Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Chromatogr A ; 1730: 465121, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38959659

RESUMEN

Mechanistic models are powerful tools for chromatographic process development and optimization. However, hydrophobic interaction chromatography (HIC) mechanistic models lack an effective and logical parameter estimation method, especially for multi-component system. In this study, a parameter-by-parameter method for multi-component system (called as mPbP-HIC) was derived based on the retention mechanism to estimate the six parameters of the Mollerup isotherm for HIC. The linear parameters (ks,i and keq,i) and nonlinear parameters (ni and qmax,i) of the isotherm can be estimated by the linear regression (LR) and the linear approximation (LA) steps, respectively. The remaining two parameters (kp,i and kkin,i) are obtained by the inverse method (IM). The proposed method was verified with a two-component model system. The results showed that the model could accurately predict the protein elution at a loading of 10 g/L. However, the elution curve fitting was unsatisfactory for high loadings (12 g/L and 14 g/L), which is mainly attributed to the demanding experimental conditions of the LA step and the potential large estimation error of the parameter qmax. Therefore, the inverse method was introduced to further calibrate the parameter qmax, thereby reducing the estimation error and improving the curve fitting. Moreover, the simplified linear approximation (SLA) was proposed by reasonable assumption, which provides the initial guess of qmax without solving any complex matrix and avoids the problem of matrix unsolvable. In the improved mPbP-HIC method, qmax would be initialized by the SLA and finally determined by the inverse method, and this strategy was named as SLA+IM. The experimental validation showed that the improved mPbP-HIC method has a better curve fitting, and the use of SLA+IM reduces the error accumulation effect. In process optimization, the parameters estimated by the improved mPbP-HIC method provided the model with excellent predictive ability and reasonable extrapolation. In conclusion, the SLA+IM strategy makes the improved mPbP-HIC method more rational and can be easily applied to the practical separation of protein mixture, which would accelerate the process development for HIC in downstream of biopharmaceuticals.


Asunto(s)
Interacciones Hidrofóbicas e Hidrofílicas , Cromatografía Liquida/métodos , Modelos Lineales , Proteínas/aislamiento & purificación , Proteínas/química , Proteínas/análisis , Modelos Químicos
2.
J Chromatogr A ; 1731: 465156, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39047442

RESUMEN

The single-component Mollerup model, with over 40 direct applications and 442 citations, is the most widely used activity model for chromatographic mechanistic modeling. Many researchers have extended this formula to multi-component systems by directly adding subscripts, a modification deemed thermodynamically inconsistent (referred to as the reference model). In this work, we rederived the asymmetric activity model for multi-component systems, using the van der Waals equation of state, and termed it the multi-component Mollerup model. In contrast to the reference model, our proposed model accounts for the contributions of all components to the activity. Three numerical experiments were performed to investigate the impact of the three different activity models on the chromatographic modeling. The results indicate that our proposed model represents a thermodynamically consistent generalization of the single-component Mollerup model to multi-component systems. This communication advocates adopting of the multi-component Mollerup model for activity modeling in multi-component chromatographic separation to enhance thermodynamic consistency.


Asunto(s)
Termodinámica , Modelos Químicos , Cromatografía/métodos , Modelos Teóricos
3.
Biotechnol J ; 19(3): e2300687, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38479994

RESUMEN

Developing an accurate and reliable model for chromatographic separation that meets regulatory requirements and ensures consistency in model development remains challenging. In order to address this challenge, a standardized approach was proposed in this study with ion-exchange chromatography (IEC). The approach includes the following steps: liquid flow identification, system and column-specific parameters determination and validation, multi-component system identification, protein amount validation, steric mass action parameters determination and evaluation, and validation of the calibrated model's generalization ability. The parameter-by-parameter (PbP) calibration method and the consideration of extra-column effects were integrated to enhance the accuracy of the developed models. The experiments designed for implementing the PbP method (five gradient experiments for model calibration and one stepwise experiment for model validation) not only streamline the experimental workload but also ensure the extrapolation abilities of the model. The effectiveness of the standardized approach is successfully validated through an application about the IEC separation of industrial antibody variants, and satisfactory results were observed with R2 ≈ 0.9 for the majority of calibration and validation experiments. The standardized approach proposed in this work contributes significantly to improve the accuracy and reliability of the developed IEC models. Models developed using this standardized approach are ready to be applied to a broader range of industrial separation systems, and are likely find further applications in model-assisted decision-making of process development.


Asunto(s)
Proteínas , Reproducibilidad de los Resultados , Cromatografía por Intercambio Iónico/métodos , Adsorción , Calibración
4.
Biotechnol Bioeng ; 121(6): 1876-1888, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38494789

RESUMEN

Regulatory authorities recommend using residence time distribution (RTD) to address material traceability in continuous manufacturing. Continuous virus filtration is an essential but poorly understood step in biologics manufacturing in respect to fluid dynamics and scale-up. Here we describe a model that considers nonideal mixing and film resistance for RTD prediction in continuous virus filtration, and its experimental validation using the inert tracer NaNO3. The model was successfully calibrated through pulse injection experiments, yielding good agreement between model prediction and experiment ( R 2 > ${R}^{2}\gt $ 0.90). The model enabled the prediction of RTD with variations-for example, in injection volumes, flow rates, tracer concentrations, and filter surface areas-and was validated using stepwise experiments and combined stepwise and pulse injection experiments. All validation experiments achieved R 2 > ${R}^{2}\gt $ 0.97. Notably, if the process includes a porous material-such as a porous chromatography material, ultrafilter, or virus filter-it must be considered whether the molecule size affects the RTD, as tracers with different sizes may penetrate the pore space differently. Calibration of the model with NaNO3 enabled extrapolation to RTD of recombinant antibodies, which will promote significant savings in antibody consumption. This RTD model is ready for further application in end-to-end integrated continuous downstream processes, such as addressing material traceability during continuous virus filtration processes.


Asunto(s)
Filtración , Filtración/métodos , Virus/aislamiento & purificación
5.
Biotechnol Bioeng ; 121(5): 1702-1715, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38230585

RESUMEN

Digital twin (DT) is a virtual and digital representation of physical objects or processes. In this paper, this concept is applied to dynamic control of the collection window in the ion exchange chromatography (IEC) toward sample variations. A possible structure of a feedforward model-based control DT system was proposed. Initially, a precise IEC mechanistic model was established through experiments, model fitting, and validation. The average root mean square error (RMSE) of fitting and validation was 8.1% and 7.4%, respectively. Then a model-based gradient optimization was performed, resulting in a 70.0% yield with a remarkable 11.2% increase. Subsequently, the DT was established by systematically integrating the model, chromatography system, online high-performance liquid chromatography, and a server computer. The DT was validated under varying load conditions. The results demonstrated that the DT could offer an accurate control with acidic variants proportion and yield difference of less than 2% compared to the offline analysis. The embedding mechanistic model also showed a positive predictive performance with an average RMSE of 11.7% during the DT test under >10% sample variation. Practical scenario tests indicated that tightening the control target could further enhance the DT robustness, achieving over 98% success rate with an average yield of 72.7%. The results demonstrated that the constructed DT could accurately mimic real-world situations and perform an automated and flexible pooling in IEC. Additionally, a detailed methodology for applying DT was summarized.


Asunto(s)
Anticuerpos Monoclonales , Cromatografía Líquida de Alta Presión/métodos , Anticuerpos Monoclonales/química , Cromatografía por Intercambio Iónico/métodos
6.
J Chromatogr A ; 1716: 464638, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38219627

RESUMEN

Hydrophobic interaction chromatography (HIC) is used as a critical polishing step in the downstream processing of biopharmaceuticals. Normally the process development of HIC is a cumbersome and time-consuming task, and the mechanical models can provide a powerful tool to characterize the process, assist process design and accelerate process development. However, the current estimation of model parameters relies on the inverse method, which lacks an efficient and logical parameter estimation strategy. In this study, a parameter-by-parameter (PbP) method based on the theoretical derivation and simplifying assumptions was proposed to estimate the Mollerup isotherm parameters for HIC. The method involves three key steps: (1) linear regression (LR) to estimate the salt-protein interaction parameter and the equilibrium constant; (2) linear approximation (LA) to estimate the stoichiometric parameter and the maximum binding capacity; and (3) inverse method to estimate the protein-protein interaction parameter and the kinetic coefficient. The results indicated that the LR step should be used for dilution condition (loading factor below 5%), while the LA step should be conducted when the isotherm is in the transition or nonlinear regions. Six numerical experiments were conducted to implement the PbP method. The results demonstrated that the PbP method developed allows for the systematic estimation of HIC parameters one-by-one, effectively reducing the number of parameters required for inverse method estimation from six to two. This helps prevent non-identifiability of structural parameters. The feasibility of the PbP-HIC method was further validated by real-world experiments. Moreover, the PbP method enhances the mechanistic understanding of adsorption behavior of HIC and shows a promising application to other stoichiometric displacement model-derived isotherms.


Asunto(s)
Cromatografía , Cloruro de Sodio , Adsorción , Cromatografía/métodos , Interacciones Hidrofóbicas e Hidrofílicas , Cloruro de Sodio Dietético
7.
Bioresour Bioprocess ; 9(1): 44, 2022 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-38647856

RESUMEN

The cellulase cocktail of marine Aspergillus niger exhibited salt-tolerant and thermostable properties, which is of great potential in industrial application. In order to excavate the single tolerant cellulase components from complex cellulase cocktail, constitutive homologous expression was employed for direct obtainment of the endoglucanase (AnEGL). Enzymatic property study revealed that AnEGL exhibited a property of salt tolerance and a strong thermostability in high salinity environment. Significantly, its activity increased to 129% and the half-life at 65 °C increased to 27.7-fold with the presence of 4.5 M NaCl. Molecular dynamics simulation revealed that Na+ and Cl- could form salt bridges with charged residues, and then influenced the activity of loops and the stability of substrate binding pocket, which accounted for the salt tolerance and thermostability. Further, site-specific mutagenesis study proved that the residues Asp95 and Asp99 in the pocket were of great concern for the tolerant properties. The salt-tolerant and thermostable AnEGL was of great value in lignocellulosic utilization and the conjectural mechanisms were of referential significance for other tolerant enzymes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA