Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
2.
J Clin Med ; 13(2)2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38256506

RESUMEN

In the past two decades, transcatheter aortic valve replacement (TAVR) has transformed the management of aortic stenosis and has become the standard of care regardless of surgical risk levels. Advances in transcatheter valve design across newer generations, improved imaging, greater operator expertise, and technical enhancements have collectively contributed to increased safety and a decline in procedural complications over this timeframe. The application of TAVR has progressively expanded to include younger patients with lower risks, who have longer life expectancies. This article offers an up-to-date review of the latest innovations in transcatheter delivery systems, devices, and its possible future indications.

4.
Circulation ; 149(6): 417-426, 2024 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-37970713

RESUMEN

BACKGROUND: Tools for mortality prediction in patients with the severe hypercholesterolemia phenotype (low-density lipoprotein cholesterol ≥190 mg/dL) are limited and restricted to specific racial and ethnic cohorts. We sought to evaluate the predictors of long-term mortality in a large racially and ethnically diverse US patient cohort with low-density lipoprotein cholesterol ≥190 mg/dL. METHODS: We conducted a retrospective analysis of all patients with a low-density lipoprotein cholesterol ≥190 mg/dL seeking care at Montefiore from 2010 through 2020. Patients <18 years of age or with previous malignancy were excluded. The primary end point was all-cause mortality. Analyses were stratified by age, sex, and race and ethnicity. Patients were stratified by primary and secondary prevention. Cox regression analyses were used to adjust for demographic, clinical, and treatment variables. RESULTS: A total of 18 740 patients were included (37% non-Hispanic Black, 30% Hispanic, 12% non-Hispanic White, and 2% non-Hispanic Asian patients). The mean age was 53.9 years, and median follow-up was 5.2 years. Both high-density lipoprotein cholesterol and body mass index extremes were associated with higher mortality in univariate analyses. In adjusted models, higher low-density lipoprotein cholesterol and triglyceride levels were associated with an increased 9-year mortality risk (adjusted hazard ratio [HR], 1.08 [95% CI, 1.05-1.11] and 1.04 [95% CI, 1.02-1.06] per 20-mg/dL increase, respectively). Clinical factors associated with higher mortality included male sex (adjusted HR, 1.31 [95% CI, 1.08-1.58]), older age (adjusted HR, 1.19 per 5-year increase [95% CI, 1.15-1.23]), hypertension (adjusted HR, 2.01 [95% CI, 1.57-2.57]), chronic kidney disease (adjusted HR, 1.68 [95% CI, 1.36-2.09]), diabetes (adjusted HR, 1.79 [95% CI, 1.50-2.15]), heart failure (adjusted HR, 1.51 [95% CI, 1.16-1.95]), myocardial infarction (adjusted HR, 1.41 [95% CI, 1.05-1.90]), and body mass index <20 kg/m2 (adjusted HR, 3.36 [95% CI, 2.29-4.93]). A significant survival benefit was conferred by lipid-lowering therapy (adjusted HR, 0.57 [95% CI, 0.42-0.77]). In the primary prevention group, high-density lipoprotein cholesterol <40 mg/dL was independently associated with higher mortality (adjusted HR, 1.49 [95% CI, 1.06-2.09]). Temporal trend analyses showed a reduction in statin use over time (P<0.001). In the most recent time period (2019-2020), 56% of patients on primary prevention and 85% of those on secondary prevention were on statin therapy. CONCLUSIONS: In a large, diverse cohort of US patients with the severe hypercholesterolemia phenotype, we identified several patient characteristics associated with increased 9-year all-cause mortality and observed a decrease in statin use over time, in particular for primary prevention. Our results support efforts geared toward early recognition and consistent treatment for patients with severe hypercholesterolemia.


Asunto(s)
Inhibidores de Hidroximetilglutaril-CoA Reductasas , Hipercolesterolemia , Humanos , Masculino , Persona de Mediana Edad , Hipercolesterolemia/tratamiento farmacológico , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Estudios Retrospectivos , LDL-Colesterol , HDL-Colesterol , Fenotipo , Factores de Riesgo
6.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37933728

RESUMEN

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Angiografía Coronaria/métodos
7.
Catheter Cardiovasc Interv ; 102(6): 1020-1033, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855169

RESUMEN

BACKGROUND: Diabetic patients are at higher risk of recurrent adverse events following percutaneous coronary intervention (PCI) than the nondiabetics. Despite the introduction of new generation drug-eluting stents, their efficacy in the diabetics is still limited. AIMS: To evaluate the efficacy of the Abluminus DES+ biodegradable polymer sirolimus-eluting stent in reducing neointimal hyperplasia in diabetic patients, compared to a durable polymer everolimus-eluting stent (DP-EES). METHODS: A total of 131 patients with diabetes and coronary artery disease were enrolled in six Italian centers and randomized in a 2:1 fashion to PCI with Abluminus DES+ or DP-EES: 85 were assigned to Abluminus DES+ and 46 to DP-EES. The primary endpoint was optimal coherence tomography (OCT)-derived neointimal volume at 9-12 months. Secondary endpoints included OCT-derived neointimal area, neointimal volume obstruction and adverse clinical events. RESULTS: The primary endpoint, neointimal volume, did not differ between Abluminus DES+ and DP-EES (29.11 ± 18.90 mm3 vs. 25.48 ± 17.04 mm3 , p = 0.40) at 9-12-month follow-up. This finding remained consistent after weighing for the sum of stents lengths (1.14 ± 0.68 mm3 vs. 0.99 ± 0.74 mm3 for Abluminus DES+ and DP-EES, respectively, p = 0.38). Similarly, other OCT-derived and clinical secondary endpoints did not significantly differ between the two groups. Rate of target lesion failure was high in both groups (21.2% for Abluminus DES+ and 19.6% for DP-EES). CONCLUSIONS: This preliminary study failed to demonstrate the superiority of the Abluminus DES+ over the DP-EES in diabetic patients in terms of neointimal proliferation.


Asunto(s)
Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Implantes Absorbibles , Everolimus/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Sirolimus/efectos adversos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
9.
Circ Cardiovasc Interv ; 16(12): e013232, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37874646

RESUMEN

BACKGROUND: Drug-coated balloons (DCB) are an emerging tool for modern percutaneous coronary intervention (PCI), but evidence on their use for de novo lesions on large vessels is limited. METHODS: Consecutive patients undergoing DCB-based PCI on the left anterior descending artery in 2 Italian centers from 2018 to 2022 were retrospectively enrolled and compared with patients who received left anterior descending PCI with contemporary drug-eluting stents (DES). In-stent restenosis was excluded. The DCB group included both patients undergoing DCB-only PCI and those receiving hybrid PCI with DCB and DES combined. The primary end point was target lesion failure at 2 years, defined as the composite of target lesion revascularization, cardiac death, and target vessel myocardial infarction. RESULTS: We included 147 consecutive patients undergoing DCB-based treatment on the left anterior descending artery and compared them to 701 patients who received conventional PCI with DES. In the DCB group, 43 patients (29.2%) were treated with DCB only and 104 (70.8%) with a hybrid approach; DCB length was greater than stent length in 55.1% of cases. Total treated length was higher in the DCB group (65 [40-82] versus 56 [46-66] mm; P=0.002), while longer DESs were implanted (38 [24-62] versus 56 [46-66] mm; P<0.001) and a higher rate of large vessels were treated (76.2% versus 83.5%; P=0.036) in the DES cohort. The cumulative 2-year target lesion failure incidence was not significantly different between the 2 groups (DCB, 4.1% versus DES, 9.8%; hazard ratio, 0.51 [95% CI, 0.20-1.27]; P=0.15). After a 1:1 propensity score matching resulting in 139 matched pairs, the DCB-based treatment was associated with a lower risk for target lesion failure at 2 years compared with DES-only PCI (hazard ratio, 0.2 [95% CI, 0.07-0.58]; P=0.003), mainly driven by less target lesion revascularization. CONCLUSIONS: A DCB-based treatment approach for left anterior descending revascularization allows a significantly reduced stent burden, thereby potentially limiting target lesion failure risk at midterm follow-up.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Stents Liberadores de Fármacos/efectos adversos , Resultado del Tratamiento , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Vasos Coronarios/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Materiales Biocompatibles Revestidos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia
10.
Catheter Cardiovasc Interv ; 102(5): 896-899, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37746918

RESUMEN

Despite improvements in current devices and techniques for complex chronic total occlusion (CTO) percutaneous coronary intervention (PCI), procedural complications, including coronary perforation, still occur and could be life-threatening. A patient with a history of multivessel coronary artery disease and a CTO of the right coronary artery (RCA) underwent successful retrograde crossing of an RCA CTO. After wiring the CTO body and lesion dilatation, a drug-eluting stent was implanted in the distal RCA toward the posterior descending artery. A large Ellis type III perforation occurred at the distal edge of the stent. Septal crossing with a balloon and tamponade of the perforation site through the retrograde collaterals followed, as the RCA was not suitable to accommodate easily both the covered stent and the balloon simultaneously. This case report presents a novel approach the "septal retrograde ping-pong" technique, which demonstrates successful treatment of coronary perforations by utilizing a retrograde approach through a septal collateral. This technique proves to be effective in situations where the conventional antegrade balloon or covered stent delivery methods are not feasible or unsuccessful. This innovative approach offers a promising alternative for managing challenging cases of coronary perforations, providing new insights and potential solutions for interventional cardiologists.


Asunto(s)
Oclusión Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Angiografía Coronaria , Resultado del Tratamiento , Circulación Colateral , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Enfermedad Crónica
12.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668097

RESUMEN

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Diseño de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
13.
J Interv Cardiol ; 2023: 7958808, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37560012

RESUMEN

Background: In the setting of coronary artery dissection, both spontaneous and iatrogenic, fixing the intimal tear, usually with stent implantation, can be extremely challenging if the distal wire position has been lost. Common complications are mainly related to the inadvertent subintimal tracking of the guidewire while attempting to gain the distal true lumen. Aims: To report the registry results of using the SUOH 0.3 guidewire for managing coronary artery dissection in a real-world multicenter setting. Methods: The study population in this retrospective, multicenter, international registry included 75 consecutive patients who underwent PCI and required an antegrade wiring of a dissected coronary artery. Results: Successful use of SUOH 0.3 was achieved in 69 (92%) patients. The use of a microcatheter was associated with a significantly higher rate of TIMI 3 flow at the end of the procedure (no microcatheter: n = 17, 81%; microcatheter: n = 52, 96.3%; p = 0.017). The first recanalization attempt was made with the SUOH 03 guidewire in 48 (64%) cases, and it was successful in 42 (87%). The overall PCI success rate was reported in 72 (96%) patients, with no significant differences among patients with different origins, mechanisms, and locations of dissection. Conclusions: In this setting, the SUOH 0.3 guidewire provides high procedural success without additional complex techniques.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Oclusión Coronaria/etiología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Estudios Retrospectivos , Angiografía Coronaria , Enfermedad Crónica , Sistema de Registros
14.
JACC Cardiovasc Interv ; 16(9): 1081-1091, 2023 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-37164607

RESUMEN

BACKGROUND: Long-term right ventricular pacing (VP) has been related to negative left ventricular remodeling and heart failure (HF), but there is a lack of evidence regarding the prognostic impact on transcatheter aortic valve replacement (TAVR) patients. OBJECTIVES: The aim of the PACE-TAVI registry is to evaluate the association of high percentage of VP with adverse outcomes in patients with pacemaker implantation after TAVR. METHODS: PACE-TAVI is an international multicenter registry of all consecutive TAVR patients who underwent permanent pacemaker implantation for conduction disturbances in the first 30 days after the procedure. Patients were divided into 2 subgroups according to the percentage of VP (<40% vs ≥40%) at pacemaker interrogation. The primary endpoint was the composite of cardiovascular mortality or hospitalization for HF. RESULTS: A total of 377 patients were enrolled, 158 with VP <40% and 219 with VP ≥40%. After multivariable adjustment, VP ≥40% was associated with a higher incidence of the primary endpoint (HR: 2.76; 95% CI: 1.39-5.51; P = 0.004), first HF hospitalization (HR: 3.37; 95% CI: 1.50-7.54; P = 0.003), and cardiovascular death (HR: 3.77; 95% CI: 1.02-13.88; P = 0.04), while the incidence of all-cause death was not significantly different (HR: 2.17; 95% CI: 0.80-5.90; P = 0.13). Patients with VP ≥ 40% showed a higher New York Heart Association functional class both at 1 year (P = 0.009) and at last available follow-up (P = 0.04) and a nonsignificant reduction of left ventricular ejection fraction (P = 0.18) on 1-year echocardiography, while patients with VP <40% showed significant improvement (P = 0.009). CONCLUSIONS: In TAVR patients undergoing permanent pacemaker implantation, a high percentage of right VP at follow-up is associated with an increased risk for cardiovascular death and HF hospitalization. These findings suggest the opportunity to minimize right VP through dedicated algorithms in post-TAVR patients without complete atrioventricular block and to evaluate a more physiological VP modality in patients with persistent complete atrioventricular block.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Volumen Sistólico , Estimulación Cardíaca Artificial/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Función Ventricular Izquierda , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
15.
Expert Opin Drug Deliv ; 20(5): 689-701, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37203200

RESUMEN

INTRODUCTION: Onyx FrontierTM represents the latest iteration within the family of zotarolimus-eluting stents (ZES), designed for the treatment of coronary artery disease. Approval by the Food and Drug Administration was granted in May 2022, and Conformité Européenne marking followed in August 2022. AREAS COVERED: We hereby review the principal design features of Onyx Frontier, highlighting differences and similarities with other currently available drug-eluting stents. In addition, we focus on the refinements of this newest platform as compared with previous ZES versions, including the attributes yielding its exceptional crossing profile and deliverability. The clinical implications related to both its newest and inherited characteristics will be discussed. EXPERT OPINION: The nuances of the latest Onyx Frontier, together with the continuous refinement previously witnessed throughout the development of ZES, lead to a latest generation device ideal for a diverse spectrum of clinical and anatomical scenarios. In particular, its peculiarities will be of benefit in the settings often offered by a progressively aging population, such as high bleeding risk patients and complex coronary lesions.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Anciano , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia , Tecnología , Intervención Coronaria Percutánea/efectos adversos
16.
Am J Cardiol ; 198: 1-8, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37182254

RESUMEN

Debulking lesions with severe coronary artery calcification (CAC) is highly recommended to obtain good procedural and long-term success. Utilization and performance of coronary intravascular lithotripsy (IVL) after rotational atherectomy (RA) has not been thoroughly studied. This study aimed to evaluate the efficacy and safety of IVL with the Shockwave Coronary Rx Lithotripsy System in lesions with severe CAC as elective or bail-out strategy after RA. This observational, prospective, single-arm, multicenter, international, open-label Rota-Shock registry included patients with symptomatic coronary artery disease and lesions with severe CAC treated by percutaneous coronary intervention, including lesion preparation with RA and IVL, at 23 high-volume centers. Primary efficacy end point was procedural success, defined as final diameter stenosis <30% by quantitative coronary angiography. Primary safety end point was freedom from serious angiographic complications, which included >National Heart, Lung and Blood Institute type B dissection, perforation, abrupt closure, slow or no flow, final thrombolysis in myocardial infarction flow <3, and acute thrombosis. A total of 160 patients were enrolled between June 2020 and June 2022. The primary efficacy end point was observed in 155 patients (96.9%). The primary safety end point occurred in 145 cases (90.6%). Dissections >National Heart, Lung and Blood Institute type B occurred in 3 patients (1.9%), whereas slow or no flow occurred in 8 (5.0%), final thrombolysis in myocardial infarction flow <3 in 3 (1.9%), and perforation in 4 patients (2.5%). Free from inhospital major adverse cardiac and cerebrovascular events, including cardiac death, target vessel myocardial infarction, target lesion revascularization, cerebrovascular accident, definite/probable stent thrombosis, and major bleeding, occurred in 158 patients (98.7%). In conclusion, IVL after RA in lesions with severe CAC was effective and safe, with a very low incidence of complications as either elective or bail-out strategy.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Litotricia , Infarto del Miocardio , Trombosis , Calcificación Vascular , Humanos , Aterectomía Coronaria/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Calcificación Vascular/cirugía , Enfermedad de la Arteria Coronaria/terapia , Infarto del Miocardio/epidemiología , Angiografía Coronaria , Trombosis/etiología , Litotricia/efectos adversos , Sistema de Registros
17.
Eur Heart J Suppl ; 25(Suppl C): C96-C105, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125294

RESUMEN

Chronic total occlusion (CTO) interventions are among the most complex procedures within the panorama of percutaneous coronary intervention (PCI). Awareness of potential complications, adequate procedural planning in order to avoid them, and prompt recognition and management should any occur are at the cornerstone of a successful CTO programme. Complications can be acute or late after the procedure and can be cardiac or non-cardiac. Acute cardiac complications can occur directly at the coronary artery level or can have other strictly non-coronary manifestations, such as hypotension, myocardial infarction, arrhythmias, or tamponade. In this review, we focus on acute coronary complications of CTO PCI, in particular their causes, prevention, and management strategies.

18.
JACC Case Rep ; 12: 101776, 2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37091051

RESUMEN

Patients with tricuspid regurgitation are often referred late in their disease course and present with volume overload, which is a detrimental factor leading to right-sided chamber dilatation and dysfunction. Treatment of volume overload can 1) improve patient functional status; 2) avoid repeated invasive examinations; and 3) establish eligibility for transcatheter tricuspid intervention. (Level of Difficulty: Intermediate.).

20.
Catheter Cardiovasc Interv ; 101(5): 911-917, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36856010

RESUMEN

BACKGROUND: Chronic total occlusion (CTO) revascularization is a major source of radiation for both patients and physicians. Therefore, efforts to minimize radiation during CTO percutaneous coronary intervention (PCI) are highly encouraged. AIMS: To evaluate the impact of an Ultra Low fluoroscopic Dose Protocol (ULDP), based on 3.75 frames per second for the fluoroscopy and 7.5 frames per second for the cine acquisition, during CTO PCI. METHODS: One hundred fifty consecutive patients who underwent CTO PCI were retrospectively enrolled. Eighty-five underwent standard dose protocol (SDP) and 65 ULDP. Radiation exposure and acute clinical outcomes were compared between groups. Results were stratified according to lesion complexity. RESULTS: Patients undergoing ULDP, as compared to those undergoing SDP, showed a significant reduction of kerma area product, both for simple lesions (6861.0 vs. 13236.0 mGy × cm2 ; p = 0.014) and complex lesions (CL) (8865.0 vs. 16618.0 mGy × cm2 ; p < 0.001). Similarly, Air Kerma (AK) was lower when ULDP was used (1222.5 vs. 2015.0 cGy in SL, p = 0.134; 1499.0 vs. 2794.0 cGy in CL, p < 0.001). No significant differences were reported regarding procedural success and in-hospital major adverse cardiovascular events between groups. Notably, there was not any crossover from ULDO to SDP due to poor quality images. Interestingly, fluoroscopy time, procedural time and contrast volume was significantly lower in patients undergoing ULDP only for CLs. CONCLUSIONS: ULDP significantly reduces radiation exposure in the setting of high complexity procedures such as CTO PCI. This reduction seemed to be greater with increased procedural complexity and did not impact acute success or adverse clinical events.


Asunto(s)
Oclusión Coronaria , Fluoroscopía , Intervención Coronaria Percutánea , Humanos , Enfermedad Crónica , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Oclusión Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...