Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Intervalo de año de publicación
1.
Innovations (Phila) ; 18(5): 494-497, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37610181

RESUMEN

Trapped prosthetic valve leaflets are a rare but challenging complication. A 68-year-old male patient had previously undergone redo aortic valve replacement. Postoperatively, he decompensated with severe mitral regurgitation, requiring extracorporeal membrane oxygenation and a salvage mitral valve replacement via right thoracotomy with very difficult access. This procedure was complicated by a trapped valve leaflet. He recovered well initially but presented 2 years later with worsening heart failure due to mitral stenosis and rising pulmonary artery pressures. Due to the high risk of sternotomy and right thoracotomy, a transventricular cardioscopic release of the trapped mitral valve leaflet was undertaken by left minithoracotomy. The procedure was successful, and the patient was discharged home on day 12. This novel minimally invasive approach, which does not require myocardial preservation, is ideal for high-risk patients with this rare complication and has not previously been described. We hope that by sharing our experience, others will consider this innovative approach.

2.
PLoS One ; 17(7): e0271958, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35881612

RESUMEN

BACKGROUND: Neutrophil activation drives lung complications after cardiopulmonary bypass (CPB). Evidence suggests the healthy, ventilated lung may beneficially re-condition pro-inflammatory neutrophils. However, evidence in humans is lacking, due to a paucity of good models. CPB with simultaneous central venous and bilateral pulmonary vein sampling provides an opportunity to model effects of one-lung ventilation. The study's primary objectives were to establish a model of intra-operative, bilateral pulmonary vein sampling and to determine whether neutrophil function differed after passing through inflated or deflated lungs. METHODS: Seventeen patients having "on pump" coronary artery bypass grafting (CABG) with one-lung ventilation (in two cohorts with tidal volume 2ml kg-1 and FiO2 0.21, or tidal volume 4 ml kg-1 and FiO2 0.5 respectively) were recruited. Cohort 1 consisted of 9 patients (7 male, median age 62.0 years) and Cohort 2 consisted of 8 male patients (median age 65.5 years). Recruitment was via prospective screening of scheduled elective and non-elective CABG procedures with cardiopulmonary bypass. Each patient had five blood samples taken-central venous blood pre-operatively; central venous blood pre-CPB; central venous blood post-CPB; pulmonary venous blood draining the ventilated lung post-CPB; and pulmonary venous blood draining the deflated lung post-CPB. Neutrophil phagocytosis and priming status were quantified. Plasma cytokines were measured. RESULTS: Phagocytosis and priming were not significantly different in neutrophils returning from the ventilated lung as compared to the non-ventilated lung. Plasma IL-6, IL-8 and IL-10 were significantly elevated by CPB. CONCLUSIONS: The intra-operative, bilateral pulmonary vein sampling model provides unique opportunities to assess biological effects of interventions to one lung, with the other lung acting as an internal control. Single-lung ventilation during CPB had no significant effects on neutrophil function.


Asunto(s)
Ventilación Unipulmonar , Venas Pulmonares , Anciano , Puente Cardiopulmonar/efectos adversos , Puente Cardiopulmonar/métodos , Humanos , Masculino , Persona de Mediana Edad , Neutrófilos , Oxígeno , Estudios Prospectivos , Venas Pulmonares/cirugía
3.
Braz J Cardiovasc Surg ; 33(2): 122-128, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29898140

RESUMEN

OBJECTIVE: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. METHODS: From January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG). RESULTS: Patients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. CONCLUSION: In our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/normas , Prótesis Valvulares Cardíacas/normas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Puente Cardiopulmonar/métodos , Constricción , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Diseño de Prótesis , Reproducibilidad de los Resultados , Estudios Retrospectivos , Esternotomía/métodos , Procedimientos Quirúrgicos sin Sutura/métodos , Factores de Tiempo , Resultado del Tratamiento
4.
Braz J Cardiovasc Surg ; 33(2): 169-175, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29898147

RESUMEN

INTRODUCTION: The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR. METHODS: The data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017. RESULTS: Cardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A. CONCLUSION: The implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.


Asunto(s)
Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/etiología , Trombocitopenia/etiología , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Puente Cardiopulmonar/efectos adversos , Constricción , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Recuento de Plaquetas , Diseño de Prótesis , Estudios Retrospectivos , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/métodos , Factores de Tiempo , Resultado del Tratamiento
5.
Braz J Cardiovasc Surg ; 33(1): 8-14, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29617495

RESUMEN

OBJECTIVE: The aim of this retrospective study is to evaluate the safety and performance of the Perceval sutureless valve in patients undergoing aortic valve replacement. We report the 30-day clinical outcomes of 139 patients. METHODS: From January 2014 to December 2016, 139 patients underwent sutureless aortic valve replacement. Their operation notes, National Adult Cardiac Surgery Database and perioperative transoesophageal echocardiography findings were studied retrospectively. RESULTS: Ninety-two patients underwent isolated aortic valve replacement (group A) with Perceval valve and 47 patients had combined procedures of aortic valve replacement and coronary artery bypass grafting (group B). The patients received a size S (n=23), M (n=39), L (n=42) or XL (n=35) prosthesis. Perceval valve was successfully implanted in 135 (97.1%) patients. Mean cross-clamping time and bypass time were 40 and 63 minutes for isolated cases, while 68 and 107 minutes for combined cases. Three (2.1%) patients died within 30 days. Four patients suffered stroke and 5 patients went into acute renal failure. Median intensive care unit and hospital stay was 2 and 8.5, respectively. Four valves were explanted due to significant paravalvular leak after surgery. Five patients had permanent pacemaker as a result of complete heart block and mean postoperative drainage was 295 mL for isolated case and 457 mL for combined cases. The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. CONCLUSION: Early postoperative results showed that Perceval valve is safe. Further follow up is needed to evaluate the long-term outcome with this bioprosthesis.


Asunto(s)
Bioprótesis , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Procedimientos Quirúrgicos sin Sutura , Anciano , Anciano de 80 o más Años , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
6.
Rev. bras. cir. cardiovasc ; 33(2): 169-175, Mar.-Apr. 2018. tab
Artículo en Inglés | LILACS | ID: biblio-958397

RESUMEN

Abstract Introduction: The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR. Methods: The data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017. Results: Cardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A. Conclusion: The implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Complicaciones Posoperatorias/etiología , Trombocitopenia/etiología , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Aórtica/cirugía , Recuento de Plaquetas , Diseño de Prótesis , Factores de Tiempo , Puente Cardiopulmonar/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Constricción , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/métodos
7.
Rev. bras. cir. cardiovasc ; 33(2): 122-128, Mar.-Apr. 2018. tab
Artículo en Inglés | LILACS | ID: biblio-958395

RESUMEN

Abstract Objective: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. Methods: From January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG). Results: Patients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. Conclusion: In our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/normas , Prótesis Valvulares Cardíacas/normas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Periodo Posoperatorio , Diseño de Prótesis , Factores de Tiempo , Puente Cardiopulmonar/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Resultado del Tratamiento , Constricción , Esternotomía/métodos , Procedimientos Quirúrgicos sin Sutura/métodos
8.
Rev. bras. cir. cardiovasc ; 33(1): 8-14, Jan.-Feb. 2018. tab
Artículo en Inglés | LILACS | ID: biblio-897988

RESUMEN

Abstract Objective: The aim of this retrospective study is to evaluate the safety and performance of the Perceval sutureless valve in patients undergoing aortic valve replacement. We report the 30-day clinical outcomes of 139 patients. Methods: From January 2014 to December 2016, 139 patients underwent sutureless aortic valve replacement. Their operation notes, National Adult Cardiac Surgery Database and perioperative transoesophageal echocardiography findings were studied retrospectively. Results: Ninety-two patients underwent isolated aortic valve replacement (group A) with Perceval valve and 47 patients had combined procedures of aortic valve replacement and coronary artery bypass grafting (group B). The patients received a size S (n=23), M (n=39), L (n=42) or XL (n=35) prosthesis. Perceval valve was successfully implanted in 135 (97.1%) patients. Mean cross-clamping time and bypass time were 40 and 63 minutes for isolated cases, while 68 and 107 minutes for combined cases. Three (2.1%) patients died within 30 days. Four patients suffered stroke and 5 patients went into acute renal failure. Median intensive care unit and hospital stay was 2 and 8.5, respectively. Four valves were explanted due to significant paravalvular leak after surgery. Five patients had permanent pacemaker as a result of complete heart block and mean postoperative drainage was 295 mL for isolated case and 457 mL for combined cases. The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. Conclusion: Early postoperative results showed that Perceval valve is safe. Further follow up is needed to evaluate the long-term outcome with this bioprosthesis.


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Procedimientos Quirúrgicos sin Sutura , Enfermedades de las Válvulas Cardíacas/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
9.
Heart Surg Forum ; 7(5): E446-9, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15799921

RESUMEN

BACKGROUND: No-React treatment is known to render tissues resistant to calcific degeneration and to reduce early inflammatory response. No-React bovine internal mammary artery (NR-IMA) is available for restricted use in Europe. In this first study, our aim was to use magnetic resonance imaging (MRI) to investigate the clinical performance and patency rates of this conduit. METHODS: Seven patients received 8 grafts with NR-IMA. Approval from the Medical Devices Agency of the United Kingdom was obtained for use of this material. One patient needed salvage coronary artery bypass grafting (CABG). Graft patency was investigated with cardiac MRI. One patient was excluded from the MRI study because of the presence of intracerebral metal clips. The mean follow-up period was 2.5 years with a range of 1 to 4.5 years. RESULTS: There was no mortality in this group. After treatment 6 patients were asymptomatic, and 1 patient had class II anginal symptoms. Four (57%) of the 7 NR-IMA grafts remained patent. The longest patency was 4.5 years in a patient who underwent salvage CABG. Other associated grafts in this cohort of patients were 5 left internal mammary arteries (all patent), 1 radial artery graft (patent), and 7 saphenous vein grafts (4 [57%] of 7 patent). There were no occluded NR-IMA grafts in a patient with patent vein grafts. CONCLUSION: We concluded that at 2.5 year follow-up, NR-IMA had a patency rate of 57% (4 of 7 cases). This rate matched the vein graft patency rate in this cohort of patients. With the longest patency of 4.5 years, use of NR-IMA seems to hold promise for the future.


Asunto(s)
Prótesis Vascular , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Arterias Mamarias/trasplante , Revascularización Miocárdica/instrumentación , Revascularización Miocárdica/métodos , Recolección de Tejidos y Órganos/métodos , Anciano , Anciano de 80 o más Años , Animales , Bovinos , Femenino , Humanos , Masculino , Proyectos Piloto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA