Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Food Chem ; 203: 104-116, 2016 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-26948595

RESUMEN

Lipid oxidation during olive oil storage induces changes in the metabolite content of the oil, which can be measured using so-called quality indices. High values indicate poor quality oils that should be labeled accordingly or removed from the market. Based on quality indices measured over two years for two olive oils, the AComDim method was used to highlight the influence of five factors (olive oil type, oxygen, light, temperature and storage time) on oxidative stability during storage. To identify the significant factors, two full factorial experimental designs were built, each containing four of the five factors examined. The results showed that all five factors, as well as some two-factor interactions, were significant. Phenols and hydroperoxides were identified as being the most sensitive to these factors, and potential markers for the ageing of olive oil.


Asunto(s)
Ácidos Grasos/análisis , Almacenamiento de Alimentos , Peróxidos Lipídicos/análisis , Aceite de Oliva/análisis , Fenoles/análisis , Calidad de los Alimentos , Luz , Aceite de Oliva/metabolismo , Oxidación-Reducción , Temperatura , Factores de Tiempo
2.
Anal Chim Acta ; 642(1-2): 163-70, 2009 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-19427472

RESUMEN

As the jojoba oil was used in cosmetic, pharmaceutical, dietetic food, animal feeding, lubrication, polishing and bio-diesel fields, it was important to study its aging at high temperature by oxidative process. In this work a FT-MIR methodology was developed for monitoring accelerate oxidative degradation of jojoba oils. Principal component analysis (PCA) was used to differentiate various samples according to their origin and obtaining process, and to differentiate oxidative conditions applied on oils. Two spectroscopic indices were calculated to report simply the oxidation phenomenon. Results were confirmed and deepened by multivariate curve resolution-alternative least square method (MCR-ALS). It allowed identifying chemical species produced or degraded during the thermal treatment according to a SIMPLISMA pretreatment.


Asunto(s)
Espectroscopía Infrarroja por Transformada de Fourier/métodos , Ceras/química , Calor , Análisis de los Mínimos Cuadrados , Análisis Multivariante , Oxidación-Reducción , Análisis de Componente Principal , Programas Informáticos , Factores de Tiempo
3.
Talanta ; 77(5): 1748-56, 2009 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-19159793

RESUMEN

One of the most suitable analytical techniques used for edible oil quality control is Fourier transform mid infrared spectroscopy (FT-MIR). FT-MIR spectroscopy was used to continuously characterize the aging of various edible oils thanks to a specific aging cell. There were differences in the spectra of fresh and aged oils from different vegetable sources, which provide the basis of a method to classify them according to the oxidative spectroscopic index value. The use of chemometric treatment such as multivariate curve resolution-alternative least square (MCR-ALS) made it possible to extract the spectra of main formed and degraded species. The concentration profiles gave interesting information about the ability of the various oils to support the oxidative treatment and showed that all oils present the same aging process. Both methods led to concordant results in terms of induction times determined by the oxidative spectroscopic index and the appearance of oxidation products revealed by MCR-ALS.


Asunto(s)
Análisis de los Alimentos , Aceites de Plantas/normas , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Conservación de Alimentos , Oxidantes , Oxidación-Reducción
4.
Sci Total Environ ; 407(7): 2390-403, 2009 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-19167742

RESUMEN

Sewage treatment plants produce wastes resulting from the organic matter concentration in the form of sludge. A way of jointly treating and exploiting these increasing wastes jointly is the composting. Composting makes it possible to reduce volumes and the masses of wastes all while developing them in a product usable like organic soil enrichment. In this work, the composting process of an industrial sewage sludge composting plant was monitored to study the evolution of different physico-chemical parameters (temperature, moisture, pH, organic carbon, organic and inorganic nitrogen, organic carbon/organic nitrogen ratio, humic substances) and biochemical parameters (soluble fraction, hemicellulose, cellulose, lignin). Because these analyses are expensive and time consuming, we wanted to develop an alternative method to determine the maturity of compost related to compost properties with raw samples. Acceptable predictions were found for moisture, temperature, pH, organic carbon, organic carbon/organic nitrogen ratio, total-, organic- and ammoniacal nitrogen, fulvic- and humic acids and fulvic acids/humic acids ratio, but the error values were too high for the compost age to consider a quantification model. With regard to the biochemical parameters, this study is rather a preliminary test which shows the interest of the approach, but requires to be continued. Finally, the age of compost can be evaluated with Principal Component Analysis applied to NIR spectra.


Asunto(s)
Aguas del Alcantarillado/química , Suelo , Administración de Residuos/métodos , Carbono/análisis , Sustancias Húmicas/análisis , Concentración de Iones de Hidrógeno , Análisis de los Mínimos Cuadrados , Nitrógeno/análisis , Análisis de Componente Principal , Espectroscopía Infrarroja Corta , Temperatura
5.
Appl Spectrosc ; 62(7): 810-6, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18935833

RESUMEN

This study presents a new method for evaluating the oxidation of lubricating oils. An aging cell adapted to a Fourier transform infrared (FT-IR) spectrometer allows the continuous and direct study of the oxidative aging of base oils. During the test, oxidation bands appeared in the spectra (carbonyl bands around 1730 cm(-1)). The graphic representation of the carbonyl band modification--using a spectroscopic index--makes it possible to monitor the evolution of the lubricant composition. Comparing the oxidation constants, determined from the kinetic plots of several base oils, makes it possible to evaluate their relative sensitivity.

6.
Appl Spectrosc ; 62(5): 583-90, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18498701

RESUMEN

The combination of mid-infrared (MIR) spectroscopy with multivariate analysis provides an original approach to study the profile of virgin olive oils (VOOs) in relation to composition and geographical origin. Chemometric treatment of mid-infrared spectra (n=402) is assessed for quantification of fatty acids (14 components) and triacylglycerols (19 components) in VOO samples and for classification into six very geographically closed registered designations of origin (RDOs) of French VOO ("Aix-en-Provence", "Haute-Provence", "Vallée des Baux de Provence", "Nice", "Nîmes", and "Nyons"). Spectroscopic interpretation of regression vectors has shown that each RDO is correlated to one specific component of VOO according to their cultivar compositions. The results are satisfactory, in spite of the similarity of cultivar compositions between two denominations of origin ("Aix-en-Provence" and "Vallée des Baux de Provence"). Chemometric treatment of MIR spectra makes it possible to obtain similar results to those obtained by time-consuming analytical techniques such as gas chromatography (GC) and high-performance liquid chromatography (HPLC) and constitutes a fast and robust tool for authentication of these French VOOs.


Asunto(s)
Lípidos/análisis , Aceites de Plantas/química , Ácidos Grasos/análisis , Francia , Región Mediterránea , Aceite de Oliva , Aceites de Plantas/normas , Espectrofotometría Infrarroja , Triglicéridos/análisis
7.
Anal Chim Acta ; 595(1-2): 136-44, 2007 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-17605993

RESUMEN

The authentication of virgin olive oil samples requires usually the use of sophisticated and time consuming analytical techniques. There is a need for fast and simple analytical techniques for the objective of a quality control methodology. Virgin olive oils present characteristic NIR spectra. Chemometric treatment of NIR spectra was assessed for the quantification of fatty acids and triacylglycerols in virgin olive oil samples (n=125) and for their classification (PLS1-DA) into five very geographically closed registered designations of origin (RDOs) of French virgin olive oils ("Aix-en-Provence", "Haute-Provence", "Nice", "Nyons" and "Vallée des Baux"). The spectroscopic interpretation of regression vectors showed that each RDO was correlated to one or two specific components of virgin olive oils according to their cultivar compositions. The results were quite satisfactory, in spite of the similarity of cultivar compositions between two denominations of origin ("Aix-en-Provence" and "Vallée des Baux"). Chemometric treatments of NIR spectra allow us to obtain similar results than those obtained by time consuming analytical techniques such as GC and HPLC, and constitute a help fast and robust for authentication of those French virgin olive oils.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA