Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Dent Sci ; 19(2): 919-928, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38618085

RESUMEN

Background/purpose: The chemo-mechanical caries-removal technique is known to offer advantages of selective dentin caries treatment while leaving healthy dental tissues intact. However, current sodium hypochlorite based reagents usually excessively damage dentin collagen. Therefore, the purpose of this study was to develop a novel chemo-mechanical caries-removal system to preserve the collagen network for subsequent prosthetic restorations. Materials and methods: The calfskin-derived collagen was chosen as a model system to investigate the dissolution behavior of collagen under different operating conditions of chemical-ultrasonic treatment systems. The molecular weight, triple-helix structure, the morphology, and functional group of collagen after treatment were investigated. Results: Various concentrations of sodium hypochlorite or zinc chloride together with ultrasonic machinery were chosen to investigate. The outcomes of circular dichroism (CD) spectra demonstrated stability of the triple-helix structure after treatment of a zinc chloride solution. In addition, two apparent bands at molecular weights (MWs) of 130 and 121 kDa evidenced the stability of collagen network. The positive 222 nm and 195 nm negative CD absorption band indicated the existence of a triple-helix structure for type I collagen. The preservation of the morphology and functional group of the collagen network on the etched dentin surface were investigated by in vitro dentin decalcification model. Conclusion: Unlike NaOCl, the 5 wt% zinc chloride solution combined with ultra-sonication showed dissolution rather than denature as well as degradation of the dentin collagen network. Additional in vivo evaluations are needed to verify its usefulness in clinical applications.

2.
J Dent Sci ; 19(2): 1165-1173, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38618118

RESUMEN

BACKGROUND/PURPOSE: The diagnosis of peri-implantitis using periapical radiographs is crucial. Recently, artificial intelligence may apply in radiographic image analysis effectively. The aim of this study was to differentiate the degree of marginal bone loss of an implant, and also to classify the severity of peri-implantitis using a deep learning model. MATERIALS AND METHODS: A dataset of 800 periapical radiographic images were divided into training (n = 600), validation (n = 100), and test (n = 100) datasets with implants used for deep learning. An object detection algorithm (YOLOv7) was used to identify peri-implantitis. The classification performance of this model was evaluated using metrics, including the specificity, precision, recall, and F1 score. RESULTS: Considering the classification performance, the specificity was 100%, precision was 100%, recall was 94.44%, and F1 score was 97.10%. CONCLUSION: Results of this study suggested that implants can be identified from periapical radiographic images using deep learning-based object detection. This identification system could help dentists and patients suffering from implant problems. However, more images of other implant systems are needed to increase the learning performance to apply this system in clinical practice.

3.
J Prosthodont Res ; 68(3): 466-473, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38220161

RESUMEN

PURPOSE: This study aimed to investigate the retentive force and deformation of double Akers' polyetherketoneketone (PEKK) clasps on removable partial dentures (RPDs) with varying designs and undercut depths. METHODS: Thirty double Akers' PEKK clasps with two different widths and heights (Groups I and II) were fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM). Each design was further subdivided (n = 5) into three undercut depths (0.25, 0.50, and 0.75 mm). The retentive force of the clasps was measured after 10 years of clinical use (15,000 insertion/removal cycles), and the deformation of the clasp tips was analyzed before and after cycling. RESULTS: Clasps with 0.50-mm and 0.75-mm undercut depths exhibited greater initial retentive forces (3.15-3.51 N) compared to those in the 0.25-mm undercut group (2.40-2.80 N). Group I maintained consistent retentive forces over the cycles (P = 0.345), whereas Group II showed declining forces after the initial use (P < 0.003). In both groups, the 0.50-mm undercut exhibited a greater retentive force than the 0.25-mm (P < 0.001 and P < 0.004, respectively), with no significant differences between the 0.50-mm and 0.75-mm undercut depths. Despite a lower initial retentive force, the 0.25-mm undercut showed less deformation and clasp tip wear. CONCLUSIONS: The PEKK clasps did not exhibit significantly reduced retentive forces or permanent deformations after 15,000 fatigue cycles. These results suggest that the PEKK polymer displays superior mechanical properties as an esthetic clasp material, and clasps with 0.50-mm and 0.75-mm undercut depths are recommended for long-term clinical use.


Asunto(s)
Diseño Asistido por Computadora , Abrazadera Dental , Diseño de Dentadura , Dentadura Parcial Removible , Cetonas , Diseño de Dentadura/métodos , Polímeros , Retención de Dentadura , Benzofenonas , Ensayo de Materiales , Técnicas In Vitro , Análisis del Estrés Dental
4.
J Prosthet Dent ; 131(2): 291.e1-291.e9, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38057199

RESUMEN

STATEMENT OF PROBLEM: The retentive force and deformation of milled polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) removable partial denture (RPD) frameworks are not well understood. PURPOSE: The purpose of this in vitro study was to assess the retentive force and deformation of PEEK and PEKK Akers clasps with different designs and undercut depths. MATERIAL AND METHODS: A master model containing the first and second molar abutments was used to design Akers clasps of different cross-sectional dimensions, undercut depths (0.5 and 0.75 mm), and materials. The components of the removable partial denture framework also included an occlusal rest and were manufactured using a milling machine (n=5). The fatigue resistance of the Akers clasps was measured before and after deformation regarding the retentive forces. RESULTS: The PEEK2-U50 clasp had the largest retentive force with no significant difference among all groups before and after the insertion and removal cycle. In addition, the increased cross-sectional dimensions of the design resulted in significant differences in retentive forces between the PEEK1 and PEEK2 groups and between the PEEK and PEKK materials. CONCLUSIONS: Increasing the clasp's cross-sectional dimensions significantly impacted retentive forces, especially between different PEEK groups and between PEEK and PEKK materials.


Asunto(s)
Benzofenonas , Aleaciones de Cromo , Dentadura Parcial Removible , Polímeros , Estudios Transversales , Retención de Dentadura , Polietilenglicoles , Cetonas , Abrazadera Dental
5.
Polymers (Basel) ; 15(6)2023 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-36987176

RESUMEN

Manufacturing three-dimensional (3D) objects with polymers/bioceramic composite materials has been investigated in recent years. In this study, we manufactured and evaluated solvent-free polycaprolactone (PCL) and beta-tricalcium phosphate (ß-TCP) composite fiber as a scaffold material for 3D printing. To investigate the optimal ratio of feedstock material for 3D printing, the physical and biological characteristics of four different ratios of ß-TCP compounds mixed with PCL were investigated. PCL/ß-TCP ratios of 0 wt.%, 10 wt.%, 20 wt.%, and 30 wt.% were fabricated, with PCL melted at 65 °C and blended with ß-TCP with no solvent added during the fabrication process. Electron microscopy revealed an even distribution of ß-TCP in the PCL fibers, while Fourier transform infrared spectroscopy demonstrated that the biomaterial compounds remained intact after the heating and manufacturing process. In addition, adding 20% ß-TCP into the PCL/ß-TCP mixture significantly increased hardness and Young's Modulus by 10% and 26.5%, respectively, suggesting that PCL-20 has better resistance to deformation under load. Cell viability, alkaline phosphatase (ALPase) activity, osteogenic gene expression, and mineralization were also observed to increase according to the amount of ß-TCP added. Cell viability and ALPase activity were 20% higher with PCL-30, while upregulation for osteoblast-related gene expression was better with PCL-20. In conclusion, PCL-20 and PCL-30 fibers fabricated without solvent exhibited excellent mechanical properties, high biocompatibility, and high osteogenic ability, making them promising materials for 3D printing customized bone scaffolds promptly, sustainably, and cost-effectively.

6.
Clin Oral Investig ; 27(1): 165-171, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36125622

RESUMEN

OBJECTIVES: There is insufficient information about the effects of the thickness of externally characterized stains or glazes on CIELAB color parameters and the translucency parameter (TP) of 5 mol% yttria partially stabilized zirconia (5Y-PSZ). The present study evaluated the effect of a thickness reduction of the externally characterized or glazed layer on its CIE2000 color parameters and TP00 of 5Y-PSZ. MATERIALS AND METHODS: Twenty-eight specimens were sectioned from 5Y-PSZ blanks. Three brands of powdered stains (namely VI, SH, and IV) and a glaze (GL) were used to extrinsically stain the specimen surfaces (n = 7 per group). After measuring the final thickness and color, specimens of each group were carefully ground and finally polished. The reduced thickness was carefully controlled in decrements of 0.02 mm on the characterized stains or glazed layers at each reduction cycle until the surface of the un-stained zirconia was exposed. The CIELAB color parameters of specimens were measured using a spectrophotometer. Subsequently, differences in lightness (∆L'), chroma (∆C'), and hue (∆H'), and TP00 values and color differences (ΔE00) were calculated using the CIEDE2000 formula to determine differences between the specimen and the un-stained zirconia at each reduction cycle. A paired-samples t-test, two-way mixed-design analysis of variance, and Pearson correlation coefficient were used to analyze the data (α = 0.05). RESULTS: There were no significant differences in lightness, chroma, hue, or TP00 values before or after glazing or after each reduction cycle of the glazed layer. Mean ΔE00 values ranged between 20.94 and 33.55 after applying the externally characterized stains. With a decreased thickness of the characterized stain layer, there were observed that significant decreases in ∆L', ∆H', ∆C', and ΔE00, and significant increases in TP00. CONCLUSIONS: Increasing the thickness of externally characterized stains decreased the lightness and caused the alternation of chroma and hue, whereas these phenomena were not observed in the glazed group. There was a slight change of CIE2000 color parameters and TP00 when the thickness of the characterized layer exceeded 0.06 mm. CLINICAL RELEVANCE: The application and thickness of externally characterized stains can sensitively affect CIE2000 color parameters and translucency of 5Y-PSZ.


Asunto(s)
Colorantes , Circonio , Ensayo de Materiales , Coloración y Etiquetado , Propiedades de Superficie , Cerámica , Color , Porcelana Dental
7.
Polymers (Basel) ; 14(18)2022 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-36146038

RESUMEN

The aim of this study was to evaluate the effects of at-home and in-office bleaching agents on esthetic CAD-CAM materials after red wine immersion by measuring their optical properties. Sixty specimens were prepared out of three esthetic CAD-CAM materials: Vita Enamic, Celtra Duo, and Ceresmart (n = 20). All specimens were immersed in a red wine solution, and color measurements were performed. Specimens were randomly divided (n = 10) according to the bleaching procedure (in office, at home), bleaching durations were set to 3 time points, and color measurements were performed. According to the Commission Internationale de l'Eclairage (CIE) L* a* b* parameters, CIEDE2000 color differences (ΔE00), translucency parameters (TP00), and whiteness index values (ΔWID) after wine staining and after bleaching were calculated. Data were analyzed using the Mann−Whitney U-test, the Kruskal−Wallis test, and a two-way analysis of variance (ANOVA) (α = 0.05). ΔE00, ΔTP00, and ΔWID decreased with an increase in bleaching treatment. ΔE00 after the final bleaching treatment of in-office bleaching ranged from 1.7 to 2.0, whereas those of in-office treatment ranged from 0.4 to 1.1. All ΔTP00 and ΔWID after the final treatment were below the 50:50% perceptibility thresholds (ΔTP00 < 0.6, and ΔWID < 0.7). Significant differences in ΔE00, ΔTP00, and ΔWID among esthetic CAD-CAM materials were found between CD and CE. In the present study, color recovery after at-home and in-office bleaching appeared to be material-dependent. In-office bleaching showed more effective recovery comparing to at-home bleaching.

8.
Polymers (Basel) ; 14(14)2022 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-35890681

RESUMEN

Polyetherketoneketone (PEKK) is an alternative material for use in removable partial denture frameworks; these frameworks must exhibit antibacterial properties to reduce the risk of periodontal disease. In the present study, silver nanoparticles (AgNPs) were synthesized via the reduction of silver nitrate with sodium borohydride in a solution containing polyvinyl pyrrolidone (PVP). Transmission electron microscope images and dynamic light scattering confirmed that metallic nanoparticles had been created with an average size of 32 nm. Furthermore, the coating of the PEKK polymeric substrate with 0.5% AgNPs was carried out using an epoxy resin lining at room temperature. Fourier transform infrared (FTIR) spectra confirmed the successful transfer of the AgNP-in-resin lining onto the polymeric substrate. Scanning electron microscopy and atomic force microscopy confirmed that the AgNPs had been uniformly deposited onto the PEKK specimens. Finally, the antibacterial activity of the specimens was tested against Porphyromonas gingivalis. An inhibition zone of 22.5 mm and an antibacterial rate of 83.47% were found for the PEKK coated with 0.5% AgNPs (0.5% Ag-PEKK) compared to an untreated polyetheretherketone (PEEK) substrate, evidencing that 0.5% Ag-PEKK has potential antibacterial properties for implant applications.

9.
Clin Oral Investig ; 26(3): 3041-3048, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34845525

RESUMEN

OBJECTIVES: The effect of toothbrushing on the color, relative translucency, and surface roughness of extrinsically stained zirconia dental restorations is still unclear. The purpose of the present study was to evaluate the optical properties and surface textures of extrinsically stained or glazed partially stabilized zirconia with 5 mol% yttria (5Y-PSZ) after toothbrushing by determining changes in the color, translucency parameter (TP), and surface roughness. MATERIALS AND METHODS: Specimens (2 mm thick; n = 50) were sectioned from 5Y-PSZ blanks. Three brands of powdered stains (namely VI, SH, IV) and a glaze (GL) were used to extrinsically stain the specimen surfaces (n = 10 per group). The specimens were subjected to 10,000-50,000 simulated toothbrushing strokes using a toothpaste slurry (Ora2 PREMIUM Stain clear paste). The color parameters were measured before staining or glazing and before and after simulated brushing. The color changes and TP values can be calculated before and after simulated brushing. The surface roughness was also evaluated. RESULTS: Significant changes were found in the shade and TP values of 5Y-PSZ after extrinsic staining, but no significant changes were found after toothbrushing, irrespective of the staining brand (p > 0.05). The surface roughness of the characterized 5Y-PSZ specimens decreased after toothbrushing, whereas that of the non-characterized 5Y-PSZ group increased. CONCLUSIONS: Toothbrushing markedly affects the surface roughness of extrinsically stained or glazed 5Y-PSZ specimens, whereas no impacts on the color or translucency were observed. CLINICAL RELEVANCE: For esthetic reasons, clinicians and dental technicians prefer to apply extrinsic stains to zirconia restorations, which profoundly affects its appearance. The limited influence of toothbrushing on color and translucency of 5Y-PSZ is promising for clinical applications.


Asunto(s)
Estética Dental , Cepillado Dental , Cerámica , Porcelana Dental , Ensayo de Materiales , Propiedades de Superficie , Circonio
10.
J Prosthet Dent ; 127(1): 122-127, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33223197

RESUMEN

STATEMENT OF PROBLEM: Although studies have reported on selective laser melting (SLM)-fabricated removable partial dentures (RPDs), research addressing the trueness of SLM-fabricated RPD metal frameworks is sparse. PURPOSE: The purpose of this in vitro study was to evaluate the trueness of powdered cobalt-chromium (Co-Cr) or titanium-6 aluminum-4 vanadium (Ti-6Al-4V) alloy frameworks for RPDs fabricated by SLM. MATERIAL AND METHODS: A digital scan of a Kennedy class II mandible typodont was obtained to design an RPD framework by using a computer-aided design (CAD) software program (denoted as CRF). Two experimental groups of frameworks were fabricated from the CRF by using SLM in alloys of Co-Cr (SLM-Co-Cr, n=6) and in Ti-6Al-4V (SLM-Ti-6Al-4V, n=6) while a control group was fabricated by using traditional lost-wax casting following stereolithography (CA-Co-Cr, n=6). In total, 18 RPD frameworks were digitally scanned (denoted as CRF), with each scan then superimposed on the CRF and evaluated for discrepancies by using a 3D analysis software program. A nonparametric Kruskal-Wallis test was performed to determine differences in trueness among groups (α=.05). RESULTS: The CA-Co-Cr group showed the highest discrepancy between CEF and CRF. Statistically significant differences were found between the CA-Co-Cr and SLM-fabricated groups (P=.03 for Co-Cr, and P=.016 for Ti-6Al-4V). However, no significant difference was found between the SLM-Co-Cr and SLM-Ti-6Al-4V groups (P=.787). CONCLUSIONS: SLM-fabricated RPD frameworks exhibited higher trueness than CA-Co-Cr fabricated ones, indicating the potential of selective laser melting to produce the geometric shapes required for accurate dental restorations.


Asunto(s)
Dentadura Parcial Removible , Aleaciones de Cromo , Diseño Asistido por Computadora , Aleaciones Dentales , Congelación , Rayos Láser , Titanio
11.
J Prosthet Dent ; 127(1): 115-121, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33234303

RESUMEN

STATEMENT OF PROBLEM: The effect of heat treatment on the microstructure and mechanical properties of cobalt-chromium (Co-Cr) removable partial denture (RPD) frameworks fabricated by selective laser melting (SLM) is not well understood. PURPOSE: The purpose of this in vitro study was to evaluate the suitability of SLM-fabricated Co-Cr alloys followed by heat treatment as a framework for RPDs by determining the microstructure and mechanical properties. MATERIAL AND METHODS: Dumbbell specimens and RPD frameworks were fabricated by using SLM followed by heat treatment. The effects of the heat treatment on the microstructure were studied by using optical microscopy, scanning electron microscopy (SEM), and X-ray diffraction (XRD). Tensile and insertion and removal tests were performed to study the mechanical responses of selective laser melting followed by heat treatment specimens, including the ultimate tensile strength (UTS), 0.2% yield strength (0.2% YS), elongation (E), and retentive forces. Specimens fabricated by using the traditional lost-wax process were used as a control (casting) group. RESULTS: X-ray diffraction indicated that the γ-face-centered cubic phase dominated SLM and selective laser melting followed by heat treatment specimens. Results from optical microscopy and SEM showed microstructural changes under different fabrication and postprocessing heat treatments; it was difficult to observe the grain boundary in the SLM group, whereas submicrometer-scale grains had formed in the selective laser melting followed by heat treatment group. The selective laser melting followed by heat treatment group exhibited the highest elongation and retentive forces compared with the casting and SLM groups. CONCLUSIONS: SLM increased the mechanical properties of Co-Cr alloys. Postprocessing heat treatment further enhanced the tensile ductility. It is suggested that SLM followed by heat treatment is an efficient strategy for fabricating RPD frameworks.


Asunto(s)
Dentadura Parcial Removible , Cromo , Aleaciones de Cromo , Cobalto , Calor , Rayos Láser
12.
Polymers (Basel) ; 13(23)2021 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-34883772

RESUMEN

Many revolutionary approaches are on the way pertaining to the high occurrence of tooth decay, which is an enduring challenge in the field of preventive dentistry. However, an ideal dental care material has yet to be fully developed. With this aim, this research reports a dramatic enhancement in the rehardening potential of surface-etched enamels through a plausible synergistic effect of the novel combination of γ-polyglutamic acid (γ-PGA) and nano-hydroxyapatite (nano-HAp) paste, within the limitations of the study. The percentage of recovery of the surface microhardness (SMHR%) and the surface parameters for 9 wt% γ-PGA/nano-HAp paste on acid-etched enamel were investigated with a Vickers microhardness tester and an atomic force microscope, respectively. This in vitro study demonstrates that γ-PGA/nano-HAp treatment could increase the SMHR% of etched enamel to 39.59 ± 6.69% in 30 min. To test the hypothesis of the rehardening mechanism and the preventive effect of the γ-PGA/nano-HAp paste, the surface parameters of mean peak spacing (Rsm) and mean arithmetic surface roughness (Ra) were both measured and compared to the specimens subjected to demineralization and/or remineralization. After the treatment of γ-PGA/nano-HAp on the etched surface, the reduction in Rsm from 999 ± 120 nm to 700 ± 80 nm suggests the possible mechanism of void-filling within a short treatment time of 10 min. Furthermore, ΔRa-I, the roughness change due to etching before remineralization, was 23.15 ± 3.23 nm, while ΔRa-II, the roughness change after remineralization, was 11.99 ± 3.90 nm. This statistically significant reduction in roughness change (p < 0.05) implies a protective effect against the demineralization process. The as-developed novel γ-PGA/nano-HAp paste possesses a high efficacy towards tooth microhardness rehardening, and a protective effect against acid etching.

13.
Polymers (Basel) ; 13(17)2021 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-34502981

RESUMEN

This study evaluated color stability and staining susceptibility of five direct resin-based composites (RBCs) subjected to light-activated in-office bleaching with 40% hydrogen peroxide (HP). The test materials included 5 RBCs, which consisted of one nano-filled, one sub-micron, one bulk-filled, and two nano-hybrid RBC types. Ten disc-shaped specimens of each RBC were fabricated and divided into bleaching (BLE) and non-bleaching (CON) groups (n = 5 for each group). Specimens were then immersed in red wine solution over 4 h. A spectrophotometer was used to obtain Commission Internationale de l'Eclairage (CIE) L*a*b* parameters for each of the following periods tested: before bleaching (TBA), after bleaching (TBL), and after staining (TST). Color stability and staining susceptibility were evaluated using two metrics, CIEDE2000 color differences (ΔE00) and whiteness variations using the whiteness index (ΔWID). Data were analyzed using repeated measures two-way analysis of variance (ANOVA) (α = 0.05). Statistically significant and clinically unaccepted ΔE00 and ΔWID were observed for all tested specimens between TBA and TBL. The nano-hybrid type RBCs showed the highest discoloration among materials after bleaching treatment. The BLE group exhibited significantly higher ΔE00 and ΔWID than the CON group for all the tested RBCs between TBA and TST. The sub-micron type RBC showed the highest discoloration among materials after immersion in the red wine. Conclusion. The light-activated in-office bleaching with 40% HP's influences on color and whiteness index were material-dependent. The use of bleaching treatment also increased the susceptibility to red wine for all RBCs.

14.
Int J Mol Sci ; 22(15)2021 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-34360864

RESUMEN

This study evaluated the new bone formation potential of micro-macro biphasic calcium phosphate (MBCP) and Bio-Oss grafting materials with and without dental pulp-derived mesenchymal stem cells (DPSCs) and bone marrow-derived mesenchymal stem cells (BMSCs) in a rabbit calvarial bone defect model. The surface structure of the grafting materials was evaluated using a scanning electron microscope (SEM). The multipotent differentiation characteristics of the DPSCs and BMSCs were assessed. Four circular bone defects were created in the calvarium of 24 rabbits and randomly allocated to eight experimental groups: empty control, MBCP, MBCP+DPSCs, MBCP+BMSCs, Bio-Oss+DPSCs, Bio-Oss+BMSCs, and autogenous bone. A three-dimensional analysis of the new bone formation was performed using micro-computed tomography (micro-CT) and a histological study after 2, 4, and 8 weeks of healing. Homogenously porous structures were observed in both grafting materials. The BMSCs revealed higher osteogenic differentiation capacities, whereas the DPSCs exhibited higher colony-forming units. The micro-CT and histological analysis findings for the new bone formation were consistent. In general, the empty control showed the lowest bone regeneration capacity throughout the experimental period. By contrast, the percentage of new bone formation was the highest in the autogenous bone group after 2 (39.4% ± 4.7%) and 4 weeks (49.7% ± 1.5%) of healing (p < 0.05). MBCP and Bio-Oss could provide osteoconductive support and prevent the collapse of the defect space for new bone formation. In addition, more osteoblastic cells lining the surface of the newly formed bone and bone grafting materials were observed after incorporating the DPSCs and BMSCs. After 8 weeks of healing, the autogenous bone group (54.9% ± 6.1%) showed a higher percentage of new bone formation than the empty control (35.3% ± 0.5%), MBCP (38.3% ± 6.0%), MBCP+DPSC (39.8% ± 5.7%), Bio-Oss (41.3% ± 3.5%), and Bio-Oss+DPSC (42.1% ± 2.7%) groups. Nevertheless, the percentage of new bone formation did not significantly differ between the MBCP+BMSC (47.2% ± 8.3%) and Bio-Oss+BMSC (51.2% ± 9.9%) groups and the autogenous bone group. Our study results demonstrated that autogenous bone is the gold standard. Both the DPSCs and BMSCs enhanced the osteoconductive capacities of MBCP and Bio-Oss. In addition, the efficiency of the BMSCs combined with MBCP and Bio-Oss was comparable to that of the autogenous bone after 8 weeks of healing. These findings provide effective strategies for the improvement of biomaterials and MSC-based bone tissue regeneration.


Asunto(s)
Regeneración Ósea , Sustitutos de Huesos/uso terapéutico , Anomalías Craneofaciales/cirugía , Minerales/uso terapéutico , Ingeniería de Tejidos/métodos , Andamios del Tejido , Animales , Trasplante Óseo , Masculino , Osteogénesis , Conejos , Cicatrización de Heridas
15.
J Cell Mol Med ; 25(19): 9128-9140, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34427969

RESUMEN

The CXC chemokine ligand-13 (CXCL13) is a chemoattractant of B cells and has been implicated in the progression of many cancers. So far, CXCL13 and its related receptor CXCR5 have been proved to regulate cancer cell migration as well as tumour metastasis. However, the role of CXCL13-CXCR5 axis in metastasis of lung cancer is still poorly understood. In this study, we found that CXCL13 and CXCR5 were commonly up-regulated in lung cancer specimens compared with normal tissues among different cohorts. Our evidence showed that CXCL13 obviously promoted migration of lung cancer cells, and this effect was mediated by vascular cell adhesion molecule-1 (VCAM-1) expression. We also confirmed that CXCR5, the major receptor responsible for CXCL13 function, was required for CXCL13-promoted cell migration. We also test the candidate components which are activated after CXCL13 treatment and found that phospholipase C-ß (PLCß), protein kinase C-α (PKCα) and c-Src signalling pathways were involved in CXCL13-promoted cell migration and VCAM-1 expression in lung cancer cells. Finally, CXCL13 stimulated NF-κB transcription factor in lung cancer cells, contributing to VCAM-1 expression in translational level. These evidences propose a novel insight into lung cancer metastasis which is regulated by CXCL13.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/metabolismo , Quimiocina CXCL13/metabolismo , Neoplasias Pulmonares/metabolismo , Receptores CXCR5/metabolismo , Transducción de Señal , Carcinoma de Pulmón de Células no Pequeñas/genética , Carcinoma de Pulmón de Células no Pequeñas/patología , Línea Celular Tumoral , Movimiento Celular/genética , Quimiocina CXCL13/genética , Expresión Génica , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Metaanálisis como Asunto , FN-kappa B/metabolismo , Metástasis de la Neoplasia , Unión Proteica , Proteína Quinasa C-alfa/metabolismo , Receptores CXCR5/genética , Molécula 1 de Adhesión Celular Vascular/genética , Molécula 1 de Adhesión Celular Vascular/metabolismo , Familia-src Quinasas/metabolismo
16.
Artículo en Inglés | MEDLINE | ID: mdl-34299898

RESUMEN

Absorbable porcine collagen membrane with a bovine bone graft can be considered for regenerative treatment in periodontal class II furcation defects. We evaluated the clinical efficacy of guided tissue regeneration (GTR) treatment with bovine bone xenograft and a porcine collagen membrane in molars with class II furcations. Probing depth (PD), clinical attachment level (CAL), and bone level (BL) were recorded at baseline and at 3, 6, and 9 months postoperatively. Thirty class II furcation defects from the lower and upper molars were assessed. Significant improvements in PD and CAL were observed from baseline to 9 months in all groups (p < 0.01). BL improved in all groups except group A in the upper molars in radiographic assessment (p < 0.05). The lower and upper molars showed PD reduction of 50.5% ± 7.44% and 46.2% ± 11.2%, respectively, at 9 months (p = 0.044). In furcations of 1-3 mm, the lower and upper molars showed PD reductions of 51.2% ± 4.49% and 36.5% ± 16.14%, respectively (p = 0.035). The lower and upper molars showed a CAL gain of 51.1% ± 4.64% and 33.6% ± 18.8%, respectively (p = 0.037). Thus, GTR with bovine bone graft and porcine collagen membrane yielded good results in class II furcations, with better results in the lower than in the upper molars.


Asunto(s)
Regeneración Tisular Guiada Periodontal , Maxilar , Animales , Bovinos , Estudios de Seguimiento , Mandíbula , Membranas Artificiales , Pérdida de la Inserción Periodontal/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
17.
Aging (Albany NY) ; 13(13): 17227-17236, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34198264

RESUMEN

Osteoarthritis (OA) and rheumatoid arthritis (RA) are two of the most common types of arthritis. Both are characterized by the infiltration of a number of proinflammatory cytokines into the joint microenvironment. miRNAs play critical roles in the disease processes of arthritic disorders. However, little is known about the effects of miRNAs on critical inflammatory cytokine production with OA and RA progression. Here, we found higher levels of proinflammatory cytokines including interleukin 1 beta (IL-1ß), interleukin 6 (IL-6) and tumor necrosis factor alpha (TNF-α) in human OA and RA synovial fibroblasts (SFs) compared with normal SFs. Searches of open-source microRNA (miRNA) software determined that miR-let-7c-5p and miR-149-5p interfere with IL-1ß, IL-6 and TNF-α transcription; levels of all three proinflammatory cytokines were lower in human OA and RA patients compared with normal controls. Anti-inflammatory agents dexamethasone, celecoxib and indomethacin reduced proinflammatory cytokine production by promoting the expression of miR-let-7c-5p and miR-149-5p. Similarly, ibuprofen and methotrexate also enhanced miR-let-7c-5p and miR-149-5p expression in human SFs. The evidence suggests that increasing miR-let-7c-5p and miR-149-5p expression is a novel strategy for OA and RA.


Asunto(s)
Artritis Reumatoide/genética , Artritis Reumatoide/metabolismo , Citocinas/biosíntesis , Citocinas/genética , Fibroblastos/metabolismo , MicroARNs/genética , Osteoartritis/genética , Osteoartritis/metabolismo , Membrana Sinovial/metabolismo , Antiinflamatorios/farmacología , Antiinflamatorios no Esteroideos/farmacología , Fibroblastos/efectos de los fármacos , Humanos , Interleucina-1beta/genética , Interleucina-1beta/metabolismo , Interleucina-6/genética , Interleucina-6/metabolismo , MicroARNs/biosíntesis , Membrana Sinovial/citología , Membrana Sinovial/efectos de los fármacos , Factor de Necrosis Tumoral alfa
18.
J Cell Physiol ; 236(12): 8060-8069, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34192347

RESUMEN

Rheumatoid arthritis (RA) is an autoimmune disorder that is characterized by increasing levels of proinflammatory cytokines. The ubiquitous enzyme dipeptidyl peptidase-4 (DPP4, also known as CD26) regulates different immune disorders, although the effects of DPP4 in RA are uncertain. Here, we found lower levels of DPP4 in RA synovial tissues compared with normal tissues. DPP4 levels were also lower in a rat collagen-induced arthritis model than in control (healthy) rats. Overexpression of DPP4 or exogenous treatment of RA synovial fibroblasts with DPP4 reduced levels of proinflammatory interleukin (IL)-1ß, IL-6, and IL-13, and increased anti-inflammatory IL-10 synthesis, while DPP4 inhibitors sitagliptin and vildagliptin increased proinflammatory cytokine production, indicating an enhanced risk of RA development. The evidence suggests that increasing DPP4 expression is a novel strategy for RA disease.


Asunto(s)
Artritis Reumatoide/tratamiento farmacológico , Citocinas/efectos de los fármacos , Dipeptidil Peptidasa 4 , Fibroblastos/efectos de los fármacos , Animales , Artritis Reumatoide/metabolismo , Citocinas/metabolismo , Dipeptidil Peptidasa 4/metabolismo , Dipeptidil Peptidasa 4/farmacología , Fibroblastos/metabolismo , Humanos , Inflamación/tratamiento farmacológico , Inflamación/metabolismo , Membrana Sinovial/efectos de los fármacos , Membrana Sinovial/metabolismo
19.
Polymers (Basel) ; 13(5)2021 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-33800210

RESUMEN

In this study, five urethane acrylates (UAs), namely aliphatic urethane hexa-acrylate (87A), aromatic urethane hexa-acrylate (88A), aliphatic UA (588), aliphatic urethane triacrylate diluted in 15% HDD (594), and high-functional aliphatic UA (5812), were selected to formulate five UA-based photopolymer resins for digital light processing (DLP)-based 3D printing. Each UA (40 wt%) was added and blended homogenously with ethoxylated pentaerythritol tetraacrylate (40 wt%), isobornyl acrylate (12 wt%), diphenyl (2,4,6-trimethylbenzoyl) phosphine oxide (3 wt%), and a pink acrylic (5 wt%). Each UA-based resin specimen was designed using CAD software and fabricated using a DLP 3D printer to specific dimensions. Characteristics, mechanical properties, and cytotoxicity levels of these designed UA-based resins were investigated and compared with a commercial 3D printing denture base acrylic resin (BB base) control group at different UV exposure times. Shore hardness-measurement data and MTT assays were analyzed using a one-way analysis of variance with Bonferroni's post hoc test, whereas viscosity, maximum strength, and modulus were analyzed using the Kruskal-Wallis test (α = 0.05). UA-based photopolymer resins with tunable mechanical properties were successfully prepared by replacing the UA materials and the UV exposure times. After 15 min of UV exposure, the 5812 and 594 groups exhibited higher viscosities, whereas the 88A and 87A groups exhibited lower viscosities compared with the BB base group. Maximum flexural strength, flexural modulus, and Shore hardness values also revealed significant differences among materials (p < 0.001). Based on MTT assay results, the UA-based photopolymer resins were nontoxic. In the present study, mechanical properties of the designed photopolymer resins could be adjusted by changing the UA or UV exposure time, suggesting that aliphatic urethane acrylate has good potential for use in the design of printable resins for DLP-type 3D printing in dental applications.

20.
Artículo en Inglés | MEDLINE | ID: mdl-33921182

RESUMEN

Alzheimer's disease (AD) is a neurodegenerative disease that usually affects older individuals. Owing to the higher incidence of root caries and missing teeth in elderly individuals, the bacteria involved in these dental concerns might potentially deteriorate their cognitive function. Altered microbiota in the oral cavity may induce neuroinflammation through migration from the oral cavity to the brain. However, the correlation between the composition of the oral microbiota and neurodegenerative disease remains unclear. In this study, we evaluated sequence to determine the relative abundance and diversity of bacterial taxa in the dental plaque of elderly patients with AD and controls. Oral samples; the DMFT index; and other clinical examination data were collected from 17 patients with AD and 18 normal elderly individuals as the control group. Patients with AD had significantly more missing teeth and higher dental plaque weight but lower microbial diversity than controls. Significantly increased numbers of Lactobacillales, Streptococcaceae, and Firmicutes/Bacteroidetes and a significantly decreased number of Fusobacterium were observed in patients with AD. In conclusion, using the PacBio single-molecule real-time (SMRT) sequencing platform to survey the microbiota dysbiosis biomarkers in the oral cavity of elderly individuals could serve as a tool to identify patients with AD.


Asunto(s)
Enfermedad de Alzheimer , Caries Dental , Microbiota , Enfermedades Neurodegenerativas , Anciano , Enfermedad de Alzheimer/epidemiología , Caries Dental/epidemiología , Disbiosis , Humanos , ARN Ribosómico 16S/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...