Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Biomech ; 168: 112110, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38677025

RESUMEN

Rotator cuff (RC) tears are a common source of pain and decreased shoulder strength. Muscle length is known to affect muscle strength, and therefore evaluating changes in supraspinatus muscle length associated with RC pathology, surgical repair, and post-operative recovery may provide insights into functional deficits. Our objective was to develop a reliable MRI-based approach for assessing supraspinatus muscle length. Using a new semi-automated approach for identifying 3D location of the muscle-tendon junction (MTJ), supraspinatus muscle length was calculated as the sum of MTJ distance (distance between 3D MTJ position and glenoid plane) and supraspinatus fossa length (distance between root of the scapular spine and glenoid plane). Inter- and intra-operator reliability of this technique were assessed with intraclass correlation coefficient (ICC) and found to be excellent (ICCs > 0.96). Muscle lengths of 6 patients were determined before RC repair surgery and at 3- and 12-months post-surgery. Changes in normalized muscle length (muscle length as a percentage of pre-surgical muscle length) at 3 months post-surgery varied considerably across patients (16.1 % increase to 7.0 % decrease) but decreased in all patients from 3- to 12-months post-surgery (0.3 % to 17.2 %). This study developed a novel and reliable approach for quantifying supraspinatus muscle length and provided preliminary demonstration of its utility by assessing muscle length changes associated with RC pathology and surgical repair. Future studies can use this technique to evaluate changes over time in supraspinatus muscle length in response to clinical intervention, and associations between muscle length and shoulder function.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Humanos , Imagen por Resonancia Magnética/métodos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Manguito de los Rotadores/fisiología , Masculino , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/fisiopatología , Persona de Mediana Edad , Femenino , Imagenología Tridimensional/métodos , Anciano , Adulto , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiología , Reproducibilidad de los Resultados
2.
Orthop J Sports Med ; 12(3): 23259671231219023, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38435717

RESUMEN

Background: One proposed mechanism of rotator cuff disease is scapular motion impairments contributing to rotator cuff compression and subsequent degeneration. Purpose: To model the effects of scapular angular deviations on rotator cuff tendon proximity for subacromial and internal mechanical impingement risk during scapular plane abduction. Study Design: Descriptive laboratory study. Methods: Three-dimensional bone models were reconstructed from computed tomography scans obtained from 10 asymptomatic subjects and 9 symptomatic subjects with a clinical presentation of impingement syndrome. Models were rotated to average scapular orientations from a healthy dataset at higher (120°) and lower (subject-specific) humeral elevation angles to investigate internal and subacromial impingement risks, respectively. Incremental deviations in scapular upward/downward rotation, internal/external rotation, and anterior/posterior tilt were imposed on the models to simulate scapular movement impairments. The minimum distance between the rotator cuff insertions and potential impinging structures (eg, glenoid, acromion) was calculated. Two-way mixed-model analyses of variance assessed for effects of scapular deviation and group. Results: At 120° of humerothoracic elevation, minimum distances from the supraspinatus and infraspinatus insertions to the glenoid increased with ≥5° changes in upward rotation (1.6-9.8 mm, P < .001) or external rotation (0.9-5.0 mm, P≤ .048), or with ≥10° changes in anterior tilt (1.1-3.2 mm, P < .001). At lower angles, ≥20° changes in most scapular orientations significantly increased the distance between the supraspinatus and infraspinatus insertions and the acromion or coracoacromial ligament. Conclusion: A reduction in scapular upward rotation decreases the distance between the rotator cuff tendon insertions and glenoid at 120° humerothoracic elevation. Interpretation is complicated for lower angles because the humeral elevation angle was defined by the minimum distance. Clinical Relevance: These results may assist clinical decision making regarding the effects of scapular movement deviations in patients with rotator cuff pathology and scapular dyskinesia and may help inform the selection of clinical interventions.

3.
J Orthop Res ; 42(3): 578-587, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37814893

RESUMEN

The purpose of this study was to develop a multivariable model to determine the extent to which a combination of etiological factors is associated with supraspinatus tendon tears. Fifty-four asymptomatic individuals (55 ± 4 years) underwent testing of their dominant shoulder. Diagnostic ultrasound was used to assess for a supraspinatus tendon tear. The etiological factors investigated included demographics (age and sex), tendon impingement during shoulder motion (via biplane videoradiography), glenohumeral morphology (via computed tomography imaging), family history of a tear (via self-report), occupational shoulder exposure (via shoulder job exposure matrix), and athletic exposure (via self-report). Univariate relationships between etiological predictors and supraspinatus tears were assessed using logistic regression and odds ratios (ORs), while multivariable relationships were assessed using classification and regression tree analysis. Thirteen participants (24.1%) had evidence of a supraspinatus tear. Individuals with a tear had a higher critical shoulder angle (OR 1.2, p = 0.028) and acromial index (OR 1.2, p = 0.016) than individuals without a tear. The multivariable model suggested that a tear in this cohort can be explained with acceptable accuracy (AUROC = 0.731) by the interaction between acromial index and shoulder occupational exposure: a tear is more likely in individuals with a high acromial index (p < 0.001), and in individuals with a low acromial index and high occupational exposure (p < 0.001). The combination of an individual's glenohumeral morphology (acromial index) and occupational shoulder exposure may be important in the development of supraspinatus tears.


Asunto(s)
Lesiones del Manguito de los Rotadores , Articulación del Hombro , Humanos , Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/etiología , Hombro , Rotura
4.
Braz J Phys Ther ; 27(3): 100505, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37167904

RESUMEN

BACKGROUND: Recent evidence suggests that internal impingement, or rotator cuff tendon deformation against the glenoid, occurs during overhead motions and may therefore be a mechanism of pathology even in non-athletes. Clinically, knowing how movement impacts potential injury mechanisms would be useful to guide movement-based treatment strategies. OBJECTIVE: To compare the distance between the glenoid and rotator cuff footprint between two groups classified based on scapulothoracic upward rotation (UR) magnitude (i.e., low, high) at 90° humerothoracic elevation. METHODS: Shoulder kinematics were quantified during scapular plane abduction in 60 participants using single-plane fluoroscopy. Of these, 40 were subsequently classified as having high or low scapulothoracic UR based on the sample's distribution. The minimum distance between the glenoid and rotator cuff footprint was calculated along with the locations of closest proximity (i.e., proximity centers). Minimum distances and proximity center locations were compared between groups using 2-factor mixed-model ANOVAs. The prevalence of glenoid-to-footprint contact was also compared. RESULTS: Glenoid-to-footprint distances consistently decreased as humerothoracic elevation angle increased, and the anterior aspect of the footprint was closest to the posterosuperior glenoid. Minimum distances were not significantly different between UR groups (p≥0.16). However, group differences existed in proximity center locations (p<0.01). Glenoid-to-footprint contact was identified in 75.0% of participants at an average (SD) of 133.6° (3.2°) humerothoracic elevation. CONCLUSION: The results of this study suggest that decreased UR as classified and assessed in this study does not significantly impact glenoid-to-footprint distances but does alter the location of the contact, which occurred in most participants.


Asunto(s)
Síndrome de Abducción Dolorosa del Hombro , Articulación del Hombro , Humanos , Manguito de los Rotadores , Rotación , Escápula , Fenómenos Biomecánicos
5.
J Orthop Res ; 41(4): 718-726, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35880416

RESUMEN

Internal impingement-or entrapment of the undersurface of the rotator cuff tendon against the glenoid during overhead activities-is believed to contribute to articular-sided tears. However, little is known about internal impingement outside athletic populations. Therefore, the objectives of this study were to (1) describe glenoid-to-footprint distances and proximity centers during dynamic, in vivo motion in asymptomatic individuals, and (2) determine the extent to which these measures differed between individuals with and without a rotator cuff tear. Shoulder kinematics were assessed in 37 asymptomatic individuals during scapular plane abduction using a high-speed biplane radiographic system. Glenoid-to-footprint distances and proximity center locations were calculated by combining the kinematics with computerized tomography-derived bone models. Glenoid-to-footprint contact was presumed to occur when the minimum distance was less than the estimated labral thickness. The condition of the supraspinatus tendon (intact, torn) was assessed using ultrasound. Minimum distances and proximity centers were compared over humerothoracic elevation angles (90°, 110°, 130°, 150°) and between supraspinatus pathology groups using two-factor mixed model analysis of variances. Glenoid-to-footprint minimum distances decreased consistently across elevation angles (p < 0.01) without a significant difference between groups. Contact was estimated to occur in all participants. Proximity centers were generally located on the anterior half of the rotator cuff footprint and on the posterosuperior glenoid. Statement of Clinical Significance: Internal impingement during overhead motions may be a prevalent mechanism of rotator cuff pathology as contact appears to be common and involves the region of the rotator cuff footprint where degenerative rotator cuff tears are thought to originate.


Asunto(s)
Lesiones del Manguito de los Rotadores , Síndrome de Abducción Dolorosa del Hombro , Articulación del Hombro , Humanos , Manguito de los Rotadores , Escápula , Rotación , Fenómenos Biomecánicos , Rango del Movimiento Articular
6.
Arch Phys Med Rehabil ; 104(3): 403-409, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36202228

RESUMEN

OBJECTIVE: To better understand how the shoulder moves in breast cancer survivors with axillary web syndrome (AWS), we compared 3-dimensional (3D) shoulder kinematics during shoulder elevation among breast cancer survivors with and without AWS 5 years postoperatively. Although research consistently shows decreased shoulder range of motion with AWS, we do not understand the underlying biomechanics. DESIGN: Nested case control study. SETTING: University Academic Breast Center. PARTICIPANTS: Twenty-five women who had surgery 5 years previously for unilateral breast cancer with the removal of at least 1 lymph node participated in this study (N=25). Twelve participants had AWS; 13 women did not have AWS. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Three-dimensional shoulder kinematic data during shoulder forward flexion, scapular plane abduction, and coronal plane abduction were collected using 3D electromagnetic motion tracking. Kinematic data were extracted at 30°, 60°, 90°, and 120° of arm elevation for scapular upward rotation, internal rotation, and posterior tilt as well as for glenohumeral external rotation. RESULTS: Women with AWS demonstrated 15.2° less scapular upward rotation at 120° humerothoracic elevation (95% confidence interval [-25.2, -5.2], P=.005), regardless of plane. No significant between-group differences were found for any other angle of scapular upward rotation, nor for scapular internal rotation, scapular posterior tilt, or glenohumeral axial rotation at any angle. CONCLUSIONS: Five years after surgery for breast cancer, women diagnosed with AWS have altered scapulohumeral kinematics that may place them at an increased risk of shoulder pain based on existing kinematic literature in healthy cohorts. This information can help guide rehabilitation programs for breast cancer survivors to facilitate pain-free upper extremity function after treatment.


Asunto(s)
Neoplasias de la Mama , Articulación del Hombro , Humanos , Femenino , Hombro , Fenómenos Biomecánicos , Estudios de Casos y Controles , Escápula , Rango del Movimiento Articular
7.
Skeletal Radiol ; 52(4): 695-703, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36195776

RESUMEN

OBJECTIVE: Determine the demographic and clinical factors that predict infraspinatus muscle degeneration in individuals with an isolated supraspinatus tendon tear. MATERIALS AND METHODS: A retrospective analysis was performed using the medical records of patients who had a shoulder MRI interpreted by 1 of 3 fellowship-trained musculoskeletal radiologists since the implementation of a standardized MRI 3 T protocol within our healthcare system. Demographic (e.g., age, sex) and clinical data (e.g., tear size, muscle degeneration, co-morbidities) were collected. Patients with an isolated supraspinatus tendon tear (n = 121) were assigned to one of two groups based on whether any infraspinatus muscle degeneration was present. Logistic regression was used to assess the univariate relationships between infraspinatus muscle degeneration and patient and clinical data, while least absolute shrinkage and selector operator (LASSO) logistic regression was used to assess the multivariable relationship. RESULTS: Of the patients with an isolated supraspinatus tendon tear, 16.5% had evidence of infraspinatus muscle degeneration. The presence of infraspinatus muscle degeneration was independently associated with cardiovascular disease (P = 0.01), supraspinatus muscle degeneration (P < 0.01), and subscapularis muscle degeneration (P = 0.01). When the multivariable relationship is assessed, supraspinatus muscle degeneration emerged as the only variable of significant importance for detecting infraspinatus muscle degeneration (specificity: 87.1%, sensitivity: 80.0%). CONCLUSION: Infraspinatus muscle degeneration is not uncommon in individuals with an isolated supraspinatus tear and is most associated with concomitant supraspinatus muscle degeneration. These findings highlight the need for clinicians to specifically assess the status of each rotator cuff muscle, even when the tendon itself is intact.


Asunto(s)
Laceraciones , Lesiones del Manguito de los Rotadores , Humanos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/patología , Estudios Retrospectivos , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/patología , Rotura , Tendones , Atrofia Muscular/patología , Imagen por Resonancia Magnética
8.
J Biomech ; 145: 111385, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36403529

RESUMEN

Several scapular anatomical coordinate systems have been reported in the literature to describe shoulder kinematics. Unfortunately, the use of different conventions hinders comparison across studies. Further, inconsistencies between a coordinate system and the scapula's 3D axis of motion means that scapular motion will be incorrectly attributed to axes about which it did not rotate. The objectives of this study were to: 1) determine the extent to which the axes of four common scapular coordinate system conventions correspond to the 3D axis of scapular motion (i.e., instantaneous helical axis, IHA), and 2) report the prevalence of scapulothoracic gimbal lock for each convention. Shoulder kinematics were tracked during scapular plane abduction in 45 participants using biplane videoradiography. Scapulothoracic kinematics were described using the original convention proposed by van der Helm, the convention recommended by the International Society of Biomechanics (ISB), a glenoid-based coordinate system, and a glenoid-oriented coordinate system. The 3D angle was calculated between the IHA and each axis of the four conventions (IHA-axis angular deviations). A repeated measures ANOVA was used to compare IHA-axis angular deviations between conventions. The glenoid-oriented and ISB conventions resulted in the smallest and largest IHA-axis angular deviations, respectively (21.7°±3.6° vs. 30.5°±5.2°, p < 0.01). Gimbal lock was approached in 17.8% of participants when using the original convention, 2.2% when using the ISB convention, and 0% when using the glenoid-based or -oriented conventions. These findings suggest the glenoid-oriented coordinate system may be worthy of further consideration when investigating shoulder kinematics during scapular plane abduction.

9.
J Biomech ; 136: 111059, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35367838

RESUMEN

Glenohumeral and scapulothoracic motion combine to generate humerothoracic motion, but their discrete contributions towards humerothoracic axial rotation have not been investigated. Understanding their contributions to axial rotation is important to judge the effects of pathology, surgical intervention, and physiotherapy. Therefore, the purpose of this study was to investigate the kinematic coupling between glenohumeral and scapulothoracic motion and determine their relative contributions towards axial rotation. Twenty healthy subjects (10 M/10F, ages 22-66) were previously recorded using biplane fluoroscopy while performing arm elevation in the coronal, scapular, and sagittal planes, and external rotation in 0° and 90° of abduction. Glenohumeral and scapulothoracic contributions towards axial rotation were computed by integrating the projection of glenohumeral and scapulothoracic angular velocity onto the humeral longitudinal axis, and analyzed using one dimensional statistical parametric mapping and linear regression. During arm elevation, scapulothoracic motion supplied 13-20° (76-94%) of axial rotation, mainly via scapulothoracic upward rotation. The contribution of scapulothoracic motion towards axial rotation was strongly correlated with glenohumeral plane of elevation during arm elevation. During external rotation, scapulothoracic motion contributed 10° (8%) towards axial rotation in 0° of abduction and 15° (15%) in 90° of abduction. The contribution of scapulothoracic motion towards humerothoracic axial rotation could explain the simultaneous changes in glenohumeral plane of elevation and axial rotation associated with some pathologies and surgeries. Understanding how humerothoracic motion results from the functional coupling of scapulothoracic and glenohumeral motions may inform diagnostic and treatment strategies by targeting the source of movement impairments in clinical populations.


Asunto(s)
Articulación del Hombro , Adulto , Anciano , Fenómenos Biomecánicos , Humanos , Húmero , Persona de Mediana Edad , Rango del Movimiento Articular , Rotación , Escápula , Adulto Joven
10.
Orthop J Sports Med ; 10(3): 23259671221084294, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35387360

RESUMEN

Background: Rotator cuff repair is a common orthopaedic procedure that provides pain relief for many patients, but unfortunately, an estimated 20% to 70% of repair procedures will fail. Previous research has shown that elongation (ie, retraction) of a repaired tendon is common even in patients with a repair construct that appears intact on magnetic resonance imaging. However, it is unknown how this repair tissue functions under dynamic conditions. Purpose: To quantify static retraction and maximum dynamic elongation of repair tissue after rotator cuff repair. Study Design: Case series; Level of evidence, 4. Methods: Data from 9 patients were analyzed for this study. During surgery, a 3.1-mm tantalum bead was sutured to the supraspinatus tendon, medial to the repair site. Glenohumeral kinematics were assessed at 1 week (static) and 3 months (static and during scapular-plane abduction) after surgery using a biplanar videoradiographic system. The 3-dimensional position of the bead was calculated relative to the tendon's insertion on the humerus (ie, bead-to-insertion distance). Static retraction was calculated as the change in the bead-to-insertion distance under static conditions between 1 week and 3 months after surgery, and maximum dynamic elongation was calculated as the maximal positive change in the bead-to-insertion distance during dynamic motion relative to the start of motion. The magnitudes of static retraction and maximum dynamic elongation were assessed with 1-sample t tests. Results: At 3 months after surgery, static retraction occurred in all patients by a mean of 10.0 ± 9.1 mm (P = .01 compared with no elongation). During scapular-plane abduction, maximum dynamic elongation averaged 1.4 ± 1.0 mm (P < .01 compared with no elongation). Descriptively, dynamic elongation consistently took 1 of 2 forms: an initial increase in the bead-to-insertion distance (mean, 2.0 ± 0.6 mm) before decreasing until the end of motion or an immediate and substantial decrease in the bead-to-insertion distance at the onset of motion. Conclusion: Repair tissue elongation (static retraction and maximum dynamic elongation) appeared to be a common and significant finding at 3 months after arthroscopic rotator cuff repair. Dynamic elongation of repair tissue during scapular-plane abduction exhibited 1 of 2 distinct patterns, which may suggest different patterns of supraspinatus mechanical and neuromuscular function.

11.
JSES Int ; 6(1): 62-69, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35141678

RESUMEN

BACKGROUND: Rotator cuff repair provides pain relief for many patients; however, retears are relatively common and affect approximately 20%-70% of patients after repair. Although magnetic resonance imaging (MRI) offers the ability to assess tissue characteristics such as tear size, retraction, and fatty infiltration, it provides little insight into the quality of the musculotendinous tissues the surgeon will encounter during surgery. However, shear wave elastography (SWE) could provide an indirect assessment of quality (ie, stiffness) by measuring the speed of shear waves propagating through tissue. The objective of this study was to determine the extent to which estimated shear modulus predicts repair integrity and functional outcomes 1 year after rotator cuff repair. METHODS: Thirty-three individuals scheduled to undergo arthroscopic rotator cuff repair were enrolled in this study. Before surgery, shear modulus of the supraspinatus tendon and muscle was estimated using ultrasound SWE. MRIs were obtained before and 1 year after surgery to assess tear characteristics and repair integrity, respectively. Shoulder strength, range of motion, and patient-reported pain and function were assessed before and after surgery. Functional outcomes were compared between groups and across time using a two-factor mixed model analysis of variance. Stepwise regression with model comparison was used to investigate the extent to which MRI and shear modulus predicted repair integrity and function at 1 year after surgery. RESULTS: At 1 year after surgery, 56.5% of patients had an intact repair. No significant differences were found in any demographic variable, presurgical tear characteristic, or shear modulus between patients with an intact repair and those with a recurrent tear. Compared with presurgical measures, patients in both groups demonstrated significant improvements at 1 year after surgery in pain (P < .01), self-reported function (P < .01), range of motion (P < .01), and shoulder strength (P < .01). In addition, neither presurgical MRI variables (P > .16) nor shear modulus (P > .52) was significantly different between groups at 1 year after surgery. Finally, presurgical shear modulus generally did not improve the prediction of functional outcomes above and beyond that provided by MRI variables alone (P > .22). CONCLUSION: Although SWE remains a promising modality for many clinical applications, this study found that SWE-estimated shear modulus did not predict repair integrity or functional outcomes at 1 year after surgery, nor did it add to the prediction of outcomes above and beyond that provided by traditional presurgical MRI measures of tear characteristics. Therefore, it appears that further research is needed to fully understand the clinical utility of SWE for musculoskeletal tissue and its potential use for predicting outcomes after surgical rotator cuff repair.

12.
Orthop J Sports Med ; 9(10): 23259671211036908, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34646898

RESUMEN

BACKGROUND: Rotator cuff tears may result from repeated mechanical deformation of the cuff tendons, and internal impingement of the supraspinatus tendon against the glenoid is one such proposed mechanism of deformation. PURPOSE: To (1) describe the changing proximity of the supraspinatus tendon to the glenoid during a simulated overhead reaching task and (2) determine the relationship between scapular morphology and this proximity. Additionally, the patterns of supraspinatus-to-glenoid proximity were compared with previously described patterns of supraspinatus-to-coracoacromial arch proximity. STUDY DESIGN: Descriptive laboratory study. METHODS: Shoulder models were created from magnetic resonance images of 20 participants. Standardized kinematics were imposed on the models to simulate functional reaching, and the minimum distances between the supraspinatus tendon and the glenoid and the supraspinatus footprint and the glenoid were calculated every 5° between 0° and 150° of humerothoracic elevation. The angle at which contact between the supraspinatus and the glenoid occurred was documented. Additionally, the relationship between glenoid morphology (version and inclination) and the contact angle was evaluated. Descriptive statistics were calculated for the minimum distances, and glenoid morphology was assessed using Pearson correlation coefficients and simple linear regressions. RESULTS: The minimum distances between the tendon and the glenoid and between the footprint and the glenoid decreased as elevation increased. Contact between the tendon and the glenoid occurred in all participant models at a mean elevation of 123° ± 10°. Contact between the footprint and the glenoid occurred in 13 of 20 models at a mean of 139° ± 10°. Less glenoid retroversion was associated with lower tendon-to-glenoid contact angles (r = -0.76; R 2 = 0.58; P < .01). CONCLUSION: This study found that the supraspinatus tendon progressively approximated the glenoid during simulated overhead reaching. Additionally, all participant models eventually made contact with the glenoid by 150° of humerothoracic elevation, although anatomic factors influenced the precise angle at which contact occurred. CLINICAL RELEVANCE: Contact between the supraspinatus and the glenoid may occur frequently within the range of elevation required for overhead activities. Therefore, internal impingement may be a prevalent mechanism for rotator cuff deformation that could contribute to cuff pathology.

14.
JSES Int ; 5(3): 500-506, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34136861

RESUMEN

BACKGROUND: Approximately 20-60% of rotator cuff repairs fail with higher failure rates in patients with larger or more chronic tears. Although MRI provides an objective estimate of tear size, it can only provide qualitative descriptions of tear chronicity. By contrast, ultrasound shear wave elastography (SWE) may assess tear chronicity by estimating tissue mechanical properties (ie, shear modulus). Furthermore, SWE imaging does not share many of the challenges associated with MRI (eg, high cost, risk of claustrophobia). Therefore, the objective of this study was to determine the extent to which estimated supraspinatus shear modulus is associated with conventional MRI-based measures of rotator cuff tear size and chronicity. METHODS: Shear modulus was estimated using ultrasound SWE in two regions of the supraspinatus (intramuscular tendon, muscle belly) under two contractile conditions (passive, active) in 22 participants with full-thickness rotator cuff tears. The extent to which estimated supraspinatus shear modulus is associated with conventional MRI measures of tear size and chronicity was assessed using correlation coefficients and Kruskal-Wallis tests, as appropriate. RESULTS: Estimated shear modulus was not significantly associated with anterior/posterior tear size (P > .09), tear retraction (P > .20), occupation ratio (P > .11), or fatty infiltration (P > .30) under any testing condition. DISCUSSION: Although ultrasound SWE measurements have been shown to be altered in the presence of various tendinopathies, the findings of this study suggest the utility of ultrasound SWE in this population (ie, patients with a small to medium supraspinatus rotator cuff tear) before surgical rotator cuff repair remains unclear.

15.
J Vis Exp ; (169)2021 03 12.
Artículo en Inglés | MEDLINE | ID: mdl-33779606

RESUMEN

The shoulder is one of the human body's most complex joint systems, with motion occurring through the coordinated actions of four individual joints, multiple ligaments, and approximately 20 muscles. Unfortunately, shoulder pathologies (e.g., rotator cuff tears, joint dislocations, arthritis) are common, resulting in substantial pain, disability, and decreased quality of life. The specific etiology for many of these pathologic conditions is not fully understood, but it is generally accepted that shoulder pathology is often associated with altered joint motion. Unfortunately, measuring shoulder motion with the necessary level of accuracy to investigate motion-based hypotheses is not trivial. However, radiographic-based motion measurement techniques have provided the advancement necessary to investigate motion-based hypotheses and provide a mechanistic understanding of shoulder function. Thus, the purpose of this article is to describe the approaches for measuring shoulder motion using a custom biplanar videoradiography system. The specific objectives of this article are to describe the protocols to acquire biplanar videoradiographic images of the shoulder complex, acquire CT scans, develop 3D bone models, locate anatomical landmarks, track the position and orientation of the humerus, scapula, and torso from the biplanar radiographic images, and calculate the kinematic outcome measures. In addition, the article will describe special considerations unique to the shoulder when measuring joint kinematics using this approach.


Asunto(s)
Movimiento , Manguito de los Rotadores/fisiología , Articulación del Hombro/fisiología , Hombro/fisiología , Tomografía Computarizada por Rayos X/métodos , Grabación de Cinta de Video , Fenómenos Biomecánicos , Femenino , Humanos , Persona de Mediana Edad , Hombro/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen
16.
J Biomech ; 109: 109924, 2020 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-32807327

RESUMEN

The rotator cuff is theorized to contribute to force couples required to produce glenohumeral kinematics. Impairment in these force couples would theoretically result in impaired ball-and-socket kinematics. Although less frequently used than traditional kinematic descriptors (e.g., Euler angles, joint translations), helical axes are capable of identifying alterations in ball-and-socket kinematics by quantifying the variability (i.e., dispersion) in axis orientation and position during motion. Consequently, assessing glenohumeral helical dispersion may provide indirect evidence of rotator cuff function. The purpose of this exploratory study was to determine the extent to which rotator cuff pathology is associated with alterations in ball-and-socket kinematics. Fifty-one participants were classified into one of five groups based on an assessment of the supraspinatus using diagnostic imaging: asymptomatic healthy, asymptomatic tendinosis, asymptomatic partial-thickness tear, asymptomatic full-thickness tear, symptomatic full-thickness tear. Glenohumeral kinematics were quantified during coronal plane abduction using a biplane x-ray system and described using instantaneous helical axes. The degree to which glenohumeral motion coincided with ball-and-socket kinematics was described using the angular and positional dispersion about the optimal helical axis and pivot, respectively. No statistically significant difference was observed between groups in angular dispersion. However, symptomatic individuals with a full-thickness supraspinatus tear had significantly more positional dispersion than asymptomatic individuals with a healthy supraspinatus or tendinosis. These findings suggest that symptomatic individuals with a full-thickness supraspinatus tear exhibit impaired ball-and-socket kinematics, which is believed to be associated with a disruption of the glenohumeral force couples.


Asunto(s)
Lesiones del Manguito de los Rotadores , Articulación del Hombro , Fenómenos Biomecánicos , Humanos , Rango del Movimiento Articular , Manguito de los Rotadores
17.
PLoS One ; 15(2): e0228594, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32059007

RESUMEN

Biplane radiography and associated shape-matching provides non-invasive, dynamic, 3D osteo- and arthrokinematic analysis. Due to the complexity of data acquisition, each system should be validated for the anatomy of interest. The purpose of this study was to assess our system's acquisition methods and validate a custom, automated 2D/3D shape-matching algorithm relative to radiostereometric analysis (RSA) for the cervical and lumbar spine. Additionally, two sources of RSA error were examined via a Monte Carlo simulation: 1) static bead centroid identification and 2) dynamic bead tracking error. Tantalum beads were implanted into a cadaver for RSA and cervical and lumbar spine flexion and lateral bending were passively simulated. A bead centroid identification reliability analysis was performed and a vertebral validation block was used to determine bead tracking accuracy. Our system's overall root mean square error (RMSE) for the cervical spine ranged between 0.21-0.49mm and 0.42-1.80° and the lumbar spine ranged between 0.35-1.17mm and 0.49-1.06°. The RMSE associated with RSA ranged between 0.14-0.69mm and 0.96-2.33° for bead centroid identification and 0.25-1.19mm and 1.69-4.06° for dynamic bead tracking. The results of this study demonstrate our system's ability to accurately quantify segmental spine motion. Additionally, RSA errors should be considered when interpreting biplane validation results.


Asunto(s)
Algoritmos , Radiografía/métodos , Columna Vertebral/diagnóstico por imagen , Fenómenos Biomecánicos , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Radiografía/instrumentación , Radiografía/normas , Reproducibilidad de los Resultados
18.
Braz J Phys Ther ; 24(3): 219-230, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31377124

RESUMEN

BACKGROUND: Alterations in glenohumeral and scapulothoracic kinematics have been theorized to contribute to rotator cuff pathology by impacting the magnitude of the subacromial space. OBJECTIVE: The purpose of this review is to summarize what is currently known about the relationship between shoulder kinematics and subacromial proximities. CONCLUSIONS: A variety of methods have been used to quantify subacromial proximities including photographs, MR imaging, ultrasonography, and single- and bi-plane radiographs. Changes in glenohumeral and scapulothoracic kinematics are associated with changes in subacromial proximities. However, the magnitude and direction of a particular motion's impact on subacromial proximities often vary between studies, which likely reflects different methodologies and subject populations. Glenohumeral elevation angle has been consistently found to impact subacromial proximities. Plane of humeral elevation also impacts subacromial proximities but to a lesser degree than the elevation angle. The impact of decreased scapulothoracic upward rotation on subacromial proximities is not absolute, but instead depends on the angle of humerothoracic elevation. The effects of scapular dyskinesis and humeral and scapular axial rotations on subacromial proximities are less clear. Future research is needed to further investigate the relationship between kinematics and subacromial proximities using more homogenous groups, determine the extent to which compression and other factors contribute to rotator cuff pathology, and develop accurate and reliable clinical measures of shoulder motion.


Asunto(s)
Discinesias/fisiopatología , Manguito de los Rotadores/fisiopatología , Hombro/fisiología , Ultrasonografía/métodos , Humanos , Escápula/fisiología
19.
Phys Ther ; 100(2): 283-294, 2020 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-31696926

RESUMEN

BACKGROUND: Scapulothoracic upward rotation (UR) is an important shoulder complex motion allowing for a larger functional work space and improved glenohumeral muscle function. However, the kinematic mechanisms producing scapulothoracic UR remain unclear, limiting the understanding of normal and abnormal shoulder movements. OBJECTIVE: The objective of this study was to identify the coupling relationships through which sternoclavicular and acromioclavicular joint motions contribute to scapulothoracic UR. DESIGN: This was a cross-sectional observational study. METHODS: Sixty participants were enrolled in this study; 30 had current shoulder pain, and 30 had no history of shoulder symptoms. Shoulder complex kinematics were quantified using single-plane fluoroscopy and 2D/3D shape matching and were described as finite helical displacements for 30-degree phases of humerothoracic elevation (30 degrees-60 degrees, 60 degrees-90 degrees, and 90 degrees-120 degrees). A coupling function was derived to estimate scapulothoracic UR from its component motions of acromioclavicular UR, sternoclavicular posterior rotation, and sternoclavicular elevation as a function of acromioclavicular internal rotation. The proportional contributions of each of the component motions were also calculated and compared between phases of humerothoracic elevation and groups. RESULTS: Scapulothoracic UR displacement could be effectively predicted using the derived coupling function. During the 30- to 60-degree humerothoracic elevation phase, acromioclavicular UR accounted for 84.2% of scapulothoracic UR, whereas sternoclavicular posterior rotation and elevation each accounted for < 10%. During later phases, acromioclavicular UR and sternoclavicular posterior rotation each accounted for 32% to 42%, whereas sternoclavicular elevation accounted for < 11%. LIMITATIONS: Error due to the tracking of sternoclavicular posterior rotation may have resulted in an underprediction of its proportional contribution and an overprediction of the proportional contribution of acromioclavicular UR. CONCLUSIONS: Acromioclavicular UR and sternoclavicular posterior rotation are the predominant component motions of scapulothoracic UR. More research is needed to investigate how these coupling relationships are affected by muscle function and influenced by scapular dyskinesis.


Asunto(s)
Articulación Acromioclavicular/fisiología , Rango del Movimiento Articular/fisiología , Dolor de Hombro/fisiopatología , Hombro/fisiología , Articulación Esternoclavicular/fisiología , Adulto , Fenómenos Biomecánicos/fisiología , Análisis de Datos , Femenino , Humanos , Masculino , Movimiento/fisiología , Rotación , Escápula/fisiología , Síndrome de Abducción Dolorosa del Hombro/fisiopatología , Tórax/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...