Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Intervalo de año de publicación
1.
Dent Mater J ; 43(1): 52-57, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38044145

RESUMEN

This study investigated the degree of phase transformation, surface roughness, and bond strength of zirconia immersed for various times in a 40% hydrofluoric acid (HF) solution. Non-etched sintered zirconia specimens were used as the control, while experimental groups were etched with a 40% HF solution for 5, 10, 20, 40, 80, 160 and 320 min. In each of the control and experimental groups, five specimens for X-ray diffraction analysis, four for surface morphology and surface roughness analysis, and ten for bonding strength measurement were used. As a result, the surface roughness of zirconia increased as the application time increased during the 40% HF etching, but the bond strength between zirconia and resin cement did not increase proportionally. The phase transformation from tetragonal to monoclinic also gradually increased with application time.


Asunto(s)
Recubrimiento Dental Adhesivo , Ácido Fluorhídrico , Ácido Fluorhídrico/química , Inmersión , Circonio/química , Propiedades de Superficie , Cementos de Resina/química , Ensayo de Materiales , Cerámica/química
2.
Appl Opt ; 62(17): F21-F30, 2023 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-37707127

RESUMEN

Image sensors are must-have components of most consumer electronics devices. They enable portable camera systems, which find their way into billions of devices annually. Such high volumes are possible thanks to the complementary metal-oxide semiconductor (CMOS) platform, leveraging wafer-scale manufacturing. Silicon photodiodes, at the core of CMOS image sensors, are perfectly suited to replicate human vision. Thin-film absorbers are an alternative family of photoactive materials, distinguished by the layer thickness comparable with or smaller than the wavelength of interest. They allow design of imagers with functionalities beyond Si-based sensors, such as transparency or detectivity at wavelengths above Si cutoff (e.g., short-wave infrared). Thin-film image sensors are an emerging device category. While intensive research is ongoing to achieve sufficient performance of thin-film photodetectors, to our best knowledge, there have been few complete studies on their integration into advanced systems. In this paper, we will describe several types of image sensors being developed at imec, based on organic, quantum dot, and perovskite photodiode and show their figures of merit. We also discuss the methodology for selecting the most appropriate sensor architecture (integration with thin-film transistor or CMOS). Application examples based on imec proof-of-concept sensors are demonstrated to showcase emerging use cases.

3.
Restor Dent Endod ; 46(4): e54, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34909418

RESUMEN

OBJECTIVES: The purpose of this study was to quantify phase transformation after hydrofluoric acid (HF) etching at various concentrations on the surface of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP), and to evaluate changes in bonding strength before and after thermal cycling. MATERIALS AND METHODS: A group whose Y-TZP surface was treated with tribochemical silica abrasion (TS) was used as the control. Y-TZP specimens from each experimental group were etched with 5%, 10%, 20%, and 40% HF solutions at room temperature for 10 minutes. First, to quantify the phase transformation, Y-TZP specimens (n = 5) treated with TS, 5%, 10%, 20% and 40% HF solutions were subjected to X-ray diffraction. Second, to evaluate the change in bond strength before and after thermal cycling, zirconia primer and MDP-containing resin cement were sequentially applied to the Y-TZP specimen. After 5,000 thermal cycles for half of the Y-TZP specimens, shear bond strength was measured for all experimental groups (n = 10). RESULTS: The monoclinic phase content in the 40% HF-treated group was higher than that of the 5%, 10%, and 20% HF-treated groups, but lower than that of TS-treated group (p < 0.05). The 40% HF-treated group showed significantly higher bonding strength than the TS, 5%, and 10% HF-treated groups, even after thermal cycling (p < 0.05). CONCLUSIONS: Through this experiment, the group treated with SiO2 containing air-borne abrasion on the Y-TZP surface showed higher phase transformation and higher reduction in bonding strength after thermal cycling compared to the group treated with high concentration HF.

4.
Medicina (Kaunas) ; 56(11)2020 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-33126472

RESUMEN

Background and objectives: This study aimed to investigate the change in bond strength between resin cement and tetragonal zirconia polycrystalline stabilized with 3 to 8 mol% yttrium oxide (Y-TZP) and observe the topographical change of the Y-TZP surface when etched with hydrofluoric acid (HF) solution under different concentration and temperature conditions. Materials and Methods: Non-etched sintered Y-TZP specimens under two different temperature conditions (room temperature and 70-80 °C, respectively), were used as a control, while experimental groups were etched with 5%, 10%, 20%, and 40% HF solutions for 10 min. After zirconia primer and MDP-containing resin cement were applied to the Y-TZP surface, the shear bond strength (SBS) of each experimental group was measured. Results: Under room temperature conditions, the highest SBS value was measured in the 40% HF etching group, representing a significant deviation from the other groups (p < 0.05). In the 70-80 °C tests, the 40% HF etching group also had the highest SBS value, but there was no significant difference when compared to the 20% HF etching group (p > 0.05). From SEM and AFM observations, the HF solution increasingly dissolved the Y-TZP surface grain structure as the concentration and application temperature rose, resulting in high surface roughness and irregularities. Conclusions: Pretreating with either 20% HF solution at 70-80 °C or 40% HF solution at room temperature and 70-80 °C effectively acid etched the Y-TZP surface, resulting in more surface roughness and irregularities. Accounting for the concentration and temperature conditions of the HF solution, using 40% HF solution at room temperature will result in improvements in adhesion between resin cement and Y-TZP.


Asunto(s)
Ácido Fluorhídrico , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Temperatura
5.
Restor Dent Endod ; 45(1): e6, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32110535

RESUMEN

OBJECTIVES: This study investigated the effects of a hydrofluoric acid (HA; solution of hydrogen fluoride [HF] in water)-based smart etching (SE) solution at an elevated temperature on yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) ceramics in terms of bond strength and morphological changes. MATERIALS AND METHODS: Eighty sintered Y-TZP specimens were prepared for shear bond strength (SBS) testing. The bonding surface of the Y-TZP specimens was treated with 37% phosphoric acid etching at 20°C-25°C, 4% HA etching at 20°C-25°C, or HA-based SE at 70°C-80°C. In all groups, zirconia primers were applied to the bonding surface of Y-TZP. For each group, 2 types of resin cement (with or without methacryloyloxydecyl dihydrogen phosphate [MDP]) were used. SBS testing was performed. Topographic changes of the etched Y-TZP surface were analyzed using scanning electron microscopy and atomic force microscopy. The results were analyzed and compared using 2-way analysis of variance. RESULTS: Regardless of the type of resin cement, the highest bond strength was measured in the SE group, with significant differences compared to the other groups (p < 0.05). In all groups, MDP-containing resin cement yielded significantly higher bond strength values than MDP-free resin cement (p < 0.05). It was also shown that the Y-TZP surface was etched by the SE solution, causing a large change in the surface topography. CONCLUSIONS: Bond strength significantly improved when a heated HA-based SE solution was applied to the Y-TZP surface, and the etched Y-TZP surface was more irregular and had higher surface roughness.

6.
Dent Mater J ; 39(1): 154-160, 2020 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-31694996

RESUMEN

This study investigated the effects of different silica-based layer coatings on shear bond strength (SBS) between Y-TZP and bovine dentin. Three different silica-based layer coatings were applied to the Y-TZP surface: tribochemical silica coating, vitrification (glaze coating), and composite resin sintering. A silane coupling agent (SIL) was applied to the silica-coated Y-TZP surface in the presence or absence of hydrofluoric acid (HF) treatment. A one-step adhesive was then applied to the silica-coated Y-TZP and cemented to bovine dentin using MDP-free resin cement. The SBS value of the tribochemical silica coating group was lowest among the experimental groups, while the HF+SIL subgroup showed the highest SBS value after vitrification (p<0.05). While hydrofluoric acid etching did not affect the SBS value of the tribochemical silica coating group, it affected the SBS value in the vitrification and composite resin sintering groups (p<0.05).


Asunto(s)
Recubrimiento Dental Adhesivo , Dióxido de Silicio , Animales , Bovinos , Dentina , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie , Itrio , Circonio
7.
Restor Dent Endod ; 43(2): e19, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29765899

RESUMEN

OBJECTIVES: This study investigated the effect of continuous application of 10-methacryloyloxydecyldihydrogen phosphate (MDP)-containing primer and luting resin cement on bond strength to tribochemical silica-coated yttria-stabilized tetragonal zirconia polycrystal (Y-TZP). MATERIALS AND METHODS: Forty bovine teeth and Y-TZP specimens were prepared. The dentin specimens were embedded in molds, with one side of the dentin exposed for cementation with the zirconia specimen. The Y-TZP specimen was prepared in the form of a cylinder with a diameter of 3 mm and a height of 10 mm. The bonding surface of the Y-TZP specimen was sandblasted with silica-coated aluminium oxide particles. The forty tribochemical silica-coated Y-TZP specimens were cemented to the bovine dentin (4 groups; n = 10) with either an MDP-free primer or an MDP-containing primer and either an MDP-free resin cement or an MDP-containing resin cement. After a shear bond strength (SBS) test, the data were analyzed using 1-way analysis of variance and the Tukey test (α = 0.05). RESULTS: The group with MDP-free primer and resin cement showed significantly lower SBS values than the MDP-containing groups (p < 0.05). Among the MDP-containing groups, the group with MDP-containing primer and resin cement showed significantly higher SBS values than the other groups (p < 0.05). CONCLUSIONS: The combination of MDP-containing primer and luting cement following tribochemical silica coating to Y-TZP was the best choice among the alternatives tested in this study.

8.
Materials (Basel) ; 11(1)2018 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-29303973

RESUMEN

This study was performed to evaluate the effect of a lithium-disilicate spray-liner application on both the bond strength between zirconia cores and heat-pressed lithium-disilicate glass-ceramic veneers, and the fracture strength of all-ceramic zirconia crowns. A lithium-disilicate reinforced liner was applied on the surface of a zirconia core and lithium-disilicate glass-ceramic was veneered on zirconia through heat press forming. Microtensile and crown fracture tests were conducted in order to evaluate, respectively, the bonding strength between the zirconia cores and heat pressed lithium-disilicate glass-ceramic veneers, and the fracture strength of bilayered zirconia all-ceramic crowns. The role of lithium-disilicate spray-liner at the interface between zirconia and lithium-disilicate glass-ceramic veneers was investigated through surface and cross-sectional analyses. We confirmed that both the mean bonding strength between the zirconia ceramics and lithium-disilicate glass-ceramic veneers and the fracture strength of the liner-treated groups were significantly higher than those of the untreated groups, which resulted, on the one hand, from the chemical bonding at the interface of the zirconia and lithium-disilicate liner, and, on the other, from the existence of a microgap in the group not treated with liner.

9.
Restor Dent Endod ; 42(4): 290-300, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29142877

RESUMEN

OBJECTIVES: This study investigated the removal efficacy and cytotoxicity of a newly developed calcium hydroxide paste (cleaniCal, Maruchi) using N-2-methyl-pyrrolidone (NMP) as a vehicle in comparison with ApexCal (Ivoclar Vivadent) and Calcipex II (Nishika), which use different vehicles such as polyethylene glycol and propylene glycol, respectively. MATERIALS AND METHODS: Thirty maxillary premolars with oval-shaped canals were divided into 3 groups and the teeth were filled with one of the pastes. After removal of the paste, micro-computed tomographic (µ-CT) imaging was obtained to assess the volume of residual paste in the root canal of each tooth. The teeth were then split longitudinally and the area of the paste-coated surface was evaluated by stereomicroscopy. The cytotoxicity of each product was assessed using an agar overlay assay. The effect of each vehicle on cell viability was evaluated using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. The data were analyzed using one-way analysis of variance and Tukey's tests to detect any significance (p < 0.05). RESULTS: In the µ-CT and stereomicroscopic analysis, cleaniCal exhibited less remnants of medicament than ApexCal and Calcipex. cleaniCal showed a higher cytotoxicity than the other pastes in the agar overlay assay. Furthermore, NMP exhibited lower cell viability compared to the other vehicles. CONCLUSIONS: cleaniCal showed better removal efficacy compared to the other products. However, clinicians should be aware of the higher cytotoxicity of the NMP-based material and consider its possible adverse effects on periradicular tissue when it is overfilled.

10.
Eur J Dent ; 11(1): 122-125, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28435378

RESUMEN

Although vertical root fracture (VRF) is mostly found in endodontically treated teeth, it also occurs spontaneously. If VRF is recognized after endodontic treatment, it is considered to be iatrogenic and can lead to legal trouble. However, legal problems can be averted if the dentist can prove that the VRF existed before endodontic treatment. This case report describes an unusual, spontaneous VRF in an endodontically treated tooth and presents a useful tip for determining whether a fracture is iatrogenic. We performed nonsurgical endodontic treatment on a mandibular first molar with irreversible pulpitis. After 6 months, the patient revisited with localized swelling, and we diagnosed VRF of the mesial root. We extracted the tooth and prepared it for microscopic examination. We found gutta-percha in the fracture line of the transversely sectioned root, and it appeared to have penetrated to the fracture line through the force generated from the filling. The patient was informed and agreed that the fracture occurred spontaneously before treatment. This case demonstrates the time point of VRF occurrence by identifying the presence of gutta-percha in the fracture line. We suggest that this procedure can be used to demonstrate whether VRFs in endodontically treated teeth are spontaneous or iatrogenic.

11.
Restor Dent Endod ; 42(1): 1-8, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28194358

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the effect of adhesive luting on the fracture resistance of zirconia compared to that of a composite resin and a lithium disilicate glass ceramic. MATERIALS AND METHODS: The specimens (dimension: 2 mm × 2 mm × 25 mm) of the composite resin, lithium disilicate glass ceramic, and yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) were prepared. These were then divided into nine groups: three non-luting groups, three non-adhesive luting groups, and three adhesive luting groups, for each restorative material. In the non-luting groups, specimens were placed on the bovine tooth without any luting agents. In the non-adhesive luting groups, only zinc phosphate cement was used for luting the specimen to the bovine tooth. In the adhesive luting groups, specimens were pretreated, and the adhesive luting procedure was performed using a self-adhesive resin cement. For all the groups, a flexural test was performed using universal testing machine, in which the fracture resistance was measured by recording the force at which the specimen was fractured. RESULTS: The fracture resistance after adhesive luting increased by approximately 29% in the case of the composite resin, 26% in the case of the lithium disilicate glass ceramic, and only 2% in the case of Y-TZP as compared to non-adhesive luting. CONCLUSIONS: The fracture resistance of Y-TZP did not increased significantly after adhesive luting as compared to that of the composite resin and the lithium disilicate glass ceramic.

12.
Restor Dent Endod ; 41(3): 189-95, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27508160

RESUMEN

OBJECTIVES: A variety of root canal sealers were recently launched to the market. This study evaluated physicochemical properties, biocompatibility, and sealing ability of a newly launched resin-based sealer (Dia-Proseal, Diadent) compared to the existing root canal sealers (AHplus, Dentsply DeTrey and ADseal, Metabiomed). MATERIALS AND METHODS: The physicochemical properties of the tested sealers including pH, solubility, dimensional change, and radiopacity were evaluated. Biocompatibility was measured using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. For microleakage test, single-rooted teeth were instrumented, and obturated with gutta-percha and one of the sealers (n = 10). After immersion in 1% methylene blue solution for 2 weeks, the specimens were split longitudinally. Then, the maximum length of staining was measured. Statistical analysis was performed by one-way analysis of variance followed by Tukey test (p = 0.05). RESULTS: Dia-Proseal showed the highest pH value among the tested sealers (p < 0.05). ADseal showed higher dimensional change compared to AHplus and Dia-Proseal (p < 0.05). The solubility values of AHplus and Dia-Proseal were similar, whereas ADseal had the lowest solubility value (p < 0.05). The flow values of sealer in increasing order were AHplus, DiaProseal, and ADseal (p < 0.05). The radiopacity of AHplus was higher than those of ADseal and Dia-Proseal (p < 0.05). The cell viability of the tested materials was statistically similar throughout the experimental period. There were no significant differences in microleakage values among the tested samples. CONCLUSIONS: The present study indicates that Dia-Proseal has acceptable physicochemical properties, biocompatibility, and sealing ability.

13.
Eur J Dent ; 10(3): 403-407, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27403062

RESUMEN

OBJECTIVES: The aim of this study was to evaluate tooth discoloration caused by contact with a novel injectable mineral trioxide aggregate (MTA)-based root canal sealer (Endoseal; Maruchi, Wonju, Korea) compared with a widely used resin-based root canal sealer (AHplus; Dentsply De Trey, Konstanz, Germany) and conventional MTA (ProRoot; Dentsply, Tulsa, OK, USA). MATERIALS AND METHODS: Forty standardized bovine tooth samples were instrumented and divided into three experimental groups and one control group (n = 10/group). Each material was inserted into the cavity, and all specimens were sealed with a self-adhesive resin. Based on CIE Lab system, brightness change (ΔL) and total color change (ΔE) of each specimen between baseline and 1, 2, 4, and 8 weeks were obtained. RESULTS: At all time points, Endoseal showed no significant difference in ΔL and ΔE compared to AHplus and control group (P > 0.05), whereas the ProRoot group showed significantly higher ΔL and ΔE values than the Endoseal group at 2, 4, and 8 weeks (P < 0.05). Therefore, Endoseal showed less discoloration than conventional MTA and a similar color change to AHplus. CONCLUSIONS: Within the limitations of this study, our data indicate that the MTA-based sealer produces a similar amount of tooth discoloration as AHplus which is considered to be acceptable.

14.
J Appl Oral Sci ; 24(1): 76-84, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27008260

RESUMEN

OBJECTIVE: The purpose of this study was to investigate the biological effects of epicatechin (ECN), a crosslinking agent, on human dental pulp cells (hDPCs) cultured in collagen scaffolds. MATERIAL AND METHOD: To evaluate the effects of ECN on the proliferation of hDPCs, cell counting was performed using optical and fluorescent microscopy. Measurements of alkaline phosphatase (ALP) activity, alizarin red staining, and real-time polymerase chain reactions were performed to assess odontogenic differentiation. The compressive strength and setting time of collagen scaffolds containing ECN were measured. Differential scanning calorimetry was performed to analyze the thermal behavior of collagen in the presence of ECN. RESULTS: Epicatechin increased ALP activity, mineralized nodule formation, and the mRNA expression of dentin sialophosphoprotein (DSPP), a specific odontogenic-related marker. Furthermore, ECN upregulated the expression of DSPP in hDPCs cultured in collagen scaffolds. Epicatechin activated the extracellular signal-regulated kinase (ERK) and the treatment with an ERK inhibitor (U0126) blocked the expression of DSPP. The compressive strength was increased and the setting time was shortened in a dose-dependent manner. The number of cells cultured in the ECN-treated collagen scaffolds was significantly increased compared to the cells in the untreated control group. CONCLUSIONS: Our results revealed that ECN promoted the proliferation and differentiation of hDPCs. Furthermore, the differentiation was regulated by the ERK signaling pathway. Changes in mechanical properties are related to cell fate, including proliferation and differentiation. Therefore, our study suggests the ECN treatment might be desirable for dentin-pulp complex regeneration.


Asunto(s)
Catequina/farmacología , Colágeno/farmacología , Reactivos de Enlaces Cruzados/farmacología , Pulpa Dental/citología , Pulpa Dental/efectos de los fármacos , Andamios del Tejido/química , Fosfatasa Alcalina/análisis , Análisis de Varianza , Western Blotting , Rastreo Diferencial de Calorimetría , Diferenciación Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Quinasas MAP Reguladas por Señal Extracelular/análisis , Expresión Génica , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa , Reproducibilidad de los Resultados , Factores de Tiempo
15.
J. appl. oral sci ; 24(1): 76-84, Jan.-Feb. 2016. graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-777354

RESUMEN

ABSTRACT Objective The purpose of this study was to investigate the biological effects of epicatechin (ECN), a crosslinking agent, on human dental pulp cells (hDPCs) cultured in collagen scaffolds. Material and Method To evaluate the effects of ECN on the proliferation of hDPCs, cell counting was performed using optical and fluorescent microscopy. Measurements of alkaline phosphatase (ALP) activity, alizarin red staining, and real-time polymerase chain reactions were performed to assess odontogenic differentiation. The compressive strength and setting time of collagen scaffolds containing ECN were measured. Differential scanning calorimetry was performed to analyze the thermal behavior of collagen in the presence of ECN. Results Epicatechin increased ALP activity, mineralized nodule formation, and the mRNA expression of dentin sialophosphoprotein (DSPP), a specific odontogenic-related marker. Furthermore, ECN upregulated the expression of DSPP in hDPCs cultured in collagen scaffolds. Epicatechin activated the extracellular signal-regulated kinase (ERK) and the treatment with an ERK inhibitor (U0126) blocked the expression of DSPP. The compressive strength was increased and the setting time was shortened in a dose-dependent manner. The number of cells cultured in the ECN-treated collagen scaffolds was significantly increased compared to the cells in the untreated control group. Conclusions Our results revealed that ECN promoted the proliferation and differentiation of hDPCs. Furthermore, the differentiation was regulated by the ERK signaling pathway. Changes in mechanical properties are related to cell fate, including proliferation and differentiation. Therefore, our study suggests the ECN treatment might be desirable for dentin-pulp complex regeneration.


Asunto(s)
Humanos , Catequina/farmacología , Colágeno/farmacología , Reactivos de Enlaces Cruzados/farmacología , Pulpa Dental/citología , Pulpa Dental/efectos de los fármacos , Andamios del Tejido/química , Factores de Tiempo , Rastreo Diferencial de Calorimetría , Expresión Génica , Diferenciación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Western Blotting , Reproducibilidad de los Resultados , Análisis de Varianza , Quinasas MAP Reguladas por Señal Extracelular/análisis , Proliferación Celular/efectos de los fármacos , Fosfatasa Alcalina/análisis , Reacción en Cadena en Tiempo Real de la Polimerasa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...