J Vasc Interv Radiol ; 31(5): 812-819.e1, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32107125

RESUMEN

PURPOSE: To assess the feasibility of transarterial chemoembolization with drug-eluting embolic (DEE) microspheres in a woodchuck model of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Nine woodchucks were studied: 4 normal animals and 5 animals infected with woodchuck hepatitis virus in which HCC had developed. Three animals with HCC underwent multidetector CT. A 3-F sheath was introduced into the femoral artery, and the hepatic arteries were selectively catheterized with 2.0-2.4-F microcatheters. Normal animals underwent diagnostic angiography and bland embolization. Animals with HCC underwent DEE transarterial chemoembolization with 70-150-µm radiopaque microspheres loaded with 37.5 mg doxorubicin per milliliter. Cone-beam CT and multidetector CT were performed. Following euthanasia, explanted livers underwent micro-CT, histopathologic examination, and fluorescence imaging of doxorubicin. RESULTS: The tumors were hypervascular and supplied by large-caliber tortuous vessels, with arteriovenous shunts present in 2 animals. There was heterogeneous enhancement on multidetector CT with areas of necrosis. Six tumors were identified. The most common location was the right medial lobe (n = 3). Mean tumor volume was 30.7 cm3 ± 12.3. DEE chemoembolization of tumors was achieved. Excluding the 2 animals with arteriovenous shunts, the mean volume of DEE microspheres injected was 0.49 mL ± 0.17. Fluorescence imaging showed diffusion of doxorubicin from the DEE microspheres into the tumor. CONCLUSIONS: Woodchuck HCC shares imaging appearances and biologic characteristics with human HCC. Selective catheterization and DEE chemoembolization may similarly be performed. Woodchucks may be used to model interventional therapies and possibly characterize radiologic-pathologic correlations.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica , Doxorrubicina/administración & dosificación , Neoplasias Hepáticas/terapia , Angiografía de Substracción Digital , Animales , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/virología , Tomografía Computarizada de Haz Cónico , Modelos Animales de Enfermedad , Femenino , Hepatitis B/complicaciones , Hepatitis B/virología , Virus de la Hepatitis B de la Marmota/patogenicidad , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/virología , Masculino , Marmota , Microscopía Fluorescente , Microesferas , Tomografía Computarizada Multidetector , Carga Tumoral
2.
J Vasc Interv Radiol ; 30(12): 1908-1914, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31409568

RESUMEN

PURPOSE: To determine whether burn time per tumor volume (BPV) (min/mL), where burn time is the total time during which radiofrequency (RF) energy is being applied, is correlated with hepatocellular carcinoma (HCC) treatment outcomes using RF ablation and lyso-thermosensitive liposomal doxorubicin (LTLD). MATERIALS AND METHODS: The HEAT study was a double-blind, randomized controlled phase III trial of RF ablation only versus RF ablation + LTLD in patients with HCCs 3-7 cm in diameter. Effect of BPV on progression-free survival and overall survival (OS) was analyzed. RESULTS: BPV demonstrated statistically significant differences between study groups for OS (P = .038, hazard ratio [HR] = 0.85), but not for progression-free survival (P = .389, HR = 1.059). In a separate analysis, treatment groups were independently analyzed to determine the effect of BPV within each individual group. OS improved as BPV increased for patients receiving RF ablation + LTLD (P = .017, HR = 0.836, confidence interval [0.722, 0.968]). This same association was not observed in patients receiving RF ablation only (P = .57, HR = 0.99). CONCLUSIONS: BPV may be a useful metric for RF ablation + LTLD combination therapy for solitary HCC. The analysis suggested that the burn time for the tumor needs to be adjusted depending on the tumor volume. Because this is a post hoc study, the results are only suggestive and need to be confirmed with prospective studies.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Carcinoma Hepatocelular/terapia , Doxorrubicina/análogos & derivados , Neoplasias Hepáticas/terapia , Tempo Operativo , Ablación por Radiofrecuencia , Carga Tumoral , Antibióticos Antineoplásicos/efectos adversos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/patología , Quimioterapia Adyuvante , Ensayos Clínicos Fase III como Asunto , Progresión de la Enfermedad , Doxorrubicina/administración & dosificación , Doxorrubicina/efectos adversos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/patología , Polietilenglicoles/administración & dosificación , Polietilenglicoles/efectos adversos , Supervivencia sin Progresión , Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/mortalidad , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Factores de Tiempo
3.
Artículo en Inglés | MEDLINE | ID: mdl-33134858

RESUMEN

Retrievable inferior vena cava (IVC) filters are self-expanding metallic devices implanted in the IVC to prevent migration of thrombi from the deep veins of the legs and pelvis to the lungs. The risk of complications from the filters increases with duration of implantation, but retrieval may be difficult due to intimal hyperplasia around the components of the filter. In this study, the potential for delivery of radiofrequency (RF) energy to the IVC wall via the filter was investigated. IVC filters were deployed in 4 swine while attached to a snare connected to a 480 kHz RF generator. Energy ranging from 0 to 48 kJ was applied via the filter followed by re-sheathing and withdrawal of the filter while connected to a force measurement device. Resheathing forces for the 0-energy cohort and pooled data from the 6-24 kJ cohorts were 4.50±0.70 N and 4.50±0.75 N, respectively. Petechial hemorrhages and variable non-occlusive thrombi were noted in some cohorts including the 0-energy cohort, consistent with delivery and acute retrieval of an IVC filter. Histologically, the extent of RF-induced injury was subtle at 6 kJ with focal areas of homogenized collagen while the 12 kJ cohort showed segmental tissue charring with coagulation necrosis which was more extensive for the 24 kJ cohort. The 48 kJ energy caused more extensive and non-target organ damage. The study demonstrated feasibility of delivery of RF to the IVC wall via a deployed filter, supporting further study of the ability of local RF heating of the IVC wall to inhibit the neointimal hyperplasia or as an aid in retrieval.