Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomed Tech (Berl) ; 69(2): 211-217, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37924274

RESUMEN

OBJECTIVES: To evaluate tissue expansion during cryoablation, the displacement of markers in ex vivo kidney tissue was determined using computed tomographic (CT) imaging. METHODS: CT-guided cryoablation was performed in nine porcine kidneys over a 10 min period. Markers and fiber optic temperature probes were positioned perpendicular to the cryoprobe shaft in an axial orientation. The temperature measurement was performed simultaneously with the acquisitions of the CT images in 5 s intervals. The distance change of the markers to the cryoprobe was determined in each CT image and equated to the measured temperature at the marker. RESULTS: The greatest increase in the distance between the markers and the cryoprobe was observed in the initial phase of cryoablation. The maximum displacement of the markers was determined to be 0.31±0.2 mm and 2.8±0.02 %, respectively. CONCLUSIONS: The mean expansion of ex vivo kidney tissue during cryoablation with a single cryoprobe is 0.31±0.2 mm. The results can be used for identification of basic parameters for optimization of therapy planning.


Asunto(s)
Criocirugía , Porcinos , Animales , Criocirugía/métodos , Riñón/cirugía , Tomografía Computarizada por Rayos X/métodos , Temperatura , Expansión de Tejido
2.
Int J Hyperthermia ; 39(1): 1315-1326, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36220179

RESUMEN

OBJECTIVES: We want to investigate whether temperature measurements obtained from MR thermometry are accurate and reliable enough to aid the development and validation of simulation models for Laser-induced interstitial thermotherapy (LITT). METHODS: Laser-induced interstitial thermotherapy (LITT) is applied to ex-vivo porcine livers. An artificial blood vessel is used to study the cooling effect of large blood vessels in proximity to the ablation zone. The experimental setting is simulated using a model based on partial differential equations (PDEs) for temperature, radiation, and tissue damage. The simulated temperature distributions are compared to temperature data obtained from MR thermometry. RESULTS: The overall agreement between measurement and simulation is good for two of our four test cases, while for the remaining cases drift problems with the thermometry data have been an issue. At higher temperatures local deviations between simulation and measurement occur in close proximity to the laser applicator and the vessel. This suggests that certain aspects of the model may need some refinement. CONCLUSION: Thermometry data is well-suited for aiding the development of simulations models since it shows where refinements are necessary and enables the validation of such models.


Asunto(s)
Sustitutos Sanguíneos , Hipertermia Inducida , Terapia por Láser , Termometría , Animales , Simulación por Computador , Rayos Láser , Imagen por Resonancia Magnética , Porcinos
3.
Biomed Tech (Berl) ; 64(4): 449-457, 2019 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-30243013

RESUMEN

The purpose of this study was to develop a thermometry software tool for temperature monitoring during laser-induced interstitial thermotherapy (LITT). C++ programming language and several libraries including DICOM Toolkit, Grassroots DICOM library, Insight Segmentation and Registration Toolkit, Visualization Toolkit and Quasar Toolkit were used. The software's graphical user interface creates windows displaying the temperature map and the coagulation extent in the tissue, determined by the magnetic resonance imaging (MRI) thermometry with the echo planar imaging sequence and a numerical simulation based on the radiation and heat transfer in biological tissues, respectively. The software was evaluated applying the MRI-guided LITT to ex vivo pig liver and simultaneously measuring the temperature through a fiber-optic thermometer as reference. Using the software, the temperature distribution determined by the MRI method was compared with the coagulation extent simulation. An agreement was shown between the MRI temperature map and the simulated coagulation extent. Furthermore, the MRI-based and simulated temperatures agreed with the measured one - a correlation coefficient of 0.9993 and 0.9996 was obtained, respectively. The precision of the MRI temperature amounted to 2.4°C. In conclusion, the software tool developed in the present study can be applied for monitoring and controlling the LITT procedure in ex vivo tissues.


Asunto(s)
Hipertermia Inducida/métodos , Hígado/fisiopatología , Imagen por Resonancia Magnética/métodos , Animales , Rayos Láser , Programas Informáticos , Porcinos , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...