Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 150
Filtrar
1.
J Orthop Res ; 42(1): 148-163, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37442638

RESUMEN

The foot is responsible for the bodyweight transfer to the ground, while adapting to different terrains and activities. Despite this fundamental role, the knowledge about the foot bone intrinsic kinematics is still limited. The aim of the study is to provide a quantitative and systematic description of the kinematics of all bones in the foot, considering the full range of dorsi/plantar flexion and pronation/supination of the foot, both in weightbearing and nonweightbearing conditions. Bone kinematics was accurately reconstructed for three specimens from a series of computed tomography scans taken in weightbearing configuration. The ground inclination was imposed through a set of wedges, varying the foot orientation both in the sagittal and coronal planes; the donor body-weight was applied or removed by a cable-rig. A total of 32 scans for each foot were acquired and segmented. Bone kinematics was expressed in terms of anatomical reference systems optimized for the foot kinematic description. Results agree with previous literature where available. However, our analysis reveals that bones such as calcaneus, navicular, intermediate cuneiform, fourth and fifth metatarsal move more during foot pronation than flexion. Weightbearing significantly increase the range of motion of almost all the bone. Cuneiform and metatarsal move more due to weightbearing than in response to ground inclination, showing their role in the load-acceptance phase. The data here reported represent a step toward a deeper understanding of the foot behavior, that may help in the definition of better treatment and medical devices, as well as new biomechanical model of the foot.


Asunto(s)
Calcáneo , Huesos Metatarsianos , Fenómenos Biomecánicos , Pie/fisiología , Soporte de Peso/fisiología
2.
Gait Posture ; 108: 124-131, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38039867

RESUMEN

BACKGROUND: Lower extremity injuries rank among the most common injuries affecting young population, and numerous factors affect the outcomes of plantar pressure and balance assessment. RESEARCH QUESTION: Does a correlation exist between plantar pressure and postural balance in healthy subjects and are there any difference in the results based on gender and limb dominance? METHODS: This study involved thirty healthy recreationally active young adults (15 females, 15 males). Plantar pressures were analyzed using the MatScan Pressure Mat System, and postural balance was evaluated using Biodex Balance System. All assessments conducted under both static and dynamic conditions. Correlations were tested by Spearman Correlation Coefficient, and comparative tests were performed for gender and limb dominance. RESULTS: Correlations were observed between plantar pressure parameters and balance scores, particularly in the dynamic conditions (p < 0.05). Gender-based differences were noted in plantar pressure parameters (p < 0.05), with females demonstrating improved balance stability scores. No significant differences were found based on limb dominance in plantar pressure and postural balance data (p > 0.05). SIGNIFICANCE: This study provides valuable detailed insights into the existing literature concerning plantar pressure and postural balance assessments within the healthy population. A strong correlation was observed between plantar pressure and postural balance, and the comparisons of these assessments were affected by gender but not by limb dominance. These results could lead the way for better rehabilitation approaches by considering the correlations and differences across diverse populations.


Asunto(s)
Extremidades , Equilibrio Postural , Masculino , Femenino , Adulto Joven , Humanos , Estudios Transversales , Voluntarios Sanos , Modalidades de Fisioterapia
4.
Commun Biol ; 6(1): 1061, 2023 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-37857853

RESUMEN

The evolution of the medial longitudinal arch (MLA) is one of the most impactful adaptations in the hominin foot that emerged with bipedalism. When and how it evolved in the human lineage is still unresolved. Complicating the issue, clinical definitions of flatfoot in living Homo sapiens have not reached a consensus. Here we digitally investigate the navicular morphology of H. sapiens (living, archaeological, and fossil), great apes, and fossil hominins and its correlation with the MLA. A distinctive navicular shape characterises living H. sapiens with adult acquired flexible flatfoot, while the congenital flexible flatfoot exhibits a 'normal' navicular shape. All H. sapiens groups differentiate from great apes independently from variations in the MLA, likely because of bipedalism. Most australopith, H. naledi, and H. floresiensis navicular shapes are closer to those of great apes, which is inconsistent with a human-like MLA and instead might suggest a certain degree of arboreality. Navicular shape of OH 8 and fossil H. sapiens falls within the normal living H. sapiens spectrum of variation of the MLA (including congenital flexible flatfoot and individuals with a well-developed MLA). At the same time, H. neanderthalensis seem to be characterised by a different expression of the MLA.


Asunto(s)
Pie Plano , Hominidae , Adulto , Animales , Humanos , Hominidae/anatomía & histología , Pie/anatomía & histología , Fósiles
5.
J Orthop Surg Res ; 18(1): 742, 2023 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-37777776

RESUMEN

BACKGROUND: Custom-made implants are a valid option in revision total hip arthroplasty to address massive acetabular bone loss. The aim of this study was to assess the accuracy of custom-made acetabular implants between preoperative planning and postoperative positioning using CT scans. METHODS: In a retrospective analysis, three patients who underwent an acetabular custom-made prosthesis were identified. The custom-made designs were planned through 3D CT analysis considering surgical points of attention. The accuracy of intended implants positioning was assessed by comparing pre- and postoperative CT analyzing the center of rotation (CoR), anteversion, inclination, screws, and implant surface in contact with the bone. RESULTS: The three cases presented satisfactory accuracy in positioning. A malpositioning in the third case was observed due to the posterization of the CoR of the implant of more than 10 mm. The other CoR vectors considered in the third patient and all vectors in the other two cases fall within 10 mm. All the cases were positioned with a difference of less than 10° of anteversion and inclination with respect to the planning. CONCLUSIONS: The current case series revealed promising accuracy in the positioning of custom-made acetabular prosthesis comparing the planned implant in preoperative CT with postoperative CT.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Estudios Retrospectivos , Artroplastia de Reemplazo de Cadera/métodos , Reoperación , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Tomografía Computarizada por Rayos X
7.
Knee ; 44: 89-99, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37562120

RESUMEN

BACKGROUND: Patient specific devices represent a promising tool to improve accuracy and simplify high tibial osteotomy (HTO) procedures. The current study aims to assess accuracy of the correction of alignment and posterior tibial slope (PTS), and provide patient reported outcomes (PROMs) of a new personalised cutting guide and fixation plate (TOKA) system for HTO in patients with medial osteoarthritis (OA) and varus knee. METHODS: 25 patients (mean age 54.4 years) with medial OA and varus knee malalignment who underwent HTO with the TOKA system were prospectively evaluated pre-operatively, 1, 3, 6 and 12-months follow-up. Standing long-leg and lateral radiographs of the knee were used to assess the hip-knee-ankle (HKA) angle and the PTS, respectively. Accuracy was defined as the difference in planned minus achieved correction. The patient reported outcomes collected were the KOOS score, EQ5D, KSS score, and VAS pain scores. All statistical analyses were performed using IBM SPSS Statistics for Windows. RESULTS: The mean preoperative HKA was 170.7° (SD ± 3.2°); the mean postoperative HKA was 177.4° (SD ± 2.9°). The overall mean difference between planned and achieved correction in terms of HKA was 2.1° (SD ± 2.0°). The mean difference between planned and achieved PTS was 0.2° (SD ± 0.4°). All the assessed PROMs had a significant (p < 0.001) increase from the pre-operative value to postoperative evaluation and showed a significant (p < 0.001) improvement with follow-up time. CONCLUSIONS: TOKA personalised HTO system showed accurate correction in terms of both coronal and sagittal alignment, and excellent patient reported outcomes. LEVEL OF EVIDENCE: 4, prospective case series. Registration in public trial registry: registered at ClinicalTrial.gov [NCT04574570].


Asunto(s)
Osteoartritis de la Rodilla , Humanos , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Extremidad Inferior , Osteotomía/métodos , Estudios Retrospectivos
9.
Foot Ankle Clin ; 28(1S): e1-e14, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36935170

RESUMEN

The present review paper aimed at discussing the current major issues in total ankle replacement, both the technical and biomechanical concepts, and the surgical and clinical concerns. Designers shall target at the same time restoration of natural ankle kinematics and congruity of the artificial surfaces throughout the range of motion. Surgeons are recommended to expand biomechanical knowledge on ankle joint replacement, and provide appropriate training and key factors to make arthroplasty a good alternative to arthrodesis. Moreover, adequate selection of patients and careful rehabilitation are critical. In the future, custom-made prosthesis components and patient-specific instrumentation are major developments for more complex cases.


Asunto(s)
Artroplastia de Reemplazo de Tobillo , Prótesis Articulares , Humanos , Artroplastia de Reemplazo de Tobillo/efectos adversos , Fenómenos Biomecánicos , Resultado del Tratamiento , Articulación del Tobillo/cirugía , Diseño de Prótesis , Artrodesis
10.
Med Eng Phys ; 111: 103930, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36792235

RESUMEN

Despite showing promising functional outcomes for pelvic reconstruction after sarcoma resection, custom-made pelvic implants continue to exhibit high complication rates due to fixation failures. Patient-specific finite element models have been utilized by researchers to evaluate implant durability. However, the effect of assumed boundary and loading conditions on failure analysis results of fixation screws remains unknown. In this study, the postoperative stress distributions in the fixation screws of a state-of-the-art custom-made pelvic implant were simulated, and the risk of failure was estimated under various combinations of two bone-implant interaction models (tied vs. frictional contact) and four load cases from level-ground walking and stair activities. The study found that the average weighted peak von Mises stress could increase by 22-fold when the bone-implant interactions were modeled with a frictional contact model instead of a tied model, and the likelihood of fatigue and pullout failure for each screw could change dramatically when different combinations of boundary and loading conditions were used. The inclusion of additional boundary and loading conditions led to a more reliable analysis of fixation durability. These findings demonstrated the importance of simulating multiple boundary conditions and load cases for comprehensive implant design evaluation using finite element analysis.


Asunto(s)
Tornillos Óseos , Pelvis , Humanos , Análisis de Elementos Finitos , Pelvis/cirugía , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Estrés Mecánico
11.
Gait Posture ; 100: 268-275, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36682320

RESUMEN

BACKGROUND: Adult acquired flat foot (AAFF) is a symptomatic postural alteration of the foot due to modifications in bony structures and/or soft tissues supporting the medial longitudinal arch. For the most severe cases, when orthotic solutions do not provide enough pain relief, surgery may be necessary. RESEARCH QUESTION: Is it possible to restore a normal medial longitudinal arch and to correct the static and dynamic frontal plane alignment of the rearfoot via a modified Grice surgical procedure in AAFF patients? METHODS: Eleven patients with stage II AAFF were recruited in the study and underwent the Grice procedure. Patients were assessed via gait analysis using a validated multi-segment foot protocol. Double-leg standing static posture and foot joint kinematics during barefoot walking were measured before surgery and at a mean follow-up of 15 ± 8 months. Twenty-seven age-matched healthy subjects without foot morphological alterations were used as control. Patients' feet were clinically assessed via the Foot Function Index and the Foot Posture Index. Wilcoxon signed rank test was used to assess differences in kinematic and spatio-temporal parameters between pre-op and follow-up evaluations. 1D statistical parametric mapping was used to assess differences in temporal profiles of foot joint rotations. RESULTS: The clinical indexes significantly improved at post-op (p < 0.05). No differences in sagittal plane static and dynamic joint rotations were observed between pre-op and post-op. In the frontal plane, metatarsus to calcaneus and midfoot to calcaneus rotation angles significantly improved from pre-op to post-op, with the latter resulting consistent with control data. Range of motion and maximum value of the medial longitudinal arch angle were reduced following surgery. SIGNIFICANCE: The modified Grice procedure restored a good frontal-plane alignment of rearfoot and midfoot, and the clinical scores provided evidence of its effectiveness in significantly reducing pain and improving the quality of daily activities.


Asunto(s)
Pie Plano , Humanos , Adulto , Fenómenos Biomecánicos , Pie , Artrodesis , Dolor , Marcha
13.
J Clin Med ; 11(19)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36233583

RESUMEN

BACKGROUND: The accuracy of the coronal alignment corrections using conventional high tibial osteotomy (HTO) falls short, and multiplanar deformities of the tibia require consideration of both the coronal and sagittal planes. Patient-specific instrumentations have been introduced to improve the control of the correction. Clear evidence about customized devices for HTO and their correction accuracy lacks. METHODS: The databases PUBMED and EMBASE were systematically screened for human and cadaveric studies about the use of customized devices for high tibial osteotomy and their outcomes concerning correction accuracy. Furthermore, a 3D-printed customized system for valgus HTO with three pilot cases at one-year follow-up was presented. RESULTS: 28 studies were included. The most commonly used custom-made devices for HTO were found to be cutting guides. Reported differences between the achieved and targeted correction of hip-knee-ankle angle and the posterior tibial slope were 3° or under. The three pilot cases that underwent personalized HTO with a new 3D-printed device presented satisfactory alignment and clinical outcomes at one-year follow-up. CONCLUSION: The available patient-specific devices described in the literature, including the one used in the preliminary cases of the current study, showed promising results in increasing the accuracy of correction in HTO procedure.

14.
Sci Rep ; 12(1): 16900, 2022 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-36207422

RESUMEN

Cone-beam CT (CBCT) scans now enable accurate measurements on foot skeletal structures with the advantage of observing these in 3D and in weight-bearing. Among the most common skeletal deformities, the varus/valgus of the hindfoot is the most complex to be represented, and a number of measure proposals have been published. This study aims to analyze and to compare these measurements from CBCT scans in a real clinical population with large such deformity. Ten patients with severe acquired adult flatfoot and indication for surgery underwent CBCT scans (Carestream, USA) while standing on that leg, before and after surgical correction. Corresponding 3D shape of each bone of the distal shank and hindfoot were defined (Materialise, Belgium). Six different techniques from the literature were used to calculate the varus/valgus deformity, i.e. the inclination of the hindfoot in the frontal plane of the shank. Standard clinical measurements by goniometers were taken for comparison. According to these techniques, and starting from a careful 3D reconstruction of the relevant foot skeletal structures, a large spectrum of measurements was found to represent the same hindfoot alignment angle. Most of them were very different from the traditional clinical measures. The assessment of the pre-operative valgus deformity and of the corresponding post-operative correction varied considerably. CBCT finally allows 3D assessment of foot deformities in weight-bearing. Measurements from the different available techniques do not compare well, as they are based on very different approaches. It is recommended to be aware of the anatomical and functional concepts behind these techniques before clinical and surgical conclusions.


Asunto(s)
Pie Plano , Deformidades del Pie , Adulto , Tomografía Computarizada de Haz Cónico , Pie Plano/diagnóstico por imagen , Pie Plano/cirugía , Pie/diagnóstico por imagen , Humanos , Soporte de Peso
15.
Gait Posture ; 97: 73-79, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35914386

RESUMEN

BACKGROUND: Anatomical custom-made prostheses make it possible to reconstruct complicated bone defects following excision of bone tumors, thanks to 3D-printed technology. To date, clinical measures have been used to report clinical-functional outcome and provide evidence for the effectiveness of this new surgical approach. However, there are no studies that quantified the achievable recovery during common activities by using instrumental clinical-functional evaluation in these patients. RESEARCH QUESTION: What is the motor performance, functional outcome and quality of life in patients with custom-made 3D-printed pelvic prostheses following bone tumor? METHODS: To analyze motor performance, six patients performed motion analysis during five motor activities at follow-up of 32 ± 18 months. Joint angles, ground reaction forces and joint moments of the operated and contralateral limbs were compared. On-off activity of lower-limb muscles were calculated from electromyography and compared to a healthy matched population. To analyze functional outcome and quality of life, differences in measured hip abductor strength between limbs were evaluated, as well as clinical-functional scores (Harris Hip Score, Barthel Index, Musculoskeletal Tumor Society score), and quality of life (SF-36 health survey). RESULTS: We found only slight differences in joint kinematics when comparing operated and contralateral limb. The activity of gluteal muscles was normal, while hamstrings showed out-of-phase activities. Ground reaction forces and hip moments showed asymmetries between limbs, particularly in more demanding motor activities. We found a mean difference in hip abductor strength of 48 ± 82 N between limbs, good clinical-functional scores, and quality of life scores within normative. SIGNIFICANCE: Our study showed optimal long-term results in functional recovery, mainly achieved through recovery of the gluteal function, although minor impairments were found, which may be considered for future improvement of this innovative surgery. The effect of a more loaded contralateral limb on internal loads and long-term performance of the implant remains unknown and deserves further investigation.


Asunto(s)
Miembros Artificiales , Neoplasias Óseas , Neoplasias Óseas/patología , Neoplasias Óseas/cirugía , Humanos , Impresión Tridimensional , Calidad de Vida , Recuperación de la Función , Estudios Retrospectivos , Resultado del Tratamiento
16.
Front Bioeng Biotechnol ; 10: 862254, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35782520

RESUMEN

Objective: Osteoarthritis (OA) is a multifactorial musculoskeletal disorder affecting mostly weight-bearing joints. Chondrocyte response to load is modulated by inflammatory mediators and factors involved in extracellular cartilage matrix (ECM) maintenance, but regulatory mechanisms are not fully clarified yet. By using a recently proposed experimental model combining biomechanical data with cartilage molecular information, basally and following ex-vivo load application, we aimed at improving the understanding of human cartilage response to cyclic mechanical compressive stimuli by including cartilage original anatomical position and OA degree as independent factors. Methods: 19 mono-compartmental Knee OA patients undergoing total knee replacement were recruited. Cartilage explants from four different femoral condyles zones and with different degeneration levels were collected. The response of cartilage samples, pooled according to OA score and anatomical position was tested ex-vivo in a bioreactor. Mechanical stimulation was obtained via a 3-MPa 1-Hz sinusoidal compressive load for 45-min to replicate average knee loading during normal walking. Samples were analysed for chondrocyte gene expression and ECM factor release. Results: Non parametric univariate and multivariate (generalized linear mixed model) analysis was performed to evaluate the effect of compression and IL-1ß stimulation in relationship to the anatomical position, local disease severity and clinical parameters with a level of significance set at 0.05. We observed an anti-inflammatory effect of compression inducing a significant downmodulation of IL-6 and IL-8 levels correlated to the anatomical regions, but not to OA score. Moreover, ADAMTS5, PIICP, COMP and CS were upregulated by compression, whereas COL-2CAV was downmodulated, all in relationship to the anatomical position and to the OA degree. Conclusion: While unconfined compression testing may not be fully representative of the in-vivo biomechanical situation, this study demonstrates the importance to consider the original cartilage anatomical position for a reliable biomolecular analysis of knee OA metabolism following mechanical stimulation.

17.
J Foot Ankle Res ; 15(1): 38, 2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35585544

RESUMEN

Ankle-Foot Orthoses (AFO) can be prescribed to allow drop-foot patients to restore a quasi-normal gait pattern. Standard off-the-shelf AFOs are cost-effective solutions to treat most patients with foot and ankle weakness, but these devices have several limitations, especially in terms of comfort. Therefore, custom AFOs are increasingly adopted to address drop-foot when standard solutions are not adequate. While the solid ones are the most common type of AFO, providing full stability and strong resistance to ankle plantarflexion, passive dynamic AFOs (PD-AFOs) represent the ideal solution for patients with less severe ankle weakness. PD-AFOs have a flexible calf shell, which can bend during the stance phase of walking and absorb energy that can be released to support the limb in the push-off phase. The aim of this review is to assess the state-of-the-art and identify the current limitations of PD-AFOs. An extensive literature review was performed in Google Scholar to identify all studies on custom PD-AFOs. Only those papers reporting on custom PD-AFOs were included in the review. Non peer-reviewed papers, abstract shorter than three pages, lecture notes and thesis dissertations were excluded from the analysis. Particular attention was given to the customization principles and the mechanical and functional tests. For each topic, the main results from all relevant papers are reported and summarized herein. There were 75 papers that corresponded to the search criteria. These were grouped according to the following macro-topics: 16 focusing on scanning technologies and geometry acquisition; 14 on customization criteria; 19 on production techniques; 16 on mechanical testing, and 33 on functional testing. According to the present review, design and production of custom PD-AFOs are becoming increasingly feasible due to advancements in 3D scanning techniques and additive manufacturing. In general, custom PD-AFOs were shown to provide better comfort and improved spatio-temporal parameters with respect to standard solutions. However, no customization principle to adapt PD-AFO stiffness to the patient's degree of ankle impairment or mechanical/functional demand has thus far been proposed.


Asunto(s)
Ortesis del Pié , Tobillo , Articulación del Tobillo , Fenómenos Biomecánicos , Marcha , Humanos , Debilidad Muscular , Caminata
18.
Gait Posture ; 94: 144-152, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35334334

RESUMEN

BACKGROUND: A fully personalised combination of Gait Analysis (GA), including Ground Reaction Force (GRF), and patient-specific knee joint morphology has not yet been reported. This can provide valuable biomechanical insight in normal and pathological conditions. Abnormal knee varus results in medial knee condylar hyper-compression and osteoarthritis, which can be prevented by restoring proper condylar load distribution via High Tibial Osteotomy (HTO). RESEARCH QUESTION: This study was aimed at reporting on an original methodology, merging GA, GRF and Computer-Tomography (CT) to depict a patient-specific representation of the knee mechanical condition during locomotion. It was hypothesised that HTO results in a lateralized pattern of GRF with respect to the tibial plateau. METHODS: Four patients selected for HTO received clinical, radiological and instrumental examinations, pre- and post-operatively at 6-month follow-up. GA was performed during level walking and more demanding motor tasks using a 9-camera motion-capture system, combined with two force platforms, and an established protocol. Additional skin markers were positioned around the tibial-plateau rim. Weight-bearing CT scans of the knee were collected while still wearing these markers. Proximal tibial and marker morphological models were reconstructed. The markers from CT reconstruction were then registered to the corresponding trajectories as tracked by GA data. Resulting registration matrices were used to report GRF vectors on the plane best matching the tibial-plateau model and the intersection paths were calculated. RESULTS AND SIGNIFICANCE: The registration procedure was successfully executed, with a max registration error of about 3 mm. GRF intersection paths were found medially to the tibial plateau pre-op, and lateralized post-op, thus much closer to the knee centre, as expected after HTO. The exploitation of the present methodology offers personalised quantification of the original mechanical misalignment and of the effect of surgical correction which could enhance diagnostics and planning of HTO as well as other knee treatments.


Asunto(s)
Osteoartritis de la Rodilla , Análisis de la Marcha , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/cirugía , Osteotomía/métodos , Tibia/cirugía
19.
J Foot Ankle Res ; 14(1): 66, 2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34930383

RESUMEN

BACKGROUND: A complete definition of anatomical reference systems (ARS) for all bones of the foot and ankle complex is lacking. Using a morphological approach, we propose new ARS for these bones with the aim of being highly repeatable, consistent among individuals, clinically interpretable, and also suited for a sound kinematic description. METHODS: Three specimens from healthy donors and three patients with flat feet were scanned in weight-bearing CT. The foot bones were segmented and ARS defined according to the proposed approach. To assess repeatability, intra class coefficients (ICC) were computed both intra- and inter-operator. Consistency was evaluated as the mean of the standard deviations of the ARS position and orientation, both within normal and flat feet. Clinical interpretability was evaluated by providing a quantification of the curvature variation in the medial-longitudinal and transverse arches and computing the Djiann-Annonier angle for normal and flat feet from these new ARS axes. To test the capability to also provide a sound description of the foot kinematics, the alignment between mean helical axes (MHA) and ARS axes was quantified. RESULTS: ICC was 0.99 both inter- and intra-operator. Rotational consistency was 4.7 ± 3.5 ° and 6.2 ± 4.4° for the normal and flat feet, respectively; translational consistency was 4.4 ± 4.0 mm and 5.4 ± 2.9 mm for the normal and flat feet, respectively. In both these cases, the consistency was better than what was achieved by using principal axes of inertia. Curvature variation in the arches were well described and the measurements of the Djiann-Annoier angles from both normal and flat feet matched corresponding clinical observations. The angle between tibio-talar MHA and ARS mediolateral axis in the talus was 12.3 ± 6.0, while the angle between talo-calcaneal MHA and ARS anteroposterior axis in the calcaneus was 17.2 ± 5.6, suggesting good capability to represent joint kinematics. CONCLUSIONS: The proposed ARS definitions are robust and provide a solid base for the 3-dimensional description of posture and motion of the foot and ankle complex from medical imaging.


Asunto(s)
Calcáneo , Astrágalo , Tobillo , Articulación del Tobillo/diagnóstico por imagen , Calcáneo/diagnóstico por imagen , Humanos , Extremidad Inferior
20.
J Biomech ; 128: 110711, 2021 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-34481280

RESUMEN

Static and dynamic measurements of the medial longitudinal arch (MLA) in the foot are critical across different clinical and biomechanical research fields. While MLA deformation can be estimated using skin-markers for gait analysis, the current understanding of the correlates between skin-marker based models and radiographic measures of the MLA is limited. This study aimed at assessing the correlation and accuracy of skin-marker based measures of MLA deformation with respect to standard clinical X-ray based measures, used as reference. 20 asymptomatic subjects without morphological alterations of the foot volunteered in the study. A lateral X-ray of the right foot of each subject was taken in monopodalic upright posture with and without a metatarsophalangeal-joint dorsiflexing wedge. MLA angle was estimated in the two foot postures and during gait using 16 skin-marker based models, which were established according to the marker set of a validated multi-segment foot kinematic protocol. The error of each model in tracking MLA deformation was assessed and correlated with respect to standard radiographic measurements. Estimation of MLA deformation was highly affected by the skin-marker models. Skin-marker models using the marker on the navicular tuberosity as apex of the MLA angle showed the smallest errors (about 2 deg) and the largest correlations (R = 0.64-0.65; p < 0.05) with respect to the radiographic measurements. According to the outcome of this study, skin-marker based definitions of the MLA angle using the navicular tuberosity as apex of the arch may provide a more accurate estimation of MLA deformation with respect to that from radiographic measures.


Asunto(s)
Pie , Huesos Tarsianos , Fenómenos Biomecánicos , Pie/diagnóstico por imagen , Marcha , Humanos , Postura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...