Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
PLoS One ; 14(1): e0210866, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30682062

RESUMEN

BACKGROUND: Human immunodeficiency virus (HIV) testing is critical for early linkage to treatment and care services. However, there is a substantial gap in HIV testing, particularly in resource limited settings due to low accessibility of HIV testing sites, inconvenient testing hours, and concerns about loss of confidentiality. Thus, adopting new strategies such as HIV self-testing (HIVST) could overcome these barriers and increases HIV testing uptake. OBJECTIVE: The aim of this study was to evaluate the diagnostic performance of non-invasive HIVST kit using oral fluid for HIV diagnosis. This study also aimed to assess the ability of clients in interpretation of OraQuick HIVST results. METHOD: Between December 2017 and February 2018, a total of 400 study participants were enrolled into the study to assess a diagnostic accuracy of Oral fluid-based HIVST kit (OraQuick) in 15 public health facilities in Addis Ababa, Ethiopia. Participants were provided with instructions and visual aids on how to perform HIVST and interpret results. They also underwent a blood-based rapid HIV antibody test as per the current national algorithm. The results of HIVST were interpreted independently by the participants and respective health care workers (HCWs). The sensitivity, specificity, positive predictive value (PPV), Negative predictive value (NPV) and inter-rater agreement of the test were computed. RESULTS: Out of 200 participants who tested positive on the national algorithm testing, oral fluid-based self-testing was positive in 199 (99.5%), false negative in 1 (0.5%). Of 200 participants who tested negative on the national algorithm testing, self-testing was negative in 200 (100%). There were no false positive and invalid tests. The sensitivity and specificity of the OraQuick HIVST were 99.5% (95%CI: 97.26-99.99) and 100% (95%CI: 98.18-100.0), respectively. The overall agreement between the two tests was high (κ value = 0.995). The PPV and NPV of OraQuick test were 100% and 99.5% (95%CI: 96.59-99.93) respectively. CONCLUSION: This study showed a high diagnostic performance of OraQuick HIV self-test and suggests that OraQuick HIVST kit has a potential to be used for HIV testing in Ethiopia along with the national algorithm.


Asunto(s)
Serodiagnóstico del SIDA/métodos , Infecciones por VIH/diagnóstico , Juego de Reactivos para Diagnóstico , Serodiagnóstico del SIDA/estadística & datos numéricos , Adolescente , Adulto , Algoritmos , Estudios Transversales , Etiopía , Femenino , VIH-1 , VIH-2 , Humanos , Masculino , Valor Predictivo de las Pruebas , Juego de Reactivos para Diagnóstico/estadística & datos numéricos , Autocuidado , Sensibilidad y Especificidad , Adulto Joven
2.
Ethiop Med J ; 52 Suppl 3: 119-28, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25845081

RESUMEN

BACKGROUND: Program managers require feasible, timely, reliable, and valid measures of iCCM implementation to identify problems and assess progress. The global iCCM Task Force developed benchmark indicators to guide implementers to develop or improve monitoring and evaluation (M&E) systems. OBJECTIVE: To assesses Ethiopia's iCCM M&E system by determining the availability and feasibility of the iCCM benchmark indicators. METHODS: We conducted a desk review of iCCM policy documents, monitoring tools, survey reports, and other rele- vant documents; and key informant interviews with government and implementing partners involved in iCCM scale-up and M&E. RESULTS: Currently, Ethiopia collects data to inform most (70% [33/47]) iCCM benchmark indicators, and modest extra effort could boost this to 83% (39/47). Eight (17%) are not available given the current system. Most benchmark indicators that track coordination and policy, human resources, service delivery and referral, supervision, and quality assurance are available through the routine monitoring systems or periodic surveys. Indicators for supply chain management are less available due to limited consumption data and a weak link with treatment data. Little information is available on iCCM costs. CONCLUSION: Benchmark indicators can detail the status of iCCM implementation; however, some indicators may not fit country priorities, and others may be difficult to collect. The government of Ethiopia and partners should review and prioritize the benchmark indicators to determine which should be included in the routine M&E system, especially since iCCMdata are being reviewed for addition to the HMIS. Moreover, the Health Extension Worker's reporting burden can be minimized by an integrated reporting approach.


Asunto(s)
Benchmarking , Manejo de Caso/normas , Servicios de Salud Comunitaria/normas , Garantía de la Calidad de Atención de Salud/normas , Indicadores de Calidad de la Atención de Salud , Calidad de la Atención de Salud/normas , Prestación Integrada de Atención de Salud , Etiopía , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...