Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Pediatr Res ; 2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38007518

RESUMEN

BACKGROUND: The relationship of apolipoprotein-E4 (APOE4) to mortality and cognition after severe malaria in children is unknown. METHODS: APOE genotyping was performed in children with cerebral malaria (CM, n = 261), severe malarial anemia (SMA, n = 224) and community children (CC, n = 213). Cognition was assessed over 2-year follow-up. RESULTS: A greater proportion of children with CM or SMA than CC had APOE4 (n = 162, 31.0%; n = 142, 31.7%; n = 103, 24.2%, respectively, p = 0.02), but no difference was seen in APOE3 (n = 310, 59.4%; n = 267, 59.6%; n = 282, 66.2%, respectively, p = 0.06), or APOE2 (n = 50, 9.6%; n = 39, 8.7%; and n = 41, 9.6%, respectively, p = 0.87). APOE4 was associated with increased mortality in CM (odds ratio, 2.28; 95% CI, 1.01, 5.11). However, APOE4 was associated with better long-term cognition (ß, 0.55; 95% CI, 0.04, 1.07, p = 0.04) and attention (ß 0.78; 95% CI, 0.26, 1.30, p = 0.004) in children with CM < 5 years old, but worse attention (ß, -0.90; 95% CI, -1.69, -0.10, p = 0.03) in children with CM ≥ 5 years old. Among children with CM, risk of post-discharge malaria was increased with APOE4 and decreased with APOE3. CONCLUSIONS: APOE4 is associated with higher risk of CM or SMA and mortality in children with CM, but better long-term cognition in CM survivors <5 years of age.

2.
Malar J ; 20(1): 380, 2021 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-34563189

RESUMEN

BACKGROUND: Globally, there are over 200 million cases of malaria annually and over 400,000 deaths. Early and accurate detection of low-density parasitaemia and asymptomatic individuals is key to achieving the World Health Organization (WHO) 2030 sustainable development goals of reducing malaria-related deaths by 90% and eradication in 35 countries. Current rapid diagnostic tests are neither sensitive nor specific enough to detect the low parasite concentrations in the blood of asymptomatic individuals. METHODS: Here, an imaging-based sensing technique, particle diffusometry (PD), is combined with loop mediated isothermal amplification (LAMP) on a smartphone-enabled device to detect low levels of parasitaemia often associated with asymptomatic malaria. After amplification, PD quantifies the Brownian motion of fluorescent nanoparticles in the solution during a 30 s video taken on the phone. The resulting diffusion coefficient is used to detect the presence of Plasmodium DNA amplicons. The coefficients of known negative samples are compared to positive samples using a one-way ANOVA post-hoc Dunnett's test for confirmation of amplification. RESULTS: As few as 3 parasite/µL of blood was detectable in 45 min without DNA extraction. Plasmodium falciparum parasites were detected from asymptomatic individuals' whole blood samples with 89% sensitivity and 100% specificity when compared to quantitative polymerase chain reaction (qPCR). CONCLUSIONS: PD-LAMP is of value for the detection of low density parasitaemia especially in areas where trained personnel may be scarce. The demonstration of this smartphone biosensor paired with the sensitivity of LAMP provides a proof of concept to achieve widespread asymptomatic malaria testing at the point of care.


Asunto(s)
Enfermedades Asintomáticas/epidemiología , Pruebas Diagnósticas de Rutina/métodos , Malaria Falciparum/diagnóstico , Malaria Vivax/diagnóstico , Parasitemia/diagnóstico , Sistemas de Atención de Punto/normas , Teléfono Inteligente/estadística & datos numéricos , Niño , Preescolar , Humanos , Lactante , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Plasmodium falciparum/aislamiento & purificación , Plasmodium vivax/aislamiento & purificación , Uganda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...