Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Rev Med Chil ; 152(1): 36-48, 2024 Jan.
Artículo en Español | MEDLINE | ID: mdl-39270095

RESUMEN

INTRODUCTION: The COVID-19 pandemic marked a milestone in the history of medicine worldwide. Together with the humanitarian drama it represented, the problems that arose are promoting lines of research in multiple fields. One of these fields is the aspects related to medical communication and end-of-life care. This paper reports the experiences and perceptions of relatives of patients who died during the pandemic with a psychospiritual support intervention in a public hospital in the Metropolitan Region, Chile, called "farewell". METHODS: A qualitative study was conducted with a phenomenological approach based on in-depth interviews. From this, categories were derived that allowed a systematization of the observation of the experiences. RESULTS: Among the results, the impact of the circumstances and the communication provided by the medical team on grief should be highlighted. The use of the word "farewell" emerges as a useful, albeit ambiguous, communicative tool when it comes to adequately framing an end-of-life process. CONCLUSIONS: It is argued that the end of life is an area that requires physical and psychospiritual spaces, and adequate training at all levels to do justice to a highly relevant moment in the care of people.


Asunto(s)
COVID-19 , Familia , Investigación Cualitativa , Cuidado Terminal , Humanos , COVID-19/psicología , COVID-19/epidemiología , Chile/epidemiología , Familia/psicología , Cuidado Terminal/psicología , Masculino , Femenino , SARS-CoV-2 , Actitud Frente a la Muerte , Adulto , Pandemias , Persona de Mediana Edad , Pesar , Entrevistas como Asunto , Anciano , Comunicación
2.
Biosensors (Basel) ; 13(7)2023 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-37504106

RESUMEN

In this scientific work, we demonstrate, for the first time, a new biosensing system and procedure to measure specifically the total Tau (T-Tau) protein in serum, one of the most relevant biomarkers of Alzheimer's disease (AD). AD is a progressive brain disorder that produces neuronal and cognitive dysfunction and affects a high percentage of people worldwide. For this reason, diagnosing AD at the earliest possible stage involves improving diagnostic systems. We report on the use of interferometric bio-transducers integrated with 65 microwells forming diagnostic KITs read-out by using the Interferometric Optical Detection Method (IODM). Moreover, biofunctionalized silicon dioxide (SiO2) nanoparticles (NPs) acting as interferometric enhancers of the bio-transducers signal allow for the improvement of both the optical read-out signal and its ability to work with less-invasive biological samples such as serum instead of cerebrospinal fluid (CSF). As a result, in this paper, we describe for the first time a relevant diagnostic alternative to detect Tau protein at demanding concentrations of 10 pg/mL or even better, opening the opportunity to be used for detecting other relevant AD-related biomarkers in serum, such as ß-amyloid and phosphorylated Tau (P-Tau), neurofilaments, among others that can be considered relevant for AD.


Asunto(s)
Enfermedad de Alzheimer , Nanopartículas , Humanos , Enfermedad de Alzheimer/diagnóstico , Dióxido de Silicio , Proteínas tau , Péptidos beta-Amiloides , Biomarcadores , Fragmentos de Péptidos/líquido cefalorraquídeo
3.
Sensors (Basel) ; 20(17)2020 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-32847025

RESUMEN

Interferon-gamma (IFN-γ) is a cytokine associated with inflammatory diseases, virus, infection, etc. The quantification of interferon-gamma concentration levels is studied to relate the immune system response to the progression of disease. In this work, we used a label-free point-of-care device based on the increase relative optical power (IROP) and a biosensor based on photonic transducers called BICELLs (Biophotonic Sensing Cells) to evaluate interferon-gamma concentrations. The BICELLs' sensing surface size used is 100 µm in diameter. The bioreceptor is attached to the surface by streptavidin-biotin affinity. This label-free IROP-based device can work with a low concentration of reagents and a low sample volume for measurements. Furthermore, this new device was compared with an ELISA technique in the same conditions. A good correlation was achieved between both techniques. This device is easy to use, and it is a cost-effective tool for monitoring an analyte in a disease.


Asunto(s)
Técnicas Biosensibles , Ensayo de Inmunoadsorción Enzimática , Interferón gamma , Interferometría , Sistemas de Atención de Punto
4.
Anal Bioanal Chem ; 412(14): 3285-3297, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32055908

RESUMEN

In this work, we review the technology of vertically interrogated optical biosensors from the point of view of engineering. Vertical sensors present several advantages in the fabrication processes and in the light coupling systems, compared with other interferometric sensors. Four different interrelated aspects of the design are identified and described: sensing cell design, optical techniques used in the interrogation, fabrication processes, fluidics, and biofunctionalization of the sensing surface. The designer of a vertical sensor should decide carefully which solution to adopt on each aspect prior to finally integrating all the components in a single platform. Complexity, cost, and reliability of this platform will be determined by the decisions taken on each of the design process. We focus on the research and experience acquired by our group during last years in the field of optical biosensors.


Asunto(s)
Técnicas Biosensibles/instrumentación , Dispositivos Ópticos , Animales , Técnicas Biosensibles/métodos , Diseño de Equipo , Humanos , Interferometría/instrumentación , Interferometría/métodos , Luz
5.
Sensors (Basel) ; 18(7)2018 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-29949904

RESUMEN

A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations.


Asunto(s)
Técnicas Biosensibles/normas , Límite de Detección , Incertidumbre , Calibración , Reproducibilidad de los Resultados
6.
Sensors (Basel) ; 17(5)2017 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-28534808

RESUMEN

A novel compact optical biochip based on a thin layer-sensing surface of nitrocellulose is used for in-situ label-free detection of metalloproteinase (MMP9) related to dry eye disease. In this article, a new integrated chip with different interferometric transducers layout with an optimal sensing surface is reported for the first time. We demonstrate that specific antibodies can be immobilized onto these transducers with a very low volume of sample and with good orientation. Many sensing transducers constitute the presented biochip in order to yield statistical data and stability in the acquired measurements. As a result, we report the recognition curve for pure recombinant MMP9, tests of model tears with MMP9, and real tear performance from patients, with a promising limit of detection.


Asunto(s)
Síndromes de Ojo Seco , Técnicas Biosensibles , Colodión , Humanos , Interferometría , Metaloproteinasa 9 de la Matriz , Transductores
7.
Sensors (Basel) ; 15(8): 19819-29, 2015 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-26287192

RESUMEN

The specificity and affinity of antibody-antigen interactions is a fundamental way to achieve reliable biosensing responses. Different proteins involved with dry eye dysfunction: ANXA1, ANXA11, CST4, PRDX5, PLAA and S100A6; were validated as biomarkers. In this work several antibodies were tested for ANXA1, ANXA11 and PRDX5 to select the best candidates for each biomarker. The results were obtained by using Biophotonic Sensing Cells (BICELLs) as an efficient methodology for label-free biosensing and compared with the Enzyme-Linked Immuno Sorbent Assay (ELISA) technique.


Asunto(s)
Afinidad de Anticuerpos/inmunología , Antígenos/metabolismo , Biomarcadores/análisis , Técnicas Biosensibles/métodos , Síndromes de Ojo Seco/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Animales , Anexinas/inmunología , Anticuerpos Monoclonales/metabolismo , Calibración , Femenino , Cinética , Ratones Endogámicos BALB C , Fenómenos Ópticos , Coloración y Etiquetado
8.
Sensors (Basel) ; 14(4): 6695-700, 2014 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-24727502

RESUMEN

In this communication we report a direct immunoassay for detecting dengue virus by means of a label-free interferometric optical detection method. We also demonstrate how we can optimize this sensing response by adding a blocking step able to significantly enhance the optical sensing response. The blocking reagent used for this optimization is a dry milk diluted in phosphate buffered saline. The recognition curve of dengue virus over the proposed surface sensor demonstrates the capacity of this method to be applied in Point of Care technology.


Asunto(s)
Virus del Dengue/inmunología , Virus del Dengue/aislamiento & purificación , Inmunoensayo/métodos , Interferometría/métodos , Óptica y Fotónica/métodos , Técnicas Biosensibles , Coloración y Etiquetado
9.
Sensors (Basel) ; 14(2): 3675-89, 2014 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-24566633

RESUMEN

In this article we report a new, simple, and reliable optical read-out detection method able to assess Rotavirus present in human sera as well as in the viral pollution sources. It is based on the interference of two interferometers used as biophotonic transducers. The method significantly improves the optical label-free biosensing response measuring both, the concentration of the AgR and its corresponding size. Two different immunoassays were carried out: Bovine Serum Albumin (BSA), and the recognition by its antibody (anti-BSA); and Rotavirus (AgR) and the recognition by its antibody (anti-AgR). In the cases studied, and using as model interferometer a simple Fabry-Perot transducer, we demonstrate a biosensing enhancement of two orders of magnitude in the Limit of Detection (LoD). In fact, this read-out optical method may have significant implications to enhance other optical label-free photonic transducers reported in the scientific literature.


Asunto(s)
Técnicas Biosensibles , Rotavirus/aislamiento & purificación , Albúmina Sérica Bovina/análisis , Animales , Anticuerpos/química , Anticuerpos/inmunología , Bovinos , Humanos , Inmunoensayo , Interferometría , Luz , Fotones , Rotavirus/inmunología , Albúmina Sérica Bovina/inmunología , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA