Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
2.
J Vasc Interv Radiol ; 35(8): 1176-1186.e1, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38685469

RESUMEN

PURPOSE: To compare patency and reintervention outcomes after either plain old balloon angioplasty (POBA) or drug-coated balloon angioplasty (DCBA) for venous stenoses after percutaneous arteriovenous fistula (pAVF) creation. MATERIALS AND METHODS: One-hundred ninety-five pAVFs were successfully created during the study period, 141 using Ellipsys and 54 using Wavelinq. After pAVF creation, 95 patients (48.7%) required secondary percutaneous transluminal angioplasty (PTA) with either POBA (n = 55, 58%) or DCBA (n = 40, 42.1%). The most common site for PTA was the juxta-anastomotic segment (75.5%; 74/98). Univariate and multivariate Cox regression analyses were used to compare target lesion primary patency, access circuit primary patency, secondary patency, and reintervention rates in the POBA and DCBA cohorts. RESULTS: Thirty-four of 55 (62%) patients in the POBA cohort and 14 of 40 (35%) patients in the DCBA cohort required reinterventions for pAVF restenosis. Mean number of follow-up days among patients treated with POBA was 1,030.4 (SD ± 342.9) and among those treated with DCBA was 744.4 (SD ± 403.5). The use of POBA compared with DCBA was not associated with target lesion and access circuit primary patency loss in multivariate analysis (hazard ratio [HR], 1.81; 95% CI, 0.93-3.51; P = .080; and HR, 1.77; 95% CI, 0.73-4.28; P = .210, respectively). However, time from fistula creation to the first PTA (days) was statistically significantly associated with both outcomes (HR, 0.997; 95% CI, 0.994-0.999; P = .009; and HR, 0.997; 95% CI, 0.992-0.999; P = .021, respectively). There were no major adverse events. CONCLUSIONS: In this retrospective single-center analysis of pAVFs, considerably more patients who underwent PTA with POBA after pAVF creation required reinterventions compared with PTA using DCBA, although the follow-up time of POBA was longer. In multivariate analysis, no differences were noted in the hazard of patency loss between POBA and DCBA.


Asunto(s)
Angioplastia de Balón , Derivación Arteriovenosa Quirúrgica , Materiales Biocompatibles Revestidos , Oclusión de Injerto Vascular , Grado de Desobstrucción Vascular , Humanos , Femenino , Masculino , Angioplastia de Balón/instrumentación , Angioplastia de Balón/efectos adversos , Derivación Arteriovenosa Quirúrgica/efectos adversos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Estudios Retrospectivos , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Oclusión de Injerto Vascular/fisiopatología , Oclusión de Injerto Vascular/diagnóstico por imagen , Factores de Riesgo , Factores de Tiempo , Diálisis Renal , Diseño de Equipo , Análisis Multivariante , Recurrencia , Modelos de Riesgos Proporcionales , Fármacos Cardiovasculares/administración & dosificación , Fármacos Cardiovasculares/efectos adversos , Dispositivos de Acceso Vascular , Retratamiento , Estimación de Kaplan-Meier
3.
J Osteopath Med ; 122(12): 605-608, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36330769

RESUMEN

The use of vena cava filters (VCF) is a common procedure utilized in the prevention of pulmonary embolism (PE), yet VCFs have some significant and known complications, such as strut penetration and migration. Deep vein thrombosis (DVT) and PE remain a major cause of morbidity and mortality in the United States. It is estimated that as many as 900,000 individuals are affected by these each year with estimates suggesting that nearly 60,000-100,000 Americans die of DVT/PE each year. Currently, the preferred treatment for DVT/PE is anticoagulation. However, if there are contraindications to anticoagulation, an inferior vena cava (IVC) filter can be placed. These filters have both therapeutic and prophylactic indications. Therapeutic indications (documented thromboembolic disease) include absolute or relative contraindications to anticoagulation, complication of anticoagulation, failure of anticoagulation, propagation/progression of DVT during therapeutic anticoagulation, PE with residual DVT in patients with further risk of PE, free-floating iliofemoral IVC thrombus, and severe cardiopulmonary disease and DVT. There are also prophylactic indications (no current thromboembolic disease) for these filters. These include severe trauma without documented PE or DVT, closed head injury, spinal cord injury, multiple long bone fractures, and patients deemed at high risk of thromboembolic disease (immobilized or intensive care unit). Interruption of the IVC with filters has long been practiced and is a procedure that can be performed on an outpatient basis. There are known complications of filter placement, which include filter migration within the vena cava and into various organs, as well as filter strut fracture. This case describes a 66-year-old woman who was found to have a filter migration and techniques that were utilized to remove this filter.


Asunto(s)
Embolia Pulmonar , Filtros de Vena Cava , Trombosis de la Vena , Femenino , Humanos , Anciano , Filtros de Vena Cava/efectos adversos , Embolia Pulmonar/etiología , Embolia Pulmonar/prevención & control , Trombosis de la Vena/etiología , Trombosis de la Vena/cirugía , Trombosis de la Vena/tratamiento farmacológico , Unidades de Cuidados Intensivos , Anticoagulantes/uso terapéutico
4.
J Vasc Interv Radiol ; 33(9): 1101-1106, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35688297

RESUMEN

PURPOSE: To assess percutaneous arteriovenous fistula (pAVF) creation with subsequent brachial vein transposition (BVT) using the WavelinQ endoAVF system. MATERIALS AND METHODS: A pre-existing database was retrospectively reviewed. Nine patients underwent attempted pAVF-BVT creation between December 2017 and November 2021. Study outcomes included technical success, time to maturation, patency rates, adverse events, and secondary interventions. Maturation was defined as a pAVF flow of ≥500 mL/min, outflow vein diameter ≥5 mm, and successful 2-needle cannulations in patients on active hemodialysis (HD). RESULTS: pAVF-BVT creation was technically successful in 8 of 9 patients (89%). Six of 8 created pAVFs remained patent and matured at 4 weeks, subsequently undergoing secondary BVT. Primary patency rates at 6, 12, and 24 months were 37.5%, 12.5%, and 12.5%, respectively. Secondary patency rates at 6, 12, and 24 months were 75%, 37.5%, and 37.5%, respectively. One patient had postprocedural access site bleeding, and 4 required secondary interventions to maintain patency. Two patients with failed pAVFs with BVT were successfully converted to surgical AVFs, probably facilitated by sufficient enlargement of superficial veins following pAVF creation. CONCLUSIONS: Off-label use of the WavelinQ system to create brachial vein outflow pAVF with BVT may be an alternative procedure for HD access creation in select patients with exhausted superficial veins.


Asunto(s)
Fístula Arteriovenosa , Derivación Arteriovenosa Quirúrgica , Fístula Arteriovenosa/etiología , Derivación Arteriovenosa Quirúrgica/efectos adversos , Derivación Arteriovenosa Quirúrgica/métodos , Humanos , Diálisis Renal , Estudios Retrospectivos , Resultado del Tratamiento , Extremidad Superior/irrigación sanguínea , Grado de Desobstrucción Vascular , Venas/diagnóstico por imagen , Venas/cirugía
5.
Cardiovasc Intervent Radiol ; 45(1): 29-40, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34518912

RESUMEN

PURPOSE: To perform a systematic review and meta-analysis to quantify the technical success rate of adrenal venous sampling (AVS) with and without intraprocedural computed tomography (CT). METHODS: A systematic search of the Medline, Scopus, EMBASE, and Web of Science databases for comparative studies using intraprocedural CT was undertaken. More than 1,000 records were screened using titles and abstracts. Full texts of 121 studies were reviewed and 14 eligible studies were identified. Nine studies had adequate comparative data and were included in the meta-analysis. RESULTS: A research synthesis was performed and data from 809 patients were pooled in multiple random effect models. Overall success rate of AVS without and with intraprocedural CT was 72.7% (59.3-83.0%) and 92.5% (86.6-95.9), respectively. The addition of intraprocedural CT increased the technical success rate by 19.8% (P < 0.001), with an odds ratio (OR) of 5.5 (3.3-9.2; P < 0.01). In meta-regression, odds of success with intraprocedural CT was associated with younger age (beta: 0.16 ± 0.05; P:0.001), higher body mass index (BMI; beta:0.08 ± 0.03; P:0.002), and higher selectivity index (defined as the ratio of cortisol in the adrenal vein to that in the inferior vena cava; beta:0.35 ± 0.08, P < 0.001). We found a linear inverse association between operator's success without CT and improved success with intraprocedural CT (R2: 0.86). CONCLUSIONS: Intraprocedural CT is not required for every case, but can be performed in difficult cases or when operators' success is limited. The benefit was more pronounced in younger patients with higher BMI, female gender, and with higher selectivity. LEVEL OF EVIDENCE: III Systematic review and meta-analysis of non-randomized clinical trials.


Asunto(s)
Hiperaldosteronismo , Glándulas Suprarrenales/diagnóstico por imagen , Cateterismo , Femenino , Humanos , Hidrocortisona , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
10.
AJR Am J Roentgenol ; 213(5): 1152-1156, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31216197

RESUMEN

OBJECTIVE. The purpose of this study was to evaluate the safety and technical feasibility of inferior vena cava filter (IVCF) removal when filter elements penetrate adjacent bowel. MATERIALS AND METHODS. A multicenter retrospective review of IVCF retrievals between 2008 and 2018 was performed. Adult patients with either CT or endoscopic evidence of filter elements penetrating bowel before retrieval were included. Technical success of IVCF retrieval was recorded. Patient records were assessed for immediate, 30-day, and 90-day complications after retrieval. RESULTS. Thirty-nine consecutive adult patients (11 men and 28 women; mean age, 51.2 years; age range, 18-81 years) qualified for inclusion. Filter dwell time was a median of 148 days (range, 32-5395 days). No IVCFs were known to have migrated or caused iliocaval thrombosis. Five IVCFs (12.8%) had more than 15° tilt relative to the inferior vena cava (IVC) before retrieval. Three IVCFs (7.7%) had fractured elements identified at the time of retrieval. Mean international normalized ratio (INR) was 1.24 ± 0.53 (SD), and mean platelet count was 262 ± 139 × 103/µL. Ten patients (25.6%) were on antibiotics at the time of retrieval. All 39 IVCFs were successfully retrieved (technical success = 100%). Two patients experienced minor complications in the immediate postprocedural period, which resulted in a minor complication rate of 5.1%. There were no complications (major or minor) identified in any patient at 30 or 90 days after retrieval. The overall major complication rate was 0%. CONCLUSION. Endovascular retrieval of IVCFs with CT evidence of filter elements that have penetrated adjacent bowel is both safe and technically feasible.


Asunto(s)
Remoción de Dispositivos/métodos , Perforación Intestinal/diagnóstico por imagen , Perforación Intestinal/etiología , Filtros de Vena Cava/efectos adversos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Endoscopía Gastrointestinal , Estudios de Factibilidad , Femenino , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Recuento de Plaquetas , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
11.
J Vasc Access ; 20(6): 778-781, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30958089

RESUMEN

Peripherally inserted central catheters provide access to the central chest veins and allow administration of long-term antibiotics, chemotherapy, blood products, fluids, and parenteral nutrition. Peripherally inserted central catheters provide an essential function and are routinely placed safely, but are not without risks. This case describes an unusual complication of peripherally inserted central catheter perforation into the pericardial space with subsequent successful percutaneous removal.


Asunto(s)
Cateterismo Venoso Central/instrumentación , Cateterismo Periférico/instrumentación , Catéteres de Permanencia , Catéteres Venosos Centrales , Remoción de Dispositivos/métodos , Procedimientos Endovasculares , Anciano , Cateterismo Venoso Central/efectos adversos , Cateterismo Periférico/efectos adversos , Humanos , Masculino , Radiografía Intervencional , Resultado del Tratamiento
13.
Am Surg ; 85(8): 806-812, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32051064

RESUMEN

The role of prophylactic vena cava filters (pVCFs) in trauma patients remains controversial. After 20 years of data collection and experience, we reviewed our venous thromboembolism guideline for the efficacy of pVCFs in preventing pulmonary embolism (PE). A retrospective cohort study was performed using our Level I trauma center registry from January 1997 thru December 2016. This population was then divided by the presence of pVCFs. Univariate analysis was performed comparing the incidence of PEs, deep vein thrombosis, and mortality between those with and without a pVCF. There were 35,658 patients identified, of whom 2 per cent (n = 847) received pVCFs. The PE rate was 0.4 per cent in both groups. The deep vein thrombosis rate for pVCFs was 3.9 per cent compared with 0.6 per cent in the no-VCF group (P < 0.0001). Given that there was no difference in the rates of PEs between the cohorts, the subset of patients with a PE were analyzed by their risk factors. Only ventilator days > 3 were associated with a higher risk in the no-pVCF group (0.2 vs 1.5%, P = 0.033). pVCFs did not confer benefit reducing PE rate. In addition, despite their intended purpose, pVCFs cannot eliminate PEs in high-risk trauma patients, suggesting a lack of utility for prophylaxis in this population.


Asunto(s)
Guías de Práctica Clínica como Asunto , Embolia Pulmonar/epidemiología , Filtros de Vena Cava/estadística & datos numéricos , Tromboembolia Venosa/epidemiología , Trombosis de la Vena/epidemiología , Heridas y Lesiones/complicaciones , Adolescente , Adulto , Análisis de Varianza , Femenino , Humanos , Incidencia , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Embolia Pulmonar/mortalidad , Embolia Pulmonar/prevención & control , Sistema de Registros , Respiración Artificial , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Centros Traumatológicos , Resultado del Tratamiento , Filtros de Vena Cava/efectos adversos , Tromboembolia Venosa/mortalidad , Tromboembolia Venosa/prevención & control , Trombosis de la Vena/mortalidad , Trombosis de la Vena/prevención & control , Ventiladores Mecánicos/estadística & datos numéricos , Heridas y Lesiones/epidemiología , Adulto Joven
14.
Clin Chest Med ; 39(3): 645-650, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30122187

RESUMEN

Vena cava filters are implantable devices that are placed to trap thrombus originating in the lower extremities and prevent it from migrating to the lungs. In general, inferior vena cava (IVC) filters are indicated for patients who cannot receive anticoagulation. Other indications for IVC filtration are less clear, and guidelines vary. All patients who have a retrievable IVC filter should be followed, and the removal of the IVC filter should be considered once its indication is lost.


Asunto(s)
Embolia Pulmonar/cirugía , Filtros de Vena Cava/normas , Humanos , Resultado del Tratamiento
15.
Cardiovasc Intervent Radiol ; 41(8): 1184-1188, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29725809

RESUMEN

PURPOSE: To evaluate the safety and technical success of inferior vena cava (IVC) filter retrieval in the setting of aorto-iliac arterial strut penetration. MATERIALS AND METHODS: IVC filter registries from six large United States IVC filter retrieval practices were retrospectively reviewed to identify patients who underwent IVC filter retrieval in the setting of filter strut penetration into the adjacent aorta or iliac artery. Patient demographics, implant duration, indication for placement, IVC filter type, retrieval technique and technical success, adverse events, and post procedural clinical outcomes were identified. Arterial penetration was determined based on pre-procedure CT imaging in all cases. The IVC filter retrieval technique used was at the discretion of the operating physician. RESULTS: Seventeen patients from six US centers who underwent retrieval of an IVC filter with at least one strut penetrating either the aorta or iliac artery were identified. Retrieval technical success rate was 100% (17/17), without any major adverse events. Post-retrieval follow-up ranging from 10 days to 2 years (mean 4.6 months) was available in 12/17 (71%) patients; no delayed adverse events were encountered. CONCLUSIONS: Findings from this series suggest that chronically indwelling IVC filters with aorto-iliac arterial strut penetration may be safely retrieved.


Asunto(s)
Aorta/cirugía , Remoción de Dispositivos/métodos , Arteria Ilíaca/cirugía , Filtros de Vena Cava , Vena Cava Inferior/cirugía , Adulto , Anciano , Aorta/diagnóstico por imagen , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen
16.
J Am Coll Radiol ; 15(1 Pt B): 218-223, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29122504

RESUMEN

The use of social media among interventional radiologists is increasing, with Twitter receiving the most attention. Twitter is an ideal forum for open exchange of ideas from around the world. However, it is important for Twitter users to gain a rudimentary understanding of the many potential communication pathways to connect with other users. An intentional approach to Twitter is vital to efficient and successful use. This article describes several common communication pathways that can be utilized by physicians in their interventional radiology practice.


Asunto(s)
Radiología Intervencionista , Medios de Comunicación Sociales/estadística & datos numéricos , Educación Médica Continua , Humanos , Defensa del Paciente , Educación del Paciente como Asunto , Radiología Intervencionista/educación
19.
J Am Coll Radiol ; 14(9): 1144-1150, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28623048

RESUMEN

BACKGROUND: To determine the impact, if any, of the 2010 FDA safety communication on the rate of inferior vena cava filter (IVCF) placement over time. METHODS: The Nationwide Inpatient Sample was interrogated for the most recent years preceding and after the FDA safety communication-from 2005 to 2014. IVCF placements and associated diagnoses were identified using corresponding International Classification of Diseases, version nine codes. Trends in number of IVCF placement were evaluated in aggregate and by associated diagnoses, both of which were further stratified by hospital geographic cluster, hospital teaching status, and patient demographics. Generalized linear regression models were used to determine statistical significance of trends over time. RESULTS: IVCF placements steadily increased between 2005 and 2010 (100,434 in 2005 versus 129,614 in 2010, growth rate 5.81%). Aggregate IVCF placements subsequently declined between 2010 and 2014 (96,005 in 2014, decline rate -6.48%). IVCF placements peaked in 2010, the year of the FDA advisory. The proportion of filter placements for therapeutic indication of venous thromboembolism increased significantly during the study period (69.8% in 2005 versus 80.4% in 2014, P < .001). Neither trend varied significantly by patient demographics or hospital characteristics. CONCLUSIONS: IVCF placements have declined significantly since 2010, when the FDA advisory was released. The proportion of IVCFs placed in patients with venous thromboembolism, as opposed to prophylactic indications, is increasing.


Asunto(s)
Vigilancia de Productos Comercializados , Filtros de Vena Cava/estadística & datos numéricos , Humanos , Modelos Lineales , Estados Unidos , United States Food and Drug Administration , Filtros de Vena Cava/tendencias , Tromboembolia Venosa/prevención & control
20.
Chest ; 150(6): 1185-1186, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27773746
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA