Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Parkinsons Dis ; 5(1): 125-30, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25425583

RESUMEN

BACKGROUND: Low-contrast vision is thought to be reduced in Parkinson's disease (PD). This may have a direct impact on quality of life such as driving, using tools, finding objects, and mobility in low-light condition. Low-contrast letter acuity testing has been successful in assessing low-contrast vision in multiple sclerosis. We report the use of a new iPad application to measure low-contrast acuity in patients with PD. OBJECTIVE: To evaluate low- and high-contrast letter acuity in PD patients and controls using a variable contrast acuity eye chart developed for the Apple iPad. METHODS: Thirty-two PD and 71 control subjects were studied. Subjects viewed the Variable Contrast Acuity Chart on an iPad with both eyes open at two distances (40 cm and 2 m) and at high contrast (black and white visual acuity) and 2.5% low contrast. Acuity scores for the two groups were compared. RESULTS: PD patients had significantly lower scores (indicating worse vision) for 2.5% low contrast at both distances and for high contrast at 2 m (p < 0.003) compared to controls. No significant difference was found between the two groups for high contrast at 40 cm (p = 0.12). CONCLUSIONS: Parkinson's disease patients have reduced low and high contrast acuity compared to controls. An iPad app, as used in this study, could serve as a quick screening tool to complement more formal testing of patients with PD and other neurologic disorders.


Asunto(s)
Sensibilidad de Contraste/fisiología , Enfermedad de Parkinson/complicaciones , Trastornos de la Percepción/etiología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Trastornos de la Percepción/diagnóstico , Estimulación Luminosa
2.
Parkinsonism Relat Disord ; 20(2): 226-9, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24269283

RESUMEN

BACKGROUND: The King-Devick (KD) test measures the speed of rapid number naming, and is postulated to require fast eye movements, attention, language, and possibly other aspects of cognitive functions. While used in multiple sports concussion studies, it has not been applied to the field of movement disorders. METHODS: Forty-five Parkinson's disease (PD), 23 essential tremor (ET), and 65 control subjects were studied. Subjects performed two trials of reading out loud single-digit numbers separated by varying spacing on three test cards that were of different formats. The sum time of the faster trial was designated the KD score and compared across the three groups. RESULTS: PD patients had higher (worse) KD scores, with longer reading times compared to ET and control subjects (66 s vs. 49 s vs. 52 s, p < 0.001, adjusting for age and gender). No significant difference was found between ET and control (Δ = -3 s, 95% CI: -10 to 4). CONCLUSIONS: This is the first study of the King-Devick Test in Parkinson's disease. PD patients were found to have a slower rapid number naming speed compared to controls. This test may be a simple and rapid bedside tool for quantifying correlates of visual and cognitive function in Parkinson's disease.


Asunto(s)
Trastornos del Conocimiento/diagnóstico , Pruebas Neuropsicológicas , Enfermedad de Parkinson/complicaciones , Anciano , Anciano de 80 o más Años , Trastornos del Conocimiento/etiología , Temblor Esencial/complicaciones , Temblor Esencial/diagnóstico , Femenino , Humanos , Masculino , Enfermedad de Parkinson/diagnóstico , Enfermedad de Parkinson/fisiopatología , Movimientos Sacádicos/fisiología
4.
Brain ; 131(Pt 5): 1373-80, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18400841

RESUMEN

Overactivity of subthalamic nucleus (STN) neurons is a consistent feature of Parkinson's disease (PD) and is a target of therapy for this disorder. However, the relationship of STN firing rate to regional brain function is not known. We scanned 17 PD patients with (18)F-fluorodeoxyglucose (FDG) PET to measure resting glucose metabolism before the implantation of STN deep brain stimulation electrodes. Spontaneous STN firing rates were recorded during surgery and correlated with preoperative regional glucose metabolism on a voxel-by-voxel basis. We also examined the relationship between firing rate and the activity of metabolic brain networks associated with the motor and cognitive manifestations of the disease. Mean firing rates were 47.2 +/- 6.1 and 48.7 +/- 8.5 Hz for the left and right hemispheres, respectively. These measures correlated (P < 0.007) with glucose metabolism in the putamen and globus pallidus, which receive projections from this structure. Significant correlations (P < 0.0005) were also evident in the primary motor (BA4) and dorsolateral prefrontal (BA46/10) cortical areas. The activity of both the motor (P < 0.0001) and the cognitive (P < 0.006) PD-related metabolic networks was elevated in these patients. STN firing rates correlated with the activity of the former (P < 0.007) but not the latter network (P = 0.39). The findings suggest that the functional pathways associated with motor disability in PD are linked to the STN firing rate. These pathways are likely to mediate the clinical benefit that is seen following targeted STN interventions for this disease.


Asunto(s)
Enfermedad de Parkinson/metabolismo , Núcleo Subtalámico/fisiopatología , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Mapeo Encefálico/métodos , Estimulación Encefálica Profunda/métodos , Femenino , Glucosa/metabolismo , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Vías Nerviosas/fisiopatología , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/fisiopatología , Enfermedad de Parkinson/terapia , Tomografía de Emisión de Positrones , Núcleo Subtalámico/diagnóstico por imagen
5.
PDA J Pharm Sci Technol ; 58(2): 106-15, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15113076

RESUMEN

This study examined the feasibility of applying frequency-modulated spectroscopy (FMS) to test vacuum seal integrity of lyophilized protein pharmaceuticals in glass vials. A lyophilized recombinant monoclonal antibody was used as an example to demonstrate that FMS is a non-destructive method that could accurately and quickly determine vial vacuum integrity within a pressure range of 0.04 to 0.5 atm. The coefficient of determination (R2) of a bench-top instrument was found to be >0.99. Only seconds were required to analyze each sample. The instrument sensitivity and specificity were 0.95 and >0.99, respectively, based on analysis of approximately 40,000 samples. Because of low energy input by the instrument, no adverse effect on the protein quality was found immediately after up to 1 h of continuous laser exposure. The laser-exposed samples had comparable stability to non-exposed control vials after 12 weeks of storage at 40 degrees C.


Asunto(s)
Embalaje de Medicamentos/normas , Anticuerpos Monoclonales/química , Embalaje de Medicamentos/métodos , Estabilidad de Medicamentos , Almacenaje de Medicamentos , Liofilización , Sensibilidad y Especificidad , Espectroscopía Infrarroja por Transformada de Fourier , Vacio
6.
PDA J Pharm Sci Technol ; 56(4): 196-205, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12181804

RESUMEN

This study examined the application of near-infrared (NIR) spectroscopy to analyze residual moisture in lyophilized protein pharmaceuticals sealed in glass vials. We demonstrated that NIR was able to determine residual moisture in five marketed and clinical products with the same precision as Karl Fischer titration. We further investigated how changes in product configuration and protein formulation affected NIR measurement accuracy using a lyophilized monoclonal antibody rhuMAb E25 containing 1% to 5% residual moisture. The results indicated that the lyophilized cake porosity and dimensions had no effect on NIR measurement when the cake height and diameter exceeded the NIR penetration depth. In addition, changing the buffer and surfactant concentrations in the formulation did not affect moisture determination by NIR. However, doubling or halving the concentration of a disaccharide, which was used as a lyoprotectant, caused significant deviation between the NIR and Karl Fischer data because the NIR absorbance of the disaccharide overlapped with the moisture signal. Furthermore, complete removal of the disaccharide resulted in alteration of the protein NIR spectra, suggesting that NIR may be used to evaluate solid-state protein structure. The disaccharide concentration must be kept constant in this formulation to obtain accurate moisture results by NIR.


Asunto(s)
Liofilización , Proteínas/análisis , Agua/análisis , Calibración , Espectroscopía Infrarroja Corta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...