Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
JACC Cardiovasc Interv ; 16(14): 1763-1773, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37354158

RESUMEN

BACKGROUND: Segmental postpercutaneous coronary intervention (PCI) pressure gradients may detect residual disease and potential targets for optimization. However, universal definitions of relevant segmental gradients are lacking. OBJECTIVES: This study sought to evaluate the diagnostic performance of post-PCI fractional flow reserve (FFR), distal coronary pressure-to-aortic pressure ratio (Pd/Pa), and diastolic pressure ratio (dPR) gradients to detect residual focal lesions and stent underexpansion as observed by intravascular ultrasound (IVUS). METHODS: Patients from the IVUS-guided optimization arm of the FFR REACT (FFR-guided PCI Optimization Directed by High-Definition IVUS Versus Standard of Care) trial with complete IVUS and FFR pullback data were included. Patients with angiographically successful PCI and post-PCI FFR <0.90 underwent FFR, Pd/Pa, and IVUS pullbacks. dPR was calculated offline using dedicated software. Segmental pressure gradients (distal, in stent, and proximal) in segments ≥5 mm were evaluated against IVUS-detected residual disease (distal or proximal focal lesions and stent underexpansion). RESULTS: A total of 139 vessels were included (mean post-PCI FFR: 0.83 ± 0.05, range 0.56-0.89). Focal distal and proximal lesions were detected by IVUS in 23 (17.4%) of 132 and 14 (12.6%) of 111 vessels, respectively, whereas stent underexpansion was present in 86 (61.9%) vessels. Diagnostic ability of segmental FFR gradients to predict IVUS-detected distal and proximal lesions was moderate-to-good (area under the curve [AUC]: 0.69 and 0.84, respectively) and poor to moderate for segmental Pd/Pa and dPR gradients (AUC ranging from 0.58 to 0.69). In-stent gradients had no discriminative ability to detect stent underexpansion (FFR AUC: 0.52; Pd/Pa AUC: 0.54; dPR AUC: 0.55). CONCLUSIONS: In patients with post-PCI FFR <0.90, segmental post-PCI pressure gradients have moderate discriminative ability to identify IVUS-detected focal lesions but no discriminative ability to identify IVUS-detected stent underexpansion.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Angiografía Coronaria , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Ultrasonografía Intervencional , Stents , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Valor Predictivo de las Pruebas
2.
Catheter Cardiovasc Interv ; 102(2): 191-199, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37232425

RESUMEN

BACKGROUND: Dedicated prospective studies investigating high-definition intravascular ultrasound (HD-IVUS)-guided primary percutaneous coronary intervention (PCI) are lacking. The aim of this study was to qualify and quantify culprit lesion plaque characteristics and thrombus using HD-IVUS in patients presenting with ST-segment elevation myocardial infarction (STEMI). METHODS: The SPECTRUM study is a prospective, single-center, observational cohort study investigating the impact of HD-IVUS-guided primary PCI in 200 STEMI patients (NCT05007535). The first 100 study patients with a de novo culprit lesion and a per-protocol mandated preintervention pullback directly after vessel wiring were subject to a predefined imaging analysis. Culprit lesion plaque characteristics and different thrombus types were assessed. An IVUS-derived thrombus score, including a 1-point adjudication for a long total thrombus length, long occlusive thrombus length, and large maximum thrombus angle, was developed to differentiate between low (0-1 points) and high (2-3 points) thrombus burden. Optimal cut-off values were obtained using receiver operating characteristic curves. RESULTS: The mean age was 63.5 (±12.1) years and 69 (69.0%) patients were male. The median culprit lesion length was 33.5 (22.8-38.9) mm. Plaque rupture and convex calcium were appreciated in 48 (48.0%) and 10 (10.0%) patients, respectively. Thrombus was observed in 91 (91.0%) patients (acute thrombus 3.3%; subacute thrombus 100.0%; organized thrombus 22.0%). High IVUS-derived thrombus burden was present in 37/91 (40.7%) patients and was associated with higher rates of impaired final thrombolysis in myocardial infarction flow (grade 0-2) (27.0% vs. 1.9%, p < 0.001). CONCLUSIONS: HD-IVUS in patients presenting with STEMI allows detailed culprit lesion plaque characterization and thrombus grading that may guide tailored PCI.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Placa Aterosclerótica , Infarto del Miocardio con Elevación del ST , Trombosis , Humanos , Masculino , Persona de Mediana Edad , Femenino , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Estudios Prospectivos , Intervención Coronaria Percutánea/efectos adversos , Angiografía Coronaria , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos , Infarto del Miocardio/patología
3.
Catheter Cardiovasc Interv ; 102(1): 25-35, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37210611

RESUMEN

BACKGROUND: Severe coronary artery calcification is associated with stent underexpansion and subsequent stent failure. AIMS: We aimed to identify optical coherence tomography (OCT)-derived predictors of absolute (minimal stent area [MSA]) and relative stent expansion in calcified lesions. METHODS: This retrospective cohort study included patients who underwent percutaneous coronary intervention (PCI) with OCT assessment before and after stent implantation between May 2008 and April 2022. Pre-PCI OCT was used to assess calcium burden and post-PCI OCT was used to assess absolute and relative stent expansion. RESULTS: A total of 361 lesions in 336 patients were analyzed. Target lesion calcification (defined as OCT-detected maximum calcium angle ≥ 30°) was present in 242 (67.0%) lesions. Following PCI, median MSA was 5.37 mm2 in calcified lesions and 6.24 mm2 in noncalcified lesions (p < 0.001). Median stent expansion was 78% in calcified lesions and 83% in noncalcified lesions (p = 0.325). In the subset of calcified lesions, average stent diameter, preprocedural minimal lumen area, and total calcium length were independent predictors of MSA in multivariable analysis (mean difference 2.69 mm2 /mm2 , 0.52 mm2 /mm, and -0.28 mm2 /5 mm, respectively, all p < 0.001). Total stent length was the only independent predictor of relative stent expansion (mean difference -0.465% per mm, p < 0.001). Calcium angle, thickness, and the presence of nodular calcification were not significantly associated with MSA or stent expansion in multivariable analyses. CONCLUSION: Calcium length appeared to be the most important OCT-derived predictor of MSA, whereas stent expansion was mainly determined by total stent length.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Calcificación Vascular , Humanos , Intervención Coronaria Percutánea/efectos adversos , Tomografía de Coherencia Óptica/métodos , Estudios Retrospectivos , Calcio , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Calcificación Vascular/patología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Valor Predictivo de las Pruebas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/patología , Stents , Angiografía Coronaria/métodos
4.
Neth Heart J ; 31(5): 196-201, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36507948

RESUMEN

BACKGROUND: In January 2021, the Diamondback 360 orbital atherectomy (OA) system received CE mark approval and became available in Europe. The first procedure in Europe was performed at the Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands. AIMS: To report the procedural safety and efficacy of the initial experience with OA in a tertiary care institution in the Netherlands. METHODS: Patients with de novo severely calcified coronary artery disease who were treated with intended invasive imaging-guided OA were included in a prospective single-centre registry. Device success, defined as less than 50% stenosis after OA, and procedural success, defined as successful stent implantation with less than 50% residual stenosis, were evaluated. Calcium debulking effects were assessed by invasive imaging. Safety was assessed up to 30 days after the index procedure. RESULTS: Between February 2021 and June 2021, 29 patients with a total of 39 coronary arteries underwent OA. Target lesions were heavily calcified with a mean length of 32 mm and a calcium arc of 320 degrees. Invasive imaging was applied in all but one patient and 36 vessels. Superficial sanding was observed in almost all vessels (90%) and fracturing of deeper medial calcium in more than half of the vessels (63%), with a device success of 66% and procedural success of 94%. The mean stent symmetry index was 0.84, indicating good circular stent expansion. No primary safety events occurred during 30 days of follow-up. CONCLUSION: Our initial experience with OA for heavily calcified coronary lesions demonstrated favourable debulking effects and plaque modification, with high procedural success and clinical safety.

5.
J Invasive Cardiol ; 34(11): E811-E819, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36318461

RESUMEN

OBJECTIVE: Thinner stent struts might lead to a higher risk of recoil and subsequently a smaller minimal stent area (MSA), which is known to be the strongest predictor of stent failure. We compared procedural performance between an ultrathin-strut biodegradable-polymer sirolimus-eluting stent (BP-SES) and a durable-polymer zotarolimus-eluting stent (DP-ZES) using intracoronary imaging. METHODS: A consecutive cohort of patients underwent percutaneous coronary intervention (PCI) with either BP-SES or DP-ZES in a pseudorandomized fashion between July 2018 and October 2019. In the present subanalysis, we included cases in which post-PCI imaging with intravascular ultrasound (IVUS) or optical coherence tomography (OCT) was performed. The primary endpoint of the study was MSA. Secondary endpoints included percentage stent expansion and presence of residual edge disease, malapposition, tissue protrusion, submedial edge dissections, or edge hematoma. RESULTS: A total of 141 treated lesions (78 BP-SES and 63 DP-ZES) in 127 patients were analyzed. Median age was 69.3 years (interquartile range [IQR], 57.3-75.6) and 74.0% of patients were male. All baseline and procedural characteristics were comparable between both groups. Median MSA was 5.80 mm² (IQR, 4.40-7.24) for BP-SES and 6.35 mm² (IQR, 4.76-8.31) for DP-ZES (P=.15). No significant differences in stent expansion, residual edge disease and presence of malapposition, tissue protrusion, submedial edge dissections, or edge hematomas were found. Stent diameter and stent length were found to be independent predictors of MSA. CONCLUSIONS: No significant differences in MSA were found between lesions treated with BP-SES vs DP-ZES. BP-SES and DP-ZES were comparable in terms of procedural performance.


Asunto(s)
Fármacos Cardiovasculares , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Masculino , Anciano , Femenino , Everolimus , Implantes Absorbibles , Polímeros , Enfermedad de la Arteria Coronaria/terapia , Diseño de Prótesis , Resultado del Tratamiento
6.
JACC Cardiovasc Interv ; 15(16): 1595-1607, 2022 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-35981832

RESUMEN

BACKGROUND: Post-percutaneous coronary intervention (PCI) fractional flow reserve (FFR) <0.90 is common and has been related to impaired patient outcome. OBJECTIVES: The authors sought to evaluate if PCI optimization directed by intravascular ultrasound (IVUS) in patients with post-PCI FFR <0.90 could improve 1-year target vessel failure (TVF) rates. METHODS: In this single-center, randomized, double-blind trial, patients with a post-PCI FFR <0.90 at the time of angiographically successful PCI were randomized to IVUS-guided optimization or the standard of care (control arm). The primary endpoint was TVF (a composite of cardiac death, spontaneous target vessel myocardial infarction, and clinically driven target vessel revascularization) at 1 year. RESULTS: A total of 291 patients with post-PCI FFR <0.90 were randomized (IVUS-guided optimization arm: n = 145/152 vessels, control arm: n = 146/157 vessels). The mean post-PCI FFR was 0.84 ± 0.05. A total of 104 (68.4%) vessels in the IVUS-guided optimization arm underwent additional optimization including additional stenting (34.9%) or postdilatation only (33.6%), resulting in a mean increase in post-PCI FFR in these vessels from 0.82 ± 0.06 to 0.85 ± 0.05 (P < 0.001) and a post-PCI FFR ≥0.90 in 20% of the vessels. The 1-year TVF rate was comparable between the 2 study arms (IVUS-guided optimization arm: 4.2%, control arm: 4.8%; P = 0.79). There was a trend toward a lower incidence of clinically driven target vessel revascularization in the IVUS-guided optimization arm (0.7% vs. 4.2%, P = 0.06). CONCLUSIONS: IVUS-guided post-PCI FFR optimization significantly improved post-PCI FFR. Because of lower-than-expected event rates, post-PCI FFR optimization did not significantly lower TVF at the 1-year follow-up.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Nivel de Atención , Resultado del Tratamiento
7.
J Invasive Cardiol ; 34(9): E686-E688, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35738562

RESUMEN

BACKGROUND: Vessel fractional flow reserve (vFFR) has a high diagnostic accuracy in assessing functional lesion significance compared with FFR. Nonhyperemic pressure ratios (NHPRs) were noninferior to FFR to guide revascularization of intermediate lesions. Therefore, the diagnostic performance of vFFR compared with NHPR warrants interest. AIM: To evaluate the diagnostic performance of vFFR with a generic diastolic pressure ratio (dPR) as a reference. METHODS: The study population was derived from the FAST EXTEND and FAST II studies. Between January 2016 and September 2020, a total of 475 patients were enrolled. RESULTS: Median dPR was 0.92 (interquartile range [IQR], 0.87-0.95), median vFFR was 0.86 (IQR, 0.80-0.90). The sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of vFFR ≤0.80 for dPR ≤0.89 were 66%, 92%, 79%, 85%, and 84%, respectively. Vessel FFR showed a good agreement with dPR (r=0.68), consistent among specific clinical lesion subsets and a high diagnostic accuracy for dPR ≤0.89 (area under the curve=0.89). Discordance between vFFR and dPR was observed in 78/492 cases (15.6%) and logistic regression analysis did not reveal any clinical, angiographic, or hemodynamic variables associated with vFFR and dPR discordance. CONCLUSION: Vessel FFR shows a good agreement with dPR and a high diagnostic accuracy for dPR ≤0.89.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Presión Sanguínea , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Diástole , Humanos , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
8.
Int J Cardiol ; 359: 14-19, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-35421516

RESUMEN

BACKGROUND: Vessel Fractional Flow Reserve (vFFR) as assessed by three-dimensional quantitative coronary angiography has high correlation with pressure wire-based fractional flow reserve in both a pre- and post-PCI setting. The present study aims to assess the prognostic value of post-PCI vFFR on the incidence of target vessel failure (TVF), a composite endpoint of cardiac death, target vessel myocardial infarction and target vessel revascularization (TVR) at 5-year follow up. METHODS: Post-PCI vFFR was calculated after routine PCI in a total of 748 patients (832 vessels) with available orthogonal angiographic projections of the stented segment. RESULTS: Median age was 65 (IQR 55-74) years, 18.2% were diabetic, and 29.1% presented with stable angina. Median post-PCI vFFR was 0.91 (IQR 0.86-0.95). Vessels were categorized into tertiles based on post-PCI vFFR: low (vFFR <0.88), middle (vFFR 0.88-0.93), and upper (vFFR ≥0.94). Vessels in the lower and middle tertile were more often LADs and had smaller stent diameters (p<0.001). Vessels in the lower and middle tertile had a higher risk of TVF as compared to vessels in the upper tertile (24.6% and 21.5% vs. 17.1%; adjusted HR 1.84 (95%CI 1.15-2.95), p = 0.011, and 1.58 (95%CI 1.02-2.45), p = 0.040) at 5-years follow-up. Additionally, vessels in the lower tertile had higher rates of TVR as compared to vessels in the higher tertile (12.6% vs. 6.5%, adjusted HR 1.93 (95%CI 1.06-3.53), p = 0.033). CONCLUSION: Lower post-PCI vFFR values are associated with a significantly increased risk of TVF and TVR at 5-years follow-up.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Anciano , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Evaluación de Resultado en la Atención de Salud , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Pronóstico , Resultado del Tratamiento
10.
J Cardiovasc Transl Res ; 14(5): 992-1000, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33624259

RESUMEN

BACKGROUND: Coronary calcification has been linked to cardiovascular events. We developed and validated an algorithm to automatically quantify coronary calcifications on intravascular ultrasound (IVUS). We aimed to assess the prognostic value of an IVUS-calcium score (ICS) on patient-oriented composite endpoint (POCE). METHODS: We included patients that underwent coronary angiography plus pre-procedural IVUS imaging. The ICS was calculated per patient. The primary endpoint was a composite of all-cause mortality, stroke, myocardial infarction, and revascularization (POCE). RESULTS: In a cohort of 408 patients, median ICS was 85. Both an ICS ≥ 85 and a 100 unit increase in ICS increased the risk of POCE at 6-year follow-up (adjusted hazard ratio (aHR) 1.51, 95%CI 1.05-2.17, p value = 0.026, and aHR 1.21, 95%CI 1.04-1.41, p value = 0.014, respectively). CONCLUSIONS: The ICS, calculated by a validated automated algorithm derived from routine IVUS pullbacks, was strongly associated with the long-term risk of POCE.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Ultrasonografía Intervencional , Calcificación Vascular/diagnóstico por imagen , Anciano , Automatización , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Progresión de la Enfermedad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Revascularización Miocárdica , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Calcificación Vascular/mortalidad , Calcificación Vascular/terapia
12.
Ultrasound Med Biol ; 46(10): 2801-2809, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32636052

RESUMEN

Coronary calcification represents a challenge in the treatment of coronary artery disease by stent placement. It negatively affects stent expansion and has been related to future adverse cardiac events. Intravascular ultrasound (IVUS) is known for its high sensitivity in detecting coronary calcification. At present, automated quantification of calcium as detected by IVUS is not available. For this reason, we developed and validated an optimized framework for accurate automated detection and quantification of calcified plaque in coronary atherosclerosis as seen by IVUS. Calcified lesions were detected by training a supported vector classifier per IVUS A-line on manually annotated IVUS images, followed by post-processing using regional information. We applied our framework to 35 IVUS pullbacks from each of the three commonly used IVUS systems. Cross-validation accuracy for each system was >0.9, and the testing accuracy was 0.87, 0.89 and 0.89 for the three systems. Using the detection result, we propose an IVUS calcium score, based on the fraction of calcium-positive A-lines in a pullback segment, to quantify the extent of calcified plaque. The high accuracy of the proposed classifier suggests that it may provide a robust and accurate tool to assess the presence and amount of coronary calcification and, thus, may play a role in image-guided coronary interventions.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico por imagen , Ultrasonografía Intervencional , Calcificación Vascular/diagnóstico por imagen , Automatización , Humanos
13.
Int J Cardiovasc Imaging ; 36(6): 1021-1029, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32112229

RESUMEN

To quantify the impact of cardiac motion on stent length measurements with Optical Coherence Tomography (OCT) and to demonstrate in vivo OCT imaging of implanted stents, without motion artefacts. The study consists of: clinical data evaluation, simulations and in vivo tests. A comparison between OCT-measured and nominal stent lengths in 101 clinically acquired pullbacks was carried out, followed by a simulation of the effect of cardiac motion on stent length measurements, experimentally and computationally. Both a commercial system and a custom OCT, capable of completing a pullback between two consecutive ventricular contractions, were employed. A 13 mm long stent was implanted in the left anterior descending branch of two atherosclerotic swine and imaged with both OCT systems. The analysis of the clinical OCT images yielded an average difference of 1.1 ± 1.6 mm, with a maximum difference of 7.8 mm and the simulations replicated the statistics observed in clinical data. Imaging with the custom OCT, yielded an RMS error of 0.14 mm at 60 BPM with the start of the acquisition synchronized to the cardiac cycle. In vivo imaging with conventional OCT yielded a deviation of 1.2 mm, relative to the length measured on ex-vivo micro-CT, while the length measured in the pullback acquired by the custom OCT differed by 0.20 mm. We demonstrated motion artefact-free OCT-imaging of implanted stents, using ECG triggering and a rapid pullback.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Electrocardiografía , Frecuencia Cardíaca , Intervención Coronaria Percutánea/instrumentación , Tomografía de Coherencia Óptica , Animales , Artefactos , Enfermedad de la Arteria Coronaria/fisiopatología , Modelos Animales de Enfermedad , Humanos , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sus scrofa
14.
EuroIntervention ; 16(7): 591-599, 2020 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-31085504

RESUMEN

AIMS: The aim of this study was to validate novel software to calculate vessel fractional flow reserve (vFFR) based on 3D-QCA and to assess inter-observer variability in patients who underwent routine preprocedural FFR assessment for intermediate coronary artery stenosis. METHODS AND RESULTS: In vitro validation was performed in an experimental model. Clinical validation was performed in an observational, retrospective, single-centre cohort study. A total of 100 patients presenting with stable angina or non-ST-segment elevation myocardial infarction and an indication to perform FFR between January 2016 and October 2016 were included. vFFR was calculated based on the aortic root pressure along with two angiographic projections and validated against pressure wire-derived FFR. Mean FFR and vFFR were 0.82±0.08 and 0.84±0.07, respectively. A good linear correlation was found between FFR and vFFR (r=0.89; p<0.001). Assessment of vFFR had a low inter-observer variability (r=0.95; p<0.001). The diagnostic accuracy of vFFR in identifying lesions with an FFR ≤0.80 was higher as compared with 3D-QCA: AUC 0.93 (95% CI: 0.88-0.97) vs 0.66 (95% CI: 0.55-0.77), respectively. CONCLUSIONS: The 3D-QCA-derived vFFR has a high linear correlation to invasively measured FFR, a high diagnostic accuracy to detect FFR ≤0.80 and a low inter-observer variability.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Estudios de Cohortes , Angiografía Coronaria , Humanos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Programas Informáticos
15.
Arterioscler Thromb Vasc Biol ; 39(11): 2338-2352, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31554418

RESUMEN

OBJECTIVE: In an adult porcine model of familial hypercholesterolemia (FH), coronary plaque development was characterized. To elucidate the underlying mechanisms of the observed inter-individual variation in disease severity, detailed lipoprotein profiles were determined. Approach and Results: FH pigs (3 years old, homozygous LDLR R84C mutation) received an atherogenic diet for 12 months. Coronary atherosclerosis development was monitored using serial invasive imaging and histology. A pronounced difference was observed between mildly diseased pigs which exclusively developed early lesions (maximal plaque burden, 25% [23%-34%]; n=5) and advanced-diseased pigs (n=5) which developed human-like, lumen intruding plaques (maximal plaque burden, 69% [57%-77%]) with large necrotic cores, intraplaque hemorrhage, and calcifications. Advanced-diseased pigs and mildly diseased pigs displayed no differences in conventional risk factors. Additional plasma lipoprotein profiling by size-exclusion chromatography revealed 2 different LDL (low-density lipoprotein) subtypes: regular and larger LDL. Cholesterol, sphingosine-1-phosphate, ceramide, and sphingomyelin levels were determined in these LDL-subfractions using standard laboratory techniques and high-pressure liquid chromatography mass-spectrometry analyses, respectively. At 3 months of diet, regular LDL of advanced-diseased pigs contained relatively more cholesterol (LDL-C; regular/larger LDL-C ratio 1.7 [1.3-1.9] versus 0.8 [0.6-0.9]; P=0.008) than mildly diseased pigs, while larger LDL contained more sphingosine-1-phosphate, ceramides, and sphingomyelins. Larger and regular LDL was also found in plasma of 3 patients with homozygous FH with varying LDL-C ratios. CONCLUSIONS: In our adult FH pig model, inter-individual differences in atherosclerotic disease severity were directly related to the distribution of cholesterol and sphingolipids over a distinct LDL profile with regular and larger LDL shortly after the diet start. A similar LDL profile was detected in patients with homozygous FH.


Asunto(s)
LDL-Colesterol/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/patología , Hiperlipoproteinemia Tipo II/sangre , Hiperlipoproteinemia Tipo II/patología , Placa Aterosclerótica/sangre , Placa Aterosclerótica/patología , Animales , LDL-Colesterol/clasificación , Dieta Aterogénica , Modelos Animales de Enfermedad , Femenino , Humanos , Hiperlipoproteinemia Tipo II/diagnóstico por imagen , Masculino , Placa Aterosclerótica/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Esfingolípidos/sangre , Porcinos
17.
EBioMedicine ; 36: 63-72, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30131305

RESUMEN

Background: Certain immunoglobulins (Ig) are proposed to have protective functions in atherosclerosis. Objectives: We tested whether serum levels of IgG and IgM autoantibodies against malondialdehyde low density lipoprotein (MDA-LDL) are associated with clinical coronary heart disease (CHD) and unfavorable plaque characteristics. Methods: NORDIL was a prospective study investigating adverse cardiovascular outcomes in hypertensive patients. IBIS-3 analyzed lesions in a non-culprit coronary artery with <50% stenosis using radiofrequency intravascular ultrasound (RF-IVUS) and near-infrared spectroscopy (NIRS). Imaging was repeated after a median of 386?days on rosuvastatin. Associations of antibodies with incident CHD and imaging parameters were assessed in the two sub-studies respectively. Findings: From 10,881 NORDIL patients, 87 had serum sampled at baseline and developed CHD over 4.5 years, matched to 227 controls. Higher titers of IgM anti-MDA-LDL had a protective effect on adverse outcomes, with odds ratio 0.29 (0.11, 0.76; p=0.012; p=0.016 for trend). Therefore, the effect was explored at the lesional level in IBIS-3. 143 patients had blood samples and RF-IVUS measurements available, and NIRS was performed in 90 of these. At baseline, IgM anti-MDA-LDL levels had a strong independent inverse relationship with lesional necrotic core volume (p=0.027) and percentage of plaque occupied by necrotic core (p=0.011), as well as lipid core burden index (p=0.024) in the worst 4 mm segment. Interpretation: Our study supports the hypothesis that lower circulating levels of IgM anti-MDA-LDL are associated with clinical CHD development, and for the first time relates these findings to atherosclerotic plaque characteristics that are linked to vulnerability.


Asunto(s)
Enfermedad de la Arteria Coronaria/sangre , Inmunoglobulina M/sangre , Lipoproteínas LDL/inmunología , Malondialdehído/análogos & derivados , Necrosis/sangre , Anciano , Aterosclerosis/sangre , Biomarcadores/sangre , Femenino , Humanos , Masculino , Malondialdehído/inmunología , Persona de Mediana Edad , Estudios Prospectivos
18.
Eur Heart J Cardiovasc Imaging ; 18(4): 467-474, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-26992420

RESUMEN

AIMS: Previous studies have reported the safety and feasibility of both time-domain optical coherence tomography (TD-OCT) and Fourier-domain OCT (FD-OCT) in highly selected patients and clinical settings. However, the generalizability of these data is limited, and data in unselected patient populations reflecting a routine cathlab practice are lacking. We compared safety of intracoronary FD-OCT imaging to intravascular ultrasound (IVUS) imaging in a large real-world series of consecutive patients who underwent invasive imaging during coronary catheterization in our centre. METHODS AND RESULTS: This is a prospective, single-centre registry of patients scheduled for coronary angiography or intervention undergoing intracoronary imaging with FD-OCT or IVUS between April 2008 and December 2013. Intra-procedural and major in-hospital adverse events that could be possibly related to invasive imaging were registered routinely by the operator as part of our clinical report and prospectively recorded in our database. These events were retrospectively individually adjudicated by an independent safety committee. Between April 2008 and December 2013, 13 418 diagnostic or interventional coronary catheterization procedures were performed. Of these, 1142 procedures used OCT and 2476 procedures used IVUS. Invasive imaging-related complications were rare, did not differ between the two imaging methods (OCT: n = 7, 0.6%; IVUS: n = 12, 0.5%; P = 0.6), and were self-limiting after retrieval of the imaging catheter or easily treatable in the catheterization laboratory. No major adverse events, prolongation of hospital stay, or permanent patient harm was observed. CONCLUSION: FD-OCT is safe in an unselected and heterogeneous group of patients with varying clinical settings.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Seguridad del Paciente , Sistema de Registros , Tomografía de Coherencia Óptica/métodos , Ultrasonografía Intervencional/métodos , Anciano , Análisis de Varianza , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios de Cohortes , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Selección de Paciente , Intervención Coronaria Percutánea/métodos , Valor Predictivo de las Pruebas , Cuidados Preoperatorios/métodos , Estudios Prospectivos , Medición de Riesgo , Administración de la Seguridad , Tomografía de Coherencia Óptica/efectos adversos , Ultrasonografía Intervencional/efectos adversos
19.
Catheter Cardiovasc Interv ; 90(1): 58-69, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27896897

RESUMEN

BACKGROUND: Limited data are currently available on the performance of everolimus eluting bioresorbable vascular scaffold (BVS) for treatment of complex coronary lesions representative of daily practice. METHODS: This is a prospective, mono-center, single-arm study, reporting data after BVS implantation in patients presenting with stable, unstable angina, or non-ST segment elevation myocardial infarction caused by de novo stenotic lesions in native coronary arteries. No restrictions were applied to lesion complexity. Procedural results and 12-month clinical outcomes were reported. RESULTS: A total of 180 patients have been evaluated in the present study, with 249 treated coronary lesions. Device Success per lesion was 99.2%. A total of 119 calcified lesions were treated. Comparable results were observed among severe, moderate and noncalcified lesions in term of %diameter stenosis (%DS) (20.3 ± 10.5%, 17.8 ± 7.7%, 16.8 ± 8.6%; P = 0.112) and acute gain (1.36 ± 0.41 mm, 1.48 ± 0.44 mm, 1.56 ± 0.54 mm; P = 0.109). In bifurcations (54 lesions), side-branch ballooning after main vessel treatment was often performed (33.3%) with low rate of side-branch impairment (9.3%). A total of 29 cases with coronary total occlusions were treated. After BVS implantation %DS was not different from other lesion types (17.2 ± 9.4%, vs. 17.7 ± 8.6%; P = 0.780). At one year, all-cause mortality was reported in three cases. The rate of target lesion revascularization and target vessel revascularization was 3.3%. The rate of definite scaffold thrombosis was 2.6%. CONCLUSIONS: The implantation of the everolimus eluting bioresorbable vascular scaffold in an expanded range of coronary lesion types and clinical presentations was observed to be feasible with promising angiographic results and mid-term clinical outcomes. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Implantes Absorbibles , Angina Estable/terapia , Angina Inestable/terapia , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Estenosis Coronaria/terapia , Everolimus/administración & dosificación , Infarto del Miocardio sin Elevación del ST/terapia , Calcificación Vascular/terapia , Anciano , Angina Estable/diagnóstico por imagen , Angina Estable/mortalidad , Angina Inestable/diagnóstico por imagen , Angina Inestable/mortalidad , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Toma de Decisiones Clínicas , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Everolimus/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/mortalidad , Selección de Paciente , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Intervencional , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/mortalidad
20.
EuroIntervention ; 12(6): 734-9, 2016 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-27542785

RESUMEN

AIMS: Statins are highly effective in reducing major adverse clinical events, but the direct effects on coronary plaque composition remain debatable. Our aim was to mechanistically evaluate the treatment effect of high-intensity statin therapy on compositional coronary plaque changes. METHODS AND RESULTS: The third Integrated Biomarker and Imaging Study (IBIS-3) was a prospective, investigator-initiated, single-centre study. Serial radiofrequency intravascular ultrasound (RF-IVUS) measurements of a predefined non-stenotic segment in a non-culprit coronary artery were performed to evaluate the effect of rosuvastatin (intended dose: 40 mg daily) on necrotic core (NC) volume in patients with stable angina or acute coronary syndrome. Changes in lipid core burden index (LCBI) were evaluated through serial near-infrared spectroscopy (NIRS) imaging in a subset. Serial RF-IVUS (and NIRS) data of a median segment of 41 mm (interquartile range: 32 to 49 mm) were complete in 164 (103) patients. Follow-up measurements were performed at six and 12 months in 30 (26) and 134 (77) patients, respectively. Mean levels of low-density lipoprotein cholesterol decreased by 30%, from 2.49 mmol/l to 1.73 mmol/l at the end of follow-up. High-dose rosuvastatin therapy resulted in a non-significant change of -1.4 mm3 (95% CI: -3.0, 0.1) in NC volume during follow-up (p=0.074). The change in NC percentage of total plaque volume was -1.4% (95% CI: -2.4 to -0.4; p=0.006). A neutral effect was also observed on LCBI. Indications of significant regression of NC volume and LCBI in the highest baseline quartiles were observed, which should cautiously be regarded as hypothesis-generating. CONCLUSIONS: High-intensity rosuvastatin therapy during one year resulted in a neutral effect on NC and LCBI within non-stenotic, non-culprit coronary segments with a relatively low atheroma burden. This study has been registered in The Netherlands Trial Register (NTR) nr. 2872.


Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Vasos Coronarios/efectos de los fármacos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Rosuvastatina Cálcica/uso terapéutico , Anciano , Biomarcadores/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/farmacología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Rosuvastatina Cálcica/farmacología , Espectroscopía Infrarroja Corta , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...