Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Heart Rhythm ; 19(3): 443-447, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34767989

RESUMEN

BACKGROUND: Implantable loop recorders (ILRs) are effective in achieving symptom-rhythm correlation. Data on the diagnostic yield of ILRs, on nurse-led syncope clinics, and on nurse-led ILR implants are limited. OBJECTIVE: We evaluated the safety and efficacy of our nurse-led syncope clinic and nurse-led ILR implants. METHODS: A retrospective study of all consecutive patients undergoing nurse-led ILR implantations was performed between April 2016 and April 2018. Patients were referred from both nurse-led and physician-led clinics. Data were collected on baseline demographic characteristics, referral source, symptom-rhythm correlation, ILR findings, and subsequent changes to management. All ILRs were enrolled into remote monitoring with automatic arrhythmia detection, and all immediate (≤24 hours) ILR implant complications were recorded. Comparisons were made between nurse-led and physician-led clinics and subsequent outcomes. RESULTS: A total of 432 patients with an ILR were identified: 164 (38%) from nurse-led and 268 (62%) from physician-led clinics; 200 (46%) were women (mean age 66.5 ± 18.2 years; mean follow-up duration 28.9 ± 9.5 months). Primary ILR indications were syncope (n = 251 [58%]), presyncope (n = 33 [7%]), palpitation (n = 39 [9%]), cryptogenic stroke (n = 78 [18%]), and other reasons (n = 31 [7%]). No immediate ILR implant complications occurred. Overall, 156 patients (36%) had a change in management as a direct result of ILR findings, with no overall differences between nurse-led and physician-led clinics (35% vs 36%; P = .7). More patients had newly diagnosed atrial fibrillation in physician-led clinics (15% vs 7%; P = .01), and more patients had pacemaker implants for bradycardia in nurse-led clinics (23% vs 13%; P < .01). CONCLUSION: Nurse-led ILR implantation was safe and effective. Nurse-led syncope clinics achieved good symptom-rhythm correlation with resultant significant changes to management in comparison to physician-led clinics. Larger prospective studies are needed to evaluate their longer-term impact.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Electrocardiografía Ambulatoria/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rol de la Enfermera , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Síncope/diagnóstico , Síncope/etiología , Síncope/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...