2.
J Vis Exp ; (193)2023 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-37010308

RESUMEN

A well-validated and holistic program that incorporates robust gowning, cleaning, environmental monitoring, and personnel monitoring measures is critical for minimizing the microbial bioburden in cellular therapy manufacturing suites and the corresponding testing laboratories to ensure that the facilities are operating in a state of control. Ensuring product safety via quality control measures, such as sterility testing, is a regulatory requirement for both minimally manipulated (section 361) and more than minimally manipulated (section 351) human cells, tissues, and cellular and tissue-based products (HCT/Ps). In this video, we provide a stepwise guide for how to develop and incorporate the best aseptic practices for operating in a cleanroom environment, including gowning, cleaning, staging of materials, environmental monitoring, process monitoring, and product sterility testing using direct inoculation, provided by the United States Pharmacopeia (USP<71>) and the National Institutes of Health (NIH) Alternative Sterility Testing Method. This protocol is intended as a reference guide for establishments expected to meet current good tissue practices (cGTP) and current good manufacturing practices (cGMP).


Asunto(s)
Ambiente Controlado , Infertilidad , Humanos
3.
J Clin Microbiol ; 61(4): e0171222, 2023 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-36912659

RESUMEN

The Streptococcus bovis group (previously group D streptococci) consists of seven distinct species and subspecies. Definitive identification within the group is important, as certain organisms have been associated with gastrointestinal carcinoma, bacteremia, infective endocarditis, meningitis, biliary tract disease, and carcinoma, among others. Definitive identification, however, remains elusive due to limitations and inconsistencies across commonly used identification platforms in the United States. Here, we compared the performance of standard biochemical (Trek Gram-positive identification [GPID] plate, Vitek 2 GPID), sequencing (16S rDNA, sodA) databases (NCBI, RDP, CDC MicrobeNet), and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) platforms (Vitek MS, Bruker Biotyper MS) using a set of eight type strains representing all seven strains within the S. bovis group. Despite the evaluation of contemporary methods, no single platform was able to definitively identify all type strains within the S. bovis group. Vitek MS (85.7%, 7/8) provided the most accurate definitive identifications, followed by sodA sequencing (75%, 6/8). Vitek 2 and Bruker Biotyper RUO platforms performed the next best (62.5%, 5/8). All remaining platforms failed to adequately differentiate type strains within the S. bovis group (range, 0 to 37.5%). Laboratorians and clinicians should be aware of the identification limitations of routine testing algorithms and incorporate reflex testing, when appropriate, to platforms such as Vitek MS and/or sodA sequencing that are more able to definitively identify S. bovis group organisms. Further clinical evaluation was conducted using 65 clinical isolates from three geographically distinct U.S. institutions. Future improvements in identification platforms may reveal new clinical and epidemiological trends for members of the S. bovis group.


Asunto(s)
Bacteriemia , Endocarditis , Streptococcus bovis , Humanos , Streptococcus bovis/genética , Proteómica , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
4.
J Clin Microbiol ; 61(3): e0135322, 2023 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-36853008

RESUMEN

Accurate mold identification by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is dependent on robust organism representation in available databases. The Mass Spectrometry Identification (MSI) platform has proven successful for mold identification in clinical and veterinary settings but has yet to be studied with a large set of environmental isolates. Here, we performed a retrospective study using spectra collected by the Bruker MALDI Biotyper (MBT) v4.1 microflex LT instrument to evaluate the MSI-2 database alongside the combined use of the Bruker MBT (including the MBT Filamentous Fungi Library) and the National Institutes of Health (NIH) mold database (MBT/NIH databases). Analysis was performed for 462 environmental fungal isolates (representing 73 different fungi) cultured from the hospital pharmacy and cellular therapy suites as part of the current good manufacturing practices (cGMP) environmental monitoring program at the NIH. When used alone, MSI-2 identified 237 spectra (51.3%) at its higher score threshold (index A), while the MBT/NIH databases identified only 183 spectra (39.6%; P < 0.001) at the equivalent threshold of ≥2.0. The combination of all three databases at the respective high thresholds improved identification sensitivity to 327 spectra (70.8%). The combination of MSI-2 with the MBT/NIH databases at a lowered threshold (index B or ≥1.7, respectively) identified 400/462 environmental spectra (86.6%). Our results show that the MSI-2 database, in combination with existing databases, may be useful for environmental surveillance, particularly by clinical or industry laboratories involved in cGMP or current good tissue practices (cGTP) applications, such as cellular therapy manufacturing facilities and sterile compounding pharmacies.


Asunto(s)
Hongos , Humanos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Estudios Retrospectivos , Bases de Datos Factuales
5.
J Clin Microbiol ; 61(3): e0165422, 2023 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-36847535

RESUMEN

Over the last two decades, rapid technological advances have led to the wide adoption of cell and gene therapy products for the treatment of a variety of disease states. In this study, we reviewed the literature between 2003 and 2021 to provide a summary of overarching trends associated with microbial contamination in hematopoietic stem cells (HSCs) derived from peripheral blood, bone marrow, and cord blood. We provide a brief background on the regulatory context for human cells, tissues, and cellular and tissue-based products (HCT/Ps) as regulated by the US Food and Drug Administration (FDA), sterility testing expectations for autologous (Section 361) and allogeneic (Section 351) HSC products, and discuss clinical risks associated with the infusion of a contaminated HSC product. Finally, we discuss the expectations for current good tissue practices (cGTP) and current good manufacturing practices (cGMP) for the manufacturing and testing of HSC based on Section 361 and Section 351 categorization, respectively. We provide commentary on what is practiced in the field and discuss the critical need for updates to professional standards that keep pace with advancing technologies with an aim to clarify expectations for manufacturing and testing facilities to improve standardization across institutions.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Infertilidad , Humanos , Células Madre Hematopoyéticas , Médula Ósea
6.
J Clin Microbiol ; 61(2): e0149822, 2023 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-36688643

RESUMEN

Testing of cellular therapy products for Mycoplasma is a regulatory requirement by the United States Food and Drug Administration (FDA) to ensure the sterility and safety of the product prior to release for patient infusion. The risk of Mycoplasma contamination in cell culture is high. Gold standard testing follows USP 63 which requires a 28-day agar and broth cultivation method that is impractical for short shelf-life biologics. Several commercial molecular platforms have been marketed for faster raw material and product release testing; however, little performance data are available in the literature. In this study, we performed a proof-of-principle analysis to evaluate the performance of five commercial molecular assays, including the MycoSEQ Mycoplasma detection kit (Life Technologies), the MycoTOOL Mycoplasma real-time detection kit (Roche), the VenorGEM qOneStep kit (Minerva Biolabs), the ATCC universal Mycoplasma detection kit, and the Biofire Mycoplasma assay (bioMérieux Industry) using 10 cultured Mollicutes spp., with each at four log-fold dilutions (1,000 CFU/mL to 1 CFU/mL) in biological duplicates with three replicates per condition (n = 6) to assess limit of detection (LOD) and repeatability. Additional testing was performed in the presence of tumor infiltrating lymphocytes (TILs). Based on LOD alone, the Biofire Mycoplasma assay was most sensitive followed by the MycoSEQ and MycoTOOL which were comparable. We showed that not all assays were capable of meeting the ≤10 CFU/mL LOD to replace culture-based methods according to European and Japanese pharmacopeia standards. No assay interference was observed when testing in the presence of TILs.


Asunto(s)
Mycoplasma , Humanos , Límite de Detección , Técnicas de Cultivo de Célula , Estándares de Referencia , Tratamiento Basado en Trasplante de Células y Tejidos
7.
J Clin Microbiol ; 59(11): e0135721, 2021 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-34406794

RESUMEN

The U.S. Food and Drug Administration (FDA) regulates manufacturing and testing of advanced therapeutic medicinal products (ATMPs) to ensure the safety of each product for human use. Gold-standard sterility testing (USP<71>) and alternative blood culture systems have major limitations for the detection of fungal contaminants. In this study, we evaluated the performance of iLYM (lactic acid-fermenting organisms, yeasts, and mold) medium (designed originally for the food and beverage industry) to assess its potential for use in the biopharmaceutical field for ATMP sterility testing. We conducted a parallel evaluation of four different test systems (USP<71>, BacT/Alert, Bactec, and Sabouraud dextrose agar [SDA] culture), three different bottle media formulations (iLYM, iFA Plus, and Myco/F Lytic), and two incubation temperatures (22.5°C and 32.5 to 35°C) using a diverse set of fungi (n = 51) isolated from NIH cleanroom environments and previous product contaminants. Additionally, we evaluated the effect of agitation versus delayed-entry static preincubation on test sensitivity and time to detection (TTD). Overall, delayed entry of bottles onto the BacT/Alert or Bactec instruments (with agitation) did not improve test performance. USP<71> and SDA culture continued to significantly outperform each automated culture condition alone. However, we show, for the first time, that a closed-system, dual-bottle combination of iLYM 22.5°C and iFA Plus 32.5°C can provide high fungal sensitivity, statistically comparable to USP<71>, when tested against a diverse range of environmental fungi. Our study fills a much-needed gap in biopharmaceutical testing and offers a favorable testing algorithm that maximizes bacterial and fungal test sensitivity while minimizing risk of product contamination associated with laboratory handling.


Asunto(s)
Bacterias , Hongos , Medios de Cultivo , Contaminación de Medicamentos , Hongos/genética , Terapia Genética , Humanos
8.
Clin Lab Med ; 41(2): 267-283, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34020763

RESUMEN

Many studies have shown successful performance of matrix-assisted laser desorption ionization time-of-flight mass spectrometry for rapid yeast and mold identification, yet few laboratories have chosen to apply this technology into their routine clinical mycology workflow. This review provides an overview of the current status of matrix-assisted laser desorption ionization time-of-flight mass spectrometry for fungal identification, including key findings in the literature, processing and database considerations, updates in technology, and exciting future prospects. Significant advances toward standardization have taken place recently; thus, accurate species-level identification of yeasts and molds should be highly attainable, achievable, and practical in most clinical laboratories.


Asunto(s)
Micosis , Hongos , Humanos , Rayos Láser , Micosis/diagnóstico , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Levaduras
9.
J Clin Microbiol ; 59(3)2021 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-33262219

RESUMEN

We evaluated saliva (SAL) specimens for SARS-CoV-2 reverse transcriptase PCR (RT-PCR) testing by comparison of 459 prospectively paired nasopharyngeal (NP) or midturbinate (MT) swabs from 449 individuals with the aim of using saliva for asymptomatic screening. Samples were collected in a drive-through car line for symptomatic individuals (n = 380) and in the emergency department (ED) (n = 69). The percentages of positive and negative agreement of saliva compared to nasopharyngeal swab were 81.1% (95% confidence interval [CI], 65.8% to 90.5%) and 99.8% (95% CI, 98.7% to 100%), respectively. The percent positive agreement increased to 90.0% (95% CI, 74.4% to 96.5%) when considering only samples with moderate to high viral load (cycle threshold [CT ] for the NP, ≤34). Pools of five saliva specimens were also evaluated on three platforms, bioMérieux NucliSENS easyMAG with ABI 7500Fast (CDC assay), Hologic Panther Fusion, and Roche Cobas 6800. The average loss of signal upon pooling was 2 to 3 CT values across the platforms. The sensitivities of detecting a positive specimen in a pool compared with testing individually were 94%, 90%, and 94% for the CDC 2019-nCoV real-time RT-PCR, Panther Fusion SARS-CoV-2 assay, and Cobas SARS-CoV-2 test, respectively, with decreased sample detection trending with lower viral load. We conclude that although pooled saliva testing, as collected in this study, is not quite as sensitive as NP/MT testing, saliva testing is adequate to detect individuals with higher viral loads in an asymptomatic screening program, does not require swabs or viral transport medium for collection, and may help to improve voluntary screening compliance for those individuals averse to various forms of nasal collections.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Tamizaje Masivo/métodos , SARS-CoV-2/aislamiento & purificación , Saliva/virología , Humanos , Nasofaringe , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Manejo de Especímenes/métodos
10.
medRxiv ; 2020 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-33052363

RESUMEN

We evaluated saliva (SAL) specimens for SARS-CoV-2 RT-PCR testing by comparison of 459 prospectively paired nasopharyngeal (NP) or mid-turbinate (MT) swabs from 449 individuals with the aim of using saliva for asymptomatic screening. Samples were collected in a drive-through car line for symptomatic individuals (N=380) and in the emergency department (ED) (N=69). The percent positive and negative agreement of saliva compared to nasopharyngeal swab were 81.1% (95% CI: 65.8% - 90.5%) and 99.8% (95% CI: 98.7% - 100%), respectively. The sensitivity increased to 90.0% (95% CI: 74.4% - 96.5%) when considering only samples with moderate to high viral load (Cycle threshold (Ct) for the NP <=34). Pools of five saliva specimens were also evaluated on three platforms: bioMérieux NucliSENS easyMAG with ABI 7500Fast (CDC assay), Hologic Panther Fusion, and Roche COBAS 6800. The median loss of signal upon pooling was 2-4 Ct values across the platforms. The sensitivity of detecting a positive specimen in a pool compared with testing individually was 100%, 93%, and 95% for CDC 2019-nCoV Real-Time RT-PCR, Panther Fusion® SARS-CoV-2 assay, and cobas® SARS-CoV-2 test respectively, with decreased sample detection trending with lower viral load. We conclude that although pooled saliva testing, as collected in this study, is not quite as sensitive as NP/MT testing, saliva testing is adequate to detect individuals with higher viral loads in an asymptomatic screening program, does not require swabs or viral transport media for collection, and may help to improve voluntary screening compliance for those individuals averse to various forms of nasal collections.

12.
J Clin Microbiol ; 58(7)2020 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-32321785

RESUMEN

Sterility testing of cellular therapy products along with the associated environmental monitoring requirements for aseptic facilities, including compounding pharmacies, continues to impact clinical microbiology laboratories, as evidenced by the numerous discussions recurring on American Society for Microbiology Division C and ClinMicroNet listservs. This minireview provides an overview of this complex field of current good manufacturing practices (cGMP) based on biopharmaceutical industry standards and summarizes the compendial and alternative rapid microbial test methods available for product sterility and Mycoplasma testing. In addition, this minireview highlights major overarching regulatory requirements governing any laboratory performing product testing as regulated by the United States Food and Drug Administration (FDA). These requirements are different from the more familiar clinical requirements of the Clinical Laboratory Improvement Act of 1988 (CLIA '88), the College of American Pathologists (CAP), and the Joint Commission on Accreditation of Healthcare Organizations (JCAHO), all of which have no jurisdiction in this area. As the cellular therapy field continues to advance and an increasing number of medical centers participate in clinical trials of these novel therapies, it is critical that laboratories have a sound understanding of the major regulations and cGMP practices governing microbiological testing in the biopharmaceutical industry.


Asunto(s)
Servicios de Laboratorio Clínico , Infertilidad , Tratamiento Basado en Trasplante de Células y Tejidos , Humanos , Laboratorios , Estados Unidos
13.
Front Microbiol ; 10: 2098, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31616388

RESUMEN

OBJECTIVES: Rapid and accurate mold identification is critical for guiding therapy for mold infections. MALDI-TOF MS has been widely adopted for bacterial and yeast identification; however, few clinical laboratories have applied this technology for routine mold identification due to limited database availability and lack of standardized processes. Here, we evaluated the versatility of the NIH Mold Database in a multicenter evaluation. METHODS: The NIH Mold Database was evaluated by eight US academic centers using a solid media extraction method and a challenge set of 80 clinical mold isolates. Multiple instrument parameters important for spectra optimization were evaluated, leading to the development of two specialized acquisition programs (NIH method and the Alternate-B method). RESULTS: A wide range in performance (33-77%) was initially observed across the eight centers when routine spectral acquisition parameters were applied. Use of the NIH or the Alternate-B specialized acquisition programs, which are different than those used routinely for bacterial and yeast spectral acquisition (MBT_AutoX), in combination with optimized instrument maintenance, improved performance, illustrating that acquisition parameters may be one of the key limiting variable in achieving successful performance. CONCLUSION: Successful mold identification using the NIH Database for MALDI-TOF MS on Biotyper systems was demonstrated across multiple institutions for the first time following identification of critical program parameters combined with instrument optimization. This significantly advances our potential to implement MALDI-TOF MS for mold identification across many institutions. Because instrument variability is inevitable, development of an instrument performance standard specific for mold spectral acquisition is suggested to improve reproducibility across instruments.

14.
mBio ; 10(5)2019 10 08.
Artículo en Inglés | MEDLINE | ID: mdl-31594809

RESUMEN

Antibiotics, which are used both to prevent and to treat infections, are a mainstay therapy for lifesaving procedures such as transplantation. For this reason, and many others, increased antibiotic resistance among human-associated pathogens, such as the carbapenem-resistant Enterobacteriaceae species, is of grave concern. In this study, we report on a hematopoietic stem cell transplant recipient in whom cultures detected the emergence of carbapenem resistance and spread across five strains of bacteria that persisted for over a year. Carbapenem resistance in Citrobacter freundii, Enterobacter cloacae, Klebsiella aerogenes, and Klebsiella pneumoniae was linked to a pair of plasmids, each carrying the Klebsiella pneumoniae carbapenemase gene (blaKPC). Surveillance cultures identified a carbapenem-susceptible strain of Citrobacter freundii that may have become resistant through horizontal gene transfer of these plasmids. Selection of a multidrug-resistant Klebsiella pneumoniae strain was also detected following combination antibiotic therapy. Here we report a plasmid carrying the blaKPC gene with broad host range that poses the additional threat of spreading to endogenous members of the human gut microbiome.IMPORTANCE Antibiotic-resistant bacteria are a serious threat to medically fragile patient populations. The spread of antibiotic resistance through plasmid-mediated mechanisms is of grave concern as it can lead to the conversion of endogenous patient-associated strains to difficult-to-treat pathogens.


Asunto(s)
Antibacterianos/administración & dosificación , Farmacorresistencia Bacteriana Múltiple , Transferencia de Gen Horizontal , Infecciones por Klebsiella/microbiología , Klebsiella pneumoniae/efectos de los fármacos , Plásmidos/análisis , Profilaxis Antibiótica/métodos , Trasplante de Células Madre Hematopoyéticas , Humanos , Klebsiella pneumoniae/aislamiento & purificación , Selección Genética , Receptores de Trasplantes
15.
Biol Blood Marrow Transplant ; 25(1): 172-178, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30098394

RESUMEN

Product safety assurance is crucial for the clinical use of manufactured cellular therapies. A rational approach for delivering products that fail release criteria (because of potentially false-positive sterility results) is important to avoid unwarranted wastage of highly personalized and costly therapies in critically ill patients where benefits may outweigh risk. Accurate and timely interpretation of microbial sterility assays represents a major challenge in cell therapies. We developed a systematic protocol for the assessment of positive microbial sterility test results using retrospective data from 2007 to 2016. This protocol was validated and applied prospectively between October 2016 and September 2017 to 13 products from which positive sterility results had been reported. Viable and nonviable environmental monitoring (EM) data were collected concurrently as part of a facility control assessment. Three of 13 (23%) positive sterility results were attributable to bone marrow collections that had been contaminated with skin flora during harvest; all were infused without pertinent infectious sequelae. Of the remaining 10, 1 was deemed a true positive and was discarded before infusion, whereas 9 were classified as false positives attributed to laboratory sampling and/or culturing processes. Three products deemed false positive were infused and 6 were withheld because of patient issues unrelated to microbial sterility results. No postinfusion-associated infectious complications were documented. Almost half of the positive EM findings were skin flora. Paired detection of an organism in both product and associated EM was identified in 1 case. Application of our validated protocol to positive product sterility test results allowed for systematic data compilation for regulatory evaluation and provided comprehensive information to clinical investigators to ensure timely and strategic management for product recipients.


Asunto(s)
Células Sanguíneas , Tratamiento Basado en Trasplante de Células y Tejidos , Desinfección , Control de Calidad , Células Sanguíneas/microbiología , Células Sanguíneas/virología , Humanos , Estudios Retrospectivos
16.
J Clin Microbiol ; 57(2)2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30541938

RESUMEN

The emergence of cell therapy programs in large academic centers has led to an increasing demand for clinical laboratories to assist with product sterility testing. Automated blood culture systems have shown promise as alternatives to the manual USP<71> compendial method, but current published data are limited by small organism test sets, particularly for molds. In 2015, failure of the Bactec FX system to detect mold contamination in two products prompted us to evaluate three test systems (compendial USP<71>, Bactec FX, and BacT/Alert Dual-T) over seven different culture combinations, using 118 challenge organisms representative of the NIH current good manufacturing practice (cGMP) environment. At <96 h and <144 h for bacterial and fungal detection, respectively, the compendial USP<71> method significantly outperformed the Bactec FX system (84.7% versus 64.4%; P = 0.0006) but not the BacT/Alert system at 32.5°C (78.8%; P = 0.3116). Extended incubation to 360 h with terminal visual inspection improved sensitivity, without a significant difference between compendial USP<71> and BacT/Alert testing (95.7% versus 89.0%; P = 0.0860); both systems were better than the Bactec FX system (71.2%; P < 0.0001 and P = 0.0003, respectively). The Bactec FX and BacT/Alert systems performed equivalently for 30 isolates derived from clinical bloodstream infections, confirming system optimization for clinical organisms rather than environmental contaminants. Paired Sabouraud dextrose agar (SDA) plates were always positive for fungi within the acceptable time frame. This study shows that the Bactec FX system is suboptimal for product sterility testing, and it provides strong data to support the use of BacT/Alert testing at 32.5°C paired with a supplemental SDA plate as an acceptable alternative to the compendial USP<71> method for product sterility testing.


Asunto(s)
Tratamiento Basado en Trasplante de Células y Tejidos/efectos adversos , Contaminación de Medicamentos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/prevención & control , Técnicas Microbiológicas/métodos , Tratamiento Basado en Trasplante de Células y Tejidos/métodos , Sensibilidad y Especificidad
17.
N Engl J Med ; 379(26): 2529-2539, 2018 12 27.
Artículo en Inglés | MEDLINE | ID: mdl-30586509

RESUMEN

BACKGROUND: Plumbing systems are an infrequent but known reservoir for opportunistic microbial pathogens that can infect hospitalized patients. In 2016, a cluster of clinical sphingomonas infections prompted an investigation. METHODS: We performed whole-genome DNA sequencing on clinical isolates of multidrug-resistant Sphingomonas koreensis identified from 2006 through 2016 at the National Institutes of Health (NIH) Clinical Center. We cultured S. koreensis from the sinks in patient rooms and performed both whole-genome and shotgun metagenomic sequencing to identify a reservoir within the infrastructure of the hospital. These isolates were compared with clinical and environmental S. koreensis isolates obtained from other institutions. RESULTS: The investigation showed that two isolates of S. koreensis obtained from the six patients identified in the 2016 cluster were unrelated, but four isolates shared more than 99.92% genetic similarity and were resistant to multiple antibiotic agents. Retrospective analysis of banked clinical isolates of sphingomonas from the NIH Clinical Center revealed the intermittent recovery of a clonal strain over the past decade. Unique single-nucleotide variants identified in strains of S. koreensis elucidated the existence of a reservoir in the hospital plumbing. Clinical S. koreensis isolates from other facilities were genetically distinct from the NIH isolates. Hospital remediation strategies were guided by results of microbiologic culturing and fine-scale genomic analyses. CONCLUSIONS: This genomic and epidemiologic investigation suggests that S. koreensis is an opportunistic human pathogen that both persisted in the NIH Clinical Center infrastructure across time and space and caused health care-associated infections. (Funded by the NIH Intramural Research Programs.).


Asunto(s)
Infección Hospitalaria/microbiología , Reservorios de Enfermedades/microbiología , Infecciones por Bacterias Gramnegativas/microbiología , Ingeniería Sanitaria , Sphingomonas/genética , Antibacterianos/farmacología , Hospitales Federales , Humanos , Metagenómica , Pruebas de Sensibilidad Microbiana , National Institutes of Health (U.S.) , Estudios Retrospectivos , Sphingomonas/efectos de los fármacos , Sphingomonas/aislamiento & purificación , Estados Unidos , Abastecimiento de Agua , Secuenciación Completa del Genoma
18.
mBio ; 9(1)2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29437920

RESUMEN

The hospital environment is a potential reservoir of bacteria with plasmids conferring carbapenem resistance. Our Hospital Epidemiology Service routinely performs extensive sampling of high-touch surfaces, sinks, and other locations in the hospital. Over a 2-year period, additional sampling was conducted at a broader range of locations, including housekeeping closets, wastewater from hospital internal pipes, and external manholes. We compared these data with previously collected information from 5 years of patient clinical and surveillance isolates. Whole-genome sequencing and analysis of 108 isolates provided comprehensive characterization of blaKPC/blaNDM-positive isolates, enabling an in-depth genetic comparison. Strikingly, despite a very low prevalence of patient infections with blaKPC-positive organisms, all samples from the intensive care unit pipe wastewater and external manholes contained carbapenemase-producing organisms (CPOs), suggesting a vast, resilient reservoir. We observed a diverse set of species and plasmids, and we noted species and susceptibility profile differences between environmental and patient populations of CPOs. However, there were plasmid backbones common to both populations, highlighting a potential environmental reservoir of mobile elements that may contribute to the spread of resistance genes. Clear associations between patient and environmental isolates were uncommon based on sequence analysis and epidemiology, suggesting reasonable infection control compliance at our institution. Nonetheless, a probable nosocomial transmission of Leclercia sp. from the housekeeping environment to a patient was detected by this extensive surveillance. These data and analyses further our understanding of CPOs in the hospital environment and are broadly relevant to the design of infection control strategies in many infrastructure settings.IMPORTANCE Carbapenemase-producing organisms (CPOs) are a global concern because of the morbidity and mortality associated with these resistant Gram-negative bacteria. Horizontal plasmid transfer spreads the resistance mechanism to new bacteria, and understanding the plasmid ecology of the hospital environment can assist in the design of control strategies to prevent nosocomial infections. A 5-year genomic and epidemiological survey was undertaken to study the CPOs in the patient-accessible environment, as well as in the plumbing system removed from the patient. This comprehensive survey revealed a vast, unappreciated reservoir of CPOs in wastewater, which was in contrast to the low positivity rate in both the patient population and the patient-accessible environment. While there were few patient-environmental isolate associations, there were plasmid backbones common to both populations. These results are relevant to all hospitals for which CPO colonization may not yet be defined through extensive surveillance.


Asunto(s)
Proteínas Bacterianas/genética , Enterobacteriaceae Resistentes a los Carbapenémicos/aislamiento & purificación , Plásmidos/análisis , Ingeniería Sanitaria , Microbiología del Agua , beta-Lactamasas/genética , Enterobacteriaceae Resistentes a los Carbapenémicos/genética , Hospitales , Humanos , Metagenómica , Prevalencia , Secuenciación Completa del Genoma
19.
Malar J ; 17(1): 23, 2018 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-29321025

RESUMEN

BACKGROUND: Autosplenectomy, as a result of sickle cell disease, is an important risk factor for severe malaria. While molecular methods are helpful in providing rapid and accurate infection detection and species identification, the effect of hyposplenism on result interpretation during the course of infection should be carefully considered. CASE PRESENTATION: A 32-year old autosplenectomized Nigerian male with severe sickle cell disease was referred to the National Institutes of Health for allogenic hematopoietic stem cell transplant. Despite testing negative for malaria by both smear and PCR 2 weeks after arrival in the USA, the patient developed fever and diffuse bilateral lower rib cage and upper abdominal pain 2 weeks later and subsequently tested positive for Plasmodium falciparum. Parasitaemia was tracked over time by microscopy and nucleic acid tests to evaluate the therapeutic response in the setting of hyposplenism. The patient showed prompt resolution of patent infection by microscopy but remained positive by molecular methods for > 30 days after treatment initiation. CONCLUSION: While molecular testing can provide sensitive Plasmodium nucleic acid detection, the persistence of Plasmodium nucleic acids following adequate treatment in functionally asplenic patients can lead to a diagnostic dilemma. In such patients, clinical response and peripheral blood smears should guide patient management following treatment. Nonetheless, in pre-transplant patients at high-risk for pre-existing Plasmodium infections, highly sensitive molecular assays can be useful to rule out infection prior to transplantation.


Asunto(s)
Anemia de Células Falciformes/complicaciones , Antimaláricos/uso terapéutico , ADN Protozoario/sangre , Monitoreo de Drogas/métodos , Malaria Falciparum/diagnóstico , Malaria Falciparum/patología , Adulto , Humanos , Malaria Falciparum/tratamiento farmacológico , Masculino , Microscopía , Ácidos Nucleicos , Reacción en Cadena de la Polimerasa , Factores de Tiempo , Estados Unidos