Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Aorta (Stamford) ; 9(2): 76-82, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34666377

RESUMEN

BACKGROUND: Understanding near-death experiences (NDE) could provide a new insight into the analysis of human consciousness and the neurocognitive processes happening upon the approach of death. With a temporary interruption of systemic perfusion, aortic surgery under hypothermic circulatory arrest (HCA) may be the only available model of reversible clinical death. We present, herein, the results of an observational study designed to assess the incidence of NDE after aortic surgery. METHODS: We performed a prospective study including consecutive patients who underwent thoracic aortic surgery between July 2018 and September 2019 at our institution. Procedures without HCA were included to constitute a control group. The primary outcome was the incidence of NDE assessed with the Greyson NDE scale during the immediate postoperative course, via a standardized interview of the patients in the surgical ward. RESULTS: One hundred and one patients were included. Twenty-one patients (20.8%) underwent nonelective interventions for aortic dissection. Ninety-one patients had hemiarch replacement (90.1%). Sixty-seven (66.3%) interventions were performed with HCA, with an average circulatory arrest duration of 26.9 ± 25.5 minutes, and a mean body temperature of 23.7 ± 3.8°C. None of the patients reported any recollection from their period of unconsciousness. There was no NDE experiencer in the study cohort. CONCLUSION: Several confounding factors regarding anesthesia, or NDE evaluation, might have impaired the chance of NDE recollections, and might have contributed to this negative result. Whether HCA may trigger NDE remains unknown.

3.
J Cardiovasc Surg (Torino) ; 61(6): 776-783, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32558524

RESUMEN

BACKGROUND: The Shelhigh™ SuperStentless (Shelhigh, INC., Union, NJ, USA) is a stentless aortic valve bioprosthesis and aortic root valved conduit. In 2007, this device was recalled by FDA due to malfunction, and subsequently reintegrated by BioIntegral Surgical™ Few data are available over late durability of this device. We performed a long-term follow-up of Shelhigh™ devices implanted at our center. METHODS: Between 2002 and 2007, 44 patients underwent aortic valve replacement with a Shelhigh™ device (40 aortic valve bioprosthesis and 4 valved conduit). We performed a clinical and echocardiographic follow-up (9.2 years±4.3). Standardized definitions of valve-related events were adopted. RESULTS: At discharge, maximum and mean aortic gradients averaged 36.1±11.3 and 21.0±6.8 mmHg, respectively. The 30-days mortality was 2.3%. Over the follow-up period, 29 patients died (65.9%); 2 deaths were valve related. Overall survival at 1, 5 and 10 years was 97.7%, 85.8% and 54% respectively. At last echocardiography, average transvalvular gradients had remained globally stable in the population (33.6±12 and 20.4±10.5 mmHg). Eight (19%) structural valve deterioration (SVD) events were reported. Two (5%) non-structural valve dysfunction (NSVD) events occurred (periprosthetic leak). Two (5%) infectious endocarditis events and two (5%) valve thromboses were also deplored. Three (7%) patients required re-operation (2 due to SVD and 1 due to endocarditis). CONCLUSIONS: The immediate hemodynamic performance of the Shelhigh™ aortic bioprostheses was unexpectedly suboptimal. Despite this, hemodynamic performance remained stable over time. Patients survival at follow-up was satisfactory, however, continued surveillance is necessary.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Bases de Datos Factuales , Femenino , Francia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
4.
Chin J Traumatol ; 23(3): 185-186, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32532660

RESUMEN

Thoracic splenosis is the autotransplantation of splenic tissue in the left thoracic cavity as a result of a splenic injury. This rare pathology is usually asymptomatic and may be discovered on incidental imaging, but the diagnosis often requires invasive procedures such as surgery in order to eliminate a neoplasic origin. We report a rare symptomatic case of a 39-year-old man presenting with chest pain and multiple nodules revealed on a computed tomography scan. The patient underwent a surgical exploration and the pathological studies concluded to a thoracic splenosis. Indeed, the previous medical history of the patient revealed a left thoraco-abdominal traumatism during childhood. The aim of this paper is to emphasize that the diagnosis can now be performed using only imaging techniques such as technetium-99 sulfur colloid or labelled heat-denatured red blood cell scintigraphy to avoid unnecessary invasive procedures including thoracotomy.


Asunto(s)
Traumatismos Abdominales/complicaciones , Enfermedades Asintomáticas , Bazo/lesiones , Esplenosis/diagnóstico , Esplenosis/etiología , Enfermedades Torácicas/diagnóstico , Enfermedades Torácicas/etiología , Traumatismos Torácicos/complicaciones , Procedimientos Innecesarios , Adulto , Humanos , Masculino , Esplenectomía , Esplenosis/patología , Esplenosis/cirugía , Enfermedades Torácicas/patología , Enfermedades Torácicas/cirugía , Toracotomía
5.
J Vasc Surg Cases Innov Tech ; 4(4): 296-300, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30547150

RESUMEN

Aortic infection is a challenging condition. Fortunately, surgical revision of infected aorta with in situ reconstruction can provide long-term cure. The material for aortic repair remains an area of debate. The Omniflow II (LeMaitre Vascular, Burlington, Mass) prosthesis is a biosynthetic graft made to resist long-term degeneration and allows growth of host tissue with reduction of the risk of arterial infection. It has already been used for peripheral bypass with very low infection rates. Herein, we describe an original case of first-line native aorta replacement by a straight Omniflow II biologic prosthesis for infected aortic aneurysm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA