based practices seeking to provide a full range of high-quality, radiologist-delivered diagnostic and interventional services to their patient populations.


Asunto(s)
Radiología , Comités Consultivos , Recolección de Datos , Humanos , Radiografía , Radiólogos , Estados Unidos
11.
Hum Brain Mapp ; 43(2): 633-646, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34609038

RESUMEN

Neuromodulation treatment effect size for bothersome tinnitus may be larger and more predictable by adopting a target selection approach guided by personalized striatal networks or functional connectivity maps. Several corticostriatal mechanisms are likely to play a role in tinnitus, including the dorsal/ventral striatum and the putamen. We examined whether significant tinnitus treatment response by deep brain stimulation (DBS) of the caudate nucleus may be related to striatal network increased functional connectivity with tinnitus networks that involve the auditory cortex or ventral cerebellum. The first study was a cross-sectional 2-by-2 factorial design (tinnitus, no tinnitus; hearing loss, normal hearing, n = 68) to define cohort level abnormal functional connectivity maps using high-field 7.0 T resting-state fMRI. The second study was a pilot case-control series (n = 2) to examine whether tinnitus modulation response to caudate tail subdivision stimulation would be contingent on individual level striatal connectivity map relationships with tinnitus networks. Resting-state fMRI identified five caudate subdivisions with abnormal cohort level functional connectivity maps. Of those, two connectivity maps exhibited increased connectivity with tinnitus networks-dorsal caudate head with Heschl's gyrus and caudate tail with the ventral cerebellum. DBS of the caudate tail in the case-series responder resulted in dramatic reductions in tinnitus severity and loudness, in contrast to the nonresponder who showed no tinnitus modulation. The individual level connectivity map of the responder was in alignment with the cohort expectation connectivity map, where the caudate tail exhibited increased connectivity with tinnitus networks, whereas the nonresponder individual level connectivity map did not.


Asunto(s)
Corteza Auditiva/fisiopatología , Núcleo Caudado/fisiopatología , Cerebelo/fisiopatología , Conectoma , Estimulación Encefálica Profunda , Pérdida Auditiva/fisiopatología , Red Nerviosa/fisiopatología , Acúfeno/fisiopatología , Acúfeno/terapia , Adulto , Anciano , Corteza Auditiva/diagnóstico por imagen , Estudios de Casos y Controles , Núcleo Caudado/diagnóstico por imagen , Cerebelo/diagnóstico por imagen , Estudios Transversales , Femenino , Pérdida Auditiva/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Red Nerviosa/diagnóstico por imagen , Acúfeno/diagnóstico por imagen
12.
Neurology ; 98(1): e40-e50, 2022 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-34649873

RESUMEN

BACKGROUND AND OBJECTIVES: To report final, 36-month safety and clinical outcomes from the PD-1101 trial of NBIb-1817 (VY-AADC01) in participants with moderately advanced Parkinson disease (PD) and motor fluctuations. METHODS: PD-1101 was a phase 1b, open-label, dose escalation trial of VY-AADC01, an experimental AAV2 gene therapy encoding the human aromatic l-amino acid decarboxylase (AADC) enzyme. VY-AADC01 was delivered via bilateral, intraoperative MRI-guided putaminal infusions to 3 cohorts (n = 5 participants per cohort): cohort 1, ≤7.5 × 1011 vector genomes (vg); cohort 2, ≤1.5 × 1012 vg; cohort 3, ≤4.7 × 1012 vg. RESULTS: No serious adverse events (SAEs) attributed to VY-AADC01 were reported. All 4 non-vector-related SAEs (atrial fibrillation and pulmonary embolism in 1 participant and 2 events of small bowel obstruction in another participant) resolved. Requirements for PD medications were reduced by 21%-30% in the 2 highest dose cohorts at 36 months. Standard measures of motor function (PD diary, Unified Parkinson's Disease Rating Scale III "off"-medication and "on"-medication scores), global impressions of improvement (Clinical Global Impression of Improvement, Patient Global Impression of Improvement), and quality of life (39-item Parkinson's Disease Questionnaire) were stable or improved compared with baseline at 12, 24, and 36 months following VY-AADC01 administration across cohorts. DISCUSSIONS: VY-AADC01 and the surgical administration procedure were well-tolerated and resulted in stable or improved motor function and quality of life across cohorts, as well as reduced PD medication requirements in cohorts 2 and 3 over 3 years. TRIAL REGISTRATION INFORMATION: NCT01973543. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that, in patients with moderately advanced PD and motor fluctuations, putaminal infusion of VY-AADC01 is well tolerated and may improve motor function.


Asunto(s)
Carboxiliasas , Enfermedad de Parkinson , Aminoácidos/genética , Aminoácidos/uso terapéutico , Antiparkinsonianos/efectos adversos , Carboxiliasas/uso terapéutico , Terapia Genética/métodos , Humanos , Enfermedad de Parkinson/tratamiento farmacológico , Calidad de Vida , Resultado del Tratamiento
13.
Front Neurol ; 12: 785280, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34925219

RESUMEN

Objective: There have been significant improvements in the design and manufacturing of deep brain stimulation (DBS) systems, but no study has considered the impact of modern systems on complications. We sought to compare the relative occurrence of reoperations after de novo implantation of modern and traditional DBS systems in patients with Parkinson's disease (PD) or essential tremor (ET) in the United States. Design: Retrospective, contemporaneous cohort study. Setting: Multicenter data from the United States Centers for Medicare and Medicaid Services administrative claims database between 2016 and 2018. Participants: This population-based sample consisted of 5,998 patients implanted with a DBS system, of which 3,869 patients had a de novo implant and primary diagnosis of PD or ET. Follow-up of 3 months was available for 3,810 patients, 12 months for 3,561 patients, and 24 months for 1,812 patients. Intervention: Implantation of a modern directional (MD) or traditional omnidirectional (TO) DBS system. Primary and Secondary Outcome Measures: We hypothesized that MD systems would impact complication rates. Reoperation rate was the primary outcome. Associated diagnoses, patient characteristics, and implanting center details served as covariates. Kaplan-Meier analysis was performed to compare rates of event-free survival and regression models were used to determine covariate influences. Results: Patients implanted with modern systems were 36% less likely to require reoperation, largely due to differences in acute reoperations and intracranial lead reoperations. Risk reduction persisted while accounting for practice differences and implanting center experience. Risk reduction was more pronounced in patients with PD. Conclusions: In the first multicenter analysis of device-related complications including modern DBS systems, we found that modern systems are associated with lower reoperation rates. This risk profile should be carefully considered during device selection for patients undergoing DBS for PD or ET. Prospective studies are needed to further investigate underlying causes.

14.
J Parkinsons Dis ; 11(s2): S199-S206, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34366372

RESUMEN

A number of cell transplantation and gene therapy trials have been performed over the last three decades in an effort to restore function in Parkinson's disease. Much has been learned about optimizing delivery methods for these therapeutics. This is particularly true in gene therapy, which has predominated the clinical trial landscape in recent years; however, cell transplantation for Parkinson's disease is currently undergoing a renaissance. Innovations such as cannula design, iMRI-guided surgery and an evolution in delivery strategy has radically changed the way investigators approach clinical trial design. Future therapeutic strategies may employ newer delivery methods such as chronically implanted infusion devices and focal opening of the blood brain barrier with focused ultrasound.


Asunto(s)
Enfermedad de Parkinson , Barrera Hematoencefálica , Trasplante de Células , Terapia Genética , Humanos , Enfermedad de Parkinson/terapia
15.
Nat Commun ; 12(1): 4251, 2021 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-34253733

RESUMEN

Aromatic L-amino acid decarboxylase (AADC) deficiency is a rare genetic disorder characterized by deficient synthesis of dopamine and serotonin. It presents in early infancy, and causes severe developmental disability and lifelong motor, behavioral, and autonomic symptoms including oculogyric crises (OGC), sleep disorder, and mood disturbance. We investigated the safety and efficacy of delivery of a viral vector expressing AADC (AAV2-hAADC) to the midbrain in children with AADC deficiency (ClinicalTrials.gov Identifier NCT02852213). Seven (7) children, aged 4-9 years underwent convection-enhanced delivery (CED) of AAV2-hAADC to the bilateral substantia nigra (SN) and ventral tegmental area (VTA) (total infusion volume: 80 µL per hemisphere) in 2 dose cohorts: 1.3 × 1011 vg (n = 3), and 4.2 × 1011 vg (n = 4). Primary aims were to demonstrate the safety of the procedure and document biomarker evidence of restoration of brain AADC activity. Secondary aims were to assess clinical improvement in symptoms and motor function. Direct bilateral infusion of AAV2-hAADC was safe, well-tolerated and achieved target coverage of 98% and 70% of the SN and VTA, respectively. Dopamine metabolism was increased in all subjects and FDOPA uptake was enhanced within the midbrain and the striatum. OGC resolved completely in 6 of 7 subjects by Month 3 post-surgery. Twelve (12) months after surgery, 6/7 subjects gained normal head control and 4/7 could sit independently. At 18 months, 2 subjects could walk with 2-hand support. Both the primary and secondary endpoints of the study were met. Midbrain gene delivery in children with AADC deficiency is feasible and safe, and leads to clinical improvements in symptoms and motor function.


Asunto(s)
Errores Innatos del Metabolismo de los Aminoácidos/genética , Errores Innatos del Metabolismo de los Aminoácidos/terapia , Descarboxilasas de Aminoácido-L-Aromático/deficiencia , Dependovirus/genética , Neuronas Dopaminérgicas/metabolismo , Técnicas de Transferencia de Gen , Terapia Genética , Imagen por Resonancia Magnética , Mesencéfalo/patología , Errores Innatos del Metabolismo de los Aminoácidos/líquido cefalorraquídeo , Errores Innatos del Metabolismo de los Aminoácidos/fisiopatología , Descarboxilasas de Aminoácido-L-Aromático/líquido cefalorraquídeo , Descarboxilasas de Aminoácido-L-Aromático/genética , Niño , Preescolar , Discinesias/fisiopatología , Femenino , Terapia Genética/efectos adversos , Humanos , Masculino , Metaboloma , Actividad Motora , Neurotransmisores/líquido cefalorraquídeo , Neurotransmisores/metabolismo , Factores de Tiempo
17.
Nat Biotechnol ; 39(9): 1078-1085, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33941932

RESUMEN

Neural recordings using invasive devices in humans can elucidate the circuits underlying brain disorders, but have so far been limited to short recordings from externalized brain leads in a hospital setting or from implanted sensing devices that provide only intermittent, brief streaming of time series data. Here, we report the use of an implantable two-way neural interface for wireless, multichannel streaming of field potentials in five individuals with Parkinson's disease (PD) for up to 15 months after implantation. Bilateral four-channel motor cortex and basal ganglia field potentials streamed at home for over 2,600 h were paired with behavioral data from wearable monitors for the neural decoding of states of inadequate or excessive movement. We validated individual-specific neurophysiological biomarkers during normal daily activities and used those patterns for adaptive deep brain stimulation (DBS). This technological approach may be widely applicable to brain disorders treatable by invasive neuromodulation.


Asunto(s)
Adaptación Fisiológica , Monitorización Neurofisiológica/métodos , Enfermedad de Parkinson/fisiopatología , Tecnología Inalámbrica , Adulto , Estimulación Encefálica Profunda , Femenino , Humanos , Masculino , Persona de Mediana Edad , Corteza Motora/fisiopatología , Movimiento , Enfermedad de Parkinson/terapia , Dispositivos Electrónicos Vestibles
18.
J Neurosurg ; 135(6): 1889-1897, 2021 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-33930864

RESUMEN

OBJECTIVE: Surgical site infection (SSI) is a complication linked to increased costs and length of hospital stay. Prevention of SSI is important to reduce its burden on individual patients and the healthcare system. The authors aimed to assess the efficacy of preoperative chlorhexidine gluconate (CHG) showers on SSI rates following cranial surgery. METHODS: In November 2013, a preoperative CHG shower protocol was implemented at the authors' institution. A total of 3126 surgical procedures were analyzed, encompassing a time frame from April 2012 to April 2016. Cohorts before and after implementation of the CHG shower protocol were evaluated for differences in SSI rates. RESULTS: The overall SSI rate was 0.6%. No significant differences (p = 0.11) were observed between the rate of SSI of the 892 patients in the preimplementation cohort (0.2%) and that of the 2234 patients in the postimplementation cohort (0.8%). Following multivariable analysis, implementation of preoperative CHG showers was not associated with decreased SSI (adjusted OR 2.96, 95% CI 0.67-13.1; p = 0.15). CONCLUSIONS: This is the largest study, according to sample size, to examine the association between CHG showers and SSI following craniotomy. CHG showers did not significantly alter the risk of SSI after a cranial procedure.

19.
J Neural Eng ; 18(5)2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33740780

RESUMEN

Objective.The effectiveness of deep brain stimulation (DBS) depends on electrode placement accuracy, which can be compromised by brain shift during surgery. While there have been efforts in assessing the impact of electrode misplacement due to brain shift using preop- and postop-imaging data, such analysis using preop- and intraop-imaging data via biophysical modeling has not been conducted. This work presents a preliminary study that applies a multi-physics analysis framework using finite element biomechanical and bioelectric models to examine the impact of realistic intraoperative shift on neural pathways determined by tractography.Approach.The study examined six patients who had undergone interventional magnetic resonance-guided DBS surgery. The modeling framework utilized a biomechanical approach to update preoperative MR to reflect shift-induced anatomical changes. Using this anatomically deformed image and its undeformed counterpart, bioelectric effects from shifting electrode leads could be simulated and neural activation differences were approximated. Specifically, for each configuration, volume of tissue activation was computed and subsequently used for tractography estimation. Total tract volume and overlapping volume with motor regions as well as connectivity profile were compared. In addition, volumetric overlap between different fiber bundles among configurations was computed and correlated to estimated shift.Main results.The study found deformation-induced differences in tract volume, motor region overlap, and connectivity behavior, suggesting the impact of shift. There is a strong correlation (R= -0.83) between shift from intended target and intended neural pathway recruitment, where at threshold of ∼2.94 mm, intended recruitment completely degrades. The determined threshold is consistent with and provides quantitative support to prior observations and literature that deviations of 2-3 mm are detrimental.Significance.The findings support and advance prior studies and understanding to illustrate the need to account for shift in DBS and the potentiality of computational modeling for estimating influence of shift on neural activation.


Asunto(s)
Estimulación Encefálica Profunda , Encéfalo/cirugía , Estimulación Encefálica Profunda/métodos , Análisis de Elementos Finitos , Humanos , Vías Nerviosas , Física
20.
Stereotact Funct Neurosurg ; 99(3): 196-202, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33535219

RESUMEN

INTRODUCTION: During deep brain stimulation (DBS) surgery, computed tomography (CT) and magnetic resonance imaging (MRI) scans need to be co-registered or fused. Image fusion is associated with the error that can distort the location of anatomical structures. Co-registration in DBS surgery is usually performed automatically by proprietary software; the amount of error during this process is not well understood. Here, our goal is to quantify the error during automated image co-registration with FrameLink™, a commonly used software for DBS planning and clinical research. METHODS: This is a single-center retrospective study at a quaternary care referral center, comparing CT and MR imaging co-registration for a consecutive series of patients over a 12-month period. We collected CT images and MRI scans for 22 patients with Parkinson's disease requiring placement of DBS. Anatomical landmarks were located on CT images and MRI scans using a novel image analysis algorithm that included a method for capturing the potential error inherent in the image standardization step of the analysis. The distance between the anatomical landmarks was measured, and the error was found by averaging the distances across all patients. RESULTS: The average error during co-registration was 1.25 mm. This error was significantly larger than the error resulting from image standardization (0.19 mm) and was worse in the anterior-posterior direction. CONCLUSIONS: The image fusion errors found in this analysis were nontrivial. Although the estimated error may be inflated, it is sig-nificant enough that users must be aware of this potential inaccuracy, and developers of proprietary software should provide details about the magnitude and direction of co-registration errors.


Asunto(s)
Estimulación Encefálica Profunda , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos , Programas Informáticos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...