Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Occup Environ Med ; 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38788162

RESUMEN

OBJECTIVE: To study infection, hospitalisation, and admission to ICU for COVID-19 in different occupations and pandemic waves in a Swedish county. METHODS: Individual registry data of infection and hospitalisation were merged with occupational data in, this cross-sectional study. Infected, hospital- and ICU-admission were analysed by occupational groups. RESULTS: 22,095 cases of COVID-19 from 21 February 2021 to 31 August 2022 were identified. Healthcare workers and others working in close physical proximity showed a higher rate of confirmed COVID-19 infections in all waves and higher risk for hospital admission early in the pandemic. Exposure to diseases and physical proximity played a decisive role. CONCLUSION: Workers in close-contact occupations experienced a higher rate of confirmed infections throughout the pandemic and higher hospitalisation rates in the first pandemic wave, suggesting a need for more effective initial safety measures in a future pandemic.

2.
BMJ Case Rep ; 17(2)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38331446

RESUMEN

A woman in her 80s experienced a life-threatening complication of pacemaker implant consisting of subacute right ventricular lead perforation causing iatrogenic injury to an intercostal artery, resulting in a large haemothorax. A CT scan confirmed active bleeding from the fourth intercostal artery. The patient underwent cardiothoracic surgery via a median sternotomy approach, during which the source of the bleeding was sealed, a new epicardial lead was positioned, and the original lead was extracted. This case emphasises the potentially severe consequences of pacemaker lead perforation and secondary injury to adjacent structures. It underscores the importance of early recognition and timely intervention, preferably in a tertiary specialist unit equipped for cardiothoracic surgery and confirms the value of pacemaker interrogation and CT scans for diagnosis.


Asunto(s)
Lesiones Cardíacas , Marcapaso Artificial , Femenino , Humanos , Arterias , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/cirugía , Hemorragia/diagnóstico por imagen , Hemorragia/etiología , Hemorragia/terapia , Hemotórax/diagnóstico por imagen , Hemotórax/etiología , Hemotórax/cirugía , Enfermedad Iatrogénica , Marcapaso Artificial/efectos adversos , Anciano de 80 o más Años
3.
Eur Radiol ; 34(1): 39-49, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37552259

RESUMEN

OBJECTIVES: Quantitative CT imaging is an important emphysema biomarker, especially in smoking cohorts, but does not always correlate to radiologists' visual CT assessments. The objectives were to develop and validate a neural network-based slice-wise whole-lung emphysema score (SWES) for chest CT, to validate SWES on unseen CT data, and to compare SWES with a conventional quantitative CT method. MATERIALS AND METHODS: Separate cohorts were used for algorithm development and validation. For validation, thin-slice CT stacks from 474 participants in the prospective cross-sectional Swedish CArdioPulmonary bioImage Study (SCAPIS) were included, 395 randomly selected and 79 from an emphysema cohort. Spirometry (FEV1/FVC) and radiologists' visual emphysema scores (sum-visual) obtained at inclusion in SCAPIS were used as reference tests. SWES was compared with a commercially available quantitative emphysema scoring method (LAV950) using Pearson's correlation coefficients and receiver operating characteristics (ROC) analysis. RESULTS: SWES correlated more strongly with the visual scores than LAV950 (r = 0.78 vs. r = 0.41, p < 0.001). The area under the ROC curve for the prediction of airway obstruction was larger for SWES than for LAV950 (0.76 vs. 0.61, p = 0.007). SWES correlated more strongly with FEV1/FVC than either LAV950 or sum-visual in the full cohort (r = - 0.69 vs. r = - 0.49/r = - 0.64, p < 0.001/p = 0.007), in the emphysema cohort (r = - 0.77 vs. r = - 0.69/r = - 0.65, p = 0.03/p = 0.002), and in the random sample (r = - 0.39 vs. r = - 0.26/r = - 0.25, p = 0.001/p = 0.007). CONCLUSION: The slice-wise whole-lung emphysema score (SWES) correlates better than LAV950 with radiologists' visual emphysema scores and correlates better with airway obstruction than do LAV950 and radiologists' visual scores. CLINICAL RELEVANCE STATEMENT: The slice-wise whole-lung emphysema score provides quantitative emphysema information for CT imaging that avoids the disadvantages of threshold-based scores and is correlated more strongly with reference tests than LAV950 and reader visual scores. KEY POINTS: • A slice-wise whole-lung emphysema score (SWES) was developed to quantify emphysema in chest CT images. • SWES identified visual emphysema and spirometric airflow limitation significantly better than threshold-based score (LAV950). • SWES improved emphysema quantification in CT images, which is especially useful in large-scale research.


Asunto(s)
Obstrucción de las Vías Aéreas , Enfisema , Enfermedad Pulmonar Obstructiva Crónica , Enfisema Pulmonar , Humanos , Estudios Prospectivos , Estudios Transversales , Enfisema Pulmonar/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Enfisema/diagnóstico por imagen , Obstrucción de las Vías Aéreas/diagnóstico por imagen
4.
Acta Radiol ; 65(3): 307-317, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38115809

RESUMEN

BACKGROUND: Magnetic resonance imaging (MRI) is useful in the diagnosis of clinically significant prostate cancer (csPCa). MRI-derived radiomics may support the diagnosis of csPCa. PURPOSE: To investigate whether adding radiomics from biparametric MRI to predictive models based on clinical and MRI parameters improves the prediction of csPCa in a multisite-multivendor setting. MATERIAL AND METHODS: Clinical information (PSA, PSA density, prostate volume, and age), MRI reviews (PI-RADS 2.1), and radiomics (histogram and texture features) were retrieved from prospectively included patients examined at different radiology departments and with different MRI systems, followed by MRI-ultrasound fusion guided biopsies of lesions PI-RADS 3-5. Predictive logistic regression models of csPCa (Gleason score ≥7) for the peripheral (PZ) and transition zone (TZ), including clinical data and PI-RADS only, and combined with radiomics, were built and compared using receiver operating characteristic (ROC) curves. RESULTS: In total, 456 lesions in 350 patients were analyzed. In PZ and TZ, PI-RADS 4-5 and PSA density, and age in PZ, were independent predictors of csPCa in models without radiomics. In models including radiomics, PI-RADS 4-5, PSA density, age, and ADC energy were independent predictors in PZ, and PI-RADS 5, PSA density and ADC mean in TZ. Comparison of areas under the ROC curve (AUC) for the models without radiomics (PZ: AUC = 0.82, TZ: AUC = 0.80) versus with radiomics (PZ: AUC = 0.82, TZ: AUC = 0.82) showed no significant differences (PZ: P = 0.366; TZ: P = 0.171). CONCLUSION: PSA density and PI-RADS are potent predictors of csPCa. Radiomics do not add significant information to our multisite-multivendor dataset.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Antígeno Prostático Específico , Radiómica , Curva ROC , Estudios Retrospectivos
5.
Urolithiasis ; 51(1): 66, 2023 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-37027057

RESUMEN

We aimed to externally validate five previously published predictive models (Ng score, Triple D score, S3HoCKwave score, Kim nomogram, Niwa nomogram) for shock wave lithotripsy (SWL) single-session outcomes in patients with a solitary stone in the upper ureter. The validation cohort included patients treated with SWL from September 2011 to December 2019 at our institution. Patient-related variables were retrospectively collected from the hospital records. Stone-related data including all measurements were retrieved from computed tomography prior to SWL. We estimated discrimination using area under the curve (AUC), calibration, and clinical net benefit based on decision curve analysis (DCA). A total of 384 patients with proximal ureter stones treated with SWL were included in the analysis. Median age was 55.5 years, and 282 (73%) of the sample were men. Median stone length was 8.0 mm. All models significantly predicted the SWL outcomes after one session. S3HoCKwave score, Niwa, and Kim nomograms had the highest accuracy in predicting outcomes, with AUC 0.716, 0.714 and 0.701, respectively. These three models outperformed both the Ng (AUC: 0.670) and Triple D (AUC: 0.667) scoring systems, approaching statistical significance (P = 0.05). Of all the models, the Niwa nomogram showed the strongest calibration and highest net benefit in DCA. To conclude, the models showed small differences in predictive power. The Niwa nomogram, however, demonstrated acceptable discrimination, the most accurate calibration, and the highest net benefit whilst having relatively simple design. Therefore, it could be useful for counselling patients with a solitary stone in the upper ureter.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Masculino , Humanos , Persona de Mediana Edad , Femenino , Cálculos Ureterales/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Litotricia/métodos , Cálculos Renales/terapia
6.
Acta Radiol ; 64(5): 1859-1864, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36749001

RESUMEN

The Swedish Society of Uroradiology has revised their computed tomography (CT) guidelines regarding iodine contrast media-induced acute kidney injury (CI-AKI). They are more cautious compared to the European Society of Urogenital Radiology and the American College of Radiology since the actual risk of CI-AKI remains uncertain in patients with moderate to severe kidney damage due to a lack of prospective controlled studies and mainly based on retrospective propensity score-matched studies with low-grade evidence. Another source of uncertainty is the imprecision of glomerular filtration rate (GFR) estimating equations. However, randomized hydration studies indictae an upper limit risk of CI-AKI of about 5% for outpatients with a GFR in the range of 30-44 or 45-59 mL/min/1.73m2 combined with multiple risk factors. Apart from GFR limits, the guideline also includes limits for systemic contrast medium exposure expressed in gram-iodine/GFR ratio.


Asunto(s)
Lesión Renal Aguda , Yodo , Humanos , Yodo/efectos adversos , Suecia , Estudios Retrospectivos , Lesión Renal Aguda/inducido químicamente , Radiografía , Medios de Contraste/efectos adversos , Factores de Riesgo , Tasa de Filtración Glomerular
7.
Front Immunol ; 13: 945603, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35967397

RESUMEN

Uncontrolled release of damage-associated molecular patterns (DAMPs) is suggested to be a major trigger for the dysregulated host immune response that leads to severe COVID-19. Cold-inducible RNA-binding protein (CIRP), is a newly identified DAMP that aggravates inflammation and tissue injury, and induces respiratory failure in sepsis. Whether CIRP contributes to the pathogenesis of respiratory failure in COVID-19 has not yet been explored. Aim: To investigate if the concentration of extracellular CIRP (eCIRP) in serum associates with respiratory failure and lung involvement by chest computed tomography (CT) in COVID-19. Methods: Herein we report a prospective observational study of patients with COVID-19 included at two University Hospitals in Sweden between April 2020 and May 2021. Serum from hospitalized patients in Örebro (N=97) were used to assess the association between eCIRP and the level of respiratory support and its correlation with pulmonary involvement on chest CT and inflammatory biomarkers. A cohort of hospitalized and non-hospitalized patients from Umeå (N=78) was used as an external validation cohort. The severity of disease was defined according to the highest degree of respiratory support; mild disease (no oxygen), non-severe hypoxemia (conventional oxygen or high-flow nasal oxygen, HFNO <50% FiO2), and severe hypoxemia (HFNO ≥50% FiO2, mechanical ventilation). Unadjusted and adjusted linear regression was used to evaluate peak eCIRP day 0-4 in respect to severity, age, sex, Charlson comorbidity score, symptom duration, and BMI. Results: Peak eCIRP concentrations were higher in patients with severe hypoxemia and were independently associated with the degree of respiratory support in both cohorts (Örebro; p=0.01, Umeå; p<0.01). The degree of pulmonary involvement measured by CT correlated with eCIRP, rs=0.30, p<0.01 (n=97). Conclusion: High serum levels of eCIRP are associated with acute respiratory failure in COVID-19. Experimental studies are needed to determine if treatments targeting eCIRP reduces the risk of acute respiratory failure in COVID-19.


Asunto(s)
COVID-19 , Síndrome de Dificultad Respiratoria , Insuficiencia Respiratoria , Alarminas , Humanos , Hipoxia/complicaciones , Oxígeno , Proteínas de Unión al ARN , Insuficiencia Respiratoria/etiología
8.
Infect Dis (Lond) ; 54(6): 431-440, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35114897

RESUMEN

BACKGROUND: COVID-19 has a most variable prognosis. Several risk factors for an unfavourable outcome have been identified including extensive lung involvement on chest CT and high viral load estimated by RT-PCR cycle threshold (Ct) values. We investigated Ct value for outcome prediction, relation between Ct value and extent of lung involvement on chest CT and the combination of Ct value and chest CT lung involvement to predict outcome in COVID-19. METHODS: Population-based retrospective study on all patients (n = 286) hospitalised for COVID-19 in Örebro Region, Sweden, between 1 March and 31 August 2020. Nasopharyngeal samples and chest CT at hospital admission were evaluated in relation to outcome of COVID-19. RESULTS: Both Ct value and chest CT lung involvement were independently associated with risk for ICU admission or death. Lung involvement was superior as a single parameter, but addition of Ct value increased the prediction performance. Ct value was especially useful to identify patients with high risk for severe disease despite limited lung involvement. CONCLUSIONS: The addition of RT-PCR Ct value to the assessment of lung involvement on chest CT adds valuable prognostic information in COVID-19. We believe that this information can be used to support clinical decision-making when managing COVID-19 patients.


Asunto(s)
COVID-19 , COVID-19/diagnóstico por imagen , Hospitales , Humanos , Pulmón/diagnóstico por imagen , Estudios Retrospectivos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2 , Tomografía Computarizada por Rayos X/métodos
9.
J Card Surg ; 36(10): 3702-3708, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34312919

RESUMEN

BACKGROUND: Randomized trials show high long-term patency for no-touch saphenous vein grafts in coronary artery bypass grafting. The patency rate in off-pump coronary bypass surgery for these grafts has not been investigated. Our center participated in the CORONARY randomized trial, NCT00463294. This is a study aimed to assess the patency of no-touch saphenous veins in on- versus off-pump coronary bypass surgery at five-year follow-up. METHODS: Fifty-six patients were included. Forty of 49 patients, alive at 5 years, participated in this follow-up. There were 21 and 19 patients in the on- and off-pump groups respectively. No-touch saphenous veins were used to bypass all targets and in some cases the left anterior descending artery. Graft patency according to distal anastomosis was evaluated with computed tomography angiography. RESULTS: The five-year patency rate was 123/139 (88.5%). The patency for the no-touch vein grafts was 57/64 (89.1%) in the on-pump versus 37/45 (82.2%) in the off-pump group. All left internal thoracic arteries except for one, 29/30 (96.6%), were patent. All vein grafts used to bypass the left anterior descending and the diagonal arteries were patent 32/32. The lowest patency rate for the saphenous veins was to the right coronary territory, particularly in off-pump surgery (80.0% vs. 62.5% for the on- respective off-pump groups). CONCLUSIONS: Comparable 5-year patency for the no-touch saphenous veins and the left internal thoracic arteries to the left anterior descending territory in both on- and off-pump coronary artery bypass grafting. Graft patency in off-pump CABG is lower to the right coronary artery.


Asunto(s)
Arterias Mamarias , Angiografía Coronaria , Puente de Arteria Coronaria , Humanos , Vena Safena/diagnóstico por imagen , Resultado del Tratamiento , Grado de Desobstrucción Vascular
10.
Eur J Radiol Open ; 8: 100357, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34095355

RESUMEN

BACKGROUND: Patients with transfusion dependent anemia are at risk of complications from iron overload. Quantitative T2* magnetic resonance imaging (MRI) is the best non-invasive method to assess iron deposition in the liver and heart and to guide chelation therapy. PURPOSE: To investigate the image quality and inter-observer variations in T2* measurements of the myocardium and the liver, and to obtain the lower limit of cardiac and hepatic quantitative T2* values in patients without suspicion of iron overload. MATERIAL AND METHODS: Thirty-eight patients referred for cardiac MRI were prospectively included in the study. Three patients were referred with, and 35 without suspicion of iron overload. Quantitative T2* parametric maps were obtained on a 1.5 T MRI system in the cardiac short axis and liver axial view. Two readers independently assessed the image quality and the representative and the lowest T2* value in the myocardium and the liver. RESULTS: The normal range of representative T2* values in the myocardium and liver was 24-45 ms and 14-37 ms, respectively. None of the 35 participants (0 %, 95 % confidence interval 0-11 %) in the normal reference group demonstrated representative T2* values below previously reported lower limits in the myocardium (20 ms) or the liver (8 ms). Focal myocardial areas with T2* values near the lower normal range, 19-20 ms, were seen in two patients. The readers generally reported good image quality. CONCLUSION: T2* imaging for assessing iron overload can be performed in a non-dedicated center with sufficient image quality.

11.
Infect Dis (Lond) ; 53(8): 622-632, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33848219

RESUMEN

BACKGROUND: Chest CT is prognostic in Covid-19 but there is a lack of consensus on how to report the CT findings. A chest CT scoring system, ÖCoS, was implemented in clinical routine on 1 April 2020, in Örebro Region, Sweden. The ÖCoS-severity score measures the extent of lung involvement. The objective of the study was to evaluate the ÖCoS scores as predictors of the clinical course of Covid-19. METHODS: Population based study including data from all hospitalized patients with Covid-19 in Örebro Region during March to July 2020. We evaluated the correlations between CT scores at the time of admission to hospital and intensive care in relation to hospital and intensive care length of stay (LoS), intensive care admission and death. C-reactive protein and lymphocyte count were included as covariates in multivariate regression analyses. RESULTS: In 381 included patients, the ÖCoS-severity score at admission closely correlated to hospital length of stay, and intensive care admission or death. At admission to intensive care, the ÖCoS-severity score correlated with intensive care length of stay. The ÖCoS-severity score was superior to basic inflammatory biomarkers in predicting clinical outcomes. CONCLUSION: Chest CT visual scoring at admission to hospital predicted the clinical course of Covid-19 pneumonia.


Asunto(s)
COVID-19 , Cuidados Críticos , Hospitalización , Hospitales , Humanos , Estudios Retrospectivos , SARS-CoV-2 , Suecia , Tomografía Computarizada por Rayos X
12.
Eur Radiol ; 31(8): 5980-5989, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33635394

RESUMEN

OBJECTIVES: To prospectively validate three quantitative single-energy CT (SE-CT) methods for classifying uric acid (UA) and non-uric acid (non-UA) stones. METHODS: Between September 2018 and September 2019, 116 study participants were prospectively included in the study if they had at least one 3-20-mm urinary stone on an initial urinary tract SE-CT scan. An additional dual-energy CT (DE-CT) scan was performed, limited to the stone of interest. Additionally, to include a sufficient number of UA stones, eight participants with confirmed UA stone on DE-CT were retrospectively included. The SE-CT stone features used in the prediction models were (1) maximum attenuation (maxHU) and (2) the peak point Laplacian (ppLapl) calculated at the position in the stone with maxHU. Two prediction models were previously published methods (ppLapl-maxHU and maxHU) and the third was derived from the previous results based on the k-nearest neighbors (kNN) algorithm (kNN-ppLapl-maxHU). The three methods were evaluated on this new independent stone dataset. The reference standard was the CT vendor's DE-CT application for kidney stones. RESULTS: Altogether 124 participants (59 ± 14 years, 91 men) with 106 non-UA and 37 UA stones were evaluated. For classification of UA and non-UA stones, the sensitivity, specificity, and accuracy were 100% (37/37), 97% (103/106), and 98% (140/143), respectively, for kNN-ppLapl-maxHU; 95% (35/37), 98% (104/106), and 97% (139/143) for ppLapl-maxHU; and 92% (34/37), 94% (100/106), and 94% (134/143) for maxHU. CONCLUSION: A quantitative SE-CT method (kNN-ppLapl-maxHU) can classify UA stones with accuracy comparable to DE-CT. KEY POINTS: • Single-energy CT is the first-line diagnostic tool for suspected renal colic. • A single-energy CT method based on the internal urinary stone attenuation distribution can classify urinary stones into uric acid and non-uric acid stones with high accuracy. • This immensely increases the availability of in vivo stone analysis.


Asunto(s)
Ácido Úrico , Cálculos Urinarios , Humanos , Masculino , Estudios Prospectivos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Cálculos Urinarios/diagnóstico por imagen
13.
Asian Cardiovasc Thorac Ann ; 29(6): 490-497, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33334128

RESUMEN

OBJECTIVE: Concerns have been raised regarding whether skeletonization of the internal thoracic artery could damage the graft and thereby reduces its patency. The objective of this study was to compare patency rates at mid- and long-term follow-up between pedicled and skeletonized left internal thoracic artery grafts. METHODS: This randomized controlled trial included 109 patients undergoing coronary artery bypass surgery. The patients were assigned to receive either one pedicled or one skeletonized left internal thoracic artery graft to the left anterior descending artery. Follow-up was performed at 3 years with conventional angiography, and at 8 years with computed tomography angiography. Differences between patency rates were analyzed with Fisher's exact test and a generalized linear model. RESULTS: The patency rates for pedicled and skeletonized left internal thoracic artery grafts were 46/48 (95.8%) versus 47/52 (90.4%), p = 0.44 at 3 years, and 40/43 (93.0%) versus 37/41 (90.2%), p = 0.71 at 8 years, respectively. The difference in patency rates for pedicled and skeletonized grafts was 5.4% (95% confidence interval: -4.2-14.5) at 3 years and 2.8% (95% confidence interval: -9.9-14.1) at 8 years. All failed grafts, except for one with a localized stenosis, were anastomosed to native coronary arteries with a stenosis less than 70%. Three patients suffered sternal wound infections (two in the pedicled group, one in the skeletonized group). CONCLUSIONS: The skeletonization technique can be used without jeopardizing the patency of the left internal thoracic artery. The most important factor in graft failure was target artery stenosis below 70%.


Asunto(s)
Arterias Mamarias , Constricción Patológica , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Humanos , Arterias Mamarias/diagnóstico por imagen , Arterias Mamarias/cirugía , Esternón , Resultado del Tratamiento , Grado de Desobstrucción Vascular
14.
J Thorac Cardiovasc Surg ; 161(2): 624-630, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-31831193

RESUMEN

BACKGROUND: In 2004, a prospective randomized trial demonstrated that after 3 years, saphenous veins (SVs) harvested with a no touch (NT) technique had a greater patency than radial grafts for coronary bypass surgery. Here we report the 8-year follow-up data of this trial. METHODS: The trial included 108 patients undergoing coronary artery bypass grafting (CABG). Each patient was assigned to receive 1 NT SV and 1 radial artery (RA) graft to either the left or right coronary territory to complement the left internal thoracic artery (LITA). Sequential grafting was common, so overall graft patency as well as the patency of each anastomosis were assessed. RESULTS: Angiography was performed in 84 patients (78%) at mean of 97 months postoperatively. Graft patency were high and similar for both NT and RA: 86% for NT versus 79% for RA (P = .22). The patency of coronary anastomoses was significantly higher with the NT SV grafts (91% vs 81%; P = .046). The NT grafts also had excellent patency in coronary arteries with <90% stenosis (93% patency) and in coronary arteries of small diameter (87% patency) or with mild calcification (88% patency). Patency for the LITA was 92%. CONCLUSIONS: NT SV grafts have excellent patency similar to that of RA grafts after 8 years. In addition, NT SV grafts can be used in situations that are not ideal for RA grafts.


Asunto(s)
Puente de Arteria Coronaria/métodos , Arteria Radial/trasplante , Vena Safena/trasplante , Adulto , Anciano , Angiografía por Tomografía Computarizada , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Arteria Radial/diagnóstico por imagen , Vena Safena/diagnóstico por imagen , Injerto Vascular/métodos , Grado de Desobstrucción Vascular
15.
Urolithiasis ; 49(1): 41-49, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32107579

RESUMEN

The objectives were to develop and validate a Convolutional Neural Network (CNN) using local features for differentiating distal ureteral stones from pelvic phleboliths, compare the CNN method with a semi-quantitative method and with radiologists' assessments and to evaluate whether the assessment of a calcification and its local surroundings is sufficient for discriminating ureteral stones from pelvic phleboliths in non-contrast-enhanced CT (NECT). We retrospectively included 341 consecutive patients with acute renal colic and a ureteral stone on NECT showing either a distal ureteral stone, a phlebolith or both. A 2.5-dimensional CNN (2.5D-CNN) model was used, where perpendicular axial, coronal and sagittal images through each calcification were used as input data for the CNN. The CNN was trained on 384 calcifications, and evaluated on an unseen dataset of 50 stones and 50 phleboliths. The CNN was compared to the assessment by seven radiologists who reviewed a local 5 × 5 × 5 cm image stack surrounding each calcification, and to a semi-quantitative method using cut-off values based on the attenuation and volume of the calcifications. The CNN differentiated stones and phleboliths with a sensitivity, specificity and accuracy of 94%, 90% and 92% and an AUC of 0.95. This was similar to a majority vote accuracy of 93% and significantly higher (p = 0.03) than the mean radiologist accuracy of 86%. The semi-quantitative method accuracy was 49%. In conclusion, the CNN differentiated ureteral stones from phleboliths with higher accuracy than the mean of seven radiologists' assessments using local features. However, more than local features are needed to reach optimal discrimination.


Asunto(s)
Redes Neurales de la Computación , Cólico Renal/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Cálculos Ureterales/diagnóstico , Calcificación Vascular/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Conjuntos de Datos como Asunto , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pelvis/irrigación sanguínea , Pelvis/diagnóstico por imagen , Curva ROC , Cólico Renal/etiología , Estudios Retrospectivos , Uréter/diagnóstico por imagen , Cálculos Ureterales/complicaciones , Calcificación Vascular/patología , Venas/diagnóstico por imagen , Venas/patología , Adulto Joven
16.
J Digit Imaging ; 33(5): 1185-1193, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32779016

RESUMEN

Emphysema is visible on computed tomography (CT) as low-density lesions representing the destruction of the pulmonary alveoli. To train a machine learning model on the emphysema extent in CT images, labeled image data is needed. The provision of these labels requires trained readers, who are a limited resource. The purpose of the study was to test the reading time, inter-observer reliability and validity of the multi-reader-multi-split method for acquiring CT image labels from radiologists. The approximately 500 slices of each stack of lung CT images were split into 1-cm chunks, with 17 thin axial slices per chunk. The chunks were randomly distributed to 26 readers, radiologists and radiology residents. Each chunk was given a quick score concerning emphysema type and severity in the left and right lung separately. A cohort of 102 subjects, with varying degrees of visible emphysema in the lung CT images, was selected from the SCAPIS pilot, performed in 2012 in Gothenburg, Sweden. In total, the readers created 9050 labels for 2881 chunks. Image labels were compared with regional annotations already provided at the SCAPIS pilot inclusion. The median reading time per chunk was 15 s. The inter-observer Krippendorff's alpha was 0.40 and 0.53 for emphysema type and score, respectively, and higher in the apical part than in the basal part of the lungs. The multi-split emphysema scores were generally consistent with regional annotations. In conclusion, the multi-reader-multi-split method provided reasonably valid image labels, with an estimation of the inter-observer reliability.


Asunto(s)
Enfisema Pulmonar , Femenino , Humanos , Pulmón , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Enfisema Pulmonar/diagnóstico por imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
17.
Br J Radiol ; 93(1111): 20190995, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32436788

RESUMEN

OBJECTIVES: To perform CT pulmonary angiography (CTPA) using a minimal amount of iodinated contrast media. METHODS: 47 patients (25 females) with mean age 69 years (range 41-82 years) referred for contrast-enhanced chest CT were prospectively included in this Phase IV clinical drug trial. All participants underwent a study specific CTPA in addition to the chest CT. The participants received 80 mg I/kg body weight Iohexol contrast media using a preparatory saline bolus, a dual flow contrast/saline bolus and a saline flush, and a scanner protocol with 80 kVp dual source high-pitch mode. Three readers independently assessed the image quality on the 3-point scale non-diagnostic, adequate or good-excellent image quality. Additionally, the pulmonary arterial contrast opacification was measured. RESULTS: On average, the patients received 16.8 ml Iohexol 350 mg I/mL (range 12-20 ml). Mean patient weight was 71 kg (range 50-85 kg). Identically for all readers, pulmonary embolism (PE) was detected in 1/47 participants. The median number of examinations visually scored concerning pulmonary embolism as good-excellent was 47/47 (range 44-47); adequate 0/47 (0-3) and non-diagnostic 0/47 (range 0-0). The proportion adequate or better examinations was for all readers 47/47, 100% [95% confidence interval 92-100%]. The mean attenuation ± standard deviation in the pulmonary trunk was 325 ± 72 Hounsfield unit (range 165-531 Hounsfield unit). CONCLUSIONS: Diagnostic CTPA with 17 ml contrast media is possible in non-obese patients using low kVp, high pitch and carefully designed contrast media administration. ADVANCES IN KNOWLEDGE: By combining several procedures in a CTPA protocol, the contrast media dose can be minimized.


Asunto(s)
Medios de Contraste/administración & dosificación , Yohexol/administración & dosificación , Embolia Pulmonar/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Protocolos Clínicos , Angiografía por Tomografía Computarizada/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen
18.
Eur J Radiol Open ; 7: 100228, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32258248

RESUMEN

PURPOSE: To quantify the interobserver variability among the most frequently encountered parenchymal patterns in High Resolution CT (HRCT) and to compare the interobserver variability in the application of the 2011 and 2018 usual interstitial pneumonia (UIP) criteria according to the joint guidelines from international thoracic and respiratory societies. MATERIAL AND METHODS: Two observers independently evaluated 126 HRCT, with examples of most common parenchymal patterns, and noted the presence of each pattern. The readers also noted whether the findings met the 2011 criteria for UIP. In a second reading, the same readers noted whether the HRCT met the UIP criteria according to the 2018 UIP update. RESULTS: The kappa values for interobserver variability for the different patterns ranged from 0.28 (intralobular lines) to 0.85 (tree-in-bud nodules). The kappa value for UIP pattern was similar for 2011 and 2018 criteria, 0.58 and 0.69, respectively. Compared to the 2011 UIP criteria, there was no statistically significant difference in the number of HRCT classified as UIP using the 2018 criteria. CONCLUSIONS: There is a substantial variation in interobserver agreement between the different parenchymal patterns, which suggests that some patterns a more easily identified than others. There is also a considerable reader variation in the assessment of UIP applying the 2011 UIP criteria as well as applying the 2018 UIP update.

19.
Comput Biol Med ; 97: 153-160, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29730498

RESUMEN

Computed tomography (CT) is the method of choice for diagnosing ureteral stones - kidney stones that obstruct the ureter. The purpose of this study is to develop a computer aided detection (CAD) algorithm for identifying a ureteral stone in thin slice CT volumes. The challenge in CAD for urinary stones lies in the similarity in shape and intensity of stones with non-stone structures and how to efficiently deal with large high-resolution CT volumes. We address these challenges by using a Convolutional Neural Network (CNN) that works directly on the high resolution CT volumes. The method is evaluated on a large data base of 465 clinically acquired high-resolution CT volumes of the urinary tract with labeling of ureteral stones performed by a radiologist. The best model using 2.5D input data and anatomical information achieved a sensitivity of 100% and an average of 2.68 false-positives per patient on a test set of 88 scans.


Asunto(s)
Redes Neurales de la Computación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Cálculos Ureterales/diagnóstico por imagen , Adulto , Algoritmos , Bases de Datos Factuales , Femenino , Humanos , Masculino , Aprendizaje Automático Supervisado
20.
Eur Radiol ; 28(6): 2474-2483, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29368161

RESUMEN

OBJECTIVES: To compare the ability of different size estimates to predict spontaneous passage of ureteral stones using a 3D-segmentation and to investigate the impact of manual measurement variability on the prediction of stone passage. METHODS: We retrospectively included 391 consecutive patients with ureteral stones on non-contrast-enhanced CT (NECT). Three-dimensional segmentation size estimates were compared to the mean of three radiologists' measurements. Receiver-operating characteristic (ROC) analysis was performed for the prediction of spontaneous passage for each estimate. The difference in predicted passage probability between the manual estimates in upper and lower stones was compared. RESULTS: The area under the ROC curve (AUC) for the measurements ranged from 0.88 to 0.90. Between the automated 3D algorithm and the manual measurements the 95% limits of agreement were 0.2 ± 1.4 mm for the width. The manual bone window measurements resulted in a > 20 percentage point (ppt) difference between the readers in the predicted passage probability in 44% of the upper and 6% of the lower ureteral stones. CONCLUSIONS: All automated 3D algorithm size estimates independently predicted the spontaneous stone passage with similar high accuracy as the mean of three readers' manual linear measurements. Manual size estimation of upper stones showed large inter-reader variations for spontaneous passage prediction. KEY POINTS: • An automated 3D technique predicts spontaneous stone passage with high accuracy. • Linear, areal and volumetric measurements performed similarly in predicting stone passage. • Reader variability has a large impact on the predicted prognosis for stone passage.


Asunto(s)
Imagenología Tridimensional/métodos , Cálculos Ureterales/diagnóstico por imagen , Cálculos Ureterales/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Probabilidad , Pronóstico , Curva ROC , Remisión Espontánea , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...