Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
PNAS Nexus ; 3(5): pgae156, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38715730

RESUMEN

The increasing need for precise dietary monitoring across various health scenarios has led to innovations in wearable sensing technologies. However, continuously tracking food and fluid intake during daily activities can be complex. In this study, we present a machine-learning-powered smart neckband that features wireless connectivity and a comfortable, foldable design. Initially considered beneficial for managing conditions such as diabetes and obesity by facilitating dietary control, the device's utility extends beyond these applications. It has proved to be valuable for sports enthusiasts, individuals focused on diet control, and general health monitoring. Its wireless connectivity, ergonomic design, and advanced classification capabilities offer a promising solution for overcoming the limitations of traditional dietary tracking methods, highlighting its potential in personalized healthcare and wellness strategies.

2.
ACS Appl Mater Interfaces ; 16(20): 26613-26623, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38728055

RESUMEN

Strain gauges, particularly for wearable sensing applications, require a high degree of stretchability, softness, sensitivity, selectivity, and linearity. They must also steer clear of challenges such as mechanical and electrical hysteresis, overshoot behavior, and slow response/recovery times. However, current strain gauges face challenges in satisfying all of these requirements at once due to the inevitable trade-offs between these properties. Here, we present an innovative method for creating strain gauges from spongy Ag foam through a steam-etching process. This method simplifies the traditional, more complex, and costly manufacturing techniques, presenting an eco-friendly alternative. Uniquely, the strain gauges crafted from this method achieve an unparalleled gauge factor greater than 8 × 103 at strains exceeding 100%, successfully meeting all required attributes without notable trade-offs. Our work includes systematic investigations that reveal the intricate structure-property-performance relationship of the spongy Ag foam with practical demonstrations in areas such as human motion monitoring and human-robot interaction. These breakthroughs pave the way for highly sensitive and selective strain gauges, showing immediate applicability across a wide range of wearable sensing applications.

3.
ACS Sens ; 9(2): 662-673, 2024 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-38300847

RESUMEN

Self-healing hydrogels are in high demand for wearable sensing applications due to their remarkable deformability, high ionic and electrical conductivity, self-adhesiveness to human skin, as well as resilience to both mechanical and electrical damage. However, these hydrogels face challenges such as delayed healing times and unavoidable electrical hysteresis, which limit their practical effectiveness. Here, we introduce a self-healing hydrogel that exhibits exceptionally rapid healing with a recovery time of less than 0.12 s and an ultralow electrical hysteresis of less than 0.64% under cyclic strains of up to 500%. This hydrogel strikes an ideal balance, without notable trade-offs, between properties such as softness, deformability, ionic and electrical conductivity, self-adhesiveness, response and recovery times, durability, overshoot behavior, and resistance to nonaxial deformations such as twisting, bending, and pressing. Owing to this unique combination of features, the hydrogel is highly suitable for long-term, durable use in wearable sensing applications, including monitoring body movements and electrophysiological activities on the skin.


Asunto(s)
Hidrogeles , Dispositivos Electrónicos Vestibles , Humanos , Electricidad , Conductividad Eléctrica , Movimiento
4.
Biosens Bioelectron ; 246: 115882, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38043302

RESUMEN

Hydrolase-mimicking nanozymes have received increasing attention in recent years, but the effective rational design and development of these materials has not been realized, as they are not at present considered a critical research target. Herein, we report that Zn-doped mesoporous ceria (Zn-m-ceria) engineered to have an abundance of two different active sites with different functions-one that allows both co-adsorption binding of organophosphate (OP) and water and another that serves as a general base-has significant organophosphorus hydrolase (OPH)-like catalytic activity. Specifically, Zn-m-ceria exhibits a catalytic efficiency over 75- and 25-fold higher than those of m-ceria and natural OPH, respectively. First-principles calculations reveal the importance of Zn for the OPH-mimicking activity of the material, promoting substrate adsorption and proton-binding. The OPH-like Zn-m-ceria catalyst is successfully applied to detect a model OP, methyl paraoxon, in spiked tap water samples with excellent sensitivity, stability, and detection precision. We expect that these findings will promote research based on the rational engineering of the active site of nanozymes and efficient strategies for obtaining a diverse range of catalysts that mimic natural enzymes, and hence the utilization in real-world applications of enzyme-mimicking catalysts with properties superior to their natural analogs should follow.


Asunto(s)
Arildialquilfosfatasa , Técnicas Biosensibles , Arildialquilfosfatasa/química , Dominio Catalítico , Organofosfatos , Agua , Zinc
5.
ACS Nano ; 17(24): 25014-25026, 2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38059775

RESUMEN

Vertically ordered Si needles are of particular interest for long-term intracellular recording owing to their capacity to infiltrate living cells with negligible damage and minimal toxicity. Such intracellular recordings could greatly benefit from simultaneous live cell imaging without disrupting their culture, contributing to an in-depth understanding of cellular function and activity. However, the use of standard live imaging techniques, such as inverted and confocal microscopy, is currently impeded by the opacity of Si wafers, typically employed for fabricating vertical Si needles. Here, we introduce a transparent intracellular sensing platform that combines vertical Si needles with a percolated network of Au-Ag nanowires on a transparent elastomeric substrate. This sensing platform meets all prerequisites for simultaneous intracellular recording and imaging, including electrochemical impedance, optical transparency, mechanical compliance, and cell viability. Proof-of-concept demonstrations of this sensing platform include monitoring electrical potentials in cardiomyocyte cells and in three-dimensionally engineered cardiovascular tissue, all while conducting live imaging with inverted and confocal microscopes. This sensing platform holds wide-ranging potential applications for intracellular research across various disciplines such as neuroscience, cardiology, muscle physiology, and drug screening.


Asunto(s)
Microscopía , Nanocables , Supervivencia Celular , Miocitos Cardíacos , Agujas
6.
Artículo en Inglés | MEDLINE | ID: mdl-38041570

RESUMEN

Continuous real-time monitoring of biomarkers in interstitial fluid is essential for tracking metabolic changes and facilitating the early detection and management of chronic diseases such as diabetes. However, developing minimally invasive sensors for the in situ analysis of interstitial fluid and addressing signal delays remain a challenge. Here, we introduce a wearable sensor patch incorporating hydrogel microneedles for rapid, minimally invasive collection of interstitial fluid from the skin while simultaneously measuring biomarker levels in situ. The sensor patch is stretchable to accommodate the swelling of the hydrogel microneedles upon extracting interstitial fluid and adapts to skin deformation during measurements, ensuring consistent sensing performance in detecting model biomarker concentrations, such as glucose and lactate, in a mouse model. The sensor patch exhibits in vitro sensitivities of 0.024 ± 0.002 µA mM-1 for glucose and 0.0030 ± 0.0004 µA mM-1 for lactate, with corresponding linear ranges of 0.1-3 and 0.1-12 mM, respectively. For in vivo glucose sensing, the sensor patch demonstrates a sensitivity of 0.020 ± 0.001 µA mM-1 and a detection range of 1-8 mM. By integrating a predictive model, the sensor patch can analyze and compensate for signal delays, improving calibration reliability and providing guidance for potential optimization in sensing performance. The sensor patch is expected to serve as a minimally invasive platform for the in situ analysis of multiple biomarkers in interstitial fluid, offering a promising solution for continuous health monitoring and disease management.

7.
ACS Nano ; 17(22): 22733-22743, 2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-37933955

RESUMEN

E-textiles, also known as electronic textiles, seamlessly merge wearable technology with fabrics, offering comfort and unobtrusiveness and establishing a crucial role in health monitoring systems. In this field, the integration of custom sensor designs with conductive polymers into various fabric types, especially in large areas, has presented significant challenges. Here, we present an innovative additive patterning method that utilizes a dual-regime spray system, eliminating the need for masks and allowing for the programmable inscription of sensor arrays onto consumer textiles. Unlike traditional spray techniques, this approach enables in situ, on-the-fly polymerization of conductive polymers, enabling intricate designs with submillimeter resolution across fabric areas spanning several meters. Moreover, it addresses the nozzle clogging issues commonly encountered in such applications. The resulting e-textiles preserve essential fabric characteristics such as breathability, wearability, and washability while delivering exceptional sensing performance. A comprehensive investigation, combining experimental, computational, and theoretical approaches, was conducted to examine the critical factors influencing the operation of the dual-regime spraying system and its role in e-textile fabrication. These findings provide a flexible solution for producing e-textiles on consumer fabric items and hold significant implications for a diverse range of wearable sensing applications.

8.
Dalton Trans ; 52(37): 13269-13277, 2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37668062

RESUMEN

In this study, we present a colloidal assembly of histidyl bolaamphiphiles whose imidazoles coordinate with rhodium ions (HisC7[Rh]) to exhibit catalytic isomerization activity for cis-stilbene and cis-alkene molecules. The histidyl bolaamphiphiles self-assemble to form a soft scaffold that functions analogously to an apoenzyme. This scaffold exposes multiple histidyl imidazoles and carboxylates on its surface, to which rhodium ions bind, generating catalytically active sites. The Rh coordination with the biochemical functional groups was verified through comprehensive vibrational spectroscopy and calorimetry. The colloidal HisC7[Rh] demonstrated a significant catalytic effect on the isomerization of cis- to trans-stilbene under mild H2 conditions, resulting in 69% yield of trans-stilbene. In contrast, when Rh(cod)2BF4 was employed as a control catalyst, only the hydrogenated products of bibenzyl were obtained. These findings underscore the crucial role of histidyl motifs in exhibiting unique catalytic isomerization activity through the coordination with Rh. The catalytic activity of HisC7[Rh] is governed by several factors, such as rhodium content, solvent composition, temperature, and H2 pressure. Moreover, HisC7[Rh] displayed moderate isomerization activity towards not only stilbene but also unsaturated fatty acid isomers, highlighting its expansive potential as an isomerization catalyst.

9.
Micromachines (Basel) ; 12(7)2021 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-34199036

RESUMEN

Polymers with the shape memory effect possess tremendous potential for application in diverse fields, including aerospace, textiles, robotics, and biomedicine, because of their mechanical properties (softness and flexibility) and chemical tunability. Biodegradable shape memory polymers (BSMPs) have unique benefits of long-term biocompatibility and formation of zero-waste byproducts as the final degradable products are resorbed or absorbed via metabolism or enzyme digestion processes. In addition to their application toward the prevention of biofilm formation or internal tissue damage caused by permanent implant materials and the subsequent need for secondary surgery, which causes secondary infections and complications, BSMPs have been highlighted for minimally invasive medical applications. The properties of BSMPs, including high tunability, thermomechanical properties, shape memory performance, and degradation rate, can be achieved by controlling the combination and content of the comonomer and crystallinity. In addition, the biodegradable chemistry and kinetics of BSMPs, which can be controlled by combining several biodegradable polymers with different hydrolysis chemistry products, such as anhydrides, esters, and carbonates, strongly affect the hydrolytic activity and erosion property. A wide range of applications including self-expending stents, wound closure, drug release systems, and tissue repair, suggests that the BSMPs can be applied as actuators on the basis of their shape recovery and degradation ability.

10.
Cancers (Basel) ; 13(14)2021 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-34298685

RESUMEN

Since triple-negative breast cancers (TNBCs) have varying prognoses, it is important to identify subgroups with particularly poor prognosis. The aim of this study was to assess whether changes in the neutrophil-to-lymphocyte ratio (NLR) during the treatment process were associated with poor prognosis in TNBC patients. This study included 600 TNBC patients who underwent surgery from January 2005 to December 2016. The associations of the NLR and clinicopathologic factors with breast cancer recurrence and survival in patients who underwent both definitive local treatment (total mastectomy or breast-conserving surgery with radiotherapy) and systemic chemotherapy were analyzed. The NLRs at four time points (before surgery, before chemotherapy, before radiotherapy, and 1 year after surgery) were assessed. The univariate analysis showed that changes in the NLR before the start of radiotherapy (odds ratio: 1.115, confidence interval: 1.011-1.229) and 1 year after surgery (odds ratio: 1.196, confidence interval: 1.057-1.354) significantly increased the risk of recurrence or death. In multivariate analysis, T stage, N stage, and changes in the NLR were significant factors. A time-sequenced NLR may reflect the prognosis of TNBC patients. A poor prognosis is expected in patients whose NLR increases during treatment compared to the preoperative NLR, and additional treatment is needed.

11.
Materials (Basel) ; 14(8)2021 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-33921901

RESUMEN

HY-80 and HY-100 steels, widely used in constructing large ocean vessels and submarine hulls, contain mixed microstructures of tempered bainite and martensite and provide high tensile strength and toughness. Weld integrity in HY steels has been studied to verify and optimize welding conditions. In this study, the T-joint weld coupons, HY80 and HY100, were fabricated from HY-80 and HY-100 steel plates with a thickness of 30 mm as base metals by submerged-arc welding. Flux-cored arc welding was performed on an additional welding coupon consisting of HY-100 to evaluate the effect of repair welds (HY100RP). Microstructures in the heat-affected zones (HAZ) were thoroughly analyzed by optical observation. Instrumented indentation testing, taking advantage of local characterization, was applied to assess the yield strength and the residual stress of the HAZ and base regions. The maximum hardness over 400 HV was found in the HAZ due to the high volume fraction of untempered martensite microstructure. The yield strength of the weld coupons was evaluated by indentation testing, and the results showed good agreement with the uniaxial tensile test (within 10% range). The three coupons showed similar indentation residual stress profiles on the top and bottom surfaces. The stress distribution of the HY100 coupon was comparable to the results from X-ray diffraction. HY100RP demonstrated increased tensile residual stress compared to the as-welded coupon due to the effect of the repair weld (323 and 103 MPa on the top and bottom surfaces). This study verifies the wide applicability of indentation testing in evaluating yield strength and residual stress.

12.
Sci Rep ; 10(1): 16572, 2020 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-33024129

RESUMEN

Freshwater mussels belonging to the genus Nodularia (Family Unionidae) are known to be widely distributed in East Asia. Although phylogenetic and population genetic studies have been performed for these species, there still remain unresolved questions in their taxonomic status and biogeographic distribution pathways. Here, the nucleotide sequences of CO1 and 16S rRNA were newly determined from 86 N. douglasiae and 83 N. breviconcha individuals collected on the Korean Peninsula. Based on these data, we revealed the following results: (1) N. douglasiae can be divided into the three genetic clades of A (only found in Korean Peninsula), B (widely distributed in East Asia), and C (only found in the west of China and Russia), (2) the clade A is not an independent species but a concrete member of N. douglasiae given the lack of genetic differences between the clades A and B, and (3) N. breviconcha is not a subspecies of N. douglasiae but an independent species apart from N. douglasiae. In addition, we suggested the plausible scenarios of biogeographic distribution events and demographic history of Nodularia species.


Asunto(s)
Genética de Población , Nodularia/genética , Filogenia , ARN Ribosómico 16S/genética , Animales , Secuencia de Bases , Asia Oriental , Nodularia/clasificación , Federación de Rusia , Especificidad de la Especie , Unionidae/genética
13.
Nanoscale ; 12(3): 1419-1424, 2020 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-31909409

RESUMEN

A reagent-free colorimetric detection method using mesoporous cerium oxide with a large pore size trapping an oxidative enzyme has been developed and glucose is sensitively detected with a limit of detection of 10 µM by supporting glucose oxidase on mesoporous cerium oxide.


Asunto(s)
Técnicas Biosensibles , Cerio/química , Glucosa Oxidasa/química , Glucosa/análisis , Colorimetría , Sistemas de Atención de Punto , Porosidad
14.
ACS Nano ; 13(4): 4312-4321, 2019 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-30908007

RESUMEN

The work describes a carbon-based peroxidase mimic, N- and B-codoped reduced graphene oxide (NB-rGO), which shows high peroxidase-like activity without oxidase-like activity and has a catalytic efficiency nearly 1000-fold higher than that of undoped rGO. The high catalytic activity of NB-rGO is explained by density functional theory by calculating Gibbs free energy change during the peroxide decomposition reaction. Acetylcholine and C-reactive protein are successfully quantified with high sensitivity and selectivity, which were comparable to or better than those obtained using natural peroxidase. Furthermore, NB-rGO, which does not have oxidase-like activity, is proven to have higher sensitivity toward acetylcholine than Pt nanoparticles having oxidase-like activity. This work will facilitate studies on development, theoretical analysis for rational design, and bioassay applications of enzyme mimics based on nanomaterials.


Asunto(s)
Acetilcolina/sangre , Proteína C-Reactiva/análisis , Grafito/química , Nanoestructuras/química , Peroxidasa/química , Acetilcolina/análisis , Materiales Biomiméticos/química , Técnicas Biosensibles/métodos , Catálisis , Humanos , Modelos Moleculares , Oxidación-Reducción , Termodinámica
15.
Biomed Mater Eng ; 30(2): 157-169, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30741664

RESUMEN

BACKGROUND: The conservation of the joint anatomy is an important factor in total knee arthroplasty (TKA). The restoration of the femoral posterior condylar offset (PCO) has been well known to influence the clinical outcome after TKA. OBJECTIVE: The purpose of this study was to determine the mechanism of PCO in finite element models with conservation of subject anatomy and different PCO of ±1, ±2, ±3 mm in posterior direction using posterior cruciate ligament-retaining TKA. METHODS: Using a computational simulation, we investigated the influence of the changes in PCO on the contact stress in the polyethylene (PE) insert and patellar button, on the forces on the collateral and posterior cruciate ligament, and on the quadriceps muscle and patellar tendon forces. The computational simulation loading condition was deep knee bend. RESULTS: The contact stresses on the PE insert increased, whereas those on the patellar button decreased as posterior condylar offset translated to the posterior direction. The forces exerted on the posterior cruciate ligament and collateral ligaments increased as PCO translated to the posterior direction. The translation of PCO in the anterior direction, in an equivalent flexion angle, required a greater quadriceps muscle force. CONCLUSIONS: Translations of the PCO in the posterior and anterior directions resulted in negative effects in the PE insert and ligament, and the quadriceps muscle force, respectively. Our findings suggest that orthopaedic surgeons should be careful with regard to the intraoperative conservation of PCO, because an excessive change in PCO may lead to quadriceps weakness and an increase in posterior cruciate ligament tension.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Ligamentos Colaterales/anatomía & histología , Análisis de Elementos Finitos , Articulación de la Rodilla/anatomía & histología , Modelos Anatómicos , Fenómenos Biomecánicos , Ligamentos Colaterales/fisiología , Simulación por Computador , Humanos , Articulación de la Rodilla/fisiología , Prótesis de la Rodilla , Modelos Biológicos , Rango del Movimiento Articular
16.
Knee ; 26(1): 250-257, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30577956

RESUMEN

BACKGROUND: The effect of the changes in the femoral posterior condylar offset (PCO) on anterior-posterior (AP) translation and internal-external (IE) rotation in cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA) remains unknown. The purpose of this study was to compare the kinematics in CR and PS TKA with respect to the difference in prosthetic design and PCO change through a computational simulation. METHODS: We developed three-dimensional finite element models with the different PCOs of ±1, ±2 and ±3 mm in the posterior direction using CR and PS TKA. We performed the simulation with different PCOs under a deep knee bend condition and evaluated the kinematics for the AP and IE in CR and PS TKA. RESULTS: The more tibiofemoral (TF) translation in the posterior direction was found as PCO translated in posterior direction for both CR and PS TKA compared to the neutral position. However, the change of the AP translation with respect to the PCO change in CR TKA was greater than PS TKA. The more TF external rotation was found as PCO translated in the anterior direction for both CR and PS TKA compared to the neutral position. However, unlike the TF translation, the TF rotation was not influenced by the PCO change in both CR and PS TKA. CONCLUSION: The PCO magnitude was influenced by a postoperative change in the kinematics in CR TKA although a relatively smaller effect was observed in PS TKA. Hence, surgeons should be aware of the PCO change, especially for CR TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Simulación por Computador , Fémur/fisiopatología , Imagenología Tridimensional , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular/fisiología , Adulto , Fenómenos Biomecánicos , Fémur/diagnóstico por imagen , Fémur/cirugía , Análisis de Elementos Finitos , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Imagen por Resonancia Magnética , Masculino , Periodo Posoperatorio , Diseño de Prótesis , Tomografía Computarizada por Rayos X
17.
J Dent Anesth Pain Med ; 18(5): 305-308, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30402551

RESUMEN

An 87-year-old woman was referred for the extraction of residual teeth and removal of tori prior to prosthetic treatment. After surgery under general anesthesia, the surgical tape was removed to detach the bispectral index sensor and the hair cover. After the surgical tape was removed, skin injury occurred on the left side of her face. After epidermis repositioning and ointment application, a dressing was placed over the injury. Her wound was found to have healed completely on follow-up examination. Medical adhesive related skin injury (MARSI) is a complication that can occur after surgery and subjects at the extremes of age with fragile skin are at a higher risk for such injuries. Careful assessment of the risk factors associated with MARSI is an absolute necessity.

18.
J Environ Health Sci Eng ; 16(1): 19-25, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30258639

RESUMEN

BACKGROUND: Volatile fatty acids (VFA) often accumulate in anaerobic digestion systems, decreasing pH levels and causing unstable operational performance and poor biogas production. The aim of this study is to improve anaerobic digestion efficiency by controlling/reducing the accumulation of VFAs in a continuous anaerobic digestion system. METHODS: NO3 --N was added to the digester and its effects on VFAs were investigated. When the system reached an unstable condition with the accumulation of VFAs, the digester was fed at an organic loading rate of 6 kg COD (chemical oxygen demand)/m3∙d and 0.5Q of aeration tank effluent (1500 mg/L of NO3 --N) was recirculated. RESULTS: With the addition of NO3 --N, VFAs were utilized during denitrification, after which methane production started. Furthermore, the accumulated VFAs could be used as a carbon substrate by denitrifying bacteria. After 56 d, a normal VFA concentration could be achieved. Methane production was 0.02-0.03 L CH4/g VS higher with NO3 --N recirculation and feeding than that without feeding. CONCLUSIONS: The results show that the addition of NO3 --N is a potentially feasible method to control VFAs. Combined with recirculation and feeding, the method can be used to effectively prevent the inhibition of methanogenic microbial activities caused by accumulated VFAs and enhance denitrification and methane production in anaerobic digesters.

19.
Knee ; 25(5): 903-914, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29980426

RESUMEN

BACKGROUND: Postoperative changes of the femoral posterior condylar offset (PCO) and posterior tibial slope (PTS) affect the biomechanics of the knee joint after fixed-bearing total knee arthroplasty (TKA). However, the biomechanics of mobile-bearing is not well known. Therefore, the aim of this study was to investigate whether alterations to the PCO and PTS affect the biomechanics for mobile-bearing TKA. METHODS: We used a computational model for a knee joint that was validated using in vivo experiment data to evaluate the effects of the PCO and PTS on the tibiofemoral (TF) joint kinematics, patellofemoral (PF) contact stress, collateral ligament force and quadriceps force, for mobile-bearing TKA. The computational model was developed using ±1-, ±2- and ±3-mm PCO models in the posterior direction and -3°, 0°, +3°, and +6° PTS models based on each of the PCO models. RESULTS: The maximum PF contact stress, collateral ligament force and quadriceps force decreased as the PTS increased. In addition, the maximum PF contact stress and quadriceps force decreased, and the collateral ligament force increased as PCO translated in the posterior direction. This trend is consistent with that observed in any PCO and PTS. CONCLUSIONS: Our findings show the various effects of postoperative alterations in the PCO and PTS on the biomechanical results of mobile-bearing TKA. Based on the computational simulation, we suggest that orthopaedic surgeons intraoperatively conserve the patient's own anatomical PCO and PTS in mobile-bearing TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Ligamentos Colaterales/diagnóstico por imagen , Simulación por Computador , Fémur/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Músculo Cuádriceps/diagnóstico por imagen , Tibia/diagnóstico por imagen , Ligamentos Colaterales/cirugía , Fémur/cirugía , Humanos , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Músculo Cuádriceps/cirugía , Rango del Movimiento Articular/fisiología , Tibia/cirugía
20.
Biomed Res Int ; 2018: 5139074, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29992149

RESUMEN

Reconstructed posterior tibial slope (PTS) plays a significant role in kinematics restoration after total knee arthroplasty (TKA). However, the effect of increased and decreased PTS on prosthetic type and design has not yet been investigated. We used a finite element model, validated using in vitro data, to evaluate the effect of PTS on knee kinematics in cruciate-retaining (CR) and posterior-stabilized (PS) fixed TKA and rotating platform mobile-bearing TKA. Anterior-posterior tibial translation and internal-external tibial rotation were investigated for PTS ranging from -3° to 15°, with increments of 1°, for three different designs of TKA. Tibial posterior translation and external rotation increased as the PTS increased in both CR and PS TKAs. In addition, there was no remarkable difference in external rotation between CR and PS TKAs. However, for the mobile-bearing TKA, PTS had less effect on the kinematics. Based on our computational simulation, PTS is the critical factor that influences kinematics in TKA, especially in the CR TKA. Therefore, the surgeon should be careful in choosing the PTS in CR TKAs.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/fisiología , Tibia/anatomía & histología , Adulto , Fenómenos Biomecánicos , Humanos , Prótesis de la Rodilla , Masculino , Ligamento Cruzado Posterior , Rango del Movimiento Articular , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA