Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Orthop Translat ; 15: 1-8, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30128289

RESUMEN

OBJECTIVE: The objective of this study is to use 3D digital lumbar models to investigate and simulate the optimal posterior operative approach for safe decompression and insertion of an interbody cage. METHODS: Thirty lumbar spine (L3-S1) computed tomography data are collected for 3D reconstruction. We cut medial half part of the superior facet and define the distance between the margin of the operative side of the spinous process and the medial margin of the cut superior facet as "medial distance (MD)". Then, we cut the total superior facet and define the distance between the margin of the operative side of the spinous process and the lateral side of the junction of the pedicle and the vertebral body as "extend distance (ED)". The feasible insertion of the current standard width size (10 mm and 12 mm) interbody cages was assessed by the two aforementioned MD and ED approaches. Besides the ED, we also simulate four other extensive options of lateral upper, lateral lower, vertical upper and lower and transmedian contralateral decompression on 3D digital lumbar model. RESULTS: The MD increased from 13.48 ± 1.28 mm at L3/4 to 18.05 ± 1.43 mm at L5/S1, and the ED increased from 16.64 ± 1.34 mm at L3/4 to 21.12 ± 1.62 mm at L5/S1. To insert a 10-mm-wide cage, 16.7% (left) and 13.3% (right) of MD for L3/4 is not enough, 60.0% (left) and 46.7% (right) of MD for L3/4 is subsafe, 13.3% (left) and 16.7% (right) of MD for L4/5 is subsafe and all others are safe. To insert a 12-mm-wide cage, 76.7% (left) and 60.0% (right) of MD for L3/4 is not enough, 20.0% (left) and 30.0% (right) of MD for L3/4 is subsafe, 13.3%% (left) and 16.7% (right) of MD for L4/5 is not enough, 63.3% (left) and 56.7% (right) of MD for L4/5 is subsafe and 6.7% (left) and 10.0% (right) of MD for L5/S1 is subsafe, whereas 33.3%% (left) and 30.0% (right) of ED for L3/4 is subsafe, 3.3% (left) and 3.3% (right) of ED for L4/5 is subsafe and all others are safe. Besides the ED, on 3D models, four other extensive options could be simulated too and may need to be performed for different special individuals. CONCLUSION: Our 3D digital image study provides a feasible optimal medial transforaminal lumbar interbody fusion approach with five extensive options on lower lumbar region. It can provide safe lumbar decompression and interbody fusion in most population. In addition, surgeons can choose the different extensive options for special individual conditions. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Transforminal lumbar interbody fusion is very common used for lumbar degenerative diseases. The optimal medial transforminal lumbar interbody fusion with five options provide a safe and precise approach for surgeons in treatment of lumbar degenerative diseases.

2.
Quant Imaging Med Surg ; 8(4): 383-390, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29928603

RESUMEN

BACKGROUND: The L5 nerve root could be compressed at both L4-5 and L5-S1 regions. If L5 nerve root has confirmed compression at L4-5 level and questionable compression at L5-S1 foramina, performing both surgeries at L4-5 and L5-S1 levels may induce unnecessary extra surgery on L5-S1; however, ignoring foraminal stenosis of L5/S1 may require re-exploration. METHODS: Two hundred seventeen patients with L5 nerve root compressed at L4-5 lateral access were performed with L4-5 decompression and interbody fusion. Lee et al. grade classification was used to assess the foraminal stenosis of L5-S1 preoperatively. Nerve root probe was designed and used to detect if there were foraminal stenosis at L5-S1 level that compressing the exiting L5 nerve root. Visual analog scale (VAS) of low back pain, leg pain and Oswestry Disability Index (ODI) were used to assess clinical outcomes. RESULTS: For all of 217 patients who underwent L4-5 surgery, L5-S1 foramina were preoperatively assessed as: grade 0: 125 cases, grade 1: 58 cases, grade 2: 23 cases, and grade 3: 11 cases. After intra-operative L5 nerve root detection, 11/11 patients with grade 3 radiographic foraminal stenosis, 6/23 (26.1%) with grade 2 and 2/58 (3.4%) who had grade 1 underwent L4-5 and L5-S1 transforaminal lumbar interbody fusion (TLIF), the others received only L4-5 TLIF. Compared to pre-operative baseline data, both L4-5 TLIF and L4-5 and L5-S1 TLIF groups had significant decreased VAS of low back pain and leg pain, and ODI at 3 and 24 months after operation. CONCLUSIONS: We suggested that our novel nerve root probe combined with pre-operative radiographic grade may be helpful to surgeons to identify the single or double compression of L5 nerve root and make a more precise surgical strategy to improve surgical outcome than the method depended on pre-operative radiographic grade alone.

3.
Ann Transl Med ; 6(6): 107, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29707556

RESUMEN

BACKGROUND: To investigate the outcomes of using percutaneous kyphoplasty in the treatment of the secondary osteoporotic vertebral compression fractures. METHODS: Eighty-one patients had the secondary single segmental osteoporotic vertebral compression fractures after the initial fractures and treated by percutaneous kyphoplasty were reviewed, 74 of them had minimum 2 years follow-up were included in this study. The 74 patients with primary osteoporotic vertebral compression fractures treated by percutaneous kyphoplasty at the same time period were matched as control group in 1:1 ratio. Visual Analogue Scales (VAS) and Oswestry Disability Index (ODI) were used to assess the back pain and functional outcomes. The kyphotic angulation (KA) and compression ratio (CR) of the fractured vertebra was measured too. RESULTS: Both the secondary fracture group and control group had significantly relieved back pain, improved functional outcomes, corrected KA and restored CR after operation, but no difference was found between two groups. CONCLUSIONS: Our findings suggest that percutaneous kyphoplasty is an effective and safe procedure for patients with secondary single segmental osteoporotic vertebral compression fractures; it can achieve similar clinical outcomes to the primary osteoporotic vertebral compression fractures.

4.
World J Gastroenterol ; 23(10): 1891-1898, 2017 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-28348496

RESUMEN

AIM: To assess the validity and reliability of the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Colorectal Cancer 29 (EORTC QLQ-CR29) in Chinese patients with colorectal cancer (CRC). METHODS: From March 2014 to January 2015, 356 patients with CRC from four different hospitals in China were enrolled in the study, and all patients self-administered the EORTC QLQ-CR29 and the quality of life core questionnaire (EORTC QLQ-C30). Evaluation of the scores was based on the Karnofsky Performance Scale (KPS). The reliability and validity of the questionnaires were assessed by Cronbach's α coefficient, the Spearman correlation test and Wilcoxon rank sum test. RESULTS: The EORTC QLQ-CR29 showed satisfactory reliability (α > 0.7), although the urinary frequency and blood and mucus in stool dimensions had only moderate reliability (α = 0.608). The multitrait scaling analyses showed good convergent (r > 0.4) and discriminant validity. Significant differences were obtained for each item in the different KPS subgroups (KPS ≤ 80; KPS > 80). Body image and most single-item dimensions showed statistically significant differences in patients with a stoma compared with the rest of the patients. CONCLUSION: The EORTC QLQ-CR29 exhibits high validity and reliability in Chinese patients with CRC, and can therefore be recommended as a valuable tool for the assessment of quality of life in these patients.


Asunto(s)
Imagen Corporal/psicología , Neoplasias Colorrectales/psicología , Psicometría/métodos , Calidad de Vida , Estomas Quirúrgicos/efectos adversos , Adulto , Anciano , Pueblo Asiatico/psicología , China/epidemiología , Neoplasias Colorrectales/complicaciones , Neoplasias Colorrectales/epidemiología , Neoplasias Colorrectales/cirugía , Femenino , Humanos , Estado de Ejecución de Karnofsky , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA