MAGMA ; 32(3): 369-380, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30515641

RESUMEN

OBJECTIVE: Mild hyperthermia (HT) treatments are generally monitored by phase-referenced proton resonance frequency shift calculations. A novel phase and thus temperature-sensitive fast spin echo (TFSE) sequence is introduced and compared to the double echo gradient echo (DEGRE) sequence. THEORY AND METHODS: For a proton resonance frequency shift (PRFS)-sensitive TFSE sequence, a phase cycling method is applied to separate even from odd echoes. This method compensates for conductivity change-induced bias in temperature mapping as does the DEGRE sequence. Both sequences were alternately applied during a phantom heating experiment using the clinical setup for deep radio frequency HT (RF-HT). The B0 drift-corrected temperature values in a region of interest around temperature probes are compared to the temperature probe data and further evaluated in Bland-Altman plots. The stability of both methods was also tested within the thighs of three volunteers at a constant temperature using the subcutaneous fat layer for B0-drift correction. RESULTS: During the phantom heating experiment, on average TFSE temperature maps achieved double temperature-to-noise ratio (TNR) efficiency in comparison with DEGRE temperature maps. In-vivo images of the thighs exhibit stable temperature readings of ± 1 °C over 25 min of scanning in three volunteers for both methods. On average, the TNR efficiency improved by around 25% for in vivo data. CONCLUSION: A novel TFSE method has been adapted to monitor temperature during mild HT.


Asunto(s)
Hipertermia Inducida/métodos , Pelvis/diagnóstico por imagen , Protones , Ondas de Radio , Termografía/métodos , Conductividad Eléctrica , Diseño de Equipo , Calor , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Relación Señal-Ruido
2.
J Ther Ultrasound ; 4: 4, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26848391

RESUMEN

BACKGROUND: The study aims to investigate different ground plane segmentation designs of an ultrasound transducer to reduce gradient field induced eddy currents and the associated geometric distortion and temperature map errors in echo-planar imaging (EPI)-based MR thermometry in transcranial magnetic resonance (MR)-guided focused ultrasound (tcMRgFUS). METHODS: Six different ground plane segmentations were considered and the efficacy of each in suppressing eddy currents was investigated in silico and in operando. For the latter case, the segmented ground planes were implemented in a transducer mockup model for validation. Robust spoiled gradient (SPGR) echo sequences and multi-shot EPI sequences were acquired. For each sequence and pattern, geometric distortions were quantified in the magnitude images and expressed in millimeters. Phase images were used for extracting the temperature maps on the basis of the temperature-dependent proton resonance frequency shift phenomenon. The means, standard deviations, and signal-to-noise ratios (SNRs) were extracted and contrasted with the geometric distortions of all patterns. RESULTS: The geometric distortion analysis and temperature map evaluations showed that more than one pattern could be considered the best-performing transducer. In the sagittal plane, the star (d) (3.46 ± 2.33 mm) and star-ring patterns (f) (2.72 ± 2.8 mm) showed smaller geometric distortions than the currently available seven-segment sheet (c) (5.54 ± 4.21 mm) and were both comparable to the reference scenario (a) (2.77 ± 2.24 mm). Contrasting these results with the temperature maps revealed that (d) performs as well as (a) in SPGR and EPI. CONCLUSIONS: We demonstrated that segmenting the transducer ground plane into a star pattern reduces eddy currents to a level wherein multi-plane EPI for accurate MR thermometry in tcMRgFUS is feasible.

3.
J Magn Reson Imaging ; 42(1): 175-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25256847

RESUMEN

BACKGROUND: Inner volume (IV) excitation was explored with respect to scan time reduction of cardiac gated double inversion recovery multi-echo fast spin echo (MEFSE) to measure the transverse relaxation time (T2 ) in the myocardium. METHODS: The IV imaging was achieved by applying orthogonal slice selection for the excitation and refocusing pulses. The T2 map accuracy was investigated using different excitation and refocusing pulses. The performance of IV-MEFSE was compared with MEFSE on phantoms and eight healthy volunteers, acquiring eight echo times in a single breath-hold. RESULTS: Compared with MEFSE, IV-MEFSE allowed a scan time reduction from 26 s to 16 s, but caused a T2 overestimation of approximately 10% due to stimulated echoes. CONCLUSION: IV successfully reduced the scan time to a single breath-hold feasible for many patients and remarkably facilitated the scan prescription, because there was no image aliasing concern. Care should be taken in using IV for T2 mapping because of T2 relaxation time overestimation.


Asunto(s)
Algoritmos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Corazón/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad