Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Diabetes Sci Technol ; : 19322968241234072, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38439656

RESUMEN

BACKGROUND: Control-IQ technology version 1.5 allows for a wider range of weight and total daily insulin (TDI) entry, in addition to other changes to enhance performance for users with high basal rates. This study evaluated the safety and performance of the updated Control-IQ system for users with basal rates >3 units/h and high TDI in a multicenter, single arm, prospective study. METHODS: Adults with type 1 diabetes (T1D) using continuous subcutaneous insulin infusion (CSII) and at least one basal rate over 3 units/h (N = 34, mean age = 39.9 years, 41.2% female, diabetes duration = 21.8 years) used the t:slim X2 insulin pump with Control-IQ technology version 1.5 for 13 weeks. Primary outcome was safety events (severe hypoglycemia and diabetic ketoacidosis (DKA)). Central laboratory hemoglobin A1c (HbA1c) was measured at system initiation and 13 weeks. Participants continued using glucagon-like peptide-1 (GLP-1) receptor agonists, sodium-glucose transport protein 2 (SGLT-2) inhibitors, or other medications for glycemic control and/or weight loss if on a stable dose. RESULTS: All 34 participants completed the study. Fifteen participants used a basal rate >3 units/h for all 24 hours of the day. Nine participants used >300 units TDI on at least one day during the study. There were no severe hypoglycemia or DKA events. Time in range 70-180 mg/dL was 64.8% over the 13 weeks, with 1.0% time <70 mg/dL. Hemoglobin A1c decreased from 7.69% at baseline to 6.87% at 13 weeks (-0.82%, P < .001). CONCLUSIONS: Control-IQ technology version 1.5, with wider range of weight and TDI input and enhancements for users with high insulin requirements, was safe in individuals with T1D in this study.

2.
PLoS One ; 18(12): e0293268, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38096190

RESUMEN

Studies of new therapies to preserve insulin secretion in early type 1 diabetes require several years to recruit eligible subjects and to see a treatment effect; thus, there is interest in alternative study designs to speed this process. Most people with longstanding type 1 diabetes no longer secrete insulin. However, studies from pancreata of those with longstanding T1D show that beta cells staining for insulin can persist for decades after diagnosis, and this is paralleled in work showing proinsulin secretion in individuals with longstanding disease; collectively this suggests that there is a reserve of alive but "sleeping" beta cells. Here, we designed a novel clinical trial platform to test whether a short course of therapy with an agent known to have effects in type 1 diabetes with residual endogenous insulin could transiently induce insulin secretion in those who no longer produce insulin. A therapy that transiently "wakes up" sleeping beta cells might be tested next in a fully powered trial in those with endogenous insulin secretion. In this three-arm non-randomized pilot study, we tested three therapies known to impact disease: two beta-cell supportive agents, liraglutide and verapamil, and an immunomodulatory agent, golimumab. The golimumab treated arm was not fully enrolled due to uncertainties about immunotherapy during the COVID-19 pandemic. Participants had mixed-meal tolerance test (MMTT)-stimulated C-peptide below the quantitation limit (<0.02 ng/mL) at enrollment and received 8 to 12 weeks of therapy. At the completion of therapy, none of the individuals achieved the primary outcome of MMTT-stimulated C-peptide ≥ 0.02 ng/mL. An exploratory outcome of the verapamil arm was MRI-assessed pancreas size, diffusion, and longitudinal relaxation time, which showed repeatability of these measures but no treatment effect. The liraglutide and golimumab arms were registered on clinicaltrials.gov under accession number NCT03632759 and the verapamil arm under accession number NCT05847413. Trail registration: Protocols are registered in ClinicalTrials.gov under accession numbers NCT03632759 and NCT05847413.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Péptido C , Liraglutida , Proyectos Piloto , Pandemias , Insulina/uso terapéutico , Verapamilo
3.
Diabetes Technol Ther ; 25(11): 755-764, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37782145

RESUMEN

Background: During MiniMed™ advanced hybrid closed-loop (AHCL) use by adolescents and adults in the pivotal trial, glycated hemoglobin (A1C) was significantly reduced, time spent in range (TIR) was significantly increased, and there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA). The present study investigated the same primary safety and effectiveness endpoints during AHCL use by a younger cohort with type 1 diabetes (T1D). Methods: An intention-to-treat population (N = 160, aged 7-17 years) with T1D was enrolled in a single-arm study at 13 investigational centers. There was a run-in period (∼25 days) using HCL or sensor-augmented pump with/without predictive low-glucose management, followed by a 3-month study period with AHCL activated at two glucose targets (GTs; 100 and 120 mg/dL) for ∼45 days each. The mean ± standard deviation values of A1C, TIR, mean sensor glucose (SG), coefficient of variation (CV) of SG, time at SG ranges, and insulin delivered between run-in and study were analyzed (Wilcoxon signed-rank test or t-test). Results: Compared with baseline, AHCL use was associated with reduced A1C from 7.9 ± 0.9% (N = 160) to 7.4 ± 0.7% (N = 136) (P < 0.001) and overall TIR increased from the run-in 59.4 ± 11.8% to 70.3 ± 6.5% by end of study (P < 0.001), without change in CV, time spent below range (TBR) <70 mg/dL, or TBR <54 mg/dL. Relative to longer active insulin time (AIT) settings (N = 52), an AIT of 2 h (N = 19) with the 100 mg/dL GT increased mean TIR to 73.4%, reduced TBR <70 mg/dL from 3.5% to 2.2%, and reduced time spent above range (TAR) >180 mg/dL from 28.7% to 24.4%. During AHCL use, there was no severe hypoglycemia or DKA. Conclusions: In children and adolescents with T1D, MiniMed AHCL system use was safe, A1C was lower, and TIR was increased. The lowest GT and shortest AIT were associated with the highest TIR and lowest TBR and TAR, all of which met consensus-recommended glycemic targets. ClinicalTrials.gov ID: NCT03959423.


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Hipoglucemia , Adolescente , Adulto , Niño , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Cetoacidosis Diabética/etiología , Glucosa , Hemoglobina Glucada , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemia/complicaciones , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Resultado del Tratamiento
4.
Diabetes Ther ; 14(4): 767-776, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36877403

RESUMEN

INTRODUCTION: We have evaluated the performance of the FreeStyle Libre® 3 continuous glucose monitoring system (FSL3) compared to (1) the venous plasma reference for participants aged ≥ 6 years and (2) the fingerstick capillary blood glucose (BG) reference for pediatric participants aged 4 and 5 years. The analytical performance of the third-generation factory-calibrated FSL3 CGM system was compared to the plasma venous blood glucose reference using the YSI 2300 STAT PLUS Glucose and Lactate Analyzer (the YSI reference) and the self-monitoring blood glucose (SMBG) reference for participants aged ≥ 6 years and participants aged 4 and 5 years, respectively. METHODS: A total of 108 participants aged ≥ 4 years with type 1 or type 2 diabetes from four sites in the USA were enrolled in the study. The data of 100 participants were ultimately evaluated. Adult participants (aged ≥ 18 years) participated in three in-clinic sessions, and pediatric participants (aged 4-17 years) participated in up to two in-clinic sessions, all stratified to provide data for days 1, 2, 3, 7, 8, 9, 12, 13 or 14 of sensor wear. Performance evaluation included accuracy measures, such as proportion of CGM values that fell within ± 20% or ± 20 mg/dL (1.1 mmol/L) of the reference glucose values, and difference measures, such as the mean absolute relative difference (MARD) between the CGM and reference values. RESULTS: Data from the 100 study participants were analyzed. The overall MARD was 7.8%, and 93.4% of the CGM values were within ± 20% or ± 20 mg/dL of the YSI reference for participants aged ≥ 6 years, with 6845 CGM-YSI matched pairs. The performance was stable over the 14-day wear period. For participants aged 4-5 years, MARD was 10.0%, and 88.9% of the CGM values were within 20%/20 mg/dL compared to a SMBG reference. No serious adverse events were reported. CONCLUSIONS: The FSL3 CGM system demonstrated accurate performance across the dynamic glycemic range during the 14-day sensor wear period.

5.
Diabetes Technol Ther ; 25(1): 1-12, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36472543

RESUMEN

Objective: To evaluate safety and effectiveness of MiniMed™ 670G hybrid closed loop (HCL) in comparison with continuous subcutaneous insulin infusion (CSII) therapy for 6 months in persons with type 1 diabetes (T1D). Methods: Adults (aged 18-80 years), adolescents, and children (aged 2-17 years) with T1D who were using CSII therapy were enrolled and randomized (1:1) to 6 months of HCL intervention (n = 151, mean age of 39.9 ± 19.8 years) or CSII without continuous glucose monitoring (n = 151, 35.7 ± 18.4 years). Primary effectiveness endpoints included change in A1C for Group 1 (baseline A1C >8.0%), from baseline to the end of study, and difference in the end of study percentage of time spent below 70 mg/dL (%TBR <70 mg/dL) for Group 2 (baseline A1C ≤8.0%), to show superiority of HCL intervention versus control. Secondary effectiveness endpoints were change in A1C and %TBR <70 mg/dL for Group 2 and Group 1, respectively, to show noninferiority of HCL intervention versus control. Primary safety endpoints were rates of severe hypoglycemia and diabetic ketoacidosis (DKA). Results: Change in A1C and difference in %TBR <70 mg/dL for the overall group were significantly improved, in favor of HCL intervention. In addition, a significant mean (95% confidence interval) change in A1C was observed for both Group 1 (-0.8% [-1.1% to -0.4%], P < 0.0001) and Group 2 (-0.3% [-0.5% to -0.1%], P < 0.0001), in favor of HCL intervention. The same was observed for difference in %TBR <70 mg/dL for Group 1 (-2.2% [-3.6% to -0.9%]) and Group 2 (-4.9% [-6.3% to -3.6%]) (P < 0.0001 for both). There was one DKA event during run-in and six severe hypoglycemic events: two during run-in and four during study (HCL: n = 0 and CSII: n = 4 [6.08 per 100 patient-years]). Conclusions: This RCT demonstrates that the MiniMed 670G HCL safely and significantly improved A1C and %TBR <70 mg/dL compared with CSII control in persons with T1D, irrespective of baseline A1C level.


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Adolescente , Adulto , Niño , Humanos , Persona de Mediana Edad , Adulto Joven , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Cetoacidosis Diabética/tratamiento farmacológico , Hemoglobina Glucada , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Preescolar , Anciano , Anciano de 80 o más Años
6.
Diabetes Technol Ther ; 24(11): 789-796, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35763337

RESUMEN

Background: The COVID-19 pandemic and the rapid expansion of telemedicine have increased the need for accurate and reliable capillary hemoglobin A1c (HbA1c) testing. Nevertheless, validation studies of commercially available products suitable for home use have been in short supply. Methods: Three commercial home-use capillary blood sample HbA1c tests (Home Access, CoreMedica, and A1cNow+) were evaluated in 219 participants with type 1 or type 2 diabetes (4-80 years years of age, HbA1c 5.1%-13.4% [32-123 mmol/mol]) at four clinical sites. Comparisons were made between HbA1c measurements from the commercial tests and paired venous samples for which HbA1c was measured at two central reference laboratories. The primary outcome was percentage of commercial HbA1c values within 5% of the corresponding reference values. Results: HbA1c values were within 5% (relative difference) of paired reference values for 82% of Home Access samples, 29% of CoreMedica samples, and 46% of A1cNow+ samples. Absolute differences were within 0.3% of the reference value for 75% of Home Access samples, 28% of CoreMedica samples, and 44% of A1cNow+ samples and exceeded 0.5% for 8%, 55%, and 37%, respectively. Conclusions: None of the commercial home-use HbA1c tests produced the National Glycohemoglobin Standardization Program goal of ≥90% measurements within 5% of a DCCT venous reference. However, the Home Access product performed substantially better than the CoreMedica or A1cNow+ products. Telemedicine is likely to persist as a mainstay of diabetes care well after the COVID-19 era. As such, accurate home-based HbA1c assessment represents an urgent need for the diabetes community.


Asunto(s)
COVID-19 , Diabetes Mellitus Tipo 2 , Humanos , Hemoglobina Glucada/análisis , Pandemias , Estándares de Referencia
7.
Pediatr Diabetes ; 23(3): 324-329, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35001477

RESUMEN

BACKGROUND: Highly variable insulin sensitivity, susceptibility to hypoglycemia and inability to effectively communicate hypoglycemic symptoms pose significant challenges for young children with type 1 diabetes (T1D). Herein, outcomes during clinical MiniMed™ 670G system use were evaluated in children aged 2-6 years with T1D. METHODS: Participants (N = 46, aged 4.6 ± 1.4 years) at seven investigational centers used the MiniMed™ 670G system in Manual Mode during a two-week run-in period followed by Auto Mode during a three-month study phase. Safety events, mean A1C, sensor glucose (SG), and percentage of time spent in (TIR, 70-180 mg/dl), below (TBR, <70 mg/dl) and above (TAR, >180 mg/dl) range were assessed for the run-in and study phase and compared using a paired t-test or Wilcoxon signed-rank test. RESULTS: From run-in to end of study (median 87.1% time in auto mode), mean A1C and SG changed from 8.0 ± 0.9% to 7.5 ± 0.6% (p < 0.001) and from 173 ± 24 to 161 ± 16 mg/dl (p < 0.001), respectively. Overall TIR increased from 55.7 ± 13.4% to 63.8 ± 9.4% (p < 0.001), while TBR and TAR decreased from 3.3 ± 2.5% to 3.2 ± 1.6% (p = 0.996) and 41.0 ± 14.7% to 33.0 ± 9.9% (p < 0.001), respectively. Overnight TBR remained unchanged and TAR was further improved 12:00 am-6:00 am. Throughout the study phase, there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA) and no serious adverse device-related events. CONCLUSIONS: At-home MiniMed™ 670G Auto Mode use by young children safely improved glycemic outcomes compared to two-week open-loop Manual Mode use. The improvements are similar to those observed in older children, adolescents and adults with T1D using the same system for the same duration of time.


Asunto(s)
Diabetes Mellitus Tipo 1 , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Preescolar , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos
8.
J Diabetes Sci Technol ; 16(1): 70-77, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32954812

RESUMEN

BACKGROUND: In this study, we evaluated the analytical performance of the second-generation factory-calibrated FreeStyle Libre Flash Glucose Monitoring (FreeStyle Libre 2) System compared to plasma venous blood glucose reference, Yellow Springs Instrument 2300 (YSI). METHODS: The study enrolled participants aged four and above with type 1 or type 2 diabetes at seven sites in the United States. Adult participants (18+ years) participated in three in-clinic sessions and pediatric participants (4-17 years) participated in up to two in-clinic sessions stratified to provide data for days 1, 2, 3, 7, 8, 9, 12, 13, or 14 of sensor wear. Participants aged 11+ underwent supervised glycemic manipulation during in-clinic sessions to achieve glucose levels across the measurement range of the System. Performance evaluation included accuracy measures such as the proportion of continuous glucose monitoring (CGM) values that were within ±20% or ±20 mg/dL of reference glucose values, and bias measures such as the mean absolute relative difference (MARD) between CGM and reference values. RESULTS: Data from the 144 adults and 129 pediatric participants were analyzed. Percent of sensor results within ±20%/20 mg/dL of YSI reference were 93.2% and 92.1%, and MARD was 9.2% and 9.7% for the adults and pediatric participants, respectively. The System performed well in the hypoglycemic range, with 94.3% of the results for the adult population and 96.1% of the data for pediatric population being within 15 mg/dL of the YSI reference. The time lag was 2.4 ± 4.6 minutes for adults and 2.1 ± 5.0 minutes for pediatrics. CONCLUSIONS: The System demonstrated improved analytical accuracy performance across the dynamic range during the 14-day sensor wear period as compared to the previous-generation device.NCT#: NCT03607448 and NCT03820050.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Pediatría , Adulto , Anciano , Algoritmos , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Glucosa , Humanos , Reproducibilidad de los Resultados
9.
Diabetes Technol Ther ; 24(2): 84-92, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34515521

RESUMEN

Background: Use of continuous glucose monitoring (CGM) systems is being rapidly adopted as standard of care for insulin-requiring patients with diabetes. The PROMISE study (NCT03808376) evaluated the accuracy and safety of the next-generation implantable Eversense CGM system for up to 180 days. Methods: This was a prospective multicenter study involving 181 subjects with diabetes at 8 USA sites. All subjects were inserted with a primary sensor. Ninety-six subjects had a second sensor, either an identical sensor or a modified sensor (sacrificial boronic acid [SBA]), inserted in their other arm (53 and 43 subjects, respectively). Accuracy was evaluated by comparing CGM to YSI 2300 glucose analyzer (Yellow Springs Instrument [YSI]) values during 10 clinic visits (day 1-180). Confirmed event detection rates, calibration stability, sensor survival, and serious adverse events (SAEs) were evaluated. Results: For primary sensors, the percent CGM readings within 20%/20% of YSI values was 92.9%; overall mean absolute relative difference (MARD) was 9.1%. The confirmed alert detection rate at 70 mg/dL was 93% and at 180 mg/dL was 99%. The median percentage of time for one calibration per day was 56%. Sixty-five percent of the primary sensors survived to 180 days. For the SBA sensors, the percent CGM readings within 20%/20% of YSI values was 93.9%; overall MARD was 8.5%. The confirmed alert detection rate at 70 mg/dL was 94% and at 180 mg/dL was 99%. The median percentage of time for one calibration per day was 63%. Ninety percent of the SBA sensors survived to 180 days. No device- or insertion/removal procedure-related SAEs were reported. Conclusion: These data show the next-generation Eversense CGM system had sustained accuracy and safety up to 180 days, with an improved calibration scheme and survival, using the primary or SBA sensors.


Asunto(s)
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados
10.
JAMA Netw Open ; 4(11): e2134254, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34779843

RESUMEN

Importance: Diabetic retinopathy (DR) is a leading cause of blindness in adults worldwide. Early detection and intervention can prevent blindness; however, many patients do not receive their recommended annual diabetic eye examinations, primarily owing to limited access. Objective: To evaluate the safety and accuracy of an artificial intelligence (AI) system (the EyeArt Automated DR Detection System, version 2.1.0) in detecting both more-than-mild diabetic retinopathy (mtmDR) and vision-threatening diabetic retinopathy (vtDR). Design, Setting, and Participants: A prospective multicenter cross-sectional diagnostic study was preregistered (NCT03112005) and conducted from April 17, 2017, to May 30, 2018. A total of 942 individuals aged 18 years or older who had diabetes gave consent to participate at 15 primary care and eye care facilities. Data analysis was performed from February 14 to July 10, 2019. Interventions: Retinal imaging for the autonomous AI system and Early Treatment Diabetic Retinopathy Study (ETDRS) reference standard determination. Main Outcomes and Measures: Primary outcome measures included the sensitivity and specificity of the AI system in identifying participants' eyes with mtmDR and/or vtDR by 2-field undilated fundus photography vs a rigorous clinical reference standard comprising reading center grading of 4 wide-field dilated images using the ETDRS severity scale. Secondary outcome measures included the evaluation of imageability, dilated-if-needed analysis, enrichment correction analysis, worst-case imputation, and safety outcomes. Results: Of 942 consenting individuals, 893 patients (1786 eyes) met the inclusion criteria and completed the study protocol. The population included 449 men (50.3%). Mean (SD) participant age was 53.9 (15.2) years (median, 56; range, 18-88 years), 655 were White (73.3%), and 206 had type 1 diabetes (23.1%). Sensitivity and specificity of the AI system were high in detecting mtmDR (sensitivity: 95.5%; 95% CI, 92.4%-98.5% and specificity: 85.0%; 95% CI, 82.6%-87.4%) and vtDR (sensitivity: 95.1%; 95% CI, 90.1%-100% and specificity: 89.0%; 95% CI, 87.0%-91.1%) without dilation. Imageability was high without dilation, with the AI system able to grade 87.4% (95% CI, 85.2%-89.6%) of the eyes with reading center grades. When eyes with ungradable results were dilated per the protocol, the imageability improved to 97.4% (95% CI, 96.4%-98.5%), with the sensitivity and specificity being similar. After correcting for enrichment, the mtmDR specificity increased to 87.8% (95% CI, 86.3%-89.5%) and the sensitivity remained similar; for vtDR, both sensitivity (97.0%; 95% CI, 91.2%-100%) and specificity (90.1%; 95% CI, 89.4%-91.5%) improved. Conclusions and Relevance: This prospective multicenter cross-sectional diagnostic study noted safety and accuracy with use of the EyeArt Automated DR Detection System in detecting both mtmDR and, for the first time, vtDR, without physician assistance. These findings suggest that improved access to accurate, reliable diabetic eye examinations may increase adherence to recommended annual screenings and allow for accelerated referral of patients identified as having vtDR.


Asunto(s)
Inteligencia Artificial/estadística & datos numéricos , Retinopatía Diabética/diagnóstico , Derivación y Consulta/estadística & datos numéricos , Trastornos de la Visión/diagnóstico , Selección Visual/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Retinopatía Diabética/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estándares de Referencia , Sensibilidad y Especificidad , Trastornos de la Visión/etiología , Selección Visual/normas , Adulto Joven
11.
Diabetes Technol Ther ; 23(8): 537-545, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33826420

RESUMEN

Background: The COVID-19 pandemic has impacted the conduct of clinic visits. We conducted a study to evaluate two academic laboratories' fingerstick capillary blood collection kits suitable for home use for laboratory measurement of HbA1c. Methods: Four clinical sites recruited 240 participants (aged 4-80 years, HbA1c 5.1%-13.5%). Capillary blood samples were obtained by the participant or parent using collection kits from two laboratories (University of Minnesota Advanced Research and Diagnostic Laboratory (ARDL) and Children's Mercy Hospital Laboratory (CMH)) and mailed under varying shipping conditions by United States Postal Service to the laboratories. Comparisons were made between HbA1c measurements from capillary samples and contemporaneously obtained venous samples. The primary outcome was percentage of capillary HbA1c values within 5% of the corresponding venous values. Results: HbA1c values were within 5% of venous values for 96% of ARDL kit specimens shipped with a cold pack and 98% without a cold pack and 99% and 99%, respectively, for the CMH kits. R2 values were 0.98, 0.99, 0.99, and 0.99, respectively. Results appeared similar across HbA1c levels and for pediatric and adult participants. Usability survey scores were high. Conclusions: Capillary blood collection kits, suitable for home use, from two academic laboratories, were demonstrated to be easy to use and provided results that are comparable with those obtained from venous specimens. Based on these results, there is strong evidence that HbA1c measurements from capillary specimens obtained with these specific kits can be used interchangeably with HbA1c measurements from venous specimens for clinical research and clinical care.


Asunto(s)
Recolección de Muestras de Sangre/instrumentación , COVID-19 , Capilares , Diabetes Mellitus/sangre , Hemoglobina Glucada/análisis , SARS-CoV-2 , Adolescente , Adulto , Anciano , Niño , Preescolar , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Manejo de Especímenes/métodos , Venas
12.
JAMA ; 323(23): 2388-2396, 2020 06 16.
Artículo en Inglés | MEDLINE | ID: mdl-32543683

RESUMEN

Importance: Adolescents and young adults with type 1 diabetes exhibit the worst glycemic control among individuals with type 1 diabetes across the lifespan. Although continuous glucose monitoring (CGM) has been shown to improve glycemic control in adults, its benefit in adolescents and young adults has not been demonstrated. Objective: To determine the effect of CGM on glycemic control in adolescents and young adults with type 1 diabetes. Design, Setting, and Participants: Randomized clinical trial conducted between January 2018 and May 2019 at 14 endocrinology practices in the US including 153 individuals aged 14 to 24 years with type 1 diabetes and screening hemoglobin A1c (HbA1c) of 7.5% to 10.9%. Interventions: Participants were randomized 1:1 to undergo CGM (CGM group; n = 74) or usual care using a blood glucose meter for glucose monitoring (blood glucose monitoring [BGM] group; n = 79). Main Outcomes and Measures: The primary outcome was change in HbA1c from baseline to 26 weeks. There were 20 secondary outcomes, including additional HbA1c outcomes, CGM glucose metrics, and patient-reported outcomes with adjustment for multiple comparisons to control for the false discovery rate. Results: Among the 153 participants (mean [SD] age, 17 [3] years; 76 [50%] were female; mean [SD] diabetes duration, 9 [5] years), 142 (93%) completed the study. In the CGM group, 68% of participants used CGM at least 5 days per week in month 6. Mean HbA1c was 8.9% at baseline and 8.5% at 26 weeks in the CGM group and 8.9% at both baseline and 26 weeks in the BGM group (adjusted between-group difference, -0.37% [95% CI, -0.66% to -0.08%]; P = .01). Of 20 prespecified secondary outcomes, there were statistically significant differences in 3 of 7 binary HbA1c outcomes, 8 of 9 CGM metrics, and 1 of 4 patient-reported outcomes. The most commonly reported adverse events in the CGM and BGM groups were severe hypoglycemia (3 participants with an event in the CGM group and 2 in the BGM group), hyperglycemia/ketosis (1 participant with an event in CGM group and 4 in the BGM group), and diabetic ketoacidosis (3 participants with an event in the CGM group and 1 in the BGM group). Conclusions and Relevance: Among adolescents and young adults with type 1 diabetes, continuous glucose monitoring compared with standard blood glucose monitoring resulted in a small but statistically significant improvement in glycemic control over 26 weeks. Further research is needed to understand the clinical importance of the findings. Trial Registration: ClinicalTrials.gov Identifier: NCT03263494.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Diabetes Mellitus Tipo 1/sangre , Hemoglobina Glucada/análisis , Hipoglucemiantes/administración & dosificación , Adolescente , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/instrumentación , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Cetoacidosis Diabética , Femenino , Humanos , Hiperglucemia/diagnóstico , Hiperglucemia/prevención & control , Hipoglucemia/inducido químicamente , Hipoglucemia/diagnóstico , Hipoglucemia/prevención & control , Hipoglucemiantes/efectos adversos , Masculino , Aplicaciones Móviles , Monitoreo Ambulatorio/instrumentación , Adulto Joven
13.
Diabetes Technol Ther ; 21(1): 11-19, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30585770

RESUMEN

OBJECTIVE: To evaluate the safety of in-home use of the MiniMed™ 670G system with SmartGuard™ technology in children with type 1 diabetes (T1D). METHODS: Participants (N = 105, ages 7-13 years, mean age 10.8 ± 1.8 years) were enrolled at nine centers (eight in the United States and one in Israel) and completed a 2-week baseline run-in phase in Manual Mode followed by a 3-month study phase with Auto Mode enabled. Sensor glucose (SG), glycated hemoglobin (HbA1c), percentage of SG values across glucose ranges, and SG variability, during the run-in and study phases were compared. Participants underwent frequent sample testing with i-STAT® venous reference measurement during a hotel period (6 days/5 nights) to evaluate the system's continuous glucose monitoring performance. RESULTS: Auto Mode was used a median of 81% of the time. From baseline to end of study, overall SG dropped by 6.9 ± 17.2 mg/dL (P < 0.001), HbA1c decreased from 7.9% ± 0.8% to 7.5% ± 0.6% (P < 0.001), percentage of time in target glucose range (70-180 mg/dL) increased from 56.2% ± 11.4% to 65.0% ± 7.7% (P < 0.001), and the SG coefficient of variation decreased from 39.6% ± 5.4% to 38.5% ± 3.8% (P = 0.009). The percentage of SG values within target glucose range was 68.2% ± 9.1% and that of i-STAT reference values was 65.6% ± 17.7%. The percentage of values within 20%/20 of the i-STAT reference was 85.2%. There were no episodes of severe hypoglycemia or diabetic ketoacidosis during the study phase. CONCLUSION: In-home use of MiniMed 670G system Auto Mode for 3 months by children with T1D, similar to MiniMed 670G system use by adolescents and adults with T1D, was safe and associated with reduced HbA1c levels and increased time in target glucose range, compared with baseline.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina/estadística & datos numéricos , Insulina/administración & dosificación , Adolescente , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Niño , Diabetes Mellitus Tipo 1/sangre , Femenino , Hemoglobina Glucada/análisis , Humanos , Masculino , Resultado del Tratamiento
14.
Diabetes Technol Ther ; 20(11): 731-737, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30299976

RESUMEN

BACKGROUND: The Medtronic predictive low-glucose management (PLGM) algorithm automatically stops insulin delivery when sensor glucose (SG) is predicted to reach or fall below a preset low-glucose value within the next 30 min, and resumes delivery after hypoglycemia recovery. The present study evaluated the PLGM algorithm performance of the MiniMed™ 670G system SmartGuard™ "suspend before low" feature in children aged 7-13 years with type 1 diabetes (T1D). METHOD: Participants (N = 105, mean ± standard deviation of 10.8 ± 1.8 years) underwent an overnight in-clinic evaluation of the "suspend before low" feature with a preset low limit of 65 mg/dL. After exercise, frequent sample testing (FST) was conducted every 5 min if values were <70 mg/dL; every 15 min if 70-80 mg/dL; and every 30 min if >80 mg/dL. First-day performance of the Guardian™ Sensor 3 glucose sensor and continuous glucose monitoring system was also evaluated. RESULTS: Activation of the "suspend before low" feature occurred in 79 of the 105 participants, 79.7% (63/79) did not result in SG falling below 65 mg/dL. Mean glucose at activation was 102 ± 19 mg/dL and the initial insulin suspension duration was 87.5 ± 32.7 min. Four hours after insulin resumption, mean reference glucose was 130 ± 42 mg/dL. Mean absolute relative difference between the FST reference glucose and SG values on the first day of sensor wear was 11.4%. For the 26 participants in whom the "suspend before low" feature did not activate, none involved a reference glucose value ≤65 mg/dL, suggesting that the PLGM algorithm performed as intended. CONCLUSION: In children aged 7-13 years with T1D, the "suspend before low" feature of the MiniMed 670G system demonstrated a hypoglycemia prevention rate of nearly 80% after exercise and did not involve rebound hyperglycemia. There were no events of severe hypoglycemia during the evaluation.


Asunto(s)
Algoritmos , Glucemia/análisis , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Adolescente , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Niño , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Ejercicio Físico/fisiología , Femenino , Humanos , Hiperglucemia/sangre , Hiperglucemia/etiología , Hiperglucemia/prevención & control , Hipoglucemia/sangre , Hipoglucemia/etiología , Insulina/análisis , Masculino , Valores de Referencia , Factores de Tiempo , Resultado del Tratamiento
15.
Diabetes Care ; 39(4): 603-10, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26681721

RESUMEN

OBJECTIVE: Severe hypoglycemia is common in older adults with long-standing type 1 diabetes, but little is known about factors associated with its occurrence. RESEARCH DESIGN AND METHODS: A case-control study was conducted at 18 diabetes centers in the T1D Exchange Clinic Network. Participants were ≥60 years old with type 1 diabetes for ≥20 years. Case subjects (n = 101) had at least one severe hypoglycemic event in the prior 12 months. Control subjects (n = 100), frequency-matched to case subjects by age, had no severe hypoglycemia in the prior 3 years. Data were analyzed for cognitive and functional abilities, social support, depression, hypoglycemia unawareness, various aspects of diabetes management, C-peptide level, glycated hemoglobin level, and blinded continuous glucose monitoring (CGM) metrics. RESULTS: Glycated hemoglobin (mean 7.8% vs. 7.7%) and CGM-measured mean glucose (175 vs. 175 mg/dL) were similar between case and control subjects. More case than control subjects had hypoglycemia unawareness: only 11% of case subjects compared with 43% of control subjects reported always having symptoms associated with low blood glucose levels (P < 0.001). Case subjects had greater glucose variability than control subjects (P = 0.008) and experienced CGM glucose levels <60 mg/dL for ≥20 min on 46% of days compared with 33% of days in control subjects (P = 0.10). On certain cognitive tests, case subjects scored worse than control subjects. CONCLUSIONS: In older adults with long-standing type 1 diabetes, greater hypoglycemia unawareness and glucose variability are associated with an increased risk of severe hypoglycemia. A study to assess interventions to prevent severe hypoglycemia in high-risk individuals is needed.


Asunto(s)
Diabetes Mellitus Tipo 1/sangre , Hipoglucemia/sangre , Anciano , Glucemia/metabolismo , Péptido C/sangre , Estudios de Casos y Controles , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemia/complicaciones , Hipoglucemiantes/uso terapéutico , Masculino , Persona de Mediana Edad , Factores de Riesgo
16.
Diabetes Care ; 38(3): 476-81, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25519448

RESUMEN

OBJECTIVE: It is generally accepted that complete ß-cell destruction eventually occurs in individuals with type 1 diabetes, which has implications for treatment approaches and insurance coverage. The frequency of residual insulin secretion in a large cohort of individuals at varying ages of diagnosis and type 1 diabetes duration is unknown. RESEARCH DESIGN AND METHODS: The frequency of residual insulin secretion was determined by measurement of nonfasting serum C-peptide concentration in 919 individuals with type 1 diabetes according to prespecified groups based on age at diagnosis and duration of disease (from 3 to 81 years' duration). Stimulated C-peptide was measured in those with detectable nonfasting values and a group of those with undetectable values as control. RESULTS: The overall frequency of detectable nonfasting C-peptide was 29%, decreasing with time from diagnosis regardless of age at diagnosis. In all duration groups, the frequency of C-peptide was higher with diagnosis age >18 years compared with ≤18 years. Nineteen percent of those with undetectable nonfasting C-peptide were C-peptide positive upon stimulation testing. CONCLUSIONS: The American Diabetes Association's definition of type 1 diabetes as "usually leading to absolute insulin deficiency" results in clinicians often considering the presence of residual insulin secretion as unexpected in this population. However, our data suggest that residual secretion is present in almost one out of three individuals 3 or more years from type 1 diabetes diagnosis. The frequency of residual C-peptide decreases with time from diagnosis regardless of age at diagnosis, yet at all durations of disease, diagnosis during adulthood is associated with greater frequency and higher values of C-peptide.


Asunto(s)
Péptido C/sangre , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Péptido C/metabolismo , Niño , Preescolar , Diabetes Mellitus Tipo 1/diagnóstico , Femenino , Humanos , Insulina/metabolismo , Secreción de Insulina , Células Secretoras de Insulina/metabolismo , Masculino , Persona de Mediana Edad , Prevalencia , Adulto Joven
17.
Diabetes Technol Ther ; 15(10): 881-8, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23777402

RESUMEN

BACKGROUND: Use of continuous glucose monitoring (CGM) systems can improve glycemic control, but widespread adoption of CGM utilization has been limited, in part because of real and perceived problems with accuracy and reliability. This study compared accuracy and performance metrics for a new-generation CGM system with those of a previous-generation device. SUBJECTS AND METHODS: Subjects were enrolled in a 7-day, open-label, multicenter pivotal study. Sensor readings were compared with venous YSI measurements (blood glucose analyzer from YSI Inc., Yellow Springs, OH) every 15 min (±5 min) during in-clinic visits. The aggregate and individual sensor accuracy and reliability of a new CGM system, the Dexcom(®) (San Diego, CA) G4™ PLATINUM (DG4P), were compared with those of the previous CGM system, the Dexcom SEVEN(®) PLUS (DSP). RESULTS: Both study design and subject characteristics were similar. The aggregate mean absolute relative difference (MARD) for DG4P was 13% compared with 16% for DSP (P<0.0001), and 82% of DG4P readings were within ± 20 mg/dL (for YSI ≤ 80 mg/dL) or 20% of YSI values (for YSI >80 mg/dL) compared with 76% for DSP (P<0.001). Ninety percent of the DG4P sensors had an individual MARD ≤ 20% compared with only 76% of DSP sensors (P=0.015). Half of DG4P sensors had a MARD less than 12.5% compared with 14% for the DSP sensors (P=0.028). The mean absolute difference for biochemical hypoglycemia (YSI <70 mg/dL) for DG4P was 11 mg/dL compared with 16 mg/dL for DSP (P<0.001). CONCLUSIONS: The performance of DG4P was significantly improved compared with that of DSP, which may increase routine clinical use of CGM and improve patient outcomes.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 2/sangre , Hipoglucemia/sangre , Monitoreo Ambulatorio , Adolescente , Adulto , Anciano , Ansiedad/etiología , Técnicas Biosensibles , Automonitorización de la Glucosa Sanguínea/tendencias , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Humanos , Hipoglucemia/complicaciones , Hipoglucemia/epidemiología , Hipoglucemia/prevención & control , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio/tendencias , Cooperación del Paciente , Reproducibilidad de los Resultados , Resultado del Tratamiento , Estados Unidos/epidemiología
18.
J Clin Endocrinol Metab ; 91(1): 48-53, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16249284

RESUMEN

CONTEXT: Polycystic ovary syndrome (PCOS) and the metabolic syndrome have many features in common and may share the same pathogenesis. OBJECTIVE: This study was performed to determine the prevalence and predictors of the metabolic syndrome in PCOS. DESIGN: The clinical, hormonal, and oral glucose tolerance test results were analyzed in 394 PCOS women who were screened for participation in a multicenter trial to evaluate the effects of troglitazone on ovulation and hirsutism. SETTING: A multicenter clinical trial is presented. PATIENTS OR OTHER PARTICIPANTS: The subjects were women with PCOS who had or lacked the metabolic syndrome. MAIN OUTCOME MEASURES: Waist circumference, fasting glucose, high-density lipoprotein cholesterol and triglyceride concentrations, and blood pressure were the main outcome measures. RESULTS: Twenty-six (6.6%) subjects had diabetes; among the 368 nondiabetics, the prevalence for individual components comprising the metabolic syndrome were: waist circumference greater than 88 cm in 80%, high-density lipoprotein cholesterol less than 50 mg/dl in 66%, triglycerides greater than or equal to 150 mg/dl in 32%, blood pressure greater than or equal to 130/85 mm Hg in 21%, and fasting glucose concentrations greater than or equal to 110 mg/dl in 5%. Three or more of these individual criteria were present in 123 (33.4%) subjects overall. The prevalence of the metabolic syndrome did not differ significantly between racial/ethnic groups. The prevalence of the metabolic syndrome from lowest to highest quartile of free testosterone concentration was 19.8, 31.3, 46.9, and 35.0%, respectively [P = 0.056 adjusted for body mass index (BMI)]. None of the 52 women with a BMI less than 27.0 kg/m2 had the metabolic syndrome; those in the top BMI quartile were 13.7 times more likely (95% confidence interval, 5.7-33.0) to have the metabolic syndrome compared with those in the lowest quartile. Thirty-eight percent of those with the metabolic syndrome had impaired glucose tolerance compared with 19% without the metabolic syndrome (P < 0.001). CONCLUSIONS: The metabolic syndrome and its individual components are common in PCOS, particularly among women with the highest insulin levels and BMI. Hyperinsulinemia is a likely common pathogenetic factor for both PCOS and the metabolic syndrome.


Asunto(s)
Síndrome Metabólico/epidemiología , Síndrome Metabólico/etiología , Síndrome del Ovario Poliquístico/complicaciones , Adulto , Biomarcadores , Glucemia/metabolismo , Presión Sanguínea/fisiología , HDL-Colesterol/sangre , Estudios de Cohortes , Diabetes Mellitus/genética , Femenino , Prueba de Tolerancia a la Glucosa , Humanos , Insulina/sangre , Obesidad/epidemiología , Valor Predictivo de las Pruebas , Testosterona/sangre , Relación Cintura-Cadera
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...