Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 427
Filtrar
1.
Nature ; 629(8013): 791-797, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38720077

RESUMEN

Emerging spatial computing systems seamlessly superimpose digital information on the physical environment observed by a user, enabling transformative experiences across various domains, such as entertainment, education, communication and training1-3. However, the widespread adoption of augmented-reality (AR) displays has been limited due to the bulky projection optics of their light engines and their inability to accurately portray three-dimensional (3D) depth cues for virtual content, among other factors4,5. Here we introduce a holographic AR system that overcomes these challenges using a unique combination of inverse-designed full-colour metasurface gratings, a compact dispersion-compensating waveguide geometry and artificial-intelligence-driven holography algorithms. These elements are co-designed to eliminate the need for bulky collimation optics between the spatial light modulator and the waveguide and to present vibrant, full-colour, 3D AR content in a compact device form factor. To deliver unprecedented visual quality with our prototype, we develop an innovative image formation model that combines a physically accurate waveguide model with learned components that are automatically calibrated using camera feedback. Our unique co-design of a nanophotonic metasurface waveguide and artificial-intelligence-driven holographic algorithms represents a significant advancement in creating visually compelling 3D AR experiences in a compact wearable device.


Asunto(s)
Algoritmos , Realidad Aumentada , Holografía , Holografía/métodos , Holografía/instrumentación , Color , Inteligencia Artificial , Imagenología Tridimensional , Humanos , Calibración
2.
Medicine (Baltimore) ; 103(18): e38026, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38701308

RESUMEN

As point-of-care ultrasound (POCUS) is increasingly being used in clinical settings, ultrasound education is expanding into student curricula. We aimed to determine the status and awareness of POCUS education in Korean medical schools using a nationwide cross-sectional survey. In October 2021, a survey questionnaire consisting of 20 questions was distributed via e-mail to professors in the emergency medicine (EM) departments of Korean medical schools. The questionnaire encompassed 19 multiple-choice questions covering demographics, current education, perceptions, and barriers, and the final question was an open-ended inquiry seeking suggestions for POCUS education. All EM departments of the 40 medical schools responded, of which only 13 (33%) reported providing POCUS education. The implementation of POCUS education primarily occurred in the third and fourth years, with less than 4 hours of dedicated training time. Five schools offered a hands-on education. Among schools offering ultrasound education, POCUS training for trauma cases is the most common. Eight schools had designated professors responsible for POCUS education and only 2 possessed educational ultrasound devices. Of the respondents, 64% expressed the belief that POCUS education for medical students is necessary, whereas 36%, including those with neutral opinions, did not anticipate its importance. The identified barriers to POCUS education included faculty shortages (83%), infrastructure limitations (76%), training time constraints (74%), and a limited awareness of POCUS (29%). POCUS education in Korean medical schools was limited to a minority of EM departments (33%). To successfully implement POCUS education in medical curricula, it is crucial to clarify learning objectives, enhance faculty recognition, and improve the infrastructure. These findings provide valuable insights for advancing ultrasound training in medical schools to ensure the provision of high-quality POCUS education for future healthcare professionals.


Asunto(s)
Curriculum , Sistemas de Atención de Punto , Facultades de Medicina , Ultrasonografía , Estudios Transversales , Humanos , República de Corea , Ultrasonografía/estadística & datos numéricos , Encuestas y Cuestionarios , Medicina de Emergencia/educación
3.
Bioact Mater ; 38: 331-345, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38764447

RESUMEN

Cellular reprogramming technologies have been developed with different physicochemical factors to improve the reprogramming efficiencies of induced pluripotent stem cells (iPSCs). Ultrasound is a clinically applied noncontact biophysical factor known for regulating various cellular behaviors but remains uninvestigated for cellular reprogramming. Here, we present a new reprogramming strategy using low-intensity ultrasound (LIUS) to improve cellular reprogramming of iPSCs in vitro and in vivo. Under 3D microenvironment conditions, increased LIUS stimulation shows enhanced cellular reprogramming of the iPSCs. The cellular reprogramming process facilitated by LIUS is accompanied by increased mesenchymal to epithelial transition and histone modification. LIUS stimulation transiently modulates the cytoskeletal rearrangement, along with increased membrane fluidity and mobility to increase HA/CD44 interactions. Furthermore, LIUS stimulation with HA hydrogel can be utilized in application of both human cells and in vivo environment, for enhanced reprogrammed cells into iPSCs. Thus, LIUS stimulation with a combinatorial 3D microenvironment system can improve cellular reprogramming in vitro and in vivo environments, which can be applied in various biomedical fields.

4.
Bone Joint J ; 106-B(5): 475-481, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38688515

RESUMEN

Aims: The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan. Methods: We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured. Results: Out of 37 ankles, graft incorporation was successful in 30 cases. Among the remaining seven cases, four (10.8%) exhibited cyst re-progression, so secondary bone grafting was needed. After secondary bone grafting, no further progression has been noted, resulting in an overall 91.9% success rate (34 of 37) at a mean follow-up period of 47.5 months (24 to 120). The remaining three cases (8.1%) showed implant loosening, so tibiotalocalcaneal arthrodesis was performed. Functional outcomes were also improved after bone grafting in all variables at the latest follow-up (p < 0.05). The mean incorporation rate of the grafts according to the location of the cysts was 84.8% (55.2% to 96.1%) at the medial malleolus, 65.1% (27.6% to 97.1%) at the tibia, and 81.2% (42.8% to 98.7%) at the talus. Smoking was identified as a significant predisposing factor adversely affecting graft incorporation (p = 0.001). Conclusion: Bone grafting for periprosthetic bone cysts following primary TAA is a reliable procedure with a satisfactory success rate and functional outcomes. Regular follow-up, including CT scan, is important for the detection of cyst re-progression to prevent implant loosening after bone grafting.


Asunto(s)
Artroplastia de Reemplazo de Tobillo , Quistes Óseos , Trasplante Óseo , Tomografía Computarizada por Rayos X , Humanos , Artroplastia de Reemplazo de Tobillo/métodos , Artroplastia de Reemplazo de Tobillo/efectos adversos , Quistes Óseos/cirugía , Quistes Óseos/diagnóstico por imagen , Quistes Óseos/etiología , Femenino , Masculino , Persona de Mediana Edad , Trasplante Óseo/métodos , Anciano , Estudios Retrospectivos , Adulto , Resultado del Tratamiento , Articulación del Tobillo/cirugía , Articulación del Tobillo/diagnóstico por imagen , Estudios de Seguimiento
5.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38674258

RESUMEN

Background and Objectives: The European Kidney Function Consortium (EKFC) equation has been newly proposed for estimating glomerular filtration rate (eGFR) across the spectrum of age. We compared the EKFC equation with the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations in a large-scale Korean population. Materials and Methods: Using the representative Korean health examination data, the Korea National Health and Nutrition Examination Survey (KNHANES 2008-2021), the records of 91,928 subjects (including 9917 children) were analyzed. We compared the EKFC equation with CKiD, CKD-EPI 2009, and CKD-EPI 2021 equations and investigated their agreement across GFR categories. Results: In the total population, the CKD-EPI 2021 equation yielded the highest eGFR value, followed by the CKD-EPI 2009 and EKFC equations. In children, the distribution of eGFR differed significantly between the EKFC and CKiD equations (p < 0.001), with a wider range of eGFR values found with the CKiD equation. Each equation showed weak or moderate agreement on the frequency of the GFR category (κ = 0.54 between EKFC and CKD-EPI 2021; κ = 0.77 between EKFC and CKD-EPI 2009). The eGFR values found by the EKFC equation showed high or very high correlations with those by the CKiD, CKD-EPI 2009, and CKD-EPI 2021 equations (r = 0.85, 0.97, and 0.97, respectively). As eGFR values increased, bigger differences were observed between equations. Conclusions: This large-scale study demonstrates that the EKFC equation would be applicable across the entire age spectrum in Asian populations. It also underscores that national kidney health would be highly affected by an eGFR equation being implemented. Additional investigation and more caution would be warranted for the transition of eGFR equations.


Asunto(s)
Tasa de Filtración Glomerular , Encuestas Nutricionales , Insuficiencia Renal Crónica , Humanos , República de Corea/epidemiología , Masculino , Femenino , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/epidemiología , Niño , Adulto , Persona de Mediana Edad , Adolescente , Anciano , Pruebas de Función Renal/métodos , Pruebas de Función Renal/estadística & datos numéricos , Pruebas de Función Renal/normas , Preescolar , Adulto Joven
6.
Microorganisms ; 12(4)2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38674621

RESUMEN

Epidemic diseases that arise from infectious RNA viruses, particularly influenza viruses, pose a constant threat to the global economy and public health. Viral evolution has undermined the efficacy of acquired immunity from vaccines and the antiviral effects of FDA-approved drugs. As such, there is an urgent need to develop new antiviral lead agents. Natural compounds, owing to their historical validation of application and safety, have become a promising solution. In this light, a novel marine bacterium, Pseudomonas sp. M20A4R8, has been found to exhibit significant antiviral activity [half maximal inhibitory concentration (IC50) = 1.3 µg/mL, selectivity index (SI) = 919.4] against influenza virus A/Puerto Rico/8/34, surpassing the activity of chloroquine. The antiviral response via M20A4R8 extract was induced during post-entry stages of the influenza virus, indicating suitability for post-application after the establishment of viral infection. Furthermore, post-treatment with M20A4R8 extract protected the host from virus-induced apoptosis, suggesting its potential use in acute respiratory disease complexes resulting from immune effectors' overstimulation and autophagy-mediated self-apoptosis. The extract demonstrated an outstanding therapeutic index against influenza virus A/Wisconsin/15/2009 (IC50 = 8.1 µg/mL, SI = 146.2) and B/Florida/78/2015 Victoria lineage (IC50 = 3.5 µg/mL, SI = 343.8), indicating a broad anti-influenza virus activity with guaranteed safety and effectiveness. This study provides a new perspective on mechanisms for preventing a broad spectrum of viral infections through antiviral agents from novel and natural origins. Future studies on a single or combined compound from the extract hold promise, encouraging its use in preclinical challenge tests with various influenza virus strains.

7.
J Clin Lab Anal ; 38(7): e25034, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38525919

RESUMEN

BACKGROUND: Accurate quantification of the BCR::ABL1 transcripts is essential for measurable residual disease (MRD) monitoring in chronic myeloid leukemia (CML) after tyrosine kinase inhibitor (TKI) treatment. This study evaluated the newly developed digital real-time PCR method, Dr. PCR, as an alternative reverse transcription-PCR (qRT-PCR) for MRD detection. METHODS: The performance of Dr. PCR was assessed using reference and clinical materials. Precision, linearity, and correlation with qRT-PCR were evaluated. MRD levels detected by Dr. PCR were compared with qRT-PCR, and practical advantages were investigated. RESULTS: Dr. PCR detected MRD up to 0.0032%IS (MR4.5) with excellent precision and linearity and showed a strong correlation with qRT-PCR results. Notably, Dr. PCR identified higher levels of MRD in 12.7% (29/229) of patients than qRT-PCR, including six cases of MR4, which is a critical level for TKI discontinuation. Dr. PCR also allowed for sufficient ABL1 copies in all cases, while qRT-PCR necessitated multiple repeat tests in 3.5% (8/229) of cases. CONCLUSION: Our study provides a body of evidence supporting the clinical application of Dr. PCR as a rapid and efficient method for assessing MRD in patients with CML under the current treatment regimen.


Asunto(s)
Proteínas de Fusión bcr-abl , Leucemia Mielógena Crónica BCR-ABL Positiva , Neoplasia Residual , Reacción en Cadena en Tiempo Real de la Polimerasa , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Proteínas de Fusión bcr-abl/genética , Leucemia Mielógena Crónica BCR-ABL Positiva/genética , Leucemia Mielógena Crónica BCR-ABL Positiva/tratamiento farmacológico , Neoplasia Residual/genética , Reproducibilidad de los Resultados
8.
Diagnostics (Basel) ; 14(6)2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38535013

RESUMEN

BACKGROUND: Few studies have evaluated digital morphology (DM) analyzers on body fluids (BF). We evaluated the performance of a DM analyzer, Sysmex DI-60 (Sysmex, Kobe, Japan) for white blood cell (WBC) differentials in BF samples. METHODS: In five BF samples (two pleural fluids and three ascites) containing a single, dominant cell type (>80%, neutrophils, lymphocytes, macrophages, abnormal lymphocytes, and malignant cells in each sample), we evaluated the precision of the DI-60 and compared the WBC differentials and turnaround times (TAT) between DI-60 and manual counting. RESULTS: The precision of the DI-60 pre-classification and verification was excellent (%CV, 0.01-3.16%). After verification, the DI-60 showed high sensitivity, specificity, and efficiency (ranges: 90.8-98.1%, 96.8-97.9%, and 92.5-98.0%, respectively) for the dominant cell types in neutrophil- and lymphocyte-dominant samples. For all samples, the DI-60 and manual counting showed high correlations for major cell types (neutrophils, lymphocytes, macrophages, and others, r = 0.72 to 0.94) after verification. The agreement between the pre-classification and verification of the DI-60 was strong in the neutrophil-dominant sample (κ = 0.81). The DI-60 showed a significantly longer TAT (min: s) than manual counting for all samples (median TAT/slide: 6:28 vs. 1:53, p < 0.0001), with remarkable differences in abnormal lymphocyte- and malignant cell-dominant samples (21:05 vs. 2:06; 12:34 vs. 2:25). CONCLUSIONS: The DI-60 may provide reliable data in neutrophil- and lymphocyte-dominant BF samples. However, it may require longer times and higher workloads for WBC differentials especially in BF samples containing atypical cells. Further improvement would be needed before applying DM analyzers for routine clinical practice in BF analysis.

9.
J Microbiol Biotechnol ; 34(3): 562-569, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38247219

RESUMEN

Xanthomonas oryzae pv. oryzae (Xoo) causes a devastating bacterial leaf blight in rice. Here, the antimicrobial effects of D-limonene, L-limonene, and its oxidative derivative carveol against Xoo were investigated. We revealed that carveol treatment at ≥ 0.1 mM in liquid culture resulted in significant decrease in Xoo growth rate (> 40%) in a concentration-dependent manner, and over 1 mM, no growth was observed. The treatment with D-limonene and L-limonene also inhibited the Xoo growth but to a lesser extent compared to carveol. These results were further elaborated with the assays of motility, biofilm formation and xanthomonadin production. The carveol treatment over 1 mM caused no motilities, basal level of biofilm formation (< 10%), and significantly reduced xanthomonadin production. The biofilm formation after the treatment with two limonene isomers was decreased in a concentration-dependent manner, but the degree of the effect was not comparable to carveol. In addition, there was negligible effect on the xanthomonadin production mediated by the treatment of two limonene isomers. Field emission-scanning electron microscope (FE-SEM) unveiled that all three compounds used in this study cause severe ultrastructural morphological changes in Xoo cells, showing shrinking, shriveling, and holes on their surface. Moreover, quantitative real-time PCR revealed that carveol and D-limonene treatment significantly down-regulated the expression levels of genes involved in virulence and biofilm formation of Xoo, but not with L-limonene. Together, we suggest that limonenes and carveol will be the candidates of interest in the development of biological pesticides.


Asunto(s)
Monoterpenos Ciclohexánicos , Oryza , Xanthomonas , Limoneno/farmacología , Limoneno/metabolismo , Antibacterianos/farmacología , Antibacterianos/metabolismo , Oryza/microbiología , Enfermedades de las Plantas/prevención & control , Enfermedades de las Plantas/microbiología
10.
J Int Med Res ; 52(1): 3000605231223881, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38206194

RESUMEN

OBJECTIVE: Deep learning is an advanced machine-learning approach that is used in several medical fields. Here, we developed a deep learning model using an object detection algorithm to identify the L5 vertebra on anteroposterior lumbar spine radiographs, and assessed its detection accuracy. METHODS: We retrospectively recruited 150 participants for whom both anteroposterior whole-spine and lumbar spine radiographs were available. The anteroposterior lumbar spine radiographs of these patients were used as the input data. Of the 150 images, 105 (70%) were randomly selected as the training set, and the remaining 45 (30%) were assigned to the validation set. YOLOv5x, of the YOLOv5 family model, was used to detect the L5 vertebra area. RESULTS: The mean average precisions 0.5 and 0.75 of the trained L5 detection model were 99.2% and 96.9%, respectively. The model's precision was 95.7% and its recall was 97.8%. Furthermore, 93.3% of the validation data were correctly detected. CONCLUSION: Our deep learning model showed an outstanding ability to identify L5 vertebrae.


Asunto(s)
Aprendizaje Profundo , Humanos , Estudios Retrospectivos , Vértebras Lumbares/diagnóstico por imagen , Región Lumbosacra , Radiografía
11.
Am J Clin Pathol ; 161(2): 111-114, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37852281

RESUMEN

OBJECTIVES: Identification of DNT, a rare partial D, can be challenging, as it is difficult to distinguish from D+. This study aimed to identify DNT individuals by analyzing the DNT proband's family members, characterize DNT, and propose management strategies. METHODS: Family members of the first Korean DNT proband were recruited. RHD genotyping was conducted, and weak D tests were carried out using several anti-D reagents. RESULTS: Three DNT individuals were identified among 6 family members, including 1 with an anti-D alloantibody. As DNT red cells exhibited strong reactivity with all anti-D clones, DNT was serologically indistinguishable from D+. Moreover, unusual serologic findings in DNT individuals only became apparent after anti-D alloimmunization. CONCLUSIONS: We recommend DNT individuals as candidates for Rh immune globulin prophylaxis during the perinatal period and transfusions with D- blood components. An anticipatory RHD genotyping is suggested for partial D family members to prevent potential partial D individuals from becoming alloimmunized.


Asunto(s)
Sistema del Grupo Sanguíneo Rh-Hr , Globulina Inmune rho(D) , Embarazo , Femenino , Humanos , Genotipo , Sistema del Grupo Sanguíneo Rh-Hr/genética , República de Corea
12.
Clin Chem Lab Med ; 62(5): 958-966, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38000045

RESUMEN

OBJECTIVES: White blood cell (WBC)-related flags are essential for detecting abnormal cells including blasts in automated hematology analyzers (AHAs). Cell population data (CPD) may characterize each WBC population, and customized CPD rules can be also useful for detecting blasts. We evaluated the performance of WBC-related flags, customized CPD rules, and their combination for detecting blasts on the Beckman Coulter DxH 900 AHA (DxH 900, Beckman Coulter, Miami, Florida, USA). METHODS: In a total of 239 samples from patients with hematologic diseases, complete blood count on DxH 900 and manual slide review (MSR) were conducted. The sensitivity, specificity, and efficiency of the five WBC-related flags, nine customized CPD rules, and their combination were evaluated for detecting blasts, in comparison with MSR. RESULTS: Blasts were detected by MSR in 40 out of 239 (16.7 %) samples. The combination of flags and CPD rules showed the highest sensitivity compared with each of flags and CPD rules for detecting blasts (97.5 vs. 72.5 % vs. 92.5 %). Compared with any flag, the combination of flags and CPD rules significantly reduced false-negative samples from 11 to one for detecting blasts (27.5 vs. 2.5 %, p=0.002). CONCLUSIONS: This is the first study that evaluated the performance of both flags and CPD rules on DxH 900. The customized CPD rules as well as the combination of flags and CPD rules outperformed WBC-related flags for detecting blasts on DxH 900. The customized CPD rules can play a complementary role for improving the capability of blast detection on DxH 900.


Asunto(s)
Enfermedades Hematológicas , Hematología , Humanos , Recuento de Células Sanguíneas , Enfermedades Hematológicas/diagnóstico , Leucocitos , Recuento de Leucocitos
13.
Neural Netw ; 169: 282-292, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37918271

RESUMEN

Existing methods for estimating human poses from video content exploit the temporal features of the video sequences and have shown impressive results. However, most methods address spatiotemporal issues separately. They compromise on accuracy to reduce jitter, or require high-resolution images to deal with occlusion, preventing full consideration of temporal features. Unfortunately, these two issues are interrelated. For example, occlusion causes uncertainty between successive frames, leading to unsmoothed results. To address these issues, we propose the Masked Kinematic Continuity-aware Hierarchical Attention Network (M-HANet) as a novel framework that exploits masked kinematic keypoint features by extending our framework HANet framework. First, we randomly select and mask a keypoint to treat the masked keypoint as it is occluded, which allows us to make the network resilient to occlusion. We also use the velocity and acceleration of each individual keypoint to effectively capture temporal features. Second, the proposed hierarchical transformer encoder refines a 2D or 3D input pose derived from existing estimators by aggregating the masked continuity of the spatiotemporal dependencies of human motion. Finally, to facilitate collaborative optimization, we perform an online cross-supervision between the final pose from our decoder and the refined input pose produced by our encoder. We validate the effectiveness of our model demonstrating that our proposed approach improves PCK@0.05 by 14.1% and MPJPE by 8.7 mm compared to the existing method on a variety of tasks, including 2D and 3D pose estimation, body mesh recovery, and sparsely annotated multi-human pose estimation.


Asunto(s)
Resiliencia Psicológica , Humanos , Fenómenos Biomecánicos , Movimiento (Física) , Incertidumbre
14.
J Yeungnam Med Sci ; 41(1): 53-55, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38146600

RESUMEN

A noncontact sensor field is an innovative device that can detect, measure, or monitor physical properties or conditions without direct physical contact with the subject or object under examination. These sensors use a variety of methods, including electromagnetic, optical, and acoustic technique, to collect information about the target without physical interaction. Noncontact sensors find wide-ranging applications in various fields such as manufacturing, robotics, automobiles, security, environmental monitoring, space industry, agriculture, and entertainment. In particular, they are used in the medical field, where they provide continuous monitoring of patient conditions and offer opportunities in rehabilitation medicine. This article introduces the potential of noncontact sensors in the field of rehabilitation medicine.

15.
Diagn Microbiol Infect Dis ; 108(3): 116164, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38157639

RESUMEN

We evaluated the analytical performance of ID NOW™ COVID-19 2.0 assay versus conventional real-time reverse transcription-polymerase chain reaction (RT-PCR) using a total of 792 clinical samples from nasopharyngeal and oropharyngeal swabs, stored in frozen universal transport medium samples. Positive percent agreement (PPA) and negative percent agreement of ID NOW were 97.6 % and 100 %, respectively. The overall percent agreement between ID NOW and RT-PCR was 99.5 %. The PPA of ID NOW in detecting SARS-CoV-2 in 164 RT-PCR positive patients, all of whom had symptoms related COVID-19, was 97.1 % within 8 days since symptom onset, 97.9 % from 8 to 14 days since symptom onset, and 97.6 % after 14 days since symptom onset, with no significant difference between the days since symptom onset. The ID NOW assay demonstrated good performance, providing a rapid and randomly accessible alternative to conventional RT-PCR for timely SARS-CoV-2 detection, particularly in situations requiring rapid results for patient care.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Prueba de COVID-19 , Técnicas de Laboratorio Clínico/métodos , Sensibilidad y Especificidad , Nasofaringe
16.
J Clin Med ; 12(22)2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-38002668

RESUMEN

We sought to determine whether blade size influences the first-pass success (FPS) rate when performing endotracheal intubation (ETI) with a C-MAC video laryngoscope (VL) in emergency department (ED) patients. This single-center, retrospective, observational study was conducted between August 2016 and July 2022. A total of 1467 patients was divided into two categories based on the blade size used during the first ETI attempt: blade-3 (n = 365) and blade-4 groups (n = 1102). The primary outcome was the FPS rate. The secondary outcomes included the glottic view, multiple attempt rate, and ETI-related complications. We used propensity score matching to reduce the potential confounders between the two groups. Among these, 363 pairs of matched propensity scores were generated. The FPS rate did not differ between the blade-3 (84.8%) and blade-4 groups (87.3%) in the matched cohort (p = 0.335). The multiple attempt rate did not differ significantly between groups (p = 0.289) and was 3.9% and 2.5% in the blade-3 and blade-4 groups, respectively. The difficult glottic view (11.3 vs. 6.9%, p = 0.039) and complication rates (15.4% vs. 10.5%, p = 0.047) were significantly higher in the blade-3 group than in the blade-4 group. The FPS rates of ETI with the blade-3 and blade-4 groups in adult patients in the ED did not differ significantly.

17.
PLoS One ; 18(11): e0294427, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38015931

RESUMEN

Ultraviolet light (UV) acts as a powerful disinfectant and can prevent contamination of personal hygiene from various contaminated environments. The 222-nm wavelength of UV-C has a highly effective sterilization activity and is safer than 275-nm UV-C. We investigated the irradiation efficacy of 222-nm UV-C against contaminating bacteria and viruses in liquid and fabric environments. We conducted colony-forming unit assays to determine the number of viable cells and a 50% tissue culture infectious dose assay to evaluate the virus titration. A minimum dose of 27 mJ/cm2 of 222-nm UV-C was required for >95% germicidal activity for gram-negative and -positive bacteria. A 25.1 mJ/cm2 dose could ensure >95% virucidal activity against low-pathogenic avian influenza virus and severe acute respiratory syndrome coronavirus (SARS-CoV-2). In addition, this energy dose of 222-nm UV-C effectively inactivated SARS-CoV-2 variants, Delta and Omicron. These results provide valuable information on the disinfection efficiency of 222-nm UV-C in bacterial and virus-contaminated environments and can also develop into a powerful tool for individual hygiene.


Asunto(s)
COVID-19 , Enfermedades Transmisibles , Virus , Humanos , SARS-CoV-2 , Rayos Ultravioleta , COVID-19/prevención & control , Virus/efectos de la radiación , Bacterias/efectos de la radiación , Desinfección/métodos
18.
Biochem Genet ; 2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-38017286

RESUMEN

Researchers are increasingly interested in cell therapy using mesenchymal stem cells (MSCs) as an alternative remedy for osteoporosis, with fewer side effects. Thus, we isolated and characterized extracellular vesicles (EVs) from human adipose tissue-derived MSCs (hMSCs) and investigated their inhibitory effects on RANKL-induced osteoclast differentiation. Purified EVs were collected from the supernatant of hMSCs by tangential flow filtration. Characterization of EVs included typical evaluation of the size and concentration of EVs by nanoparticle tracking analysis and morphology analysis using transmission electron microscopy. hMSC-EVs inhibited RANKL-induced differentiation of bone marrow-derived macrophages (BMDMs) into osteoclasts in a dose-dependent manner. F-actin ring formation and bone resorption were also reduced by EV treatment of osteoclasts. In addition, EVs decreased RANKL-induced phosphorylation of p38 and JNK and expression of osteoclastogenesis-related genes in BMDMs treated with RANKL. To elucidate which part of the hMSC-EVs plays a role in the inhibition of osteoclast differentiation, we analyzed miRNA profiles in hMSC-EVs. The results showed that has-miR122-5p was present at significantly high read counts. Overexpression of miR122-5p in BMDMs significantly inhibited RANKL-induced osteoclast differentiation and induced defects in F-actin ring formation and bone resorption. Our results also revealed that RANKL-induced phosphorylation of p38 and JNK and osteoclast-specific gene expression was decreased by miR122-5p transfection, which was consistent with the results of hMSC-EVs. These findings suggest that hMSC-EVs containing miR122-5p inhibit RANKL-induced osteoclast differentiation via the downregulation of molecular mechanisms and could be a preventive candidate for destructive bone diseases.

20.
J Clin Med ; 12(19)2023 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-37835046

RESUMEN

We investigated the prognostic performance of scoring systems by the intensive care unit (ICU) type. This was a retrospective observational study using data from the Marketplace for Medical Information in the Intensive Care IV database. The primary outcome was in-hospital mortality. We obtained Sequential Organ Failure Assessment (SOFA), Acute Physiology and Chronic Health Evaluation (APACHE) III, and Simplified Acute Physiology Score (SAPS) II scores in each ICU type. Prognostic performance was evaluated with the area under the receiver operating characteristic curve (AUROC) and was compared among ICU types. A total of 29,618 patients were analyzed, and the in-hospital mortality was 12.4%. The overall prognostic performance of APACHE III was significantly higher than those of SOFA and SAPS II (0.807, [95% confidence interval, 0.799-0.814], 0.785 [0.773-0.797], and 0.795 [0.787-0.811], respectively). The prognostic performance of SOFA, APACHE III, and SAPS II scores was significantly different between ICU types. The AUROC ranges of SOFA, APACHE III, and SAPS II were 0.723-0.826, 0.728-0.860, and 0.759-0.819, respectively. The neurosurgical and surgical ICUs had lower prognostic performance than other ICU types. The prognostic performance of scoring systems in patients with suspected infection is significantly different according to ICU type. APACHE III systems have the highest prediction performance. ICU type may be a significant factor in the prognostication.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...