Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Int J Comput Assist Radiol Surg ; 18(10): 1819-1828, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37072657

RESUMEN

PURPOSE: Radiofrequency ablation (RFA) is a curative treatment option for small lung metastases, which conventionally involves multiple freehand manipulations until the treating electrode is satisfactorily positioned. Stereotactic and robotic guidance has been gaining popularity for liver ablation, although has not been established in lung ablation. The purpose of this study is to determine the feasibility, safety, and accuracy of robotic RFA for pulmonary metastases, and compare procedures with a conventional freehand cohort. METHODS: A single center study with prospective robotic cohort, and retrospective freehand cohort. RFA was performed under general anesthesia using high frequency jet ventilation and CT guidance. Main outcomes were (i) feasibility/technical success (ii) safety using Common Terminology Criteria for Adverse Events (iii) targeting accuracy (iv) number of needle manipulations for satisfactory ablation. Robotic and freehand cohorts were compared using Mann-Whitney U tests for continuous variables, and Fisher's exact for categorical variables. RESULTS: Thirty-nine patients (mean age 65 ± 13 years, 20 men) underwent ablation of 44 pulmonary metastases at single specialist cancer center between July 2019 and August 2022. 20 consecutive participants underwent robotic ablation, and 20 consecutive patients underwent freehand ablation. All 20/20 (100%) robotic procedures were technically successful, and none were converted to freehand procedures. There were 6/20 (30%) adverse events in the robotic cohort, and 15/20 (75%) in the freehand cohort (P = 0.01). Robotic placement was highly accurate with 6 mm tip-to-target distance (range 0-14 mm) despite out-of-plane approaches, with fewer manipulations than freehand placement (median 0 vs. 4.5 manipulations, P < 0.001 and 7/22, 32% vs. 22/22, 100%, P < 0.001). CONCLUSIONS: Robotic radiofrequency ablation of pulmonary metastases with general anesthesia and high frequency jet ventilation is feasible and safe. Targeting accuracy is high, and fewer needle/electrode manipulations are required to achieve a satisfactory position for ablation than freehand placement, with early indications of reduced complications.


Asunto(s)
Ablación por Catéter , Neoplasias Pulmonares , Ablación por Radiofrecuencia , Procedimientos Quirúrgicos Robotizados , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios de Cohortes , Estudios Prospectivos , Ablación por Catéter/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pulmonares/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
2.
Oncotarget ; 7(47): 76471-76478, 2016 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-27835611

RESUMEN

Cobalt-containing metal-on-metal hip replacements are associated with adverse reactions to metal debris (ARMD), including inflammatory pseudotumours, osteolysis, and aseptic implant loosening. The exact cellular and molecular mechanisms leading to these responses are unknown. Cobaltions (Co2+) activate human Toll-like receptor 4 (TLR4), an innate immune receptor responsible for inflammatory responses to Gram negative bacterial lipopolysaccharide (LPS).We investigated the effect of Co2+-mediated TLR4 activation on human microvascular endothelial cells (HMEC-1), focusing on the secretion of key inflammatory cytokines and expression of adhesion molecules. We also studied the role of TLR4 in Co2+-mediated adhesion molecule expression in MonoMac 6 macrophages.We show that Co2+ increases secretion of inflammatory cytokines, including IL-6 and IL-8, in HMEC-1. The effects are TLR4-dependent as they can be prevented with a small molecule TLR4 antagonist. Increased TLR4-dependent expression of intercellular adhesion molecule 1 (ICAM1) was also observed in endothelial cells and macrophages. Furthermore, we demonstrate for the first time that Co2+ activation of TLR4 upregulates secretion of a soluble adhesion molecule, sICAM-1, in both endothelial cells and macrophages. Although sICAM-1 can be generated through activity of matrix metalloproteinase-9 (MMP-9), we did not find any changes in MMP9 expression following Co2+ stimulation.In summary we show that Co2+ can induce endothelial inflammation via activation of TLR4. We also identify a role for TLR4 in Co2+-mediated changes in adhesion molecule expression. Finally, sICAM-1 is a novel target for further investigation in ARMD studies.


Asunto(s)
Cobalto/farmacología , Células Endoteliales/efectos de los fármacos , Células Endoteliales/metabolismo , Inflamación/etiología , Inflamación/metabolismo , Receptor Toll-Like 4/agonistas , Citocinas/metabolismo , Activación Enzimática , Expresión Génica , Humanos , Mediadores de Inflamación/metabolismo , Molécula 1 de Adhesión Intercelular/genética , Molécula 1 de Adhesión Intercelular/metabolismo , Macrófagos/efectos de los fármacos , Macrófagos/metabolismo , Metaloproteinasa 9 de la Matriz/genética , Metaloproteinasa 9 de la Matriz/metabolismo
3.
J Man Manip Ther ; 24(1): 21-5, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27252579

RESUMEN

OBJECTIVE: To determine the correlation between the Quebec Task Force Classification (QTFC) system and outcome in patients with non-specific low back pain (LBP). METHODS: Forty-nine patients who were treated in outpatient physical therapy clinics of Catholic Health System (CHS) of Western New York (WNY) were classified according to the QTFC at the initial examination by physical therapists (PTs) with training in Mechanical Diagnosis and Therapy (MDT). The patient's perceived level of function was assessed with the Focus On Therapeutic Outcomes (FOTO) tool at the initial examination, 2 weeks following the initiation of physical therapy and again at discharge. RESULTS: A linear regression model between acuity and change in FOTO score was performed and demonstrated statistical significance (P<0·05) as the more favorable outcome was found with the more acute patients. Spearman correlations between change in FOTO score and QTFC, duration of treatment and acuity of condition, and number of visits and change in FOTO score were not found to be statistically significant. CONCLUSIONS: The patients treated in this study demonstrated functional improvement in an average of eight visits, indicating efficacious care. Future research is needed to determine prioritized intervention strategies for designated LBP classifications.

4.
Oncotarget ; 7(7): 7578-85, 2016 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-26840091

RESUMEN

Cobalt-chrome alloy is a widely used biomaterial in joint replacements, dental implants and spinal rods. Although it is an effective and biocompatible material, adverse reactions to metal debris (ARMD) have arisen in a minority of patients, particularly in those with metal-on-metal bearing hip replacements. There is currently no treatment for ARMD and once progressive, early revision surgery of the implant is necessary. Therapeutic agents to prevent, halt or reverse ARMD would therefore be advantageous. Cobalt ions activate Toll-like receptor 4 (TLR4), an innate immune receptor responsible for inflammatory responses to bacterial lipopolysaccharide (LPS) resulting in the production of pro-inflammatory cytokines and chemokines. We hypothesised that anti-TLR4 neutralising antibodies, reported to inhibit TLR4-mediated inflammation, could prevent the inflammatory response to cobalt ions in an in vitro macrophage cell culture model. This study shows that a monoclonal anti-TLR4 antibody inhibited cobalt-mediated increases in pro-inflammatory IL8, CCL20 and IL1A expression, as well as IL-8 secretion. In contrast, a polyclonal antibody did not prevent the effect of cobalt ions on either IL-8 or IL1A expression, although it did have a small effect on the CCL20 response. Interestingly, both antibodies inhibited cobalt-mediated neutrophil migration although the greater effect was observed with the monoclonal antibody. In summary our data shows that a monoclonal anti-TLR4 antibody can inhibit cobalt-mediated inflammatory responses while a polyclonal antibody only inhibits the effect of specific cytokines. Anti-TLR4 antibodies have therapeutic potential in ARMD although careful antibody design is required to ensure that the LPS response is preserved.


Asunto(s)
Anticuerpos Monoclonales/farmacología , Cobalto/efectos adversos , Inflamación/prevención & control , Leucemia Monocítica Aguda/tratamiento farmacológico , Macrófagos/efectos de los fármacos , Receptor Toll-Like 4/antagonistas & inhibidores , Anticuerpos Neutralizantes/farmacología , Apoptosis/efectos de los fármacos , Movimiento Celular/efectos de los fármacos , Quimiocinas/genética , Quimiocinas/metabolismo , Citocinas/genética , Citocinas/metabolismo , Ensayo de Inmunoadsorción Enzimática , Humanos , Inflamación/inducido químicamente , Inflamación/patología , Mediadores de Inflamación/metabolismo , Leucemia Monocítica Aguda/patología , Macrófagos/metabolismo , Macrófagos/patología , ARN Mensajero/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Oligoelementos/efectos adversos , Células Tumorales Cultivadas
5.
Biochem Biophys Rep ; 7: 374-378, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28955928

RESUMEN

Metal-on-metal (MoM) hip replacements, often manufactured from a cobalt-chrome alloy, are associated with adverse reactions including soft tissue necrosis and osteolysis. Histopathological analysis of MoM peri-implant tissues reveals an inflammatory cell infiltrate that includes macrophages, monocytes and neutrophils. Toll-like receptor 4 (TLR4) is an innate immune receptor activated by bacterial lipopolysaccharide. Recent studies have demonstrated that cobalt ions from metal-on-metal joints also activate human TLR4, increasing cellular secretion of inflammatory chemokines including interleukin-8 (IL-8, CXCL8) and CCL2. Chemokines recruit immune cells to the site of inflammation, and their overall effect depends on the chemokine profile produced. This study investigated the effect of cobalt on the secretion of inflammatory cytokines CCL20 and IL-6. The chemotactic potential of conditioned media from a cobalt-stimulated human monocyte cell line on primary monocytes and neutrophils was investigated using an in vitro transwell migration assay. The role of TLR4 in observed effects was studied using a small molecule TLR4-specific antagonist. Cobalt ions significantly increased release of CCL2 and IL-6 by MonoMac 6 cells (P<0.001). Conditioned media from cobalt-stimulated cells significantly increased monocyte and neutrophil chemotaxis in vitro (P<0.001). These effects were abrogated by the TLR4 antagonist (P<0.001) suggesting that they occur through cobalt activation of TLR4. This study demonstrates the role of TLR4 in cobalt-mediated immune cell chemotaxis and provides a potential mechanism by which cobalt ions may contribute to the immune cell infiltrate surrounding failed metal hip replacements. It also highlights the TLR4 signalling pathway as a potential therapeutic target in preventing cobalt-mediated inflammation.

8.
J Forensic Sci ; 56(6): 1457-63, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21883207

RESUMEN

Successful mitochondrial DNA (mtDNA) forensic analysis depends on sufficient quantity and quality of mtDNA. A real-time quantitative PCR assay was developed to assess such characteristics in a DNA sample, which utilizes a duplex, synthetic DNA to ensure optimal quality assurance and quality control. The assay's 105-base pair target sequence facilitates amplification of degraded DNA and is minimally homologous to nonhuman mtDNA. The primers and probe hybridize to a region that has relatively few sequence polymorphisms. The assay can also identify the presence of PCR inhibitors and thus indicate the need for sample repurification. The results show that the assay provides information down to 10 copies and provides a dynamic range spanning seven orders of magnitude. Additional experiments demonstrated that as few as 300 mtDNA copies resulted in successful hypervariable region amplification, information that permits sample conservation and optimized downstream PCR testing. The assay described is rapid, reliable, and robust.


Asunto(s)
Dermatoglifia del ADN/normas , ADN Mitocondrial/análisis , Animales , Regiones Determinantes de Complementariedad/genética , Cartilla de ADN , Sondas de ADN , Humanos , Modelos Lineales , Control de Calidad , Reacción en Cadena en Tiempo Real de la Polimerasa , Reproducibilidad de los Resultados , Análisis de Secuencia de ADN , Especificidad de la Especie
9.
Fam Pract ; 25(4): 221-7, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18573803

RESUMEN

BACKGROUND: The epidemiology of melanoma is changing and its current management is variable, with some lesions being removed in general practice. We aimed to determine the quality of excision and time to diagnosis relating to the excising surgeon and the place of excision. METHOD: Analysis of data from the North Wales Melanoma Database. RESULTS: In total, 578 cases were diagnosed 1993-2001. There was a gender difference with anatomical location, with 107 (65%) males with lesions on their trunk compared to 57 (35%) females. Median Breslow thickness was 1.10 mm (range 0.05-16.0 mm). Ninety-five (16%) lesions were removed in general practice, of which 49 (52%) were referred on to hospital. In total, 266 (61%) lesions were excised with 'adequate' margins and 170 (39%) excised with margins narrower than the guidelines. General practice excisions were from a younger group than hospital excisions. There were no differences in quality of excision between general practice and hospital excisions. Time to diagnosis was shorter overall for general practice excisions than hospital excisions (median 12 versus 41 days, P < 0.001). CONCLUSION: These findings are of policy importance in that there is no evidence from this study that general practice excisions are managed poorly or have a worse prognosis.


Asunto(s)
Medicina Familiar y Comunitaria/normas , Oncología Médica/normas , Melanoma/cirugía , Procedimientos Quirúrgicos Operativos/normas , Adulto , Anciano , Estudios de Cohortes , Supervivencia sin Enfermedad , Femenino , Humanos , Modelos Logísticos , Masculino , Melanoma/epidemiología , Melanoma/patología , Persona de Mediana Edad , Recurrencia Local de Neoplasia/epidemiología , Garantía de la Calidad de Atención de Salud , Sistema de Registros , Procedimientos Quirúrgicos Operativos/métodos , Gales/epidemiología
10.
BMC Fam Pract ; 9: 9, 2008 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-18234092

RESUMEN

BACKGROUND: There is no validated way of measuring diagnostic delay in cancer, especially covering patient and primary care delays. An instrument is needed in order to determine the effect of potential interventions to reduce delay and improve cancer morbidity and mortality. METHODS: Development of a postal questionnaire tool to measure patient and primary care time responses to key symptoms and signs. The pilot questionnaire was sent to 184 patients with suspected cancer. RESULTS: The response rate was only 85/184 (46.2%). Anxiety was cited as one reason for this low response. Patients returning questionnaires were more likely to be women and more likely to be younger. 84/85 (98.8%) provided consent to access medical records, and questions regarding health profile, smoking and socio-economic profile were answered adequately. Outcome data on their cancer diagnosis was linked satisfactorily and the question about GP-initiated investigations was answered well. Estimated dates for symptom duration were preferred for patient delays, but exact dates were preferred for primary care delays; however there was a significant amount of missing data. CONCLUSION: A more personal approach to the collection of data about the duration of symptoms in this group of people is needed other than a postal questionnaire. However elements of this piloted questionnaire are likely to figure strongly in future development and evaluation of this tool.


Asunto(s)
Encuestas de Atención de la Salud/métodos , Neoplasias/diagnóstico , Aceptación de la Atención de Salud/estadística & datos numéricos , Atención Primaria de Salud/normas , Encuestas y Cuestionarios , Adulto , Anciano , Anciano de 80 o más Años , Medicina Familiar y Comunitaria/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/terapia , Aceptación de la Atención de Salud/psicología , Proyectos Piloto , Derivación y Consulta , Estudios Retrospectivos , Factores de Tiempo , Gales
12.
Vet Dermatol ; 16(4): 253-60, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16101796

RESUMEN

Dermatophagoides farinae is a frequent allergen in canine atopic dermatitis despite its reported scarcity in the UK, and the aim of this study was to determine whether dogs were uniquely exposed to this species. Der f 1 and Der p 1 in dust collected from living room carpets, bedroom carpets and dog beds of 13 houses with no dogs, 13 with healthy dogs, and 16 with Dermatophagoides-sensitized atopic dogs were quantified by ELISA. Der p 1 levels (microg g(-1) house dust) were significantly higher than Der f 1 in living rooms (Der p 1 median = 1.9, 95% CI = 2.05-6.32, n = 42; Der f 1 median = 0.07, 95% CI = 0.01-0.06, n = 42), bedrooms (Der p 1 median = 4.35, SD = 5.52; Der f 1 median = 0.01, 95% CI = 0.001-0.1, n = 42) and dog beds (Der p 1 median = 1.04, 95% CI = 1.4-8.1, n = 29; Der f 1 median = 0.008, 95% CI = 0.01-0.04, n = 29) (P < 0.0001). Living rooms in houses without dogs had significantly greater Der p 1 levels (median = 7.0, 95% CI = 3.53-15.8, n = 13) than houses with healthy (median = 1.19, 95% CI = 0.44-3.49, n = 13) or atopic dogs (median = 0.78, 95% CI = 0.63-2.42, n = 16) (P = 0.0004). Environmental flea control in living rooms and washing dog beds was associated with significantly reduced Der p 1 levels. This confirms that D. pteronyssinus is common but D. farinae is rare in the sampling area. Apparent sensitization to D. farinae is probably due to cross-reaction. A combination of environmental measures could reduce allergen exposure.


Asunto(s)
Antígenos Dermatofagoides/inmunología , Dermatitis Atópica/veterinaria , Enfermedades de los Perros/epidemiología , Enfermedades de los Perros/inmunología , Polvo , Animales , Antígenos Dermatofagoides/análisis , Proteínas de Artrópodos , Estudios de Casos y Controles , Cisteína Endopeptidasas , Dermatitis Atópica/inmunología , Perros , Inglaterra/epidemiología , Vivienda para Animales , Prevalencia
13.
J Forensic Sci ; 47(4): 811-8, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12136989

RESUMEN

Mitochondrial DNA (mtDNA) analysis of forensic samples typically is performed when the quantity and quality of DNA are insufficient for nuclear DNA analysis or when maternal relatives may be the only reference source. Many of the steps required in the analytical process are both lengthy and labor intensive. Therefore, improvements in the process that reduce labor without compromising the quality of the data are desirable. The current procedure requires purification of the amplicons by centrifugal filtration after PCR and prior to cycle sequencing. Because this method requires several manipulations to perform, alternate cleanup procedures were investigated. These include the use of 1) Qiagen QlAquick PCR Purification columns, 2) Concert Rapid PCR Purification columns, and 3) ExoSAP-IT reagent. When the yield of purified amplicons, quality of the sequence profile, and ease of assay were evaluated, the use of ExoSAP-IT reagent for post-amplification purification was chosen to replace the filtration method.


Asunto(s)
ADN Mitocondrial/genética , Reacción en Cadena de la Polimerasa/métodos , Análisis de Secuencia de ADN/métodos , ADN Mitocondrial/aislamiento & purificación , Femenino , Medicina Legal/métodos , Humanos , Control de Calidad , Valores de Referencia , Manejo de Especímenes , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...