Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 348
Filtrar
1.
Phys Med ; 121: 103346, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38608421

RESUMEN

Partial breast irradiation for the treatment of early-stage breast cancer patients can be performed by means of Intra Operative electron Radiation Therapy (IOeRT). One of the main limitations of this technique is the absence of a treatment planning system (TPS) that could greatly help in ensuring a proper coverage of the target volume during irradiation. An IOeRT TPS has been developed using a fast Monte Carlo (MC) and an ultrasound imaging system to provide the best irradiation strategy (electron beam energy, applicator position and bevel angle) and to facilitate the optimisation of dose prescription and delivery to the target volume while maximising the organs at risk sparing. The study has been performed in silico, exploiting MC simulations of a breast cancer treatment. Ultrasound-based input has been used to compute the absorbed dose maps in different irradiation strategies and a quantitative comparison between the different options was carried out using Dose Volume Histograms. The system was capable of exploring different beam energies and applicator positions in few minutes, identifying the best strategy with an overall computation time that was found to be completely compatible with clinical implementation. The systematic uncertainty related to tissue deformation during treatment delivery with respect to imaging acquisition was taken into account. The potential and feasibility of a GPU based full MC TPS implementation of IOeRT breast cancer treatments has been demonstrated in-silico. This long awaited tool will greatly improve the treatment safety and efficacy, overcoming the limits identified within the clinical trials carried out so far.


Asunto(s)
Neoplasias de la Mama , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/diagnóstico por imagen , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Electrones/uso terapéutico , Factores de Tiempo , Gráficos por Computador , Femenino , Órganos en Riesgo/efectos de la radiación
2.
Ultrasound Obstet Gynecol ; 63(2): 263-270, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37725753

RESUMEN

OBJECTIVE: To determine the diagnostic test accuracy of transvaginal ultrasound (TVS) using a standardized technique for the diagnosis of deep endometriosis (DE) of the uterosacral ligaments (USLs) and adjacent torus uterinus (TU). METHODS: This was a prospective diagnostic test accuracy study conducted at the McMaster University Medical Center Tertiary Endometriosis Clinic, Hamilton, ON, Canada. Consecutive participants were enrolled if they successfully underwent TVS and surgery by our team from 10 August 2020 to 31 October 2021. The index test was TVS using a standardized posterior approach performed and interpreted by an expert sonologist. The reference standard included direct surgical visualization on laparoscopy by the same person who performed and interpreted the ultrasound scans. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios were calculated for the TVS posterior approach for each location using the reference standard. RESULTS: There were 54 consecutive participants included upon completion of laparoscopy and histological assessment. The prevalence of DE for the left USL, right USL and TU was 42.6%, 22.2% and 14.8%, respectively. Based on surgical visualization as the reference standard, TVS demonstrated an accuracy of 92.6% (95% CI, 82.1-97.9%), sensitivity of 82.6% (95% CI, 61.2-95.1%), specificity of 100% (95% CI, 88.8-100%), PPV of 100% and NPV of 88.6% (95% CI, 76.1-95.0%) for diagnosing DE in the left USL. For DE of the right USL, TVS demonstrated an accuracy of 94.4% (95% CI, 84.6-98.8%), sensitivity of 75.0% (95% CI, 42.8-94.5%), specificity of 100% (95% CI, 91.6-100%), PPV of 100% and NPV of 93.3% (95% CI, 84.0-97.4%). For DE of the TU, TVS demonstrated an accuracy of 100% (95% CI, 93.4-100%), sensitivity of 100% (95% CI, 63.1-100%), specificity of 100% (95% CI, 92.3-100%), PPV of 100% and NPV of 100%. CONCLUSIONS: We observed high diagnostic test accuracy of the evaluated standardized TVS technique for assessing DE of the USLs and TU. Further studies evaluating this technique should be performed, particularly with less experienced observers, before considering this technique as the standard approach. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Endometriosis , Vagina , Femenino , Embarazo , Humanos , Vagina/diagnóstico por imagen , Vagina/patología , Endometriosis/diagnóstico por imagen , Endometriosis/cirugía , Sensibilidad y Especificidad , Estudios Prospectivos , Ultrasonografía/métodos , Ligamentos/diagnóstico por imagen , Ligamentos/patología , Pruebas Diagnósticas de Rutina
4.
J Helminthol ; 97: e45, 2023 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-37309645

RESUMEN

Previous descriptions of Corynosoma bullosum (Linstow, 1892) show that specimens vary greatly in the proportions of different body structures, measurements of females and males, number of rows of hooks, and egg measurements, among other features. We redescribe this species from specimens found in southern elephant seal faeces from King George Island. We also provide a molecular characterization, in addition to 5.8S and internal transcribed spacer (ITS) existing sequences. We examined 41 elephant seals, and 30 adult acanthocephalans were found in 15 of them. The specimens were identified as belonging to the genus Corynosoma due to each having a tubular body with an inflated anterior part forming a thorny disk and the posterior part bearing somatic spines on the ventral surface, and genital spines surrounding the genital pore. Individual morphology corresponded to C. bullosum: large size, marked sexual dimorphism, and proboscis with 16-18 rows of spines with 11-15 spines per row. The molecular profile of three specimens of C. bullosum was analysed using 18S rDNA. We inferred phylogenetic relationships of the family Polymorphidae using maximum likelihood and Bayesian inference. We provide an updated morphological redescription for C. bullosum including electron microscopy photographs and molecular data. The 18S gene sequences showed low genetic variation and supported that C. bullosum is a sister to Corynosoma australe.


Asunto(s)
Acantocéfalos , Phocidae , Animales , Femenino , Masculino , Regiones Antárticas , Teorema de Bayes , Filogenia
5.
Crit Rev Oncol Hematol ; 187: 104035, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37244324

RESUMEN

The present white paper, referring to the 4th Assisi Think Tank Meeting on breast cancer, reviews state-of-the-art data, on-going studies and research proposals. <70% agreement in an online questionnaire identified the following clinical challenges: 1: Nodal RT in patients who have a) 1-2 positive sentinel nodes without ALND (axillary lymph node dissection); b) cN1 disease transformed into ypN0 by primary systemic therapy and c) 1-3 positive nodes after mastectomy and ALND. 2. The optimal combination of RT and immunotherapy (IT), patient selection, IT-RT timing, and RT optimal dose, fractionation and target volume. Most experts agreed that RT- IT combination does not enhance toxicity. 3: Re-irradiation for local relapse converged on the use of partial breast irradiation after second breast conserving surgery. Hyperthermia aroused support but is not widely available. Further studies are required to finetune best practice, especially given the increasing use of re-irradiation.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/tratamiento farmacológico , Mastectomía , Escisión del Ganglio Linfático , Biopsia del Ganglio Linfático Centinela , Mastectomía Segmentaria , Axila/patología , Ganglios Linfáticos/patología
6.
Data Brief ; 45: 108609, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36425958

RESUMEN

The development of a highly efficient multijunction technology is a key challenge for the future of photovoltaic and for the transition to more renewable energy sources. In this scenario, four-terminal architecture (4T) compared to the classic tandem design allows a large intrinsic robustness to the variations of the solar spectrum, which continuously occur under normal outdoor operation conditions. On the other hand, bifacial solar cells and modules have already proven to be able to increase the energy yield of solar farms at reduced costs. For these reasons, a thorough investigation of the compatibility between these two solutions has been performed by combining a III-V semiconductor with the silicon heterojunction technology in a four-terminal device. This work has been designed in support of the research article entitled "Outdoor performance of GaAs/Bifacial Si Heterojunction four-terminal system using optical spectrum splitting" [1], which showed, through data modeling and an accurate daily analysis of the spectral distribution of solar light, how a four-terminal architecture guarantees the consistency of the bifacial gain and more robust performances than a two-terminal system. Here additional data on the manufacturing, optimization and characterization of the device are presented.

7.
Front Mol Biosci ; 9: 880660, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35911957

RESUMEN

K+ channels allow a very efficient passage of K+ ions through the membrane while excluding Na+ ions, and these properties are essential for life. The 3D structure of the KcsA K+ channel, solved more than 20 years ago, allows to address many relevant aspects of K+ permeation and selectivity mechanisms at the molecular level. Recent crystallographic data and molecular dynamics (MD) studies suggest that no water is normally present inside the selectivity filter (SF), which can instead accommodate four adjacent K+ ions. Using a multi-scale approach, whereby information taken from a low-level simulation approach is used to feed a high-level model, we studied the mechanism of K+ permeation through KcsA channels. More specifically, we used MD to find stable ion configurations under physiological conditions. They were characterized by two adjacent K+ ions occupying the more central positions of the SF (sites S2 and S3), while the other two K+ ions could be found at the external and internal entrances to the SF. Sites S1 and S4 were instead not occupied by K+. A continuum Bikerman-Poisson-Boltzmann model that takes into account the volume of the ions and their dehydration when entering the SF fully confirmed the MD results, showing peaks of K+ occupancy at S2, S3, and the external and internal entrances, with S1 and S4 sites being virtually never occupied by K+. Inspired by the newly found ion configuration in the SF at equilibrium, we developed a simple kinetic permeation model which, fed with kinetic rate constants assessed from molecular meta-dynamics, reproduced the main permeation properties of the KcsA channel found experimentally, including sublinear current-voltage and saturating conductance-concentration relationships. This good agreement with the experimental data also implies that the ion configuration in the SF we identified at equilibrium would also be a key configuration during permeation.

8.
Crit Care ; 26(1): 245, 2022 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-35948933

RESUMEN

The use of instrumental tools for improving both the diagnostic accuracy and the prognostic soundness in patients with disorders of consciousness (DOC) plays an important role. However, the most recent international guidelines on DOC published by the American and the European Academies of Neurology and by the UK Royal College of Physicians contain heterogeneous recommendations on the implementation of these techniques in the clinical routine for both diagnosis and prognosis. With the present work, starting from the comparison of the DOC guidelines' recommendations, we look for possible explanations behind such discrepancies considering the adopted methodologies and the reference health systems that could have affected the guidelines' perspectives. We made a provocative argument about the need to find the most appropriate common methodology to retrieve and grade the evidence, increase the meta-analytic studies, and reduce the health policies that influence on the guidelines development that, in turn, should inform the health policies with the strongest scientific evidence.


Asunto(s)
Estado de Conciencia , Neurología , Trastornos de la Conciencia/diagnóstico , Humanos , Pronóstico , Reino Unido , Estados Unidos
9.
Ultrasound Obstet Gynecol ; 60(3): 404-413, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35561121

RESUMEN

OBJECTIVE: To evaluate the diagnostic accuracy of transvaginal ultrasound (TVS) in predicting deep endometriosis (DE) following the International Deep Endometriosis Analysis (IDEA) consensus methodology. METHODS: This was an international multicenter prospective diagnostic accuracy study involving eight centers across six countries (August 2018-November 2019). Consecutive participants with endometriosis suspected based on clinical symptoms or historical diagnosis of endometriosis were included. The index test was TVS performed preoperatively in accordance with the IDEA consensus statement. At each center, the index test was interpreted by a single sonologist. Reference standards were: (1) direct visualization of endometriosis at laparoscopy, as determined by a non-blinded surgeon with expertise in endometriosis surgery; and (2) histological assessment of biopsied/excised tissue. Surgery was performed within 12 months following the index TVS. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios (LR+ and LR-) of TVS in the diagnosis of DE were calculated. RESULTS: Included in the study were 273 participants with complete clinical, TVS, laparoscopic and histological data. Of these, based on histology, 256 (93.8%) were confirmed to have endometriosis, including superficial endometriosis, and 190 (69.6%) were confirmed to have DE. Based on surgical visualization, 207/273 (75.8%) patients had DE. For DE overall, the diagnostic performance of TVS based on surgical visualization as the reference standard was as follows: accuracy, 86.1%; sensitivity, 88.4%; specificity, 78.8%; PPV, 92.9%; NPV, 68.4%; LR+, 4.17; LR-, 0.15, and the diagnostic performance of TVS based on histology as the reference standard was as follows: accuracy, 85.9%; sensitivity, 89.8%; specificity, 75.9%; PPV, 90.4%; NPV, 74.6%; LR+, 3.72; LR-, 0.13. CONCLUSIONS: Using the IDEA consensus methodology provides strong diagnostic accuracy for TVS assessment of DE. We found a higher TVS detection rate of DE overall than that reported by the most recent meta-analysis on the topic (sensitivity, 79%), albeit with a lower specificity. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Endometriosis , Endometriosis/diagnóstico por imagen , Endometriosis/patología , Endometriosis/cirugía , Femenino , Humanos , Proyectos Piloto , Embarazo , Estudios Prospectivos , Sensibilidad y Especificidad , Ultrasonografía/métodos , Vagina/diagnóstico por imagen , Vagina/patología
10.
Ultrasound Obstet Gynecol ; 60(3): 309-327, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35229963

RESUMEN

Endometriosis is a chronic systemic disease that can cause pain, infertility and reduced quality of life. Diagnosing endometriosis remains challenging, which yields diagnostic delays for patients. Research on diagnostic test accuracy in endometriosis can be difficult due to verification bias, as not all patients with endometriosis undergo definitive diagnostic testing. The purpose of this State-of-the-Art Review is to provide a comprehensive update on the strengths and limitations of the diagnostic modalities used in endometriosis and discuss the relevance of diagnostic test accuracy research pertaining to each. We performed a comprehensive literature review of the following methods: clinical assessment including history and physical examination, biomarkers, diagnostic imaging, surgical diagnosis and histopathology. Our review suggests that, although non-invasive diagnostic methods, such as clinical assessment, ultrasound and magnetic resonance imaging, do not yet qualify formally as replacement tests for surgery in diagnosing all subtypes of endometriosis, they are likely to be appropriate for advanced stages of endometriosis. We also demonstrate in our review that all methods have strengths and limitations, leading to our conclusion that there should not be a single gold-standard diagnostic method for endometriosis, but rather, multiple accepted diagnostic methods appropriate for different circumstances. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Endometriosis , Pruebas Diagnósticas de Rutina , Endometriosis/diagnóstico por imagen , Endometriosis/cirugía , Femenino , Humanos , Imagen por Resonancia Magnética , Embarazo , Calidad de Vida , Ultrasonografía/métodos
11.
Ultrasound Obstet Gynecol ; 59(3): 385-391, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34919760

RESUMEN

OBJECTIVE: To compare the preoperative detection of endometriosis using transvaginal sonography (TVS) supplemented by transabdominal sonography (TAS) with surgical assessment of disease, using the #Enzian classification for endometriosis. METHODS: This was a prospective multicenter diagnostic accuracy study of women undergoing TVS/TAS and radical surgery for deep endometriosis (DE) at different tertiary referral centers. The localization and grade of severity of the endometriotic lesions and adhesions were described according to the criteria of the #Enzian classification, both at preoperative ultrasound examination and during surgery. According to the #Enzian classification, the small pelvis is divided into three compartments for DE: A (rectovaginal septum and vagina); B (uterosacral and cardinal ligaments, parametrium and pelvic sidewalls); and C (rectum). In addition, further locations (F) are classified as adenomyosis (FA), urinary bladder involvement (FB) and ureteric involvement with signs of obstruction (FU). Other intestinal locations (FI) and other extragenital locations (FO) are also included. Ovarian endometriosis and adhesions at the level of the tubo-ovarian unit are listed as O and T, respectively. The #Enzian grade of severity (Grade 1-3) was determined for #Enzian compartments O, T, A, B and C based on the size of the lesion or the severity of the adhesions. Concordance between preoperative assessment using TVS/TAS and evaluation at surgery was assessed. The sensitivity, specificity, positive and negative predictive values and accuracy of TVS/TAS in the detection of endometriotic lesions/adhesions in the different #Enzian compartments were calculated. RESULTS: In total, 745 women were included in the analysis. Preoperative TVS/TAS and surgical findings showed a concordance rate ranging between 86% and 99% for the presence or absence of endometriotic lesions/adhesions, depending on the evaluated #Enzian compartment. The concordance rate between TVS and surgery ranged between 71% and 92% for different severity grades, in #Enzian compartments O, T, A, B and C. Determining the presence or absence of adhesions at the level of the tubo-ovarian unit and classifying them accurately as Grade 1, 2 or 3 on TVS was more difficult than determining the presence and severity of endometriotic lesions in #Enzian compartments O, A, B and C. The sensitivity of TVS/TAS for the detection of endometriotic lesions ranged from 50% (#Enzian compartment FI) to 95% (#Enzian compartment A), specificity from 86% (#Enzian compartment Tleft ) to 99% (#Enzian compartment FI) and 100% (#Enzian compartments FB, FU and FO), positive predictive value from 90% (#Enzian compartment Tright ) to 100% (#Enzian compartment FO), negative predictive value from 74% (#Enzian compartment Bleft ) to 99% (#Enzian compartments FB and FU) and accuracy from 88% (#Enzian compartment Bright ) to 99% (#Enzian compartment FB). CONCLUSIONS: The localization and severity of endometriotic lesions/adhesions, as described and classified according to the #Enzian classification, can be diagnosed accurately and non-invasively using TVS/TAS. The #Enzian classification provides a uniform classification system for describing endometriotic lesions, which can be used both at TVS/TAS and during surgical evaluation. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Endometriosis , Endometriosis/patología , Femenino , Humanos , Estudios Prospectivos , Recto/diagnóstico por imagen , Sensibilidad y Especificidad , Adherencias Tisulares/patología , Ultrasonografía , Vagina/diagnóstico por imagen
12.
Hum Reprod Open ; 2021(4): hoab041, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34869918

RESUMEN

STUDY QUESTION: Is there an ideal imaging modality for the detection of uterosacral ligaments/torus uterinus (USL), rectovaginal septum (RVS) and vaginal deep endometriosis (DE) in women with a clinical history of endometriosis? SUMMARY ANSWER: The sensitivity for the detection of USL, RVS and vaginal DE using MRI seems to be better than transvaginal ultrasonography (TVS), whilst the specificity of both were excellent. WHAT IS KNOWN ALREADY: The surgical management of women with DE can be complex and requires advanced laparoscopic skills with maximal cytoreduction being vital at the first procedure to provide the greatest symptomatic benefit. Owing to a correlation of TVS findings with surgical findings, preoperative imaging has been used to adequately consent women and plan the appropriate surgery. However, until publication of the consensus statement by the International Deep Endometriosis Analysis Group in 2016, there were significant variations within the terms and definitions used to describe DE in the pelvis. STUDY DESIGN SIZE DURATION: A systematic review and meta-analysis was conducted using Embase, Google Scholar, Medline, PubMed and Scopus to identify studies published from inception to May 2020, of which only those from 2010 were included owing to the increased proficiency of the sonographers and advancements in technology. PARTICIPANTS/MATERIALS SETTING METHODS: All prospective studies that preoperatively assessed any imaging modality for the detection of DE in the USL, RVS and vagina and correlated with the reference standard of surgical data were considered eligible. Study eligibility was restricted to those including a minimum of 10 unaffected and 10 affected participants. MAIN RESULTS AND THE ROLE OF CHANCE: There were 1977 references identified from which 10 studies (n = 1188) were included in the final analysis. For the detection of USL DE, the overall pooled sensitivity and specificity for all TVS techniques were 60% (95% CI 32-82%) and 95% (95% CI 90-98%), respectively, and for all MRI techniques were 81% (95% CI 66-90%) and 83% (95% CI 62-94%), respectively. For the detection of RVS DE, the overall pooled sensitivity and specificity for all TVS techniques were 57% (95% CI 30-80%) and 100% (95% CI 92-100%), respectively. For the detection of vaginal DE, the overall pooled sensitivity and specificity for all TVS techniques were 52% (95% CI 29-74%) and 98% (95% CI 95-99%), respectively, and for all MRI techniques were 64% (95% CI 40-83%) and 98% (96% CI 93-99%). Pooled analyses were not possible for other imaging modalities. LIMITATIONS REASONS FOR CAUTION: There was a low quality of evidence given the high risk of bias and heterogeneity in the included studies. There are also potential biases secondary to the risk of misdiagnosis at surgery owing to a lack of either histopathological findings or expertise, coupled with the surgeons not being blinded. Furthermore, the varying surgical experience and the lack of clarity regarding complete surgical clearance, thereby also contributing to the lack of histopathology, could also explain the wide range of pre-test probability of disease. WIDER IMPLICATIONS OF THE FINDINGS: MRI outperformed TVS for the per-operative diagnosis of USL, RVS and vaginal DE with higher sensitivities, although the specificities for both were excellent. There were improved results with other imaging modalities, such as rectal endoscopy-sonography, as well as the addition of bowel preparation or ultrasound gel to either TVS or MRI, although these are based on individual studies. STUDY FUNDING/COMPETING INTERESTS: No funding was received for this study. M.L. reports personal fees from GE Healthcare, grants from the Australian Women's and Children's Foundation, outside the submitted work. B.W.M. reports grants from NHMRC, outside the submitted work. G.C. reports personal fees from GE Healthcare, outside the submitted work; and is on the Endometriosis Advisory Board for Roche Diagnostics. REGISTRATION NUMBER: Prospective registration with PROSPERO (CRD42017059872) was obtained.

13.
Front Oncol ; 11: 723693, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34504801

RESUMEN

Breast cancer is the most common malignancy occurring during gestation. In early-stage breast cancer during pregnancy (PrBC), breast-conserving surgery (BCS) with delayed RT is a rational alternative to mastectomy, for long considered the standard-of-care. Regrettably, no specific guidelines on the surgical management of these patients are available. In this study, we investigated the feasibility and safety of BCS during the first trimester of pregnancy in women with early-stage PrBC. All patients with a diagnosis of PrBC during the first trimester of pregnancy jointly managed in two PrBC-specialized Centers were included in this study. All patients underwent BCS followed by adjuvant radiotherapy to the ipsilateral breast after delivery. Histopathological features and biomarkers were first profiled on pre-surgical biopsies. The primary outcome was the isolated local recurrence (ILR). Among 168 PrBC patients, 67 (39.9%) were diagnosed during the first trimester of gestation. Of these, 30 patients (age range, 23-43 years; median=36 years; gestational age, 2-12 weeks; median=7 weeks; median follow-up time=6.5 years) met the inclusion criteria. The patients that were subjected to radical surgery (n=14) served as controls. None of the patients experienced perioperative surgical complications. No ILR were observed within three months (n=30), 1 year (n=27), and 5 years (n=18) after surgery. Among the study group, 4 (12.3%) patients experienced ILR or new carcinomas after 6-13 years, the same number (n=4) had metastatic dissemination after 3-7 years. These patients are still alive and disease-free after 14-17 years of follow-up. The rate of recurrences and metastasis in the controls were not significantly different. The findings provide evidence that BCS in the first trimester PrBC is feasible and reasonably safe for both the mother and the baby.

14.
BJOG ; 128(13): 2084-2090, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34403184

RESUMEN

OBJECTIVE: To assess the general population's knowledge regarding the utility and availability of tools to diagnosis endometriosis, with a focus on ultrasound. DESIGN: An international cross-sectional online survey study was performed between August and October 2019. SETTING AND POPULATION: 5301 respondents, representing 73 countries. METHODS: In all, 23 questions survey focused on knowledge of endometriosis diagnosis distributed globally via patient- and community-endometriosis groups using social media. MAIN OUTCOMES AND MEASURES: Descriptive data of the knowledge of diagnostic tools for diagnosing endometriosis, including details about diagnosis using ultrasound. RESULTS: In all, 84.0% of respondents had been previously diagnosed with endometriosis, 71.5% of whom had been diagnosed at the time of surgery. Ultrasound and MRI were the methods of diagnosis in 6.5% and 1.8%, respectively. A total of 91.8%, 28.8% and 16.6% of respondents believed surgery, ultrasound and MRI could diagnose endometriosis, respectively (more than one answer allowed). In those diagnosed by surgery, 21.7% knew about ultrasound as a diagnosis method, whereas in those diagnosed non-surgically, 51.5% knew (P < 0.001). In all, 14.7%, 31.1% and 18.2% stated superficial, ovarian and deep endometriosis could be diagnosed with ultrasound (32.9% stated they did not know which phenotypes of endometriosis could be diagnosed). Lastly, 58.4% of respondents do not believe they could access an advanced ultrasound in their region. CONCLUSIONS: There is a limited appreciation for the role of non-surgical diagnostic tests for endometriosis among lay respondents to this survey. TWEETABLE ABSTRACT: International survey shows limited awareness of lay respondents about non-surgical endometriosis diagnostic tools.


Asunto(s)
Endometriosis/diagnóstico por imagen , Conocimientos, Actitudes y Práctica en Salud , Imagen por Resonancia Magnética/métodos , Dolor Pélvico/etiología , Ultrasonografía/métodos , Adulto , Estudios Transversales , Femenino , Humanos , Persona de Mediana Edad , Dolor Pélvico/diagnóstico por imagen , Encuestas y Cuestionarios
15.
Rev Sci Instrum ; 92(5): 054504, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243263

RESUMEN

In the last few decades, much effort has been made for the production of squeezed vacuum states in order to reduce quantum noise in the audio-frequency band. This technique has been implemented in all running gravitational-wave interferometric detectors and helped to improve their sensitivity. While the detectors are acquiring data for astrophysical observations, they must be kept in the operating condition, also called "science mode," that is, a state that requires the highest possible duty-cycle for all the instrumental parts and controls. We report the development of a highly automated setup for the generation of optical squeezed states, where all the required control loops are supervised by a software based on finite state machines; we took special care to grant ease of use, stability of operation, and possibility of auto-recovery. Moreover, the setup has been designed to be compatible with the existing software and hardware infrastructure of the Virgo detector. In this paper, we discuss the optical properties of this squeezing setup, the locking techniques, and the automation algorithms.

16.
Med Vet Entomol ; 35(4): 658-662, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34268793

RESUMEN

Seals (Phocidae) undergo an annual cycle of moulting that implies hair regeneration, and in the case of southern elephant seals, it also involves the superficial strata of the epidermis. Therefore, surviving the moulting period is crucial for their obligate and permanent ectoparasites. Throughout evolutionary time, sucking lice (Echinophtiriidae) have developed morphological, behavioural and ecological adaptations to cope with the amphibious lifestyle of their hosts. Lepidophthirus macrorhini, the Southern elephant seal louse species, faces the additional challenge of surviving attached to the host during the moulting period. Since lice live on the skin, L. macrorhini has developed a unique survival strategy by piercing the skin of their host, thus keeping them protected from moulting. During fieldwork in Patagonia and Antarctica, skin samples with lice within were collected for histological analysis to assess whether these parasites caused damage to the host. Lice generate an inflammatory process in the host's dermis, and these lesions could alter the normal chemical and mechanical protective properties of the skin facilitating secondary infections. Further studies that analyse the potential pathogens in those skin lesions are necessary to properly assess the real impact of ectoparasites on their host health.


Asunto(s)
Anoplura , Phocidae , Animales , Muda , Phocidae/parasitología , Phocidae/fisiología , Piel
17.
Clin. transl. oncol. (Print) ; 23(7): 1415-1428, jul. 2021. ilus
Artículo en Inglés | IBECS | ID: ibc-221982

RESUMEN

Aims To report toxicity of a hypofractionated scheme of whole-breast (WB) intensity-modulated radiotherapy (IMRT) with simultaneous integrated boost (SIB) to the tumor bed (TB) using Tomotherapy® with Direct modality. Methods Patients with early breast cancer, undergoing radiotherapy (RT) in 15 daily fractions to WB (prescription dose 40.05 Gy) and SIB to the TB (48 Gy), between 2013 and 2017, was analyzed. Primary endpoint was acute and intermediate toxicity assessed at the end and within 6 months from RT, according to Radiation Therapy Oncology Group (RTOG) scale. Secondary endpoints included early chronic toxicity at 12-months follow-up, using the Late Effects Normal Tissue Task Subjective, Objective, Management, and Analytic (LENT-SOMA) scale, and cosmesis using Harvard criteria. Results The study population was of 287 patients. Acute and intermediate toxicity was collected among 183 patients with data available at the end of RT and within 6 months, 85 (46%) experienced G2 toxicity and 84 (46%) G1 toxicity, while 14 (8%) did not report toxicity at any time. A significant reduction of any grade toxicity was observed between the two time points, with the majority of patients reporting no clinically relevant toxicity at 6 months. At univariate analysis, age < 40 years, breast volume > 1000 cm3 and Dmax ≤ 115% of prescription dose were predictive factors of clinically relevant acute toxicity (G ≥ 2) at any time. At multivariable analysis, only age and breast volume were confirmed as predictive factors, with Relative Risks (95% Confidence Intervals): 2.02 (1.13–3.63) and 1.84 (1.26–2.67), respectively. At 12-month follow-up, 113 patients had complete information on any toxicity with 53% of toxicity G < 2, while cosmetic evaluation, available for 102 patients, reported a good–excellent result for 86% of patients (AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Neoplasias de la Mama/radioterapia , Hipofraccionamiento de la Dosis de Radiación , Radioterapia de Intensidad Modulada , Enfermedad Aguda , Factores de Tiempo , Estudios Prospectivos , Neoplasias de la Mama/patología , Dosis de Radiación , Traumatismos por Radiación
19.
Ultrasound Obstet Gynecol ; 58(6): 933-939, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34182605

RESUMEN

OBJECTIVE: To investigate the agreement of measurements of the three diameters of rectosigmoid deep endometriosis (DE) lesions between presurgical evaluation using transvaginal sonography (TVS) and postsurgical specimen measurement (PSM). METHODS: This was a prospective observational multicenter study including symptomatic women undergoing surgical treatment for DE involving the rectosigmoid, by either discoid or segmental resection, from April 2017 to December 2019. TVS was performed presurgically to evaluate lesion size (craniocaudal-midsagittal length, anteroposterior thickness and transverse diameter), in accordance with the International Deep Endometriosis Analysis (IDEA) group consensus statement, and was compared with PSM. The agreement of lesion dimensions between the two methods was assessed by Bland-Altman plots and limits of agreement and additionally by the intraclass correlation coefficient (ICC) and Pearson's correlation coefficient. Systematic and proportional bias was assessed using the paired t-test. RESULTS: A total of 207 consecutive women were eligible for inclusion. Forty-one women were excluded, leaving 166 women for final analysis. A total of 123 segmental resections and 46 discoid resections were performed (both procedures were performed in three women). The mean difference between TVS and PSM was 0.90 (95% CI, 0.85-0.95) mm for lesion length measurements, 1.03 (95% CI, 0.98-1.09) mm for lesion thickness measurements and 0.84 (95% CI, 0.79-0.89) mm for transverse diameter measurements. Bland-Altman analysis demonstrated good agreement between the two methods for measurements of lesion length. Furthermore, there was good reliability and correlation between TVS and PSM for lesion length measurements, as demonstrated by an ICC of 0.82 (95% CI, 0.75-0.87) and Pearson's correlation coefficient of 0.72 (95% CI, 0.62-0.80), moderate-to-good reliability and correlation for lesion thickness measurements, with an ICC of 0.76 (95% CI, 0.67-0.82) and Pearson's correlation coefficient of 0.61 (95% CI, 0.51-0.70), and poor-to-moderate reliability and correlation for transverse diameter measurements, with an ICC of 0.58 (95% CI, 0.39-0.71) and Pearson's correlation coefficient of 0.46 (95% CI, 0.33-0.58). CONCLUSION: Preoperative TVS determines accurately rectosigmoid DE lesion length. TVS can thereby contribute to optimal planning of surgical treatment options in women with rectosigmoid DE. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Endometriosis/diagnóstico por imagen , Enfermedades del Recto/diagnóstico por imagen , Enfermedades del Sigmoide/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Colon Sigmoide/diagnóstico por imagen , Colon Sigmoide/patología , Femenino , Humanos , Estudios Prospectivos , Recto/diagnóstico por imagen , Recto/patología , Reproducibilidad de los Resultados , Vagina/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...