Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Photoacoustics ; 20: 100207, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33024694

RESUMEN

Photoacoustic imaging (PAI) takes advantage of both optical and ultrasound imaging properties to visualize optical absorption with high resolution and contrast. Photoacoustic microscopy (PAM) is usually categorized with all-optical microscopy techniques such as optical coherence tomography or confocal microscopes. Despite offering high sensitivity, novel imaging contrast, and high resolution, PAM is not generally an all-optical imaging method unlike the other microscopy techniques. One of the significant limitations of photoacoustic microscopes arises from their need to be in physical contact with the sample through a coupling media. This physical contact, coupling, or immersion of the sample is undesirable or impractical for many clinical and pre-clinical applications. This also limits the flexibility of photoacoustic techniques to be integrated with other all-optical imaging microscopes for providing complementary imaging contrast. To overcome these limitations, several non-contact photoacoustic signal detection approaches have been proposed. This paper presents a brief overview of current non-contact photoacoustic detection techniques with an emphasis on all-optical detection methods and their associated physical mechanisms.

2.
Biomed Opt Express ; 10(11): 5461-5469, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31799024

RESUMEN

Identifying positive surgical margins after resection of cancer often triggers re-excision and adjuvant treatments. Incomplete initial resections result in poorer patient outcomes, psychological and financial stress to the patient and increased healthcare costs. Surgical margins are typically assessed post-operatively using time consuming and expensive slide-based histopathology tissue analysis. Currently, a real-time non-contact virtual histology-like intraoperative margin assessment tool is not available. To address this need, we have developed a non-contact multi-wavelength reflection-mode, photoacoustic remote sensing (PARS) microscope demonstrating chromophore selective contrast in human tissues. We show the capabilities of multi-wavelength PARS microscopy utilizing both 266 nm and 532 nm excitation wavelengths and a 1310 nm detection wavelength. Cell nuclei and hemoglobin were visualized at the cellular scale without the addition of exogenous contrast agents. These works provide a critical step towards a virtual histology tool to provide intraoperative histology-like information in living tissue.

3.
Sci Rep ; 9(1): 13392, 2019 09 16.
Artículo en Inglés | MEDLINE | ID: mdl-31527734

RESUMEN

Surgical oncologists depend heavily on visual field acuity during cancer resection surgeries for in-situ margin assessment. Clinicians must wait up to two weeks for results from a pathology lab to confirm a post-operative diagnosis, potentially resulting in subsequent treatments. Currently, there are no clinical tools that can visualize diagnostically pertinent tissue information in-situ. Here, we present the first microscopy capable of non-contact label-free visualization of human cellular morphology in a reflection-mode apparatus. This is possible with the recently reported imaging modality called photoacoustic remote sensing microscopy which enables non-contact detection of optical absorption contrast. By taking advantage of the 266-nanometer optical absorption peak of DNA, photoacoustic remote sensing is efficacious in recovering qualitatively similar nuclear information in comparison to that provided by the hematoxylin stain in the gold-standard hematoxylin and eosin (H&E) prepared samples. A photoacoustic remote sensing system was employed utilizing a 266-nanometer pulsed excitation beam to induce photoacoustic pressures within the sample resulting in refractive index modulation of the optical absorber. A 1310-nanometer continuous-wave interrogation beam detects these perturbed regions as back reflected intensity variations due to the changes in the local optical properties. Using this technique, clinically useful histologic images of human tissue samples including breast cancer (invasive ductal carcinoma), tonsil, gastrointestinal, and pancreatic tissue images were formed. These were qualitatively comparable to standard H&E prepared samples.


Asunto(s)
Neoplasias de la Mama/patología , Eosina Amarillenta-(YS)/química , Neoplasias Gastrointestinales/patología , Hematoxilina/química , Microscopía/métodos , Neoplasias Pancreáticas/patología , Neoplasias Tonsilares/patología , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Neoplasias Gastrointestinales/diagnóstico por imagen , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Tonsilares/diagnóstico por imagen
4.
Sensors (Basel) ; 19(16)2019 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-31434241

RESUMEN

Photoacoustic imaging (PAI) is an emerging imaging technique that bridges the gap between pure optical and acoustic techniques to provide images with optical contrast at the acoustic penetration depth. The two key components that have allowed PAI to attain high-resolution images at deeper penetration depths are the photoacoustic signal generator, which is typically implemented as a pulsed laser and the detector to receive the generated acoustic signals. Many types of acoustic sensors have been explored as a detector for the PAI including Fabry-Perot interferometers (FPIs), micro ring resonators (MRRs), piezoelectric transducers, and capacitive micromachined ultrasound transducers (CMUTs). The fabrication technique of CMUTs has given it an edge over the other detectors. First, CMUTs can be easily fabricated into given shapes and sizes to fit the design specifications. Moreover, they can be made into an array to increase the imaging speed and reduce motion artifacts. With a fabrication technique that is similar to complementary metal-oxide-semiconductor (CMOS), CMUTs can be integrated with electronics to reduce the parasitic capacitance and improve the signal to noise ratio. The numerous benefits of CMUTs have enticed researchers to develop it for various PAI purposes such as photoacoustic computed tomography (PACT) and photoacoustic endoscopy applications. For PACT applications, the main areas of research are in designing two-dimensional array, transparent, and multi-frequency CMUTs. Moving from the table top approach to endoscopes, some of the different configurations that are being investigated are phased and ring arrays. In this paper, an overview of the development of CMUTs for PAI is presented.

5.
BMC Infect Dis ; 19(1): 360, 2019 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-31035953

RESUMEN

BACKGROUND: Syphilis is a sexually transmitted infection caused by the bacterium Treponema pallidum. The disease affects all ages and both sexes but more prevalent among the sexually active age group of 15-49 years. The purpose of the current study was to determine the prevalence and factors associated with syphilis infection among outpatients 15-49 years in the Asikuma Odoben Brakwa District of Ghana where high levels of infection were earlier reported among antenatal women. METHODS: A descriptive cross-sectional study was carried out in 13 randomly selected health facilities. Blood samples were collected and tested for syphilis infection and a questionnaire administered to determine factors associated with the disease. RESULTS: A total 277 patients aged 15-49 years participated in the study. The overall prevalence of syphilis infection was 3.2% (9/277), with 5.7% (6/105) and 1.7% (3/172) among males and females respectively. Significant factors associated with syphilis infection included sub-district of residence, (χ2 (4) = 31.20, p < 0.001) and history of coerced sexual intercourse (χ2 (1) =7.49, p = 0.006). CONCLUSIONS: The prevalence of syphilis infection was high among male patients who lived in rural areas. Having a history of coerced sexual intercourse was a strong predictor for syphilis infection. Access to sexually transmitted infection control interventions in rural communities including health education may help control the disease.


Asunto(s)
Enfermedades de Transmisión Sexual/diagnóstico , Sífilis/diagnóstico , Adolescente , Adulto , Estudios Transversales , Femenino , Ghana/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Pacientes Ambulatorios , Prevalencia , Conducta Sexual , Enfermedades de Transmisión Sexual/epidemiología , Enfermedades de Transmisión Sexual/microbiología , Sífilis/epidemiología , Sífilis/microbiología , Treponema pallidum/aislamiento & purificación , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA