Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Clin Nucl Med ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38914016

RESUMEN

PURPOSE: The aim of this study was to assess the association among toxicity, dosimetry of organs-at-risk, and disease progression in patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs) treated with 177Lu-DOTATATE. PATIENTS AND METHODS: Thirty-seven patients with GEP-NETs underwent 177Lu-DOTATATE peptide receptor radionuclide therapy (PRRT) in a single-arm, prospective, phase 2 study, where patients were followed up with blood tests, isotopic glomerular filtration rate (iGFR), and imaging examinations (CT/MRI and PET) every 6 months until disease progression. Adverse events (AEs) graded per CTCAEv4.03 and occurring during treatment were collected and followed up until resolution. Dosimetry, including biologically effective doses (BEDs) to kidneys, BED to bone marrow, and absorbed dose (AD) to spleen, was performed after each PRRT cycle. Statistical analyses explored associations among dosimetry, toxicity, and patient progression free-survival. RESULTS: The most common AEs were anemia and lymphopenia (65%), followed by thrombocytopenia and fatigue (each 51%), alopecia (46%), and nausea (41%). The most common grade ≥3 AE was lymphopenia (43%). There was no grade ≥3 nephrotoxicity. The median iGFR % decrease was 11% (P < 0.001), at a median follow-up of 23 months. iGFR %decrease and renal BED did not correlate (Spearman ρ = -0.09). Similarly, no significant association was found between bone marrow BED or spleen AD and the grades of hematological toxicities. We observed no association between progression free-survival and either the decline of renal function or the occurrence of hematological toxicities during PRRT. CONCLUSIONS: This study confirms the safety profile of 177Lu-DOTATATE PRRT in patients with GEP-NETs irrespective of the dosimetry of organs at risk. Kidney, bone marrow, and spleen dosimetry measures were not associated with renal or hematological toxicity.

2.
J Nucl Med ; 65(2): 236-244, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38164576

RESUMEN

Our objective was to predict the outcome of peptide receptor radionuclide therapy (PRRT) using multimodality imaging and tumor dosimetry on gastroenteropancreatic neuroendocrine tumor (GEP-NET) lesions and patients. Methods: This prospective study included patients with progressive GEP-NETs. Treatment consisted of 4 cycles of 7.4 GBq of 177Lu-DOTATATE. Imaging parameters were measured on 68Ga-DOTATATE PET/CT (SUVmax/mean, somatostatin receptor [SSTR] tumor volume [TV], total lesion SSTR expression, and tumor-to-blood and tumor-to-spleen ratios), 18F-FDG PET/CT (SUVmax/mean, metabolically active TV, and total lesion glycolysis), and diffusion-weighted MRI (apparent diffusion coefficient) in a maximum of 5 target lesions per patient at approximately 10 wk after each injection. Tumor dosimetry was performed using SPECT/CT at 3 time points for every cycle. Baseline imaging parameters, their relative changes after PRRT cycle 1 (C1), and the tumor-absorbed dose at C1 were correlated with lesion morphologic outcome. The average values of the imaging parameters and the minimal, maximal, and mean C1 tumor-absorbed dose in each patient were tested for association with progression-free survival (PFS) and best objective response (RECIST 1.1). Results: In the 37 patients, the median PFS was 28 mo. Eleven of the 37 (30%) achieved a partial response (RECIST 1.1). After a median follow-up of 57 mo, the median time to lesion progression had not been reached in 84 morphologically evaluable lesions, with only 12 (14%) progressing (size increase ≥ 20% from baseline). Patients receiving a minimal C1 dose of 35 Gy in all target lesions exhibited a significantly longer PFS (48.1 vs. 26.2 mo; hazard ratio, 0.37; 95% CI, 0.17-0.82; P = 0.02). Volumetric 68Ga-DOTATATE PET parameters correlated with lesion and patient outcome: patients with an SSTR TV decrease of more than 10% after C1 had a longer PFS (51.3 vs. 22.8 mo; hazard ratio, 0.35; 95% CI, 0.16-0.75; P = 0.003). There was no statistical evidence of an association between other dosimetric or imaging parameters and the lesion or patient outcome. Conclusion: Minimal tumor-absorbed dose at C1 is predictive of outcome in patients with GEP-NETs treated with PRRT, providing a basis for personalized dosimetry-guided treatment strategies. An SSTR TV decrease after C1 could be used for early therapy response assessment as a predictor of PRRT outcome.


Asunto(s)
Neoplasias Intestinales , Tumores Neuroendocrinos , Compuestos Organometálicos , Neoplasias Pancreáticas , Tomografía de Emisión de Positrones , Cintigrafía , Neoplasias Gástricas , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/radioterapia , Tumores Neuroendocrinos/tratamiento farmacológico , Estudios Prospectivos , Radioisótopos de Galio , Resultado del Tratamiento , Compuestos Organometálicos/uso terapéutico , Receptores de Somatostatina/metabolismo , Octreótido/uso terapéutico
3.
EJNMMI Phys ; 10(1): 64, 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37853247

RESUMEN

BACKGROUND: Dosimetry after radiopharmaceutical therapy with 177Lu (177Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with 177Lu-RPT. METHODS: A series of 177Lu-filled phantoms were acquired on a StarGuide™ (GE HealthCare), with energy and scatter windows centred at 208 (± 6%) keV and 185 (± 5%) keV, respectively. Images were reconstructed with the manufacturer implementations of OSEM (GE-OSEM) and BSREM (Q.Clear) algorithms, and various combinations of iterations and subsets. Additionally, the manufacturer-recommended Q.Clear-based reconstruction protocol was evaluated. Quantification accuracy, measured as the difference between the SPECT-based and the radionuclide calibrator-based activity, and noise were evaluated in a large cylinder. Recovery coefficients (RCs) and spatial resolution were assessed in a NEMA IEC phantom with sphere inserts. The reconstruction protocols considered suitable for clinical applications were tested on a cohort of patients treated with [177Lu]Lu-PSMA-I&T. RESULTS: The accuracy of the activity from the cylinder, although affected by septal penetration, was < 10% for all reconstructions. Both algorithms featured improved spatial resolution and higher RCs with increasing updates at the cost of noise build-up, but Q.Clear outperformed GE-OSEM in reducing noise accumulation. When the reconstruction parameters were carefully selected, similar values for noise (~0.15), spatial resolution (~1 cm) and RCs were found, irrespective of the reconstruction algorithm. Analogue results were found in patients. CONCLUSIONS: Accurate activity quantification is possible when imaging 177Lu with StarGuide™. However, the impact of septal penetration requires further investigations. GE-OSEM is a valid alternative to the recommended Q.Clear reconstruction algorithm, featuring comparable performances assessed on phantoms and patients.

4.
Eur J Hybrid Imaging ; 7(1): 12, 2023 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-37414964

RESUMEN

BACKGROUND: Recent data demonstrated that personalized dosimetry-based selective internal radiotherapy (SIRT) is associated with better outcome for unresectable hepatocellular carcinoma (HCC). AIM: We aim to evaluate the contribution of personalized predictive dosimetry (performed with Simplicity90® software) in our population of HCC patients by comparing them to our historical cohort whose activity was determined by standard dosimetry. METHODS: This is a retrospective, single-center study conducted between February 2016 and December 2020 that included patients with HCC who received SIRT after simulation based on either standard dosimetry (group A) or, as of December 2017, on personalized dosimetry (group B). Primary endpoints were best overall response (BOR) and objective response rate (ORR) evaluated by mRECIST at 3 months. Safety and toxicity profiles were evaluated at 1- and 3-months post-treatment. For group A we compared the activity to be administered determined a posteriori using Simplicit90Y® and the activity actually administered determined by the standard approach. RESULTS: Between February 2016 and December 2020, 66 patients received 69 simulations leading to 40 treatments. The median follow-up time was equal for both groups, 21 months (range 3-55) in group A and 21 months (range 4-39) in group B. The per patient analysis revealed a significant benefit of personalized predictive dosimetry in terms of better overall response at 3 months (80% vs. 33.3%, p = 0.007) and at 6 months (77.8% vs. 22.2%, p = 0.06). This trend was found in the analysis by nodule with a response rate according to mRECIST of 87.5% for personalized dosimetry versus 68.4% for standard dosimetry at 3 months, p = 0.24. Only one grade 3 biological toxicity (hyperbilirubinemia) was noted in group A. The comparison between the administered activity and the recommended activity recalculated a posteriori using Simplicit90Y® showed that the vast majority of patients who progressed (83.33%) received less activity than that recommended by the personalized approach or an inadequate distribution of the administered activity. CONCLUSIONS: Our study aligns to recent literature and confirms that the use of personalized dosimetry allows a better selection of HCC patients who can benefit from SIRT, and consequently, improves the effectiveness of this treatment.

5.
Phys Med ; 103: 138-146, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36308999

RESUMEN

PURPOSE: The aim of this study was to perform a quantitative quality assurance of diffusion-weighted MRI to assess the variability of the mean apparent diffusion coefficient (ADC) and other radiomic features across the scanners involved in the REGINA trial. MATERIALS AND METHODS: The NIST/QIBA diffusion phantom was acquired on six 3 T scanners from five centres with a rectum-specific diffusion protocol. All sequences were repeated in each scan session without moving the phantom from the table. Linear interpolation to two isotropic voxel spacing (0.9 and 4 mm) was performed as well as the ComBat feature harmonisation method between scanners. The absolute accuracy error was evaluated for the mean ADC. Repeatability and reproducibility within-subject coefficients of variation (wCV) were computed for 142 radiomic features. RESULTS: For the mean ADC, accuracy error ranged between 0.1 % and 8.5 %, repeatability was <1 % and reproducibility was <3 % for diffusivity range between 0.4 and 1.1x10-3mm2/s. For the other radiomic features, wCV was below 10 % for 24 % and 15 % features for repeatability with resampling 0.9 mm and 4 mm, respectively, and 13 % and 11 % feature for reproducibility. ComBat method could improve significantly the wCV compared to reproducibility without ComBat (p-value < 0.001) but variation was still high for most of the features. CONCLUSION: Our study provided the first investigation of feature selection for development of robust predictive models in the REGINA trial, demonstrating the added value of such a quality assurance process to select conventional and radiomic features in prospective multicentre trials.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios Prospectivos , Fantasmas de Imagen , Difusión
6.
Biomed Phys Eng Express ; 8(6)2022 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-36049399

RESUMEN

INTRODUCTION: Radiomics is a promising imaging-based tool which could enhance clinical observation and identify representative features. To avoid different interpretations, the Image Biomarker Standardisation Initiative (IBSI) imposed conditions for harmonisation. This study evaluates IBSI-compliant radiomics applications against a known benchmark and clinical datasets for agreements. MATERIALS AND METHODS: The three radiomics platforms compared were RadiomiX Research Toolbox, LIFEx v7.0.0, and syngo.via Frontier Radiomics v1.2.5 (based on PyRadiomics v2.1). Basic assessment included comparing feature names and their formulas. The IBSI digital phantom was used for evaluation against reference values. For agreement evaluation (including same software but different versions), two clinical datasets were used: 27 contrast-enhanced computed tomography (CECT) of colorectal liver metastases and 39 magnetic resonance imaging (MRI) of breast cancer, including intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) MRI. The intraclass correlation coefficient (ICC, lower 95% confidence interval) was used, with 0.9 as the threshold for excellent agreement. RESULTS: The three radiomics applications share 41 (3 shape, 8 intensity, 30 texture) out of 172, 84 and 110 features for RadiomiX, LIFEx and syngo.via, respectively, as well as wavelet filtering. The naming convention is, however, different between them. Syngo.via had excellent agreement with the IBSI benchmark, while LIFEx and RadiomiX showed slightly worse agreement. Excellent reproducibility was achieved for shape features only, while intensity and texture features varied considerably with the imaging type. For intensity, excellent agreement ranged from 46% for the DCE maps to 100% for CECT, while this lowered to 44% and 73% for texture features, respectively. Wavelet features produced the greatest variation between applications, with an excellent agreement for only 3% to 11% features. CONCLUSION: Even with IBSI-compliance, the reproducibility of features between radiomics applications is not guaranteed. To evaluate variation, quality assurance of radiomics applications should be performed and repeated when updating to a new version or adding a new modality.


Asunto(s)
Imagen por Resonancia Magnética , Programas Informáticos , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
8.
Eur J Nucl Med Mol Imaging ; 48(5): 1570-1584, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33433699

RESUMEN

PURPOSE: A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (90Y)-resin microspheres. METHODS: A steering committee of 23 international experts representing all participating specialties formulated recommendations for SIRT with 90Y-resin microspheres activity prescription and post-treatment dosimetry, based on literature searches and the responses to a 61-question survey that was completed by 43 leading experts (including the steering committee members). The survey was validated by the steering committee and completed anonymously. In a face-to-face meeting, the results of the survey were presented and discussed. Recommendations were derived and level of agreement defined (strong agreement ≥ 80%, moderate agreement 50%-79%, no agreement ≤ 49%). RESULTS: Forty-seven recommendations were established, including guidance such as a multidisciplinary team should define treatment strategy and therapeutic intent (strong agreement); 3D imaging with CT and an angiography with cone-beam-CT, if available, and 99mTc-MAA SPECT/CT are recommended for extrahepatic/intrahepatic deposition assessment, treatment field definition and calculation of the 90Y-resin microspheres activity needed (moderate/strong agreement). A personalised approach, using dosimetry (partition model and/or voxel-based) is recommended for activity prescription, when either whole liver or selective, non-ablative or ablative SIRT is planned (strong agreement). A mean absorbed dose to non-tumoural liver of 40 Gy or less is considered safe (strong agreement). A minimum mean target-absorbed dose to tumour of 100-120 Gy is recommended for hepatocellular carcinoma, liver metastatic colorectal cancer and cholangiocarcinoma (moderate/strong agreement). Post-SIRT imaging for treatment verification with 90Y-PET/CT is recommended (strong agreement). Post-SIRT dosimetry is also recommended (strong agreement). CONCLUSION: Practitioners are encouraged to work towards adoption of these recommendations.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/radioterapia , Microesferas , Tomografía Computarizada por Tomografía de Emisión de Positrones , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Radioisótopos de Itrio/uso terapéutico
9.
EJNMMI Phys ; 7(1): 75, 2020 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-33315160

RESUMEN

BACKGROUND: The relationship between the mean absorbed dose delivered to the tumour and the outcome in liver metastases from colorectal cancer patients treated with radioembolization has already been presented in several studies. The optimization of the personalized therapeutic activity to be administered is still an open challenge. In this context, how well the 99mTc-MAA SPECT/CT predicts the absorbed dose delivered by radioembolization is essential. This work aimed to analyse the differences between predictive 99mTc-MAA-SPECT/CT and post-treatment 90Y-microsphere PET/CT dosimetry at different levels. Dose heterogeneity was compared voxel-to-voxel using the quality-volume histograms, subsequently used to demonstrate how it could be used to identify potential clinical parameters that are responsible for quantitative discrepancies between predictive and post-treatment dosimetry. RESULTS: We analysed 130 lesions delineated in twenty-six patients. Dose-volume histograms were computed from predictive and post-treatment dosimetry for all volumes: individual lesion, whole tumoural liver (TL) and non-tumoural liver (NTL). For all dose-volume histograms, the following indices were extracted: D90, D70, D50, Dmean and D20. The results showed mostly no statistical differences between predictive and post-treatment dosimetries across all volumes and for all indices. Notably, the analysis showed no difference in terms of Dmean, confirming the results from previous studies. Quality factors representing the spread of the quality-volume histogram (QVH) curve around 0 (ideal QF = 0) were determined for lesions, TL and NTL. QVHs were classified into good (QF < 0.18), acceptable (0.18 ≤ QF < 0.3) and poor (QF ≥ 0.3) correspondence. For lesions and TL, dose- and quality-volume histograms are mostly concordant: 69% of lesions had a QF within good/acceptable categories (40% good) and 65% of TL had a QF within good/acceptable categories (23% good). For NTL, the results showed mixed results with 48% QF within the poor concordance category. Finally, it was demonstrated how QVH analysis could be used to define the parameters that predict the significant differences between predictive and post-treatment dose distributions. CONCLUSION: It was shown that the use of the QVH is feasible in assessing the predictive value of 99mTc-MAA SPECT/CT dosimetry and in estimating the absorbed dose delivered to liver metastases from colorectal cancer via 90Y-microspheres. QVH analyses could be used in combination with DVH to enhance the predictive value of 99mTc-MAA SPECT/CT dosimetry and to assist personalized activity prescription.

10.
Oncotarget ; 11(6): 589-599, 2020 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-32110279

RESUMEN

We investigated on the added prognostic value of a three-scale combined molecular imaging with 68Ga-DOTATATE and 18F-FDG PET/CT, (compared to Ki-67 based histological grading), in gastroenteropancreatic neuroendocrine neoplasia patients. 85 patients with histologically proven metastatic gastroenteropancreatic neuroendocrine neoplasias, who underwent combined PET/CT imaging were retrospectively evaluated. Highest Ki-67 value available at time of 18F-FDG PET/CT was recorded. Patients were classified according to World Health Organization/European Neuroendocrine Tumor Society histological grades (G1, G2, G3) and into three distinct imaging categories (C1: all lesions are 18F-FDG negative/68Ga-DOTATATE positive, C2: patients with one or more 18F-FDG positive lesions, all of them 68Ga-DOTATATE positive, C3: patients with one or more 18F-FDG positive lesions, at least one of them 68Ga-DOTATATE negative). The primary endpoint of the study was Progression-Free Survival, assessed from the date of 18F-FDG PET/CT to the date of radiological progression according to Response Evaluation Criteria In Solid Tumors version 1.1. Classification according to histological grade did not show significant statistical difference in median Progression-Free Survival between G1 and G2 but was significant between G2 and G3 patients. In contrast, median Progression-Free Survival was significantly higher in C1 compared to C2 and in C2 compared to C3 patients, revealing three distinctive imaging categories, each with highly distinctive prognosis. Our three-scale combined 68Ga-DOTATATE/18F-FDG PET imaging classification holds high prognostic value in patients with metastatic gastroenteropancreatic neuroendocrine neoplasias.

11.
J Surg Oncol ; 121(2): 350-356, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31721228

RESUMEN

BACKGROUND AND OBJECTIVES: Selection for surgery in patients with colorectal liver metastases (CRLM) remains inaccurate. We evaluated if CRLM baseline metabolic characteristics, assessed by [18]F-fluorodeoxyglucose-positron emission tomography/computed tomography (18 FDG-PET/CT), could predict postoperative outcomes. METHODS: In a retrospective series of patients undergoing surgery for CRLM, we defined two groups: the long-term survival (LTS) and early relapse (ER) groups, where the postoperative recurrence-free survivals were ≥5 years or <1 year, respectively. We analyzed the patients in whom baseline 18 FDG-PET/CT was available. Clinicopathologic parameters, clinical risk score (CRS), and baseline 18 FDG-PET/CT characteristics were compared between LTS and ER groups. A metabolic CRS (mCRS) was implemented, adding one point to the standard five-point CRS when the highest tumor standardized uptake values (SUVmax )/normal liver mean SUV (SUVmean(liver) ) ratios were >4.3, defining low- and high-risk mCRS by scores of 0 to 2 and 3 to 6, respectively. RESULTS: From a series of 450 patients operated for CRLM (mean follow-up of 58 months), we included for analysis 23 and 30 patients in the LTS and ER groups, respectively. Clinicopathologic parameters and CRS were similar in the LTS and ER groups. Median SUVmax /SUVmean(liver) ratios were higher in ER vs LTS patients (4.2 and 2.8, P = .008, respectively). mCRS was increased in ER patients (P = .024); 61% of LTS patients had low-risk mCRS and 73% of the ER patients had high-risk mCRS (P = .023). CONCLUSIONS: 18 FDG-PET/CT characteristics combined with traditional CRS may represent a new tool to improve selection for surgery in patients with CRLM.

12.
Eur J Nucl Med Mol Imaging ; 46(11): 2270-2279, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31324943

RESUMEN

PURPOSE: Reported outcomes of patients with intra-hepatic cholangiocarcinoma (IH-CCA) treated with radioembolization are highly variable, which indicates differences in included patients' characteristics and/or procedure-related variables. This study aimed to identify patient- and treatment-related variables predictive for radioembolization outcome. METHODS: This retrospective multicenter study enrolled 58 patients with unresectable and chemorefractory IH-CCA treated with resin 90Y-microspheres. Clinicopathologic data were collected from patient records. Metabolic parameters of liver tumor(s) and presence of lymph node metastasis were measured on baseline 18F-FDG-PET/CT. 99mTc-MAA tumor to liver uptake ratio (TLRMAA) was computed for each lesion on the SPECT-CT. Activity prescription using body-surface-area (BSA) or more personalized partition-model was recorded. The study endpoint was overall survival (OS) starting from date of radioembolization. Statistical analysis was performed by the log-rank test and multivariate Cox's proportional hazards model. RESULTS: Median OS (mOS) post-radioembolization of the entire cohort was 10.3 months. Variables associated with significant differences in terms of OS were serum albumin (hazard ratio (HR) = 2.78, 95%CI:1.29-5.98, p = 0.002), total bilirubin (HR = 2.17, 95%CI:1.14-4.12, p = 0.009), aspartate aminotransferase (HR = 2.96, 95%CI:1.50-5.84, p < 0.001), alanine aminotransferase (HR = 2.02, 95%CI:1.05-3.90, p = 0.01) and γ-GT (HR = 2.61, 95%CI:1.31-5.22, p < 0.001). The presence of lymph node metastasis as well as a TLRMAA < 1.9 were associated with shorter mOS: HR = 2.35, 95%CI:1.08-5.11, p = 0.008 and HR = 2.92, 95%CI:1.01-8.44, p = 0.009, respectively. Finally, mOS was significantly shorter in patients treated according to the BSA method compared to the partition-model: mOS of 5.5 vs 14.9 months (HR = 2.52, 95%CI:1.23-5.16, p < 0.001). Multivariate analysis indicated that the only variable that increased outcome prediction above the clinical variables was the activity prescription method with HR of 2.26 (95%CI:1.09-4.70, p = 0.03). The average mean radiation dose to tumors was significantly higher with the partition-model (86Gy) versus BSA (38Gy). CONCLUSION: Radioembolization efficacy in patients with unresectable recurrent and/or chemorefractory IH-CCA strongly depends on the tumor radiation dose. Personalized activity prescription should be performed.


Asunto(s)
Colangiocarcinoma/tratamiento farmacológico , Colangiocarcinoma/radioterapia , Embolización Terapéutica , Medicina de Precisión , Radioisótopos de Itrio/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Metástasis Linfática , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Resultado del Tratamiento
13.
EJNMMI Res ; 8(1): 60, 2018 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-30006851

RESUMEN

BACKGROUND: The aim of this work was to confirm that post-selective internal radiation therapy (SIRT) 90Y-PET/CT-based dosimetry correlates with lesion metabolic response and to determine its correlation with overall survival (OS) in liver-only metastases from colorectal cancer (mCRC) patients treated with SIRT. Twenty-four mCRC patients underwent pre/post-SIRT FDG-PET/CT and post-SIRT 90Y-PET/CT. Lesions delineated on pre/post-SIRT FDG-PET/CT were classified as non-metabolic responders (total lesion glycolysis (TLG)-decrease < 15%) and high-metabolic responders (TLG-decrease ≥ 50%). Lesion delineations were projected on the anatomically registered 90Y-PET/CT. Voxel-based 3D dosimetrywas performed on the 90Y-PET/CT and lesions' mean absorbed dose (Dmean) was measured. The coefficient of correlation between Dmean and TLG-decrease was calculated. The ability of lesion Dmean to predict non-metabolic response and high-metabolic response was tested and two cutoff values (Dmean-under-treated and Dmean-well-treated) were determined using ROC analysis. Patients were dichotomised in the "treated" group (all the lesions received a Dmean > Dmean-under-treated) and in the "under-treated" group (at least one lesion received a Dmean < Dmean-under-treated). Kaplan-Meier product limit method was used to describe OS curves. RESULTS: Fifty-seven evaluable mCRC lesions were included. The coefficient of correlation between Dmean and TLG-decrease was 0.82. Two lesion Dmean cutoffs of 39 Gy (sensitivity 80%, specificity 95%, predictive-positive-value 86% and negative-predictive-value 92%) and 60 Gy (sensitivity 70%, specificity 95%, predictive positive-value 96% and negative-predictive-value 63%) were defined to predict non-metabolic response and high-metabolic response respectively. Patients with all lesions Dmean> 39 Gy had a significantly longer OS (13 months) than patients with at least one lesion Dmean < 39 Gy (OS = 5 months) (p = 0.012;hazard-ratio, 2.6 (95% CI 0.98-7.00)). CONCLUSIONS: In chemorefractory mCRC patients treated with SIRT, lesion Dmean determined on post-SIRT 90Y-PET/CT correlates with metabolic response and higher lesion Dmean is associated with prolonged OS.

14.
HPB (Oxford) ; 20(7): 641-648, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29486918

RESUMEN

BACKGROUND/PURPOSE: Preoperative selective internal radiation therapy (SIRT) may improve the results of partial hepatectomy (PH) or radiofrequency destruction (RF) for hepatocellular carcinoma (HCC) in patients with cirrhosis. The aim of this study was to evaluate the feasibility and safety of this combined approach. METHODS: Patients with cirrhosis and HCC selected for PH or RF were prospectively included and systematically proposed for preoperative SIRT. Feasibility and safety of SIRT and post-SIRT PH or RF were assessed. RESULTS: Thirty patients were included. SIRT was contraindicated in seven, due to lack of access to tumour artery or to hepato-pulmonary shunts. SIRT was performed in 23 patients without significant complications. Post-SIRT, surgery was refuted in seven patients, due to tumour progression or the patient's deteriorating condition. After surgery, major complications were observed in 2/16 patients (12.5%) and one patient died 52 days post-surgery. A major tumour pathological response was seen in most patients who underwent surgery after SIRT. CONCLUSIONS: On intention-to-treat basis, the overall feasibility of combining preoperative SIRT and surgery was limited. Preoperative SIRT did not increase expected operative morbidity, but post-SIRT, a third of patients were refuted for surgery. Accurate selection criteria and potential long-term oncological benefit of this approach remains to be determined. ClinicalTrials.gov NCT01686880.


Asunto(s)
Carcinoma Hepatocelular/terapia , Hepatectomía , Cirrosis Hepática/complicaciones , Neoplasias Hepáticas/terapia , Terapia Neoadyuvante/métodos , Ablación por Radiofrecuencia , Radiofármacos/administración & dosificación , Radioisótopos de Itrio/administración & dosificación , Adulto , Anciano , Bélgica , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/etiología , Carcinoma Hepatocelular/mortalidad , Estudios de Factibilidad , Femenino , Hepatectomía/efectos adversos , Hepatectomía/mortalidad , Humanos , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/mortalidad , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/etiología , Neoplasias Hepáticas/mortalidad , Masculino , Persona de Mediana Edad , Terapia Neoadyuvante/efectos adversos , Terapia Neoadyuvante/mortalidad , Proyectos Piloto , Estudios Prospectivos , Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/mortalidad , Radiofármacos/efectos adversos , Radioterapia Adyuvante , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Radioisótopos de Itrio/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...