Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Eye (Lond) ; 28(1): 47-52, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24136571

RESUMEN

PURPOSE: To investigate the changes in endothelial cell count, central corneal thickness (CCT), and refractive error after a session of selective laser trabeculoplasty (SLT) for open angle glaucoma (OAG). METHODS: This prospective cohort study recruited 111 eyes of 66 consecutive subjects with OAG. Subjects received SLT to 360° of the trabecular meshwork. Endothelial cell count, CCT, and spherical equivalent were measured at baseline before SLT as well as at 1 week and 1 month post SLT. A repeated measure nested ANOVA with Tukey's multiple comparison test was performed to compare the outcome measures before and after SLT. RESULTS: In 111 eyes of 66 subjects, the mean number of laser applications per treatment was 166.9 ± 41.4 with a mean energy level of 1.0 ± 0.07 mJ. The mean endothelial cell count decreased significantly from 2465.0 ± 334.0 cells/mm(2) at baseline to 2355.0 ± 387.0 cells/mm(2) at 1 week (P=0.0004) but increased to baseline levels at 1 month post SLT (2424.0 ± 379.4 cells/mm(2), P=0.3). The CCT, which decreased from a baseline of 549.4 ± 37.6 to 543.9 ± 40.2 µm at 1 week post SLT (P=0.02), also returned to the baseline level by 1 month (P=0.2). The spherical equivalent was static from baseline. A positive correlation was found between total laser energy and CCT at 1 month post treatment (r=0.3, P=0.005). CONCLUSION: The transient reductions in endothelial cell count and CCT following SLT returned to baseline levels 1 month after the procedure. Patients undergoing SLT should be aware of the risk of potential corneal changes.


Asunto(s)
Pérdida de Celulas Endoteliales de la Córnea/etiología , Endotelio Corneal/patología , Glaucoma de Ángulo Abierto/cirugía , Terapia por Láser/efectos adversos , Malla Trabecular/cirugía , Trabeculectomía/efectos adversos , Recuento de Células , Estudios de Cohortes , Pérdida de Celulas Endoteliales de la Córnea/fisiopatología , Paquimetría Corneal , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tomografía de Coherencia Óptica , Malla Trabecular/fisiopatología , Agudeza Visual/fisiología
3.
Eye (Lond) ; 24(11): 1675-80, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20689570

RESUMEN

PURPOSE: To analyse the long-term visual acuity (VA) and intraocular pressure (IOP) outcomes in phacomorphic glaucoma. PATIENTS AND METHODS: A retrospective analysis of 100 consecutive, acute phacomorphic glaucoma cases from January 2000 to April 2009 was conducted at The Caritas Medical Centre in Hong Kong. All cases underwent cataract extraction after IOP control with medication and/or laser. RESULTS: During a 3.1±2.6-year follow-up, the mean visual improvement was 1.1±0.9 LogMAR units with improvements in 81.7% of cases. A shorter duration from symptoms to cataract extraction resulted in greater visual improvement (r(2)=0.1, P=0.001). In all, 80.5% of the cases had IOP≤21 mm Hg without any glaucoma treatment; 19.5% required 1.6±0.7 glaucoma eye drops; and 3.7% required additional laser iridotomy or trabeculectomy for IOP control at 1.8±2.3 years. The vertical cup-disc ratio (VCDR) of the index eye was 0.6±0.3. Gonioscopy revealed an averaged Shaffer grading of 3.0±1.0 and 99±90 degrees of peripheral anterior synechiae (PAS). The Humphrey automated perimetry mean deviation was 5.2±2.7 and the pattern standard deviation was -15.9±10. CONCLUSION: Over 80% of phacomorphic patients had long-term visual improvements and normalization of IOP after cataract extraction. A shorter attack seemed to offer better VA. Post-operatively, most have open angles with some degree of PAS formation, and glaucomatous optic neuropathy is evident from enlarged VCDRs and visual field defects. At least 2 years of follow-up is useful to detect a 20% glaucoma progression possibly requiring additional glaucoma treatments.


Asunto(s)
Extracción de Catarata , Glaucoma de Ángulo Abierto/fisiopatología , Presión Intraocular/fisiología , Agudeza Visual/fisiología , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Glaucoma de Ángulo Abierto/terapia , Hong Kong , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tonometría Ocular , Campos Visuales/fisiología
4.
J Med Imaging Radiat Oncol ; 52(3): 254-61, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18477120

RESUMEN

The objective of the current study was to evaluate the effect of PET on the management of primary tumours of the thymus. Patients with a primary tumour of the thymus who underwent PET were identified from a prospective database. Forty-three PET scans were carried out on 26 patients with primary thymic tumours. Sensitivity, specificity and accuracy were 79, 100 and 85%, respectively. Conventional imaging and PET findings were discordant in 10 cases (23%). PET appropriately changed patient management in three (7.0%) cases based on accurate results that differed from pre-PET imaging. Most PET scans carried out (88%) did not influence clinical management. Patient comorbidities, limited treatment options and already planned surgery are factors that may hinder the effect of PET in the setting of thymic tumours. The potential for false-negative results, probably because of a combination of low-fluorodeoxyglucose avidity and small volume residual disease, needs to be considered in management planning. However, the positive predictive value of PET is high and enables appropriate modification of management in a small, but potentially important subset of patients.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Neoplasias del Timo/diagnóstico por imagen , Neoplasias del Timo/terapia , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad , Pronóstico , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA