Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
3.
Artículo en Inglés | MEDLINE | ID: mdl-38532517

RESUMEN

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.

5.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38224255

RESUMEN

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de Registros
6.
Artículo en Inglés | MEDLINE | ID: mdl-37951484

RESUMEN

An increasing number of patients experience late valvular disease after heart transplantation (HTx). While mostly being primarily addressed through surgical interventions, transcatheter valve procedures to treat these conditions are rising, particularly for unsuitable surgical candidates. This review aims at analyzing the outcomes of transcatheter valvular procedures in this subset of patients. A systematic review was conducted including studies reporting on adult patients requiring any form of transcatheter valvular intervention after a previous HTx. Studies involving a surgical approach, heterotopic heart transplants, or concomitant procedures performed during the transplant itself were excluded. Twenty-five articles with a total of 33 patients met the inclusion criteria, 10 regarding the aortic valve (14 patients), 5 the mitral valve (6 patients), and 6 the tricuspid valve (13 patients). In two cases, the procedure was recommended to stabilize the valvular lesion before re-transplantation, as both were very young patients. Overall, the mean time from heart transplantation to reintervention was 14.7 ± 9.5 years. The mean follow-up was 15.5 ± 13.5 months, and only one patient died 22.3 months after the intervention. There is a growing emergence of transcatheter interventions for valvular disease after heart transplantation, especially in cases where surgery is deemed high-risk or prohibitive. A different strategy may also be considered in young patients to permit longer allograft life before later re-transplantation. Although encouraging outcomes have been documented, additional research is required to establish the most appropriate approach within this specific subset of patients.

7.
Cureus ; 15(9): e45648, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37868418

RESUMEN

A 75-year-old female patient was referred to our institution for severe symptomatic low-flow low-gradient aortic valve stenosis and tricuspid valve regurgitation (TR) associated with heart failure. After multidisciplinary discussion, the patient was scheduled for one-stage totally percutaneous treatment of her valve lesions by transcatheter aortic valve implantation (TAVI) and transcatheter edge-to-edge tricuspid valve repair (TEER) through transfemoral access. The patient had an uneventful hospital stay and was discharged home on the third postoperative day. During the following 24 months, the patient did well with regression of her heart failure signs and symptoms.

8.
Cureus ; 15(9): e45848, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37881383

RESUMEN

Tricuspid regurgitation is a frequent condition that is linked to an elevated risk of cardiovascular events and significant mortality but is often overshadowed by left-sided valve diseases. Isolated surgical tricuspid valve surgery is still considered a high-risk surgery, and over recent years, various transcatheter procedures for tricuspid treatment have emerged as an alternative solution. Among the available transcatheter procedures, the EVOQUE system's transcatheter tricuspid valve replacement could potentially offer a solution, especially in patients considered non-eligible for transcatheter edge-to-edge tricuspid valve repair. We present a case report of an octogenarian patient considered at prohibitive risk for conventional surgery and not eligible for transcatheter edge-to-edge repair who was eventually treated with a transfemoral transcatheter tricuspid 52-mm EVOQUE valve implantation. Postprocedural recovery and follow-up at 18 months were uneventful, with a well-functioning tricuspid valve bioprosthesis.

9.
Front Cardiovasc Med ; 10: 1227217, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37645516

RESUMEN

Background: A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume. Aims: The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe. Materials and methods: Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice. Results: Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%). Conclusion: Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.

10.
Eur J Cardiothorac Surg ; 64(2)2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37410123

RESUMEN

OBJECTIVES: The aim of this study was to investigate the impact of Valve Academic Research Consortium 3 minor access site vascular complications (VCs) in patients who underwent percutaneous transfemoral (TF) transcatheter aortic valve implantation (TAVI). METHODS: This single-centre retrospective study included consecutive patients who underwent percutaneous TF-TAVI from 2009 to 2021. A propensity score-matched analysis was performed to compare early and long-term clinical results between patients with VC and without VC (nVC). RESULTS: A total of 2161 patients were included, of whom 284 (13.1%) experienced access site VC. Propensity score analysis allowed to match 270 patients from the VC group with 727 patients from the nVC group. In the matched cohorts, the VC group showed longer operative times (63.5 vs 50.0 min, P < 0.001), higher operative and in-hospital mortality (2.6% vs 0.7%, P = 0.022; and 6.3% vs 3.2%, P = 0.040, respectively), longer hospital length of stay (8 vs 7 days, P = 0.001) and higher rates of blood transfusion (20.4% vs 4.3%, P < 0.001) and infectious complications (8.9% vs 3.8%, P = 0.003). Overall survival during follow-up was significantly lower in the VC group (hazard ratio 1.37, 95% CI 1.03-1.82, P = 0.031) with 5-year survival rates being 58.0% (95% CI 49.5-68.0%) and 70.7% (95% CI 66.2-75.5%) for the VC and nVC groups, respectively. CONCLUSIONS: This retrospective study observed that minor access site VCs during percutaneous TF-TAVI can be serious events affecting early and long-term outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades Cardiovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Enfermedades Cardiovasculares/cirugía , Válvula Aórtica/cirugía , Arteria Femoral/cirugía
11.
Arch Cardiovasc Dis ; 116(6-7): 352-356, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37391341

RESUMEN

Structural heart interventions are steadily increasing, and the majority requires echocardiographic guidance. As a result, imaging specialists are exposed to the harmful effects of scattered ionizing radiation. This X-ray exposure must be quantified, its potential consequences should be monitored by occupational medicine and the "as low as reasonably achievable" principles of radioprotection should be optimized (including increasing the distance, decreasing the duration, using shielding radiation and providing safety training for the imaging specialist). The spatial organization of and shielding provision in the procedural rooms should be designed to optimize radioprotection for all team members.


Asunto(s)
Exposición a la Radiación , Traumatismos por Radiación , Protección Radiológica , Humanos , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Protección Radiológica/métodos , Ecocardiografía , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control
13.
EuroIntervention ; 19(6): 502-511, 2023 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-37203860

RESUMEN

BACKGROUND: Prospective data about transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) patients are limited. AIMS: We aimed to evaluate the clinical impact of the Evolut PRO and R (34 mm) self-expanding prostheses in BAV patients and explore the impact of different computed tomography (CT) sizing algorithms in a prospective registry. METHODS: A total of 149 bicuspid patients were treated in 14 countries. The primary endpoint was the intended valve performance at 30 days. Secondary endpoints were 30-day and 1-year mortality, severe patient-prosthesis mismatch (PPM) and the ellipticity index at 30 days. All study endpoints were adjudicated according to Valve Academic Research Consortium 3 criteria. RESULTS: The mean Society of Thoracic Surgeons score was 2.6% (1.7-4.2). Type I L-R BAV was observed in 72.5% of the patients. Evolut valve sizes 29 and 34 mm were utilised in 49.0% and 36.9% of the cases, respectively. The 30-day cardiac death rate was 2.6%; the 1-year cardiac death rate was 11.0%. Valve performance at 30 days was observed in 142/149 (95.3%) patients. The mean aortic valve area post-TAVI was 2.1 (1.8-2.6) cm2, and the mean aortic gradient was 7.2 (5.4-9.5) mmHg. No patient had more than moderate aortic regurgitation at 30 days. PPM was observed in 13/143 (9.1%) surviving patients and was severe in 2 patients (1.6%). Valve function was maintained at 1 year. The mean ellipticity index remained 1.3 (interquartile range 1.2-1.4). Overall, 30-day and 1-year clinical and echocardiography outcomes were similar between the two sizing strategies. CONCLUSIONS: BIVOLUTX demonstrated a favourable bioprosthetic valve performance and good clinical outcomes after TAVI with the Evolut platform in patients with bicuspid aortic stenosis. No impact from the sizing methodology could be identified.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Enfermedad de la Válvula Aórtica Bicúspide/etiología , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Constricción Patológica , Resultado del Tratamiento , Diseño de Prótesis , Estudios Prospectivos , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Mitral/cirugía , Sistema de Registros , Muerte
14.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-37225288

RESUMEN

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Sistema de Registros
15.
JACC Case Rep ; 7: 101711, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36776792

RESUMEN

We developed humanized biosimulator to predict the risk of coronary obstruction among high-risk patients undergoing valve-in-valve (ViV) procedures. In this case, based on unchanged instantaneous wave-free ratio values measured during a ViV simulation session, the procedure was performed safely in the patient the day afterward, without coronary artery issues and with good hemodynamic results. (Level of Difficulty: Advanced.).

18.
J Clin Med ; 11(20)2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-36294438

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is the preferred treatment for symptomatic severe aortic stenosis (AS) in a majority of patients across all surgical risks. PATIENTS AND METHODS: Paravalvular leak (PVL) and patient-prosthesis mismatch (PPM) are two frequent complications of TAVI. Therefore, based on the large France-TAVI registry, we planned to report the incidence of both complications following TAVI, evaluate their respective risk factors, and study their respective impacts on long-term clinical outcomes, including mortality. RESULTS: We identified 47,494 patients in the database who underwent a TAVI in France between 1 January 2010 and 31 December 2019. Within this population, 17,742 patients had information regarding PPM status (5138 with moderate-to-severe PPM, 29.0%) and 20,878 had information regarding PVL (4056 with PVL ≥ 2, 19.4%). After adjustment, the risk factors for PVL ≥ 2 were a lower body mass index (BMI), a high baseline mean aortic gradient, a higher body surface area, a lower ejection fraction, a smaller diameter of TAVI, and a self-expandable TAVI device, while for moderate-to-severe PPM we identified a younger age, a lower BMI, a larger body surface area, a low aortic annulus area, a low ejection fraction, and a smaller diameter TAVI device (OR 0.85; 95% CI, 0.83-0.86) as predictors. At 6.5 years, PVL ≥ 2 was an independent predictor of mortality and was associated with higher mortality risk. PPM was not associated with increased risk of mortality. CONCLUSIONS: Our analysis from the France-TAVI registry showed that both moderate-to-severe PPM and PVL ≥ 2 continue to be frequently observed after the TAVI procedure. Different risk factors, mostly related to the patient's anatomy and TAVI device selection, for both complications have been identified. Only PVL ≥ 2 was associated with higher mortality during follow-up.

20.
Am J Cardiol ; 172: 109-114, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35351287

RESUMEN

Ventricular septal myectomy (SM) and alcohol septal ablation (ASA), 2 septal reduction therapies (SRTs), are recommended in symptomatic obstructive hypertrophic cardiomyopathy (HCM) despite maximum tolerated medical therapy. Contradictory results between the outcomes of these 2 types of therapies persist to this day. The objective of this study was to compare in-hospital and mid-term outcomes of SM versus ASA, at a nationwide level in France. We collected information on patients who underwent SRT for HCM using the French nationwide Programme de Médicalisation des Systèmes d'Information database between 2010 and 2019. A total of 1,574 patients were identified in the database, including 340 patients in the SM arm and 1,234 patients in the ASA arm. No difference during the median follow-up of 1.3 years between the 2 groups was noted in terms of mortality (adjusted incidence rate ratio 0.687, 95% confidence interval 0.361 to 1.309, p = 0.25). However, there was a significantly lower risk of all-cause stroke (adjusted incidence rate ratio 0.180, 95% confidence interval 0.058 to 0.554, p = 0.003) in the ASA group. In conclusion, in our "real-life" data from France, mortality after SRT in patients with HCM was similar after ASA or SM. Moreover, ASA was more widely used than SM despite European Society of Cardiology guidelines recommendations.


Asunto(s)
Técnicas de Ablación , Cardiomiopatía Hipertrófica , Tabique Interventricular , Técnicas de Ablación/métodos , Cardiomiopatía Hipertrófica/cirugía , Etanol/uso terapéutico , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...