Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Appl Lab Med ; 8(2): 285-295, 2023 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-36592084

RESUMEN

BACKGROUND: Using middleware solutions, it is possible to implement concentration-dependent analyte-specific hemolysis rejection limits. This makes day-to-day reporting of clinical specimens more efficient and potentially lowers sample rejection rates compared to a "one-size-fits-all" approach (i.e., solely based on a single cutoff provided in the package insert). METHODS: Hemolysis interference studies were performed at multiple analyte concentrations for three frequently ordered tests. For each assay, concentration-dependent hemolysis rejection limits were designed based on the total allowable error (TAE) for the analyte as well as the clinical significance of such incurred inaccuracy at the respective concentrations. In general, the following rationale was used: if the interference exceeds 10% (or package insert cutoffs), a comment is placed on the result. If the interference exceeds the TAE, the result will not be reported. Reduction in specimen rejection rates were estimated by comparing the incurred specimen rejection rates when package inserts' vs concentration-dependent hemolysis interference limits were applied to a data set in our institute during a three-month period. RESULTS: Concentration-dependent analyte-specific hemolysis rejection thresholds were designed for three commonly ordered assays that are especially susceptible to hemolysis interference. It is estimated that these novel thresholds for aspartate aminotransferase (AST), lactate dehydrogenase (LDH), and direct bilirubin (DBIL) reduced specimen rejection rates from 9.3% to 1.3%, 31.4% to 4.8%, and 19.9% to 7.1%, respectively. CONCLUSIONS: Concentration-dependent analyte-specific hemolysis rejection thresholds for three commonly ordered assays can reduce rejection rates without significantly compromising the quality of test results.


Asunto(s)
Hemólisis , L-Lactato Deshidrogenasa , Humanos , Aspartato Aminotransferasas , Bilirrubina
2.
Am J Clin Pathol ; 157(1): 109-118, 2022 01 06.
Artículo en Inglés | MEDLINE | ID: mdl-34463315

RESUMEN

OBJECTIVES: To analytically and clinically evaluate the semiquantitative Elecsys anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein antibody (S-Ab) assay on the Roche cobas e602 analyzer. METHODS: The S-Ab assay is a 1-step, double-antigen sandwich electrochemiluminescent immunoassay that semiquantitatively measures total IgG, IgM, and IgA antibodies specific for the receptor binding domain of SARS-CoV-2 spike protein in serum or plasma. The S-Ab assay was evaluated for precision, linearity, interference (by hemoglobin, bilirubin, triglycerides, and biotin), cross-reactivity, and clinical performance, and was compared to the qualitative Elecsys anti-nucleocapsid (N-Ab) immunoassay, a lateral flow device that qualitatively detects S-Ab and N-Ab, and an anti-spike enzyme-linked immunosorbent assay (ELISA). RESULTS: S-Ab assay is precise, exhibits linearity from 0.4 to 250 U/mL, is unaffected by significant cross-reactivity or interferences, and qualitatively demonstrates greater than 90% concordance with N-Ab assay and lateral flow device. Readouts of S-Ab assay correlate with ELISA, which in turn correlates strongly with SARS-CoV-2 virus neutralization assay, and exhibit 100% sensitivity and specificity for COVID-19 patient samples obtained at or more than 14 days after PCR positivity. CONCLUSIONS: The S-Ab assay is a robust clinical test for qualitative and semiquantitative detection of seropositivity following SARS-CoV-2 infection or spike-encoding mRNA COVID-19 vaccination.


Asunto(s)
COVID-19 , Glicoproteína de la Espiga del Coronavirus , Anticuerpos Antivirales , Vacunas contra la COVID-19 , Humanos , SARS-CoV-2 , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA