Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acta Crystallogr D Struct Biol ; 80(Pt 1): 16-25, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38088897

RESUMEN

The technique of time-resolved macromolecular crystallography (TR-MX) has recently been rejuvenated at synchrotrons, resulting in the design of dedicated beamlines. Using pump-probe schemes, this should make the mechanistic study of photoactive proteins and other suitable systems possible with time resolutions down to microseconds. In order to identify relevant time delays, time-resolved spectroscopic experiments directly performed on protein crystals are often desirable. To this end, an instrument has been built at the icOS Lab (in crystallo Optical Spectroscopy Laboratory) at the European Synchrotron Radiation Facility using reflective focusing objectives with a tuneable nanosecond laser as a pump and a microsecond xenon flash lamp as a probe, called the TR-icOS (time-resolved icOS) setup. Using this instrument, pump-probe spectra can rapidly be recorded from single crystals with time delays ranging from a few microseconds to seconds and beyond. This can be repeated at various laser pulse energies to track the potential presence of artefacts arising from two-photon absorption, which amounts to a power titration of a photoreaction. This approach has been applied to monitor the rise and decay of the M state in the photocycle of crystallized bacteriorhodopsin and showed that the photocycle is increasingly altered with laser pulses of peak fluence greater than 100 mJ cm-2, providing experimental laser and delay parameters for a successful TR-MX experiment.


Asunto(s)
Proteínas , Sincrotrones , Análisis Espectral , Proteínas/química , Cristalografía , Luz
2.
IUCrJ ; 9(Pt 6): 756-767, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36381146

RESUMEN

The development of serial crystallography over the last decade at XFELs and synchrotrons has produced a renaissance in room-temperature macromolecular crystallography (RT-MX), and fostered many technical and methodological breakthroughs designed to study phenomena occurring in proteins on the picosecond-to-second timescale. However, there are components of protein dynamics that occur in much slower regimes, of which the study could readily benefit from state-of-the-art RT-MX. Here, the room-temperature structural study of the relaxation of a reaction intermediate at a synchrotron, exploiting a handful of single crystals, is described. The intermediate in question is formed in microseconds during the photoreaction of the LOV2 domain of phototropin 2 from Arabidopsis thaliana, which then decays in minutes. This work monitored its relaxation in the dark using a fast-readout EIGER X 4M detector to record several complete oscillation X-ray diffraction datasets, each of 1.2 s total exposure time, at different time points in the relaxation process. Coupled with in crystallo UV-Vis absorption spectroscopy, this RT-MX approach allowed the authors to follow the relaxation of the photoadduct, a thio-ether covalent bond between the chromophore and a cysteine residue. Unexpectedly, the return of the chromophore to its spectroscopic ground state is followed by medium-scale protein rearrangements that trigger a crystal phase transition and hinder the full recovery of the structural ground state of the protein. In addition to suggesting a hitherto unexpected role of a conserved tryptophan residue in the regulation of the photocycle of LOV2, this work provides a basis for performing routine time-resolved protein crystallography experiments at synchrotrons for phenomena occurring on the second-to-hour timescale.

3.
IUCrJ ; 7(Pt 4): 728-736, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32695419

RESUMEN

The recent development of serial crystallography has popularized time-resolved crystallography as a technique to determine the structure of protein-reaction intermediate states. However, most approaches rely on the availability of thousands to millions of microcrystals. A method is reported here, using monochromatic synchrotron radiation, for the room-temperature collection, processing and merging of X-ray oscillation diffraction data from <100 samples in order to observe the build up of a photoreaction intermediate species. Using this method, we monitored with a time resolution of 63 ms how the population of a blue-light photoreceptor domain in a crystal progressively photoconverts from the dark to the light state. The series of resulting snapshots allows us to visualize in detail the gradual rearrangement of both the protein and chromophore during this process.

4.
J Synchrotron Radiat ; 27(Pt 3): 844-851, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32381789

RESUMEN

ID30A-3 (or MASSIF-3) is a mini-focus (beam size 18 µm × 14 µm) highly intense (2.0 × 1013 photons s-1), fixed-energy (12.81 keV) beamline for macromolecular crystallography (MX) experiments at the European Synchrotron Radiation Facility (ESRF). MASSIF-3 is one of two fixed-energy beamlines sited on the first branch of the canted undulator setup on the ESRF ID30 port and is equipped with a MD2 micro-diffractometer, a Flex HCD sample changer, and an Eiger X 4M fast hybrid photon-counting detector. MASSIF-3 is recommended for collecting diffraction data from single small crystals (≤15 µm in one dimension) or for experiments using serial methods. The end-station has been in full user operation since December 2014, and here its current characteristics and capabilities are described.

5.
Acta Crystallogr D Struct Biol ; 75(Pt 6): 528-535, 2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-31205015

RESUMEN

Recent improvements in direct electron detectors, microscope technology and software provided the stimulus for a `quantum leap' in the application of cryo-electron microscopy in structural biology, and many national and international centres have since been created in order to exploit this. Here, a new facility for cryo-electron microscopy focused on single-particle reconstruction of biological macromolecules that has been commissioned at the European Synchrotron Radiation Facility (ESRF) is presented. The facility is operated by a consortium of institutes co-located on the European Photon and Neutron Campus and is managed in a similar fashion to a synchrotron X-ray beamline. It has been open to the ESRF structural biology user community since November 2017 and will remain open during the 2019 ESRF-EBS shutdown.


Asunto(s)
Microscopía por Crioelectrón/métodos , Sustancias Macromoleculares/ultraestructura , Programas Informáticos , Sincrotrones/instrumentación , Virus del Mosaico del Tabaco/ultraestructura , Francia , Nicotiana/virología , Rayos X
6.
J Synchrotron Radiat ; 25(Pt 4): 1249-1260, 2018 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-29979188

RESUMEN

ID30B is an undulator-based high-intensity, energy-tuneable (6.0-20 keV) and variable-focus (20-200 µm in diameter) macromolecular crystallography (MX) beamline at the ESRF. It was the last of the ESRF Structural Biology Group's beamlines to be constructed and commissioned as part of the ESRF's Phase I Upgrade Program and has been in user operation since June 2015. Both a modified microdiffractometer (MD2S) incorporating an in situ plate screening capability and a new flexible sample changer (the FlexHCD) were specifically developed for ID30B. Here, the authors provide the current beamline characteristics and detail how different types of MX experiments can be performed on ID30B (http://www.esrf.eu/id30b).

7.
IUCrJ ; 5(Pt 2): 166-171, 2018 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-29765606

RESUMEN

Determining macromolecular structures from X-ray data with resolution worse than 3 Šremains a challenge. Even if a related starting model is available, its incompleteness or its bias together with a low observation-to-parameter ratio can render the process unsuccessful or very time-consuming. Yet, many biologically important macromolecules, especially large macromolecular assemblies, membrane proteins and receptors, tend to provide crystals that diffract to low resolution. A new algorithm to tackle this problem is presented that uses a multivariate function to simultaneously exploit information from both an initial partial model and low-resolution single-wavelength anomalous diffraction data. The new approach has been used for six challenging structure determinations, including the crystal structures of membrane proteins and macromolecular complexes that have evaded experts using other methods, and large structures from a 3.0 Šresolution F1-ATPase data set and a 4.5 Šresolution SecYEG-SecA complex data set. All of the models were automatically built by the method to Rfree values of between 28.9 and 39.9% and were free from the initial model bias.

8.
Sci Adv ; 3(5): e1602952, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28508075

RESUMEN

We describe a fast, easy, and potentially universal method for the de novo solution of the crystal structures of membrane proteins via iodide-single-wavelength anomalous diffraction (I-SAD). The potential universality of the method is based on a common feature of membrane proteins-the availability at the hydrophobic-hydrophilic interface of positively charged amino acid residues with which iodide strongly interacts. We demonstrate the solution using I-SAD of four crystal structures representing different classes of membrane proteins, including a human G protein-coupled receptor (GPCR), and we show that I-SAD can be applied using data collection strategies based on either standard or serial x-ray crystallography techniques.


Asunto(s)
Yoduros , Receptores Acoplados a Proteínas G/química , Dispersión del Ángulo Pequeño , Cristalografía por Rayos X/métodos , Humanos , Dominios Proteicos
9.
Acta Crystallogr D Struct Biol ; 72(Pt 8): 966-75, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27487827

RESUMEN

Automation of the mounting of cryocooled samples is now a feature of the majority of beamlines dedicated to macromolecular crystallography (MX). Robotic sample changers have been developed over many years, with the latest designs increasing capacity, reliability and speed. Here, the development of a new sample changer deployed at the ESRF beamline MASSIF-1 (ID30A-1), based on an industrial six-axis robot, is described. The device, named RoboDiff, includes a high-capacity dewar, acts as both a sample changer and a high-accuracy goniometer, and has been designed for completely unattended sample mounting and diffraction data collection. This aim has been achieved using a high level of diagnostics at all steps of the process from mounting and characterization to data collection. The RoboDiff has been in service on the fully automated endstation MASSIF-1 at the ESRF since September 2014 and, at the time of writing, has processed more than 20 000 samples completely automatically.


Asunto(s)
Cristalografía por Rayos X/instrumentación , Proteínas/química , Animales , Bacillus/química , Proteínas Bacterianas/química , Bovinos , Cristalografía por Rayos X/economía , Cristalografía por Rayos X/métodos , Diseño de Equipo , Robótica , Programas Informáticos , Termolisina/química , Tripsina/química
10.
Sci Rep ; 6: 19988, 2016 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-26817994

RESUMEN

LysR Type Transcriptional Regulators (LTTRs) regulate basic metabolic pathways or virulence gene expression in prokaryotes. Evidence suggests that the activation of LTTRs involves a conformational change from an inactive compact apo- configuration that represses transcription to an active, expanded holo- form that promotes it. However, no LTTR has yet been observed to adopt both configurations. Here, we report the results of structural studies of various forms of the LTTR DntR. Crystal structures of apo-DntR and of a partially autoinducing mutant H169T-DntR suggest that active and inactive DntR maintain a compact homotetrameric configuration. However, Small Angle X-ray Scattering (SAXS) studies on solutions of apo-, H169T- and inducer-bound holo-DntR indicate a different behaviour, suggesting that while apo-DntR maintains a compact configuration in solution both H169T- and holo-DntR adopt an expanded conformation. Models of the SAXS-obtained solution conformations of apo- and holo-DntR homotetramers in complex with promoter-operator region DNA are consistent with previous observations of a shifting of LTTR DNA binding sites upon activation and a consequent relaxation in the bend of the promoter-operator region DNA. Our results thus provide clear evidence at the molecular level which strongly supports the 'sliding dimer' hypothesis concerning LTTR activation mechanisms.


Asunto(s)
Proteínas Bacterianas/química , Modelos Moleculares , Conformación Proteica , Multimerización de Proteína , Factores de Transcripción/química , Secuencia de Bases , Cristalografía por Rayos X , ADN/química , ADN/metabolismo , Regiones Promotoras Genéticas , Unión Proteica , Dispersión del Ángulo Pequeño , Soluciones , Difracción de Rayos X
11.
J Synchrotron Radiat ; 22(6): 1540-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26524320

RESUMEN

MASSIF-1 (ID30A-1) is an ESRF undulator beamline operating at a fixed wavelength of 0.969 Å (12.8 keV) that is dedicated to the completely automatic characterization of and data collection from crystals of biological macromolecules. The first of the ESRF Upgrade MASSIF beamlines to be commissioned, it has been open since September 2014, providing a unique automated data collection service to academic and industrial users. Here, the beamline characteristics and details of the new service are outlined.


Asunto(s)
Cristalización/instrumentación , Cristalografía por Rayos X/instrumentación , Almacenamiento y Recuperación de la Información/métodos , Complejos Multiproteicos/química , Complejos Multiproteicos/ultraestructura , Sincrotrones/instrumentación , Algoritmos , Biopolímeros/química , Diseño de Equipo , Análisis de Falla de Equipo , Robótica/instrumentación
12.
Acta Crystallogr D Biol Crystallogr ; 71(Pt 11): 2328-43, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26527148

RESUMEN

Here, an automated procedure is described to identify the positions of many cryocooled crystals mounted on the same sample holder, to rapidly predict and rank their relative diffraction strengths and to collect partial X-ray diffraction data sets from as many of the crystals as desired. Subsequent hierarchical cluster analysis then allows the best combination of partial data sets, optimizing the quality of the final data set obtained. The results of applying the method developed to various systems and scenarios including the compilation of a complete data set from tiny crystals of the membrane protein bacteriorhodopsin and the collection of data sets for successful structure determination using the single-wavelength anomalous dispersion technique are also presented.


Asunto(s)
Cristalografía por Rayos X/métodos , Proteínas/química , Animales , Bacillus/química , Bacteriorodopsinas/química , Bombyx/química , Análisis por Conglomerados , Cristalización/métodos , Halobacterium salinarum/química , Proteínas de Insectos/química , Modelos Moleculares , Muramidasa/química , Proteínas de Plantas/química , Plantas/química , Sincrotrones , Termolisina/química , Flujo de Trabajo
13.
Acta Crystallogr D Biol Crystallogr ; 71(Pt 1): 15-26, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25615856

RESUMEN

The analysis of structural data obtained by X-ray crystallography benefits from information obtained from complementary techniques, especially as applied to the crystals themselves. As a consequence, optical spectroscopies in structural biology have become instrumental in assessing the relevance and context of many crystallographic results. Since the year 2000, it has been possible to record such data adjacent to, or directly on, the Structural Biology Group beamlines of the ESRF. A core laboratory featuring various spectrometers, named the Cryobench, is now in its third version and houses portable devices that can be directly mounted on beamlines. This paper reports the current status of the Cryobench, which is now located on the MAD beamline ID29 and is thus called the ID29S-Cryobench (where S stands for `spectroscopy'). It also reviews the diverse experiments that can be performed at the Cryobench, highlighting the various scientific questions that can be addressed.


Asunto(s)
Sustancias Macromoleculares/química , Espectrofotometría Ultravioleta/métodos , Espectrometría Raman/métodos , Color , ADN/química , Proteínas/química
14.
Acta Crystallogr D Biol Crystallogr ; 69(Pt 7): 1289-96, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23793155

RESUMEN

The ESRF has worked with, and provided services for, the pharmaceutical industry since the construction of its first protein crystallography beamline in the mid-1990s. In more recent times, industrial clients have benefited from a portfolio of beamlines which offer a wide range of functionality and beam characteristics, including tunability, microfocus and micro-aperture. Included in this portfolio is a small-angle X-ray scattering beamline dedicated to the study of biological molecules in solution. The high demands on throughput and efficiency made by the ESRF's industrial clients have been a major driving force in the evolution of the ESRF's macromolecular crystallography resources, which now include remote access, the automation of crystal screening and data collection, and a beamline database allowing sample tracking, experiment reporting and real-time at-a-distance monitoring of experiments. This paper describes the key features of the functionality put in place on the ESRF structural biology beamlines and outlines the major advantages of the interaction of the ESRF with the pharmaceutical industry.


Asunto(s)
Cristalografía por Rayos X , Recolección de Datos , Procesamiento Automatizado de Datos , Industrias , Sustancias Macromoleculares/química , Sincrotrones/instrumentación , Bases de Datos Factuales , Europa (Continente)
15.
J Synchrotron Radiat ; 19(Pt 3): 455-61, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22514185

RESUMEN

ID29 is an ESRF undulator beamline with a routinely accessible energy range of between 20.0 keV and 6.0 keV (λ = 0.62 Što 2.07 Å) dedicated to the use of anomalous dispersion techniques in macromolecular crystallography. Since the beamline was first commissioned in 2001, ID29 has, in order to provide an improved service to both its academic and proprietary users, been the subject of almost continuous upgrade and refurbishment. It is now also the home to the ESRF Cryobench facility, ID29S. Here, the current status of the beamline is described and plans for its future are briefly outlined.


Asunto(s)
Sustancias Macromoleculares/química , Sincrotrones/instrumentación , Tripsina/química , Difracción de Rayos X
16.
Bioinformatics ; 27(22): 3186-92, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-21949273

RESUMEN

MOTIVATION: Individual research groups now analyze thousands of samples per year at synchrotron macromolecular crystallography (MX) resources. The efficient management of experimental data is thus essential if the best possible experiments are to be performed and the best possible data used in downstream processes in structure determination pipelines. Information System for Protein crystallography Beamlines (ISPyB), a Laboratory Information Management System (LIMS) with an underlying data model allowing for the integration of analyses down-stream of the data collection experiment was developed to facilitate such data management. RESULTS: ISPyB is now a multisite, generic LIMS for synchrotron-based MX experiments. Its initial functionality has been enhanced to include improved sample tracking and reporting of experimental protocols, the direct ranking of the diffraction characteristics of individual samples and the archiving of raw data and results from ancillary experiments and post-experiment data processing protocols. This latter feature paves the way for ISPyB to play a central role in future macromolecular structure solution pipelines and validates the application of the approach used in ISPyB to other experimental techniques, such as biological solution Small Angle X-ray Scattering and spectroscopy, which have similar sample tracking and data handling requirements.


Asunto(s)
Cristalografía por Rayos X/métodos , Sistemas de Información Administrativa , Proteínas/química , Sincrotrones , Cristalografía por Rayos X/instrumentación , Recolección de Datos , Sustancias Macromoleculares/química , Difracción de Rayos X
17.
Mol Microbiol ; 81(2): 354-67, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21692874

RESUMEN

Activation of LysR-type transcription factors (LTTRs) is thought to result from conformational changes that occur when inducer molecules bind to their Inducer Binding Domains (IBDs). However, the exact nature of these changes remains to be fully elucidated. We present the crystal structures of two truncated constructs of the LTTR DntR in their apo- forms and in complex with its natural inducer molecule, salicylate. These provide a fuller picture of the conformational changes that can occur in LTTR IBDs and offer insights that may be relevant when considering the mechanism of activation of LTTRs. Two of the crystal structures show that DntR IBDs can bind up to two inducer molecules. The full extent of conformational changes observed is achieved only when inducer molecules are bound in both binding sites identified. Point mutations disrupting the putative secondary binding site produce DntR variants with a reduced response to salicylate in a whole cell system, suggesting that this site is functionally relevant.


Asunto(s)
Burkholderia/química , Salicilatos/química , Factores de Transcripción/química , Regulación Alostérica , Sitios de Unión , Cristalografía por Rayos X , Modelos Moleculares , Proteínas Mutantes/genética , Proteínas Mutantes/metabolismo , Mutación Puntual , Unión Proteica , Conformación Proteica , Estructura Terciaria de Proteína , Salicilatos/metabolismo , Factores de Transcripción/genética , Factores de Transcripción/metabolismo
18.
Mol Microbiol ; 79(5): 1260-75, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21208302

RESUMEN

Fur, the ferric uptake regulator, is a transcription factor that controls iron metabolism in bacteria. Binding of ferrous iron to Fur triggers a conformational change that activates the protein for binding to specific DNA sequences named Fur boxes. In Helicobacter pylori, HpFur is involved in acid response and is important for gastric colonization in model animals. Here we present the crystal structure of a functionally active HpFur mutant (HpFur2M; C78S-C150S) bound to zinc. Although its fold is similar to that of other Fur and Fur-like proteins, the crystal structure of HpFur reveals a unique structured N-terminal extension and an unusual C-terminal helix. The structure also shows three metal binding sites: S1 the structural ZnS4 site previously characterized biochemically in HpFur and the two zinc sites identified in other Fur proteins. Site-directed mutagenesis and spectroscopy analyses of purified wild-type HpFur and various mutants show that the two metal binding sites common to other Fur proteins can be also metallated by cobalt. DNA protection and circular dichroism experiments demonstrate that, while these two sites influence the affinity of HpFur for DNA, only one is absolutely required for DNA binding and could be responsible for the conformational changes of Fur upon metal binding while the other is a secondary site.


Asunto(s)
Proteínas Bacterianas/química , Proteínas Bacterianas/metabolismo , Helicobacter pylori/metabolismo , Hierro/metabolismo , Proteínas Represoras/química , Proteínas Represoras/metabolismo , Secuencia de Aminoácidos , Proteínas Bacterianas/genética , Sitios de Unión , ADN Bacteriano/metabolismo , Helicobacter pylori/química , Helicobacter pylori/genética , Datos de Secuencia Molecular , Estructura Secundaria de Proteína , Proteínas Represoras/genética , Alineación de Secuencia
19.
Acta Crystallogr D Biol Crystallogr ; 66(Pt 8): 855-64, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20693684

RESUMEN

Crystals of biological macromolecules often exhibit considerable inter-crystal and intra-crystal variation in diffraction quality. This requires the evaluation of many samples prior to data collection, a practice that is already widespread in macromolecular crystallography. As structural biologists move towards tackling ever more ambitious projects, new automated methods of sample evaluation will become crucial to the success of many projects, as will the availability of synchrotron-based facilities optimized for high-throughput evaluation of the diffraction characteristics of samples. Here, two examples of the types of advanced sample evaluation that will be required are presented: searching within a sample-containing loop for microcrystals using an X-ray beam of 5 microm diameter and selecting the most ordered regions of relatively large crystals using X-ray beams of 5-50 microm in diameter. A graphical user interface developed to assist with these screening methods is also presented. For the case in which the diffraction quality of a relatively large crystal is probed using a microbeam, the usefulness and implications of mapping diffraction-quality heterogeneity (diffraction cartography) are discussed. The implementation of these techniques in the context of planned upgrades to the ESRF's structural biology beamlines is also presented.


Asunto(s)
Cristalografía por Rayos X/métodos , Animales , Bovinos , Mitocondrias/enzimología , ATPasas de Translocación de Protón/análisis , ATPasas de Translocación de Protón/química , Receptores Adrenérgicos beta/análisis , Receptores Adrenérgicos beta/química , Termolisina/análisis , Termolisina/química
20.
J Synchrotron Radiat ; 17(5): 700-7, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20724792

RESUMEN

The design and features of a beamline control software system for macromolecular crystallography (MX) experiments developed at the European Synchrotron Radiation Facility (ESRF) are described. This system, MxCuBE, allows users to easily and simply interact with beamline hardware components and provides automated routines for common tasks in the operation of a synchrotron beamline dedicated to experiments in MX. Additional functionality is provided through intuitive interfaces that enable the assessment of the diffraction characteristics of samples, experiment planning, automatic data collection and the on-line collection and analysis of X-ray emission spectra. The software can be run in a tandem client-server mode that allows for remote control and relevant experimental parameters and results are automatically logged in a relational database, ISPyB. MxCuBE is modular, flexible and extensible and is currently deployed on eight macromolecular crystallography beamlines at the ESRF. Additionally, the software is installed at MAX-lab beamline I911-3 and at BESSY beamline BL14.1.


Asunto(s)
Cristalografía por Rayos X/métodos , Programas Informáticos , Sincrotrones , Hidrolasas de Éster Carboxílico/química , Bases de Datos Factuales , Sustancias Macromoleculares/química , Espectrometría por Rayos X , Termolisina/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...