Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Adv Sci (Weinh) ; : e2307837, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38488694

RESUMEN

Endo-microscopy is crucial for real-time 3D visualization of internal tissues and subcellular structures. Conventional methods rely on axial movement of optical components for precise focus adjustment, limiting miniaturization and complicating procedures. Meta-device, composed of artificial nanostructures, is an emerging optical flat device that can freely manipulate the phase and amplitude of light. Here, an intelligent fluorescence endo-microscope is developed based on varifocal meta-lens and deep learning (DL). The breakthrough enables in vivo 3D imaging of mouse brains, where varifocal meta-lens focal length adjusts through relative rotation angle. The system offers key advantages such as invariant magnification, a large field-of-view, and optical sectioning at a maximum focal length tuning range of ≈2 mm with 3 µm lateral resolution. Using a DL network, image acquisition time and system complexity are significantly reduced, and in vivo high-resolution brain images of detailed vessels and surrounding perivascular space are clearly observed within 0.1 s (≈50 times faster). The approach will benefit various surgical procedures, such as gastrointestinal biopsies, neural imaging, brain surgery, etc.

2.
ACS Appl Mater Interfaces ; 15(12): 15047-15058, 2023 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-36916875

RESUMEN

Sprouting angiogenesis is orchestrated by an intricate balance of biochemical and mechanical cues in the local tissue microenvironment. Interstitial flow has been established as a potent regulator of angiogenesis. Similarly, extracellular matrix (ECM) physical properties, such as stiffness and microarchitecture, have also emerged as important mediators of angiogenesis. However, the interplay between interstitial flow and ECM physical properties in the initiation and control of angiogenesis is poorly understood. Using a three-dimensional (3D) microfluidic tissue analogue of angiogenic sprouting with defined interstitial flow superimposed over ECM with well-characterized physical properties, we found that the addition of hyaluronan (HA) to collagen-based matrices significantly enhances sprouting induced by interstitial flow compared to responses in collagen-only hydrogels. We confirmed that both the stiffness and matrix pore size of collagen-only hydrogels were increased by the addition of HA. Interestingly, interstitial flow-potentiated sprouting responses in collagen/HA matrices were not affected when functionally blocking the HA receptor CD44. In contrast, enzymatic depletion of HA in collagen/HA matrices with hyaluronidase (HAdase) resulted in decreased stiffness, pore size, and interstitial flow-mediated sprouting to the levels observed in collagen-only matrices. Taken together, these results suggest that HA enhances interstitial flow-mediated angiogenic sprouting through its alterations to collagen ECM stiffness and pore size.


Asunto(s)
Señales (Psicología) , Matriz Extracelular , Matriz Extracelular/química , Colágeno/química , Fenómenos Fisiológicos Cardiovasculares , Hidrogeles/farmacología
3.
Drug Deliv ; 30(1): 97-107, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36533878

RESUMEN

Transcranial focused shockwave (FSW) is a novel noninvasive brain stimulation that can open blood-brain barriers (BBB) and blood-cerebrospinal fluid barriers (BCSFB) with a single low-energy (energy flux density 0.03 mJ/mm2) pulse and low-dose microbubbles (2 × 106/kg). Similar to focused ultrasound, FSW deliver highly precise stimulation of discrete brain regions with adjustable focal lengths that essentially covers the whole brain. By opening the BCSFB, it allows for rapid widespread drug delivery to the whole brain by cerebrospinal fluid (CSF) circulation. Although no definite adverse effect or permeant injury was noted in our previous study, microscopic hemorrhage was infrequently observed. Safety concerns remain the major obstacle to further application of FSW in brain. To enhance its applicability, a modified single pulse FSW technique was established that present 100% opening rate but much less risk of adverse effect than previous methods. By moving the targeting area 2.5 mm more superficially on the left lateral ventricle as compared with the previous methods, the microscopic hemorrhage rate was reduced to zero. We systemically examine the safety profiles of the modified FSW-BCSFB opening regarding abnormal behavior and brain injury or hemorrhage 72 hr after 0, 1, and 10 pulses of FSW-treatment. Animal behavior, physiological monitor, and brain MRI were examined and recorded. Brain section histology was examined for hemorrhage, apoptosis, inflammation, oxidative stress related immunohistochemistry and biomarkers. The single pulse FSW group demonstrated no mortality or gross/microscopic hemorrhage (N = 30), and no observable changes in all examined outcomes, while 10 pulses of FSW was found to be associated with microscopic and temporary RBC extravasation (N = 6/30), and abnormal immunohistochemistry biomarkers which showed a trend of recovery at 72 hrs. The results suggest that single pulse low-energy FSW-BCSFB opening is effective, safe and poses minimal risk of injury to brain tissue (Sprague Dawley, SD rats).


Asunto(s)
Barrera Hematoencefálica , Microburbujas , Animales , Ratas , Ratas Sprague-Dawley , Encéfalo , Sistemas de Liberación de Medicamentos/métodos , Hemorragia/patología
4.
Fluids Barriers CNS ; 19(1): 3, 2022 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-34991647

RESUMEN

BACKGROUND: The blood-cerebrospinal fluid (CSF) barrier (BCSFB) is critically important to the pathophysiology of the central nervous system (CNS). However, this barrier prevents the safe transmission of beneficial drugs from the blood to the CSF and thus the spinal cord and brain, limiting their effectiveness in treating a variety of CNS diseases. METHODS: This study demonstrates a method on SD rats for reversible and site-specific opening of the BCSFB via a noninvasive, low-energy focused shockwave (FSW) pulse (energy flux density 0.03 mJ/mm2) with SonoVue microbubbles (2 × 106 MBs/kg), posing a low risk of injury. RESULTS: By opening the BCSFB, the concentrations of certain CNS-impermeable indicators (70 kDa Evans blue and 500 kDa FITC-dextran) and drugs (penicillin G, doxorubicin, and bevacizumab) could be significantly elevated in the CSF around both the brain and the spinal cord. Moreover, glioblastoma model rats treated by doxorubicin with this FSW-induced BCSFB (FSW-BCSFB) opening technique also survived significantly longer than untreated controls. CONCLUSION: This is the first study to demonstrate and validate a method for noninvasively and selectively opening the BCSFB to enhance drug delivery into CSF circulation. Potential applications may include treatments for neurodegenerative diseases, CNS infections, brain tumors, and leptomeningeal carcinomatosis.


Asunto(s)
Antibacterianos/farmacocinética , Antineoplásicos/farmacocinética , Barrera Hematoencefálica , Líquido Cefalorraquídeo , Plexo Coroideo , Sistemas de Liberación de Medicamentos , Animales , Sistemas de Liberación de Medicamentos/instrumentación , Sistemas de Liberación de Medicamentos/métodos , Ratas , Ratas Sprague-Dawley , Sonido
5.
Elife ; 102021 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-34569932

RESUMEN

Accumulating evidence has shown transcranial low-intensity ultrasound can be potentially a non-invasive neural modulation tool to treat brain diseases. However, the underlying mechanism remains elusive and the majority of studies on animal models applying rather high-intensity ultrasound that cannot be safely used in humans. Here, we showed low-intensity ultrasound was able to activate neurons in the mouse brain and repeated ultrasound stimulation resulted in adult neurogenesis in specific brain regions. In vitro calcium imaging studies showed that a specific ultrasound stimulation mode, which combined with both ultrasound-induced pressure and acoustic streaming mechanotransduction, is required to activate cultured cortical neurons. ASIC1a and cytoskeletal proteins were involved in the low-intensity ultrasound-mediated mechanotransduction and cultured neuron activation, which was inhibited by ASIC1a blockade and cytoskeleton-modified agents. In contrast, the inhibition of mechanical-sensitive channels involved in bilayer-model mechanotransduction like Piezo or TRP proteins did not repress the ultrasound-mediated neuronal activation as efficiently. The ASIC1a-mediated ultrasound effects in mouse brain such as immediate response of ERK phosphorylation and DCX marked neurogenesis were statistically significantly compromised by ASIC1a gene deletion. Collated data suggest that ASIC1a is the molecular determinant involved in the mechano-signaling of low-intensity ultrasound that modulates neural activation in mouse brain.


Asunto(s)
Canales Iónicos Sensibles al Ácido/metabolismo , Encéfalo/metabolismo , Mecanotransducción Celular , Neurogénesis , Neuronas/metabolismo , Ondas Ultrasónicas , Canales Iónicos Sensibles al Ácido/genética , Animales , Encéfalo/citología , Células CHO , Señalización del Calcio , Cricetulus , Citoesqueleto/metabolismo , Proteínas de Dominio Doblecortina , Proteína Doblecortina , Quinasas MAP Reguladas por Señal Extracelular/metabolismo , Ratones Endogámicos C57BL , Ratones Noqueados , Proteínas Asociadas a Microtúbulos/metabolismo , Neuropéptidos/metabolismo , Fosforilación , Presión , Factores de Tiempo
6.
Front Oncol ; 11: 711088, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34395286

RESUMEN

BACKGROUND: Glioblastoma multiforme (GBM) is currently the most devastating brain tumor globally and produces a high mortality rate. GBM is also challenging to eradicate using surgery due to its invasive characteristics. Moreover, the blood-brain barrier (BBB) increases the difficulty of transporting most therapeutic drugs to tumor sites. The use of transcranial focused ultrasound (FUS) has recently been investigated for opening the BBB to facilitate drug delivery. A special form of FUS, the shockwave (SW), has also been shown to open BBB efficiently. SW has several advantages including no heating effect, less reactive oxygen species production, good transcranial ability, and no need to supply microbubbles. METHODS: We employed a commercial SW device, which is a common tool used for musculoskeletal disorders, to improve doxorubicin delivery across the BBB and evaluated its therapeutic efficacy on GBM rat models. SW emits relatively short but stronger mechanical pulses comparing with FUS. RESULTS: The results demonstrated that doxorubicin combined with SW treatment substantially inhibited tumor growth and prolonged overall survival. CONCLUSIONS: The present study shows the non-invasive transcranial SW may have potential for the treatment of GBM in future clinical setting.

7.
Ultrason Sonochem ; 78: 105730, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34464899

RESUMEN

The blood-cerebrospinal fluid barrier (BCSFB) is another gatekeeper between systemic circulation and the central nervous system (CNS), mainly present at the boundary between choroid plexuses and the ventricular system. This study demonstrates BCSFB opening in rats by single pulse of low-energy focused shockwave (FSW, energy flux density 0.03 mJ/mm2, 2 × 106 microbubbles/kg) treatment at lateral ventricle, resulting in significantly elevated cerebrospinal fluid (CSF) concentrations of systemically-administered gastrodin (GTD) (4 times vs. control within 3 hrs) that remained detectable for 24 hrs. The FSW-GTD group had significantly lower Racine's scale (<4) and zero mortality (n = 30) after lithium-pilocarpine-induced epilepsy. Electrophysiological recordings showed decreased epileptiform discharges, and brain section histology revealed reduced inflammation, oxidative stress and apoptosis, when compared with groups without FSW (Racine's scale: 4 ∼ 5; mortality: 26.67 ∼ 36.67%). FSW-mediated BCSFB opening provides a promising alternative for controlled-delivery of therapeutics into the CNS, offering rapid and widespread medication distribution. The technique could by applied in the development of novel therapies for various CNS diseases.


Asunto(s)
Alcoholes Bencílicos , Barrera Hematoencefálica , Epilepsia , Glucósidos , Animales , Alcoholes Bencílicos/administración & dosificación , Plexo Coroideo/efectos de los fármacos , Plexo Coroideo/metabolismo , Epilepsia/tratamiento farmacológico , Epilepsia/metabolismo , Glucósidos/administración & dosificación , Ratas
8.
Micromachines (Basel) ; 12(4)2021 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-33917518

RESUMEN

This paper reports a transwell insert-embedded microfluidic device capable of culturing cells at an air-liquid interface (ALI), mimicking the in vivo alveolar epithelium microenvironment. Integration of a commercially available transwell insert makes the device fabrication straightforward and eliminates the tedious device assembly processes. The transwell insert can later be detached from the device for high-resolution imaging of the cells. In the experiments, the cells showing type-I pneumocyte markers are exploited to construct an in vitro alveolar epithelium model, and four culture conditions including conventional liquid/liquid culture (LLC) and air-liquid interface (ALI) cell culture in normal growth medium, and ALI cell culture with inflammatory cytokine (TNF-α) stimulation and ethanol vapor exposure are applied to investigate their effects on the alveolar epithelium barrier function. The barrier permeability is time-lapse monitored using trans-epithelial electrical resistance (TEER) measurement and immunofluorescence staining of the tight junction protein (ZO-1). The results demonstrate the functionalities of the device, and further show the applications and advantages of the constructed in vitro cell models for the lung studies.

9.
J Adv Res ; 26: 15-28, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33133680

RESUMEN

INTRODUCTION: Numerous studies have shown the ability of low-energy acoustic waves such as focused ultrasound or shockwave to transiently open blood-brain barrier (BBB) and facilitate drug delivery to the brain. Preclinical and clinical evidences have well demonstrated the efficacy and safety in treating various brain disorders. However, the molecular mechanisms of acoustic waves on the BBB are still not fully understood. OBJECTIVES: The present study aimed at exploring the possible molecular mechanisms of acoustic wave stimulation on brains. METHODS BRIEFLY DESCRIBE THE EXPERIMENTAL DESIGN: The left hemisphere of the rat's brain was treated with pulsed ultrasound from a commercial focused shockwave or a planar ultrasound device, and the right hemisphere served as a control. One hour after the mechanical wave stimulation or overnight, the rats were sacrificed and the brains were harvested for protein or histological analysis. Agonists and antagonists related to the signal transduction pathways of tight junction proteins were used to investigate the possible intracellular mechanisms. RESULTS: Intracellular signal transduction analysis shows calcium influx through transient receptor potential vanilloid 4 (TRPV4) channels, and the activation of PKC-δ pathway to mediate dissociation of ZO-1 and occludin after acoustic wave stimulation. The activation of TRPV4 or PKC-δ signaling further increased the expression level of TRPV4, suggesting a feedback loop to regulate BBB permeability. Moreover, the tight junction proteins dissociation can be reversed by administration of PKC-δ inhibitor and TRPV4 antagonist. CONCLUSION: The present study shows the crucial role of TRPV4 in acoustic wave-mediated BBB permeability, specifically its effect on compromising tight junction proteins, ZO-1 and occludin. Our findings provide a new molecular perspective to explain acoustic wave-mediated BBB opening. Moreover, activation of TRPV4 by agonists may reduce the threshold intensity level of acoustic waves for BBB opening, which may prevent undesirable mechanical damages while maintaining efficient BBB opening.

10.
Artículo en Inglés | MEDLINE | ID: mdl-32478046

RESUMEN

Focused extracorporeal shockwave (FSW), one kind of focused high-intensity pulsed ultrasound, has been shown to induce blood-brain barrier (BBB) opening in targeted brain areas in rat animal models with minimal detrimental effects below threshold intensity levels or iterations. In the current study, we found that the thresholds could be further reduced by the addition of microbubbles (ultrasound contrast agents or UCA; SonoVue). FSW with 2 × 106 MBs/kg of UCA (20% of clinical dosage) at an intensity level of 0.1 (peak positive pressure 5.4 MPa; peak negative pressure -4.2 MPa; energy flux density 0.03 mJ/mm2) resulting in a 100% BBB opening rate without detectable hemorrhage or apoptosis in the brain. Significantly reduced free radical production was found compared with 0.5 MHz focused ultrasound at a peak negative pressure of 0.44 MPa (1% duty cycle and 4 × 107 MBs/kg of UCA). FSW devices offer advantages of commercial availability and high safety, and thus may facilitate future research and applications of focal BBB opening for oncological and pharmacological purposes.

11.
Int J Mol Sci ; 20(14)2019 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-31336919

RESUMEN

Because of limitations in the current understanding of the exact pathogenesis of tendinopathy, and the lack of an optimal experimental model, effective therapy for the disease is currently unavailable. This study aims to prove that repression of oxidative stress modulates the differentiation of tendon-derived cells (TDCs) sustaining excessive tensile strains, and proposes a novel bioreactor capable of applying differential tensile strains to cultured cells simultaneously. TDCs, including tendon-derived stem cells, tenoblasts, tenocytes, and fibroblasts, were isolated from the patellar tendons of Sprague‒Dawley rats. Cyclic uniaxial stretching with 4% or 8% strain at 0.5 Hz for 8 h was applied to TDCs. TDCs subjected to 8% strain were treated with epigallocatechin gallate (EGCG), piracetam, or no medication. Genes representing non-tenocyte lineage (Pparg, Sox9, and Runx2) and type I and type III collagen were analyzed by quantitative polymerase chain reaction. The 8% strain group showed increased expression of non-tenocyte lineage genes and type III/type I collagen ratios compared with the control and 4% strain groups, and the increased expression was ameliorated with addition of EGCG and piracetam. The model developed in this work could be applied to future research on the pathophysiology of tendinopathy and development of treatment options for the disease. Repression of oxidative stress diminishes the expression of genes indicating aberrant differentiation in a rat cell model, which indicates potential therapeutic intervention of tendinopathy, the often relentlessly degenerate condition.


Asunto(s)
Diferenciación Celular , Estrés Oxidativo , Tenocitos/citología , Tenocitos/metabolismo , Animales , Biomarcadores , Técnicas de Cultivo de Célula , Diferenciación Celular/genética , Expresión Génica , Inmunofenotipificación , Estrés Oxidativo/efectos de los fármacos , Fenotipo , Ratas , Tendinopatía/etiología , Tendinopatía/metabolismo , Tendinopatía/patología , Tendones/citología , Tendones/metabolismo , Tenocitos/efectos de los fármacos
12.
Micromachines (Basel) ; 10(6)2019 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-31208111

RESUMEN

This paper reports a biomimetic microfluidic device capable of reconstituting physiological physical microenvironments in lungs during fetal development for cell culture. The device integrates controllability of both hydrostatic pressure and cyclic substrate deformation within a single chip to better mimic the in vivo microenvironments. For demonstration, the effects of drug treatment and physical stimulations on surfactant protein C (SPC) expression of lung epithelial cells (A549) are studied using the device. The experimental results confirm the device's capability of mimicking in vivo microenvironments with multiple physical stimulations for cell culture applications. Furthermore, the results indicate the critical roles of physical stimulations in regulating cellular behaviors. With the demonstrated functionalities and performance, the device is expected to provide a powerful tool for further lung development studies that can be translated to clinical observation in a more straightforward manner. Consequently, the device is promising for construction of more in vitro physiological microenvironments integrating multiple physical stimulations to better study organ development and its functions.

13.
Sci Rep ; 9(1): 8234, 2019 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-31160651

RESUMEN

Proliferation and migration of endothelial cells play an important role in many biological activities, and they can be regulated by various microenvironmental factors. In this paper, a novel microfluidic collective cell migration assay is developed to study endothelial cell migration and proliferation under combinations of three oxygen conditions: normoxia, oxygen gradient, and hypoxia and three medium compositions: normal growth medium, the medium with cytochalasin-D for actin polymerization inhibition, and with YC-1 for hypoxia-inducible factor (HIF) inhibition. The microfluidic device designed in the paper allows cell patterns formed with consistent dimensions using laminar flow patterning. In addition, stable oxygen gradients can be generated within the device by a spatially confined chemical reaction method. The device can be operated in conventional cell incubators with minimal chemical reagents and instrumentation for practical applications. The results show directional collective cell migration of the endothelial cells under the oxygen gradients for all the medium compositions. The directional behavior has never been discussed before, and indicates critical roles of oxygen gradients in guiding endothelial cell migration during various biological activities. The developed assay provides a practical yet powerful tool for further in vitro study of endothelial cell behaviors under various physiological microenvironments.


Asunto(s)
Ensayos de Migración Celular , Movimiento Celular/efectos de los fármacos , Células Endoteliales de la Vena Umbilical Humana/citología , Microfluídica , Oxígeno/farmacología , Preparaciones Farmacéuticas/metabolismo , Proliferación Celular/efectos de los fármacos , Fluorescencia , Células Endoteliales de la Vena Umbilical Humana/efectos de los fármacos , Humanos
14.
Analyst ; 144(11): 3494-3504, 2019 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-31062784

RESUMEN

An oxygen gradient is a key variable influencing various biological activities in vivo, such as tissue repair and tumor growth. To study the phenomenon, in vitro cell studies using microfluidic devices capable of generating oxygen gradients have been developed recently. However, it is challenging to accurately measure the gradient profiles in devices. The traditional fluorescence intensity-based method suffers from the difficulty of accurate measurement due to background fluorescence artefacts. In addition, it is hard to obtain accurate calibration conditions because of the difficulties to achieve a fully depleted and saturated oxygen concentrations in the devices. To overcome these difficulties, a widefield frequency domain fluorescence imaging microscopy (FD-FLIM) system was constructed and utilized to accurately measure oxygen gradient profiles in a microfluidic device in this paper. Since lifetime-based measurements do not solely depend on intensity variations, oxygen calibration processes are amiable and the measured oxygen concentrations can be more accurate. The performance of the FD-FLIM system was validated by comparing the experimental and simulation results in microfluidic devices with different geometries. The experimental results show that the oxygen gradients generated from the chemical reaction method can provide more hypoxic oxygen conditions compared to the gradients created by the gas flowing method. Owing to the advantages provided by the widefield microscopy technique, the image acquisition time can be significantly reduced resulting in less photobleaching for time-lapsed imaging applications. Consequently, the measurement technique developed in this paper is an efficient tool, which can greatly help scientists to better study biological activities under various oxygen conditions.

15.
Sci Rep ; 9(1): 4784, 2019 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-30886307

RESUMEN

Resulting from accumulative microtrauma, impaired healing and oxidative stress, tendinopathy is a debilitating and relentlessly deteriorating disease that greatly affects daily function and quality of life. Current therapy usually provides symptomatic relief only. Sufferers undergo repetitive and protracted treatment courses that rarely alter the disease process. We aim to develop a sustained-release regimen with an intrinsic therapeutic effect in tendinopathy treatment, using oxidised hyaluronic acid/adipic acid dihydrazide hydrogel (HA hydrogel) as both the drug carrier and a mitigating agent of symptoms. We show that HA hydrogel can mitigate tendinopathy changes both in vitro (mechanically induced tendinopathy model) and in vivo (collagenase-induced tendinopathy model). A potent anti-oxidative (pigallocatechin gallate) incorporated into HA hydrogel conferred an additional protective effect in both models. The results indicate that when administered early, combined medications targeting different pathogenesis pathways can resolve tendinopathy. Although facilitating the healing process and mitigating oxidative stress are promising therapeutic strategies, the most effective regimen for tendinopathy treatment has to be determined yet. The established experimental model and drug carrier system provide a platform for exploring new therapeutics against this debilitating disease.


Asunto(s)
Antioxidantes/administración & dosificación , Catequina/análogos & derivados , Ácido Hialurónico/química , Hidrogeles/química , Tendinopatía/terapia , Adipatos/química , Animales , Antioxidantes/uso terapéutico , Catequina/administración & dosificación , Catequina/uso terapéutico , Células Cultivadas , Portadores de Fármacos/química , Liberación de Fármacos , Ratas , Ratas Sprague-Dawley
16.
J Vis Exp ; (139)2018 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-30272670

RESUMEN

Polydimethylsiloxane (PDMS) materials are substantially exploited to fabricate microfluidic devices by using soft lithography replica molding techniques. Customized channel layout designs are necessary for specific functions and integrated performance of microfluidic devices in numerous biomedical and chemical applications (e.g., cell culture, biosensing, chemical synthesis, and liquid handling). Owing to the nature of molding approaches using silicon wafers with photoresist layers patterned by photolithography as master molds, the microfluidic channels commonly have regular cross sections of rectangular shapes with identical heights. Typically, channels with multiple heights or different geometric sections are designed to possess particular functions and to perform in various microfluidic applications (e.g., hydrophoresis is used for sorting particles and in continuous flows for separating blood cells6 , 7 , 8 , 9). Therefore, a great deal of effort has been made in constructing channels with various sections through multiple-step approaches like photolithography using several photoresist layers and assembly of different PDMS thin sheets. Nevertheless, such multiple-step approaches usually involve tedious procedures and extensive instrumentation. Furthermore, the fabricated devices may not perform consistently and the resulted experimental data may be unpredictable. Here, a one-step approach is developed for the straightforward fabrication of microfluidic channels with different geometric cross sections through PDMS sequential wet etching processes, that introduces etchant into channels of planned single-layer layouts embedded in PDMS materials. Compared to the existing methods for manufacturing PDMS microfluidic channels with different geometries, the developed one-step approach can significantly simplify the process to fabricate channels with non-rectangular sections or various heights. Consequently, the technique is a way of constructing complex microfluidic channels, which provides a fabrication solution for the advancement of innovative microfluidic systems.


Asunto(s)
Dispositivos Laboratorio en un Chip/normas , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos
17.
Ultrasound Med Biol ; 44(6): 1257-1265, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29549974

RESUMEN

Sonoporation, the use of ultrasound to alter the permeability of cell membranes, is a non-viral technique used to facilitate gene delivery, possibly by opening transient pores in the cell membrane. However, sonoporation may have negative bio-effects on cells, such as causing apoptosis, which limits its efficacy in gene delivery. In this study, we investigated whether pre-treatment with either L-carnitine or piracetam could protect cells from undergoing apoptosis after sonoporation and the possible mechanisms. We found that either L-carnitine or piracetam can promote gene transfection without reducing cell viability, possibly by reducing cavitation-induced reactive oxygen species generation, reversing alterations of mitochondrial membrane potential, preventing caspase-3/7 activity and facilitating mitochondrial ATP production. In conclusion, pre-treatment with either L-carnitine or piracetam could protect cells from sonoporation-associated apoptosis by preserving mitochondrial function.


Asunto(s)
Apoptosis , Carnitina/administración & dosificación , Piracetam/administración & dosificación , Transfección/métodos , Ondas Ultrasónicas , Animales , Permeabilidad de la Membrana Celular , Supervivencia Celular , Células Cultivadas , Ratones , Ratones Endogámicos BALB C , Nootrópicos/administración & dosificación
18.
Sci Rep ; 8(1): 2218, 2018 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-29396523

RESUMEN

Despite extensive efforts in recent years, the blood-brain barrier (BBB) remains a significant obstacle for drug delivery. This study proposes using a clinical extracorporeal shockwave instrument to open the BBB, combined with a laser assisted bi-axial locating platform to achieve non-invasive, controllable-focus and reversible BBB opening in the brains of rats. Under shockwave treatment with an intensity level of 5 (P-9.79 MPa, energy flux density (EFD) 0.21 mJ/mm2) and a pulse repetition frequency of 5 Hz, the BBB could be opened after 50 shocks without the use of an ultrasound contrast agent. With the proposed method, the BBB opening can be precisely controlled in terms of depth, size and location. Moreover, a shockwave based gene transfection was demonstrated using a luciferase gene.


Asunto(s)
Barrera Hematoencefálica/efectos de la radiación , Tratamiento con Ondas de Choque Extracorpóreas/métodos , Terapia Genética/métodos , Ondas de Choque de Alta Energía , Transfección , Animales , Encéfalo/efectos de la radiación , Genes Reporteros , Luciferasas/análisis , Luciferasas/genética , Ratas
19.
Anal Chem ; 90(3): 2317-2325, 2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29293313

RESUMEN

This paper reports a microfluidic viscometer with an integrated pressure sensor based on electrofluidic circuits, which are electrical circuits constructed by ionic liquid-filled microfluidic channels. The electrofluidic circuit provides a pressure-sensing scheme with great long-term and thermal stability. The viscosity of the tested fluidic sample is estimated by its flow resistance, which is a function of pressure drop, flow rate, and the geometry of the microfluidic channel. The viscometer can be exploited to measure viscosity of either Newtonian or non-Newtonian power-law fluid under various shear rates (3-500 1/s) and temperatures (4-70 °C) with small sample volume (less than 400 µL). The developed sensor-integrated microfluidic viscometer is made of poly(dimethylsiloxane) (PDMS) with transparent electrofluidic circuit, which makes it feasible to simultaneously image samples under tests. In addition, the entire device is disposable to prevent cross-contamination between samples, which is desired for various chemical and biomedical applications. In the experiments, viscosities of Newtonian fluids, glycerol water solutions with different concentrations and a mixture of pyrogallol and sodium hydroxide (NaOH), and non-Newtonian fluids, xanthan gum solutions and human blood samples, have been characterized. The results demonstrate that the developed microfluidic viscometer provides a convenient and useful platform for practical viscosity characterization of fluidic samples for a wide variety of applications.

20.
J Vis Exp ; (120)2017 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-28287582

RESUMEN

This paper reports a microfluidic device made of polydimethylsiloxane (PDMS) with an embedded polycarbonate (PC) thin film to study cell migration under combinations of chemical and oxygen gradients. Both chemical and oxygen gradients can greatly affect cell migration in vivo; however, due to technical limitations, very little research has been performed to investigate their effects in vitro. The device developed in this research takes advantage of a series of serpentine-shaped channels to generate the desired chemical gradients and exploits a spatially confined chemical reaction method for oxygen gradient generation. The directions of the chemical and oxygen gradients are perpendicular to each other to enable straightforward migration result interpretation. In order to efficiently generate the oxygen gradients with minimal chemical consumption, the embedded PC thin film is utilized as a gas diffusion barrier. The developed microfluidic device can be actuated by syringe pumps and placed into a conventional cell incubator during cell migration experiments to allow for setup simplification and optimized cell culture conditions. In cell experiments, we used the device to study migrations of adenocarcinomic human alveolar basal epithelial cells, A549, under combinations of chemokine (stromal cell-derived factor, SDF-1α) and oxygen gradients. The experimental results show that the device can stably generate perpendicular chemokine and oxygen gradients and is compatible with cells. The migration study results indicate that oxygen gradients may play an essential role in guiding cell migration, and cellular behavior under combinations of gradients cannot be predicted from those under single gradients. The device provides a powerful and practical tool for researchers to study interactions between chemical and oxygen gradients in cell culture, which can promote better cell migration studies in more in vivo-like microenvironments.


Asunto(s)
Técnicas de Cultivo de Célula/instrumentación , Dimetilpolisiloxanos , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Microfluídica/instrumentación , Oxígeno/análisis , Ensayos de Migración Celular , Movimiento Celular , Diseño de Equipo , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...