Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38236087

RESUMEN

We present the development of an experimental platform that can collect four frames of x-ray diffraction data along a single line of sight during laser-driven, dynamic-compression experiments at the National Ignition Facility. The platform is comprised of a diagnostic imager built around ultrafast sensors with a 2-ns integration time, a custom target assembly that serves also to shield the imager, and a 10-ns duration, quasi-monochromatic x-ray source produced by laser-generated plasma. We demonstrate the performance with diffraction data for Pb ramp compressed to 150 GPa and illuminated by a Ge x-ray source that produces ∼7 × 1011, 10.25-keV photons/ns at the 400 µm diameter sample.

2.
Rev Sci Instrum ; 91(4): 043902, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32357733

RESUMEN

We report details of an experimental platform implemented at the National Ignition Facility to obtain in situ powder diffraction data from solids dynamically compressed to extreme pressures. Thin samples are sandwiched between tamper layers and ramp compressed using a gradual increase in the drive-laser irradiance. Pressure history in the sample is determined using high-precision velocimetry measurements. Up to two independently timed pulses of x rays are produced at or near the time of peak pressure by laser illumination of thin metal foils. The quasi-monochromatic x-ray pulses have a mean wavelength selectable between 0.6 Å and 1.9 Å depending on the foil material. The diffracted signal is recorded on image plates with a typical 2θ x-ray scattering angle uncertainty of about 0.2° and resolution of about 1°. Analytic expressions are reported for systematic corrections to 2θ due to finite pinhole size and sample offset. A new variant of a nonlinear background subtraction algorithm is described, which has been used to observe diffraction lines at signal-to-background ratios as low as a few percent. Variations in system response over the detector area are compensated in order to obtain accurate line intensities; this system response calculation includes a new analytic approximation for image-plate sensitivity as a function of photon energy and incident angle. This experimental platform has been used up to 2 TPa (20 Mbar) to determine the crystal structure, measure the density, and evaluate the strain-induced texturing of a variety of compressed samples spanning periods 2-7 on the periodic table.

3.
Phys Rev E ; 101(2-1): 023204, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32168658

RESUMEN

We report measurements of K-shell fluorescence lines induced by fast electrons in ramp-compressed Co targets. The fluorescence emission was stimulated by fast electrons generated through short-pulse laser-solid interaction with an Al target layer. Compression up to 2.1× solid density was achieved while maintaining temperatures well below the Fermi energy, effectively removing the thermal effects from consideration. We observed small but unambiguous redshifts in the Kß fluorescence line relative to unshifted Cu Kα. Redshifts up to 2.6 eV were found to increase with compression and to be consistent with predictions from self-consistent models based on density-functional theory.

4.
Phys Rev Lett ; 115(9): 095701, 2015 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-26371663

RESUMEN

The melting of bismuth in response to shock compression has been studied using in situ femtosecond x-ray diffraction at an x-ray free electron laser. Both solid-solid and solid-liquid phase transitions are documented using changes in discrete diffraction peaks and the emergence of broad, liquid scattering upon release from shock pressures up to 14 GPa. The transformation from the solid state to the liquid is found to occur in less than 3 ns, very much faster than previously believed. These results are the first quantitative measurements of a liquid material obtained on shock release using x-ray diffraction, and provide an upper limit for the time scale of melting of bismuth under shock loading.

5.
Nature ; 511(7509): 330-3, 2014 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-25030170

RESUMEN

The recent discovery of more than a thousand planets outside our Solar System, together with the significant push to achieve inertially confined fusion in the laboratory, has prompted a renewed interest in how dense matter behaves at millions to billions of atmospheres of pressure. The theoretical description of such electron-degenerate matter has matured since the early quantum statistical model of Thomas and Fermi, and now suggests that new complexities can emerge at pressures where core electrons (not only valence electrons) influence the structure and bonding of matter. Recent developments in shock-free dynamic (ramp) compression now allow laboratory access to this dense matter regime. Here we describe ramp-compression measurements for diamond, achieving 3.7-fold compression at a peak pressure of 5 terapascals (equivalent to 50 million atmospheres). These equation-of-state data can now be compared to first-principles density functional calculations and theories long used to describe matter present in the interiors of giant planets, in stars, and in inertial-confinement fusion experiments. Our data also provide new constraints on mass-radius relationships for carbon-rich planets.

6.
Rev Sci Instrum ; 83(11): 113904, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23206073

RESUMEN

A method of obtaining powder diffraction data on dynamically compressed solids has been implemented at the Jupiter and OMEGA laser facilities. Thin powdered samples are sandwiched between diamond plates and ramp compressed in the solid phase using a gradual increase in the drive-laser intensity. The pressure history in the sample is determined by back-propagation of the measured diamond free-surface velocity. A pulse of x rays is produced at the time of peak pressure by laser illumination of a thin Cu or Fe foil and collimated at the sample plane by a pinhole cut in a Ta substrate. The diffracted signal is recorded on x-ray sensitive material, with a typical d-spacing uncertainty of ~0.01 Å. This diagnostic has been used up to 0.9 TPa (9 Mbar) to verify the solidity, measure the density, constrain the crystal structure, and evaluate the strain-induced texturing of a variety of compressed samples spanning atomic numbers from 6 (carbon) to 82 (lead). Further refinement of the technique will soon enable diffraction measurements in solid samples at pressures exceeding 1 TPa.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...