Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Nat Rev Clin Oncol ; 14(3): 169-186, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27725679

RESUMEN

Imaging biomarkers (IBs) are integral to the routine management of patients with cancer. IBs used daily in oncology include clinical TNM stage, objective response and left ventricular ejection fraction. Other CT, MRI, PET and ultrasonography biomarkers are used extensively in cancer research and drug development. New IBs need to be established either as useful tools for testing research hypotheses in clinical trials and research studies, or as clinical decision-making tools for use in healthcare, by crossing 'translational gaps' through validation and qualification. Important differences exist between IBs and biospecimen-derived biomarkers and, therefore, the development of IBs requires a tailored 'roadmap'. Recognizing this need, Cancer Research UK (CRUK) and the European Organisation for Research and Treatment of Cancer (EORTC) assembled experts to review, debate and summarize the challenges of IB validation and qualification. This consensus group has produced 14 key recommendations for accelerating the clinical translation of IBs, which highlight the role of parallel (rather than sequential) tracks of technical (assay) validation, biological/clinical validation and assessment of cost-effectiveness; the need for IB standardization and accreditation systems; the need to continually revisit IB precision; an alternative framework for biological/clinical validation of IBs; and the essential requirements for multicentre studies to qualify IBs for clinical use.


Asunto(s)
Biomarcadores de Tumor , Neoplasias/diagnóstico , Toma de Decisiones Clínicas , Análisis Costo-Beneficio , Fluorodesoxiglucosa F18 , Ácido Fólico/análogos & derivados , Humanos , Neoplasias/economía , Compuestos de Organotecnecio , Tomografía de Emisión de Positrones/métodos , Pronóstico , Radiofármacos , Reproducibilidad de los Resultados , Proyectos de Investigación/normas , Sesgo de Selección
2.
Eur Radiol ; 26(2): 417-24, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25925359

RESUMEN

OBJECTIVES: To evaluate the efficiency of automatic respiratory gating (ARG) in reducing respiratory motion-induced artefacts from dynamic contrast-enhanced ultrasound (DCEUS) acquisitions and to assess the impact of ARG on DCEUS quantification parameters in patients with liver malignancies. METHODS: Twenty-five patients with liver metastasis were imaged with DCEUS. The lognormal indicator dilution model was fitted on time-intensity curves extracted from hepatic lesions with and without the use of ARG and DCEUS quantification parameters were extracted. The goodness of fit was assessed using the coefficient of determination (R (2) LN ). The effect respiration had on the data was assessed using the respiration amplitude (RA) metric. Pearson's correlation coefficient (r) was used to assess the correlation between R (2) LN and RA with and without the use of ARG. RESULTS: The RA parameter was strongly correlated with R (2) LN (r = -0.96, P = 7.412 × 10(-15)) and this correlation became weaker with ARG (r = -0.64, P = 5.449 × 10(-4)). ARG significantly influenced the values of the quantification parameters extracted (P ≤ 0.05). The RA was significantly decreased when ARG was used (P = 1.172 × 10(-6)). CONCLUSIONS: ARG has a significant impact on the quantification parameters extracted and it has been shown to improve the accuracy of liver lesion DCEUS. KEY POINTS: • ARG has a significant impact on DCEUS quantification parameters. • ARG can improve the modelling of liver lesion haemodynamics using DCEUS quantification. • ARG significantly reduces the respiration amplitude of DCEUS lesion time-intensity curves.


Asunto(s)
Artefactos , Medios de Contraste , Aumento de la Imagen , Neoplasias Hepáticas/diagnóstico por imagen , Respiración , Anciano , Femenino , Humanos , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Movimiento (Física) , Reproducibilidad de los Resultados , Ultrasonografía
3.
Ultrasound Med Biol ; 40(9): 2217-30, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25023101

RESUMEN

The aim of this study was to enable investigations into novel imaging and surgical techniques by developing a readily accessible, versatile liver machine perfusion system. Slaughterhouse pig livers were used, and dynamic contrast-enhanced ultrasound was introduced to optimize the procurement process and provide real-time perfusion monitoring. The system comprised a single pump, oxygenator, bubble trap and two flowmeters for pressure-controlled perfusion of the vessels using an off-the-shelf perfusate at room temperature. Successful livers exhibited homogeneous perfusion in both the portal vein and hepatic artery with dynamic contrast-enhanced ultrasound, which correlated with stable oxygen uptake, bile production and hepatic resistance and normal histology at the end of 3 h of perfusion. Dynamic contrast-enhanced ultrasound revealed perfusion abnormalities invisible to the naked eye, thereby providing context to the otherwise systemic biochemical/hemodynamic measurements and focal biopsy findings. The model developed here is a simple, cost-effective approach for stable ex vivo whole-organ machine perfusion.


Asunto(s)
Medios de Contraste/administración & dosificación , Aumento de la Imagen/métodos , Hígado/diagnóstico por imagen , Perfusión/métodos , Mataderos , Animales , Femenino , Masculino , Perfusión/instrumentación , Porcinos , Ultrasonografía
4.
Ultrasound Med Biol ; 39(2): 187-210, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23137926

RESUMEN

Initially, a set of guidelines for the use of ultrasound contrast agents was published in 2004 dealing only with liver applications. A second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some non-liver applications. Time has moved on, and the need for international guidelines on the use of CEUS in the liver has become apparent. The present document describes the third iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS) using contrast specific imaging techniques. This joint WFUMB-EFSUMB initiative has implicated experts from major leading ultrasound societies worldwide. These liver CEUS guidelines are simultaneously published in the official journals of both organizing federations (i.e., Ultrasound in Medicine and Biology for WFUMB and Ultraschall in der Medizin/European Journal of Ultrasound for EFSUMB). These guidelines and recommendations provide general advice on the use of all currently clinically available ultrasound contrast agents (UCA). They are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis and improve the management of patients worldwide.


Asunto(s)
Algoritmos , Medios de Contraste/normas , Aumento de la Imagen/normas , Neoplasias Hepáticas/diagnóstico por imagen , Guías de Práctica Clínica como Asunto , Ultrasonografía/normas , Humanos , Internacionalidad
5.
J Ultrasound Med ; 31(9): 1413-20, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22922621

RESUMEN

OBJECTIVES: The aim of this clinical study was to evaluate the reproducibility of quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound. METHODS: Fifteen patients with colorectal liver metastases and 5 volunteers were studied. The hepatic artery proper and the portal vein were imaged simultaneously with dynamic contrast-enhanced ultrasound. The examination was repeated with 2 different contrast bolus volumes (1.2 and 2.4 mL), and time-intensity curves were formed from dynamic contrast-enhanced ultrasound image loops. The rise time, peak intensity, and wash-in slope were derived from hepatic artery and portal vein time-intensity curves. Inter-reader, intra-reader, and inter-scan agreement was assessed by 2 independent readers. Quantitative (intraclass correlation coefficients and coefficients of variation [CVs]) and qualitative (Landis and Koch classification) analyses were performed. RESULTS: Intra-reader and inter-reader agreement was "almost perfect" for the hepatic artery (CV, 10%-15% and 8%-9%, respectively), portal vein (CV, 5%-8% and 6%-12%), and hepatic artery/portal vein ratio (CV, 8%-14% and 10%-15%) measurements of 3 all studied parameters. In contrast, inter-scan agreement was only "slight" to "moderate" (CV, 25%-27%) and "fair" to "moderate" (CV, 19%-24%) for rise time and peak intensity measurements in the hepatic artery and portal vein, respectively. CONCLUSIONS: Quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound is reproducible provided that measurements in the hepatic artery are normalized by those in the portal vein.


Asunto(s)
Neoplasias Colorrectales/patología , Arteria Hepática/diagnóstico por imagen , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/diagnóstico por imagen , Vena Porta/diagnóstico por imagen , Adulto , Anciano , Biopsia , Medios de Contraste , Femenino , Hemodinámica , Humanos , Neoplasias Hepáticas/secundario , Masculino , Microcirculación , Persona de Mediana Edad , Fosfolípidos , Estudios Prospectivos , Reproducibilidad de los Resultados , Hexafluoruro de Azufre , Ultrasonografía
6.
Cardiovasc Intervent Radiol ; 35(6): 1531-4, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22367010

RESUMEN

Patients with chemotherapy-refractory liver metastases who are not candidates for surgery may be treated with focal ablation techniques with established survival benefits. Irreversible electroporation is the newest of these and has the putative advantages of a nonthermal action, preventing damage to adjacent biliary structures and bowel. This report describes the use of irreversible electroporation in a 61-year-old man with a solitary chemoresistant liver metastasis unsuitable for radiofrequency ablation as a result of its proximity to the porta hepatis. At 3 months, tumor size was decreased on computed tomography from 28 × 19 to 20 × 17 mm, representing stable disease according to the response evaluation criteria in solid tumors. This corresponded to a decrease in tumor volume size from 5.25 to 3.16 cm(3). There were no early or late complications. Chemoresistant liver metastases in the proximity of the porta hepatis that are considered to be too high a risk for conventional surgery or thermal ablation may be considered for treatment by the novel ablation technique of irreversible electroporation.


Asunto(s)
Electroporación/métodos , Neoplasias Hepáticas/terapia , Protocolos de Quimioterapia Combinada Antineoplásica , Terapia Combinada , Medios de Contraste , Fluorouracilo , Hepatectomía , Humanos , Leucovorina , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Compuestos Organoplatinos , Fosfolípidos , Hexafluoruro de Azufre , Tomografía Computarizada por Rayos X , Ultrasonografía Intervencional
7.
Radiology ; 262(2): 672-9, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22156991

RESUMEN

PURPOSE: To quantify a pseudoenhancement phenomenon observed during dynamic contrast material-enhanced ultrasonography (US) of the carotid artery, both in vitro and in vivo. MATERIALS AND METHODS: Ethical approval was obtained prior to commencing this prospective case series, and each patient gave written informed consent. Thirty-one patients with 50%-99% internal carotid artery stenosis underwent dynamic contrast-enhanced US of the carotid bifurcation with use of 2 mL of microbubbles. In the final 10 patients, an additional 1 mL bolus was administered after 15 minutes. Raw linear digital imaging and communications in medicine data were analyzed offline. Regions of interest were drawn within the common carotid artery lumen and immediately adjacent to the lumen in the near and far wall adventitia. Peak intensity was measured. An in vitro experiment with a single-channel flow phantom was also performed. This apparatus consisted of an 8-mm-diameter latex tube placed in a tissue-mimicking fluid. Microbubble concentrations of 0.02%, 0.1%, 0.5%, 1%, and 2% were pumped into the tube. Regions of interest were drawn in a similar fashion to the in vivo experiments, and peak intensity was measured. The Wilcoxon signed rank and paired t tests were used to compare the difference between the near and far wall signal intensities at each dose; a multiplication factor comparing near and far wall signal intensity was derived. RESULTS: The far wall of the common carotid artery was significantly more echogenic than the near wall at 2 mL contrast agent doses (P<.0001, n=31), and the far wall signal intensity increased synchronously with that of the lumen. The difference in signal intensity between near and far wall regions was significantly greater at 2 mL than at 1 mL (P=.012, n=10). In vitro, the phantom tubing demonstrated a similar pattern and magnitude of enhancement to that seen in vivo. CONCLUSION: A dose-dependent, nonlinear propagation artifact known as pseudoenhancement occurs in the far wall adventitia of the carotid artery and should not be mistaken as a marker of plaque vulnerability.


Asunto(s)
Artefactos , Estenosis Carotídea/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Fosfolípidos/administración & dosificación , Hexafluoruro de Azufre/administración & dosificación , Ultrasonografía/métodos , Anciano , Anciano de 80 o más Años , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Stroke ; 42(12): 3634-6, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21960570

RESUMEN

BACKGROUND AND PURPOSE: Development of translational functional imaging modalities for atherosclerosis risk stratification is sought for stroke prediction. Our group has developed late-phase contrast-enhanced ultrasound (LP-CEUS) to quantify microbubble contrast retention within carotid atherosclerosis and shown it to separate asymptomatic plaques from those responsible for recent cerebrovascular events. We hypothesized that microbubbles are retained in areas of plaque inflammation, aiming to examine whether LP-CEUS signal reflects plaque biology. METHODS: Subjects awaiting carotid endarterectomy (n=31) underwent axial LP-CEUS and diseased intimal segments were symmetrically divided in the long axis. Half-specimens underwent quantitative immunohistochemical analysis for CD68 (macrophages) and CD31 (angiogenesis). Half-specimens were processed for atheroma cell culture and supernatant collected at 24 hours for multianalyte profiling for 34 analytes. RESULTS: Percentage area immunopositivity was significantly higher in subjects in which normalized plaque late-phase intensity was ≥0 versus <0 (CD68 mean 11.8 versus 6.68, P=0.004; CD31 mean 9.45 versus 4.82, P=0.025). Interleukin-6, matrix metalloproteinase-1, and matrix metalloproteinase-3 were significantly higher by multianalyte profiling when LP-CEUS was ≥0. CONCLUSIONS: LP-CEUS reflects biological features of inflammation and angiogenesis, key features predisposing to plaque rupture. Further investigation of LP-CEUS as a tissue-specific marker of inflammation for risk stratification of carotid atherosclerosis is warranted.


Asunto(s)
Aterosclerosis/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Anciano , Aterosclerosis/cirugía , Arterias Carótidas/cirugía , Enfermedades de las Arterias Carótidas/cirugía , Estenosis Carotídea/cirugía , Endarterectomía Carotidea , Femenino , Humanos , Inflamación/diagnóstico por imagen , Inflamación/cirugía , Masculino , Microburbujas , Ultrasonografía
9.
J Ultrasound Med ; 30(3): 379-85, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21357560

RESUMEN

OBJECTIVES: This study assessed the potential of quantitative analysis of contrast bolus kinetics to reflect global liver blood flow. METHODS: A dynamic contrast-enhanced ultrasound flow phantom was developed. A peristaltic pump established constant volume flow ranging between 16.5 and 49.5 mL/min (2-mm tube) and 85.5 and 256.5 mL/min (5-mm tube). After bolus injection of 2 doses of a contrast agent, a region of interest was drawn over the cross section of the tube used for a particular acquisition; the rise time, peak intensity, and wash-in slope were derived from time-intensity curves. Twenty healthy volunteers and 25 patients with biopsy-proven colorectal liver metastases were scanned with dynamic contrast-enhanced ultrasound. The rise time, peak intensity, and wash-in slope were derived from hepatic artery and portal vein time-intensity curves. Hepatic artery/portal vein ratios of the parameters were also calculated. RESULTS: In the in vitro experiment, the rise time decreased while the peak intensity and wash-in slope increased with increasing volume flow for both tube diameters and contrast bolus volumes. In the clinical study, the rise time was lowered in the hepatic artery but elevated in the portal vein, and the peak intensity and wash-in slope were elevated in the hepatic artery but lowered in the portal vein in patients with colorectal liver metastases compared with healthy volunteers, although not in a statistically significant manner. This finding was consistent with an increase in hepatic artery blood flow, a decrease in portal vein blood flow, or both in patients with colorectal liver metastases compared with healthy volunteers. Only the 3 hepatic artery/portal vein ratios of the parameters achieved statistical significance in differentiating healthy volunteers from patients with colorectal liver metastases (P < .05). CONCLUSIONS: Surrogate measurements of liver blood flow may be derived from quantitative analysis of dynamic contrast-enhanced ultrasound studies. They may have potential for quick and easy assessment of altered hepatic hemodynamics.


Asunto(s)
Arteria Hepática/diagnóstico por imagen , Arteria Hepática/fisiología , Venas Hepáticas/diagnóstico por imagen , Venas Hepáticas/fisiología , Circulación Hepática/fisiología , Ultrasonografía/métodos , Velocidad del Flujo Sanguíneo , Simulación por Computador , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Modelos Biológicos , Fantasmas de Imagen , Fosfolípidos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Hexafluoruro de Azufre , Ultrasonografía/instrumentación
10.
Circulation ; 123(5): 524-32, 2011 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-21262999

RESUMEN

BACKGROUND: Vein grafting in coronary artery surgery is complicated by a high restenosis rate resulting from the development of vascular inflammation, intimal hyperplasia, and accelerated atherosclerosis. In contrast, arterial grafts are relatively resistant to these processes. Vascular inflammation is regulated by signaling intermediaries, including p38 mitogen-activated protein (MAP) kinase, that trigger endothelial cell (EC) expression of chemokines (eg, interleukin-8, monocyte chemotactic protein-1) and other proinflammatory molecules. Here, we have tested the hypothesis that p38 MAP kinase activation in response to arterial shear stress (flow) may occur more readily in venous ECs, leading to greater proinflammatory activation. METHODS AND RESULTS: Comparative reverse-transcriptase polymerase chain reaction and Western blotting revealed that arterial shear stress induced p38-dependent expression of monocyte chemotactic protein-1 and interleukin-8 in porcine jugular vein ECs. In contrast, porcine aortic ECs were protected from shear stress-induced expression of p38-dependent chemokines as a result of rapid induction of MAP kinase phosphatase-1. However, we observed with both cultured porcine jugular vein ECs and perfused veins that venous ECs can be protected by brief treatment with dexamethasone, which induced MAP kinase phosphatase-1 to suppress proinflammatory activation. CONCLUSIONS: Arterial but not venous ECs are protected from proinflammatory activation in response to short-term exposure to high shear stress by the induction of MAP kinase phosphatase-1. Dexamethasone pretreatment arterializes venous ECs by inducing MAP kinase phosphatase-1 and may protect veins from inflammation.


Asunto(s)
Arterias/metabolismo , Dexametasona/farmacología , Endotelio Vascular/efectos de los fármacos , Proteína Quinasa 1 Activada por Mitógenos/genética , Venas/metabolismo , Animales , Antiinflamatorios , Arterias/efectos de los fármacos , Prótesis Vascular , Células Cultivadas , Células Endoteliales/efectos de los fármacos , Células Endoteliales/metabolismo , Endotelio Vascular/citología , Sustancias Protectoras , Porcinos , Activación Transcripcional/efectos de los fármacos , Venas/efectos de los fármacos
11.
Ultrasonics ; 51(1): 102-6, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20643467

RESUMEN

The objective of this study was to assess the impact of dynamic range and gain on perfusion quantification using linearized log-compressed data. An indicator-dilution experiment was developed with an in vitro flow phantom setup used with SonoVue contrast agent (Bracco SpA, Milan, Italy). Imaging was performed with a Philips iU22 scanner and a C5-1 curvilinear transducer using a contrast-specific nonlinear pulse sequence (power modulation) at 1.7MHz. Clinical dynamic contrast-enhanced ultrasound image loops of liver tumors were also collected for preliminary validation of the in vitro findings. Time-intensity curves were extracted from image loops with two different approaches: from linearized log-compressed data and from linear (uncompressed) data. The error of time-intensity curve parameters derived from linearized log-compressed data (deviation from linear data) was found to be less than 2.1% and 5.4% for all studied parameters in the in vitro experiment and in the clinical study, respectively, when a high dynamic range setting (at least 50dB on the iU22) is used. The gain must be carefully adjusted to ensure a high signal-to-noise ratio and to avoid signal saturation. From the time-intensity curve analysis it was also found that rise time of the bolus time-intensity curve is the least variable of all the studied time-intensity curve parameters.


Asunto(s)
Medios de Contraste , Neoplasias Hepáticas/diagnóstico por imagen , Fosfolípidos , Hexafluoruro de Azufre , Ultrasonografía/métodos , Área Bajo la Curva , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador , Técnicas In Vitro , Fantasmas de Imagen , Transductores , Ultrasonografía/instrumentación
12.
Radiology ; 255(2): 638-44, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20413774

RESUMEN

PURPOSE: To determine if the number of nontargeted microbubbles retained in human carotid plaque is sufficient to be detected with ultrasonography (US). MATERIALS AND METHODS: The study protocol was approved by the local research ethics committee. Informed consent was obtained. A total of 37 subjects with carotid atherosclerosis (mean age, 69.9 years; age range, 49-86 years), of whom 27 (73%) were men (mean age, 69.7 years; age range, 58-86 years) and 10 (27%) were women (mean age, 70.3 years; age range, 49-86 years), were studied between December 2008 and May 2009 with late-phase (LP) contrast material-enhanced US by using flash imaging with a nonlinear mode at an intermediate mechanical index of 0.34 6 minutes after bolus contrast agent injection. Plaques were defined as symptomatic if symptoms consistent with stroke, transient ischemic attack, or amaurosis fugax had occurred in the neurovascular territory of the plaque studied within 12 months prior to entry into the study. Plaques were defined as asymptomatic if no such events had ever occurred within the neurovascular territory. Raw linear data were used to quantify echogenicity of the plaque, which was normalized to lumen echogenicity. Gray-scale median score was also calculated. RESULTS: Of the 37 subjects, 16 (43%) had symptomatic plaques and 21 (57%) had asymptomatic plaques. All examinations yielded evaluable LP contrast-enhanced US data. Normalized LP plaque echogenicity was greater in the symptomatic group (0.39; 95% confidence interval: -0.11, 0.89) than in the asymptomatic group (0.69; 95% confidence interval: -1.04, -0.34) (P = .0005). There was a moderate (rho = -0.44, P = .016) inverse correlation between normalized LP plaque echogenicity and gray-scale median score. CONCLUSION: By quantifying microbubble retention within the carotid plaque, LP contrast-enhanced US depicts clear differences between groups of subjects with plaque ipsilateral to symptoms and asymptomatic plaques. This technique has promise as a tissue-specific marker of inflammation and a potential role in the risk stratification of atherosclerotic carotid stenosis.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Enfermedades de las Arterias Carótidas/patología , Medios de Contraste/administración & dosificación , Femenino , Humanos , Inflamación/diagnóstico por imagen , Inflamación/patología , Inyecciones Intravenosas , Masculino , Microburbujas , Persona de Mediana Edad , Fosfolípidos/administración & dosificación , Estudios Prospectivos , Sensibilidad y Especificidad , Hexafluoruro de Azufre/administración & dosificación , Ultrasonografía
14.
Radiology ; 232(3): 799-809, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15284434

RESUMEN

PURPOSE: To evaluate in a prospective multicenter study whether conventional ultrasonographic (US) characterization of liver lesions can be improved by imaging during the liver-specific phase of SH U 508A uptake in the microbubble-specific agent detection imaging mode. MATERIALS AND METHODS: One hundred forty-two patients with liver lesions underwent conventional gray-scale and color Doppler US and SH U 508A-enhanced US. Two radiologists blindly read digital cine clips and assigned scores for confidence in diagnosis of benignancy or malignancy, diagnosis of specific lesion types, and relative difference in SH U 508A uptake between the lesion and the liver parenchyma (ie, subjective conspicuity score [SCS]). Comparisons were made to see whether the addition of agent detection imaging led to improved diagnostic performance. RESULTS: Receiver operating characteristic analysis revealed improved discrimination of benign and malignant lesions for readers 1 (P =.049) and 2 (P <.001). The number of patients with a correct diagnosis of benignancy or malignancy assigned by readers 1 and 2, respectively, improved from 114 and 113 to 125 and 128 with agent detection imaging (reader 1: P =.027; reader 2: P =.008; McNemar test). Specific diagnoses were made more accurately with agent detection imaging: At McNemar testing, the number of correct lesion type determinations increased from 83 to 92 (P =.022) for reader 1 and from 85 to 99 (P <.001) for reader 2. Both readers assigned high scores for differences in SH U 508A uptake between the liver parenchyma and the lesion for metastases and cholangiocarcinomas and low scores for uptake differences in most of the benign lesions. Hepatocellular carcinomas (HCCs), hemangiomas, and adenomas had more variable uptake differences. Fourteen of 22 hemangiomas were assigned an SCS of less than 50%, and 22 (reader 1) and 15 (reader 2) of 31 HCCs were assigned an SCS of greater than 50%. CONCLUSION: With use of SH U 508A-enhanced agent detection imaging, liver lesion characterization and diagnostic performance are significantly improved.


Asunto(s)
Medios de Contraste , Neoplasias Hepáticas/diagnóstico por imagen , Microburbujas , Polisacáridos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...