Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Org Chem ; 89(8): 5560-5572, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38564232

RESUMEN

A simple, efficient, and practical method for the synthesis of S-quinolyl xanthates was developed via Ts2O-promoted deoxygenative C-H dithiocarbonation of quinoline N-oxides with various potassium O-alkyl xanthates. The reaction performed well under transition-metal-free, base-free, and room-temperature conditions with wide substrate tolerance. Employing potassium O-tert-butyl xanthate (tBuOCS2K) as a nucleophile, some valuable quinoline-2-thiones were unexpectedly obtained in a one-pot reaction without any additional base.

2.
Molecules ; 29(5)2024 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-38474508

RESUMEN

The incorporation of amide groups into biologically active molecules has been proven to be an efficient strategy for drug design and discovery. In this study, we present a simple and practical method for the synthesis of amide-containing quinazolin-4(3H)-ones under transition-metal-free conditions. This is achieved through a carbamoyl-radical-triggered cascade cyclization of N3-alkenyl-tethered quinazolinones. Notably, the carbamoyl radical is generated in situ from the oxidative decarboxylative process of oxamic acids in the presence of (NH4)2S2O8.

3.
Global Health ; 19(1): 77, 2023 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-37864219

RESUMEN

BACKGROUND: This study aims to analyze the impact of Framework of Convention of Tobacco Control (FCTC) on regulatory contents of trade agreements from 2001 to 2019. METHODS: A search of trade agreements from'WTO Regional Free Trade Agreement Database' using keywords including "tobacco", "cigarette", "smoking" and "FCTC" from May to August 2020 resulted in a total sample of 268 trade agreements, from which 69 trade agreements were coded and analyzed. Provisions in trade agreements, identified via the aforementioned keywords, were categorized into 6 trade measures. The word counts of the provisions containing; FCTC; were calculated. Chi-square tests were applied to analyze the differences of regulatory patterns between different time frames. The import and export values (USD) of tobacco products under trade agreements containing the term "FCTC" were further collected from the "International Trade Statistics 2001-2020" for understanding the impact of the provision on the trade flow. RESULTS: Among 69 agreements, the percentage of trade agreements containing keyword as "FCTC" increased significantly from 0% to 2011 to 12% after 2011. A significant decrease of using trade measures as "the exclusion list" was found after 2011 (from 10% to 0). The word counts of provisions containing; FCTC; increased from 24 words in 2011 to 164 words in 2018, and the content of the provisions became more concrete over time. There are six trade agreements containing "FCTC", and all these 6 agreements were ratified by European Union (EU). Despite EU ratified trade agreements with "FCTC", the import and export values of tobacco products between EU and the other party countries increased with time. But the gap of average trade values between trade agreements with and without "FCTC" being widened with time. CONCLUSIONS: As a first study evaluated the impact of FCTC on regulatory contents of trade agreements, our study results showed that after countries signed trade agreements containing keyword FCTC, the regulatory contents changed significantly. Further studies are recommended to understand the reason and criteria for incorporating FCTC provisions into trade agreements, especially in the EU.


Asunto(s)
Industria del Tabaco , Productos de Tabaco , Humanos , Control del Tabaco , Comercio , Prevención del Hábito de Fumar , Internacionalidad , Políticas , Organización Mundial de la Salud
4.
Anal Chim Acta ; 1274: 341531, 2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37455073

RESUMEN

Variants of the severe acute respiratory syndrome coronavirus (SARS-CoV-2) have evolved such that it may be challenging for diagnosis and clinical treatment of the pandemic coronavirus disease-19 (COVID-19). Compared with developed SARS-CoV-2 diagnostic tools recently, aptamers may exhibit some advantages, including high specificity/affinity, longer shelf life (vs. antibodies), and could be easily prepared. Herein an integrated microfluidic system was developed to automatically carry out one novel screening process based on the systematic evolution of ligands by exponential enrichment (SELEX) for screening aptamers specific with SARS-CoV-2. The new screening process started with five rounds of positive selection (with the S1 protein of SARS-CoV-2). In addition, including non-target viruses (influenza A and B), human respiratory tract-related cancer cells (adenocarcinoma human alveolar basal epithelial cells and dysplastic oral keratinocytes), and upper respiratory tract-related infectious bacteria (including methicillin-resistant Staphylococcus aureus, Pseudomonas aeruginosa, Acinetobacter baumannii, and Klebsiella pneumoniae), and human saliva were involved to increase the specificity of the screened aptamer during the negative selection. Totally, all 10 rounds could be completed within 20 h. The dissociation constant of the selected aptamer was determined to be 63.0 nM with S1 protein. Limits of detection for Wuhan and Omicron clinical strains were found to be satisfactory for clinical applications (i.e. 4.80 × 101 and 1.95 × 102 copies/mL, respectively). Moreover, the developed aptamer was verified to be capable of capturing inactivated SARS-CoV-2 viruses, eight SARS-CoV-2 pseudo-viruses, and clinical isolates of SARS-CoV-2 viruses. For high-variable emerging viruses, this developed integrated microfluidic system can be used to rapidly select highly-specific aptamers based on the novel SELEX methods to deal with infectious diseases in the future.


Asunto(s)
Aptámeros de Nucleótidos , COVID-19 , Staphylococcus aureus Resistente a Meticilina , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Microfluídica , Prueba de COVID-19 , Staphylococcus aureus Resistente a Meticilina/metabolismo , Aptámeros de Nucleótidos/farmacología , Aptámeros de Nucleótidos/metabolismo , Técnica SELEX de Producción de Aptámeros/métodos
5.
J Med Internet Res ; 25: e44538, 2023 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-37342081

RESUMEN

BACKGROUND: To ensure the timely diagnosis of emerging infectious diseases, high-tech molecular biotechnology is often used to detect pathogens and has gradually become the gold standard for virological testing. However, beginners and students are often unable to practice their skills due to the higher costs associated with high-level virological testing, the increasing complexity of the equipment, and the limited number of specimens from patients. Therefore, a new training program is necessary to increase training and reduce the risk of test failure. OBJECTIVE: The aim of the study is to (1) develop and implement a virtual reality (VR) software for simulated and interactive high-level virological testing that can be applied in clinical practice and skills building or training settings and (2) evaluate the VR simulation's effectiveness on reaction, learning, and behavior of the students (trainees). METHODS: Viral nucleic acid tests on a BD MAX instrument were selected for our VR project because it is a high-tech automatic detection system. There was cooperation between teachers of medical technology and biomedical engineering. Medical technology teachers were responsible for designing the lesson plan, and the biomedical engineering personnel developed the VR software. We designed a novel VR teaching software to simulate cognitive learning via various procedure scenarios and interactive models. The VR software contains 2D VR "cognitive test and learning" lessons and 3D VR "practical skills training" lessons. We evaluated students' learning effectiveness pre- and posttraining and then recorded their behavior patterns when answering questions, performing repeated exercises, and engaging in clinical practice. RESULTS: The results showed that the use of the VR software met participants' needs and enhanced their interest in learning. The average posttraining scores of participants exposed to 2D and 3D VR training were significantly higher than participants who were exposed solely to traditional demonstration teaching (P<.001). Behavioral assessments of students pre- and posttraining showed that students exposed to VR-based training to acquire relevant knowledge of advanced virological testing exhibited significantly improved knowledge of specific items posttraining (P<.01). A higher participant score led to fewer attempts when responding to each item in a matching task. Thus, VR can enhance students' understanding of difficult topics. CONCLUSIONS: The VR program designed for this study can reduce the costs associated with virological testing training, thus, increasing their accessibility for students and beginners. It can also reduce the risk of viral infections particularly during disease outbreaks (eg, the COVID-19 pandemic) and also enhance students' learning motivation to strengthen their practical skills.


Asunto(s)
COVID-19 , Realidad Virtual , Humanos , Pandemias , Programas Informáticos , Aprendizaje
7.
Radiat Oncol ; 12(1): 55, 2017 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-28320428

RESUMEN

BACKGROUND: To improve local control rate in patients with breast cancer receiving adjuvant radiotherapy after breast conservative surgery, additional boost dose to the tumor bed could be delivered simultaneously via the simultaneous integrated boost (SIB) modulated technique. However, the position of tumor bed kept changing during the treatment course as the treatment position was aligned to bony anatomy. This study aimed to analyze the positional uncertainties between bony anatomy and tumor bed, and a topology-based approach was derived to stratify patients with high variation in tumor bed localization. METHODS: Sixty patients with early-stage breast cancer or ductal carcinoma in situ were enrolled. All received adjuvant whole breast radiotherapy with or without local boost via SIB technique. The delineation of tumor bed was defined by incorporating the anatomy of seroma, adjacent surgical clips, and any architectural distortion on computed tomography simulation. A total of 1740 on-board images were retrospectively analyzed. Positional uncertainty of tumor bed was assessed by four components: namely systematic error (SE), and random error (RE), through anterior-posterior (AP), cranial-caudal (CC), left-right (LR) directions and couch rotation (CR). Age, tumor location, and body-mass factors including volume of breast, volume of tumor bed, breast thickness, and body mass index (BMI) were analyzed for their predictive role. The appropriate margin to accommodate the positional uncertainty of the boost volume was assessed, and the new plans with this margin for the tumor bed was designed as the high risk planning target volume (PTV-H) were created retrospectively to evaluate the impact on organs at risk. RESULTS: In univariate analysis, a larger breast thickness, larger breast volume, higher BMI, and different tumor locations correlated with a greater positional uncertainty of tumor bed. However, BMI was the only factor associated with displacements of surgical clips in the multivariate analysis and patients with higher BMI were stratified as high variation group. When image guidance was aligned to bony structures, the SE and RE of clip displacement were consistently larger in the high variation group. The corresponding PTV-H margins for the high- and low-variation groups were 7, 10, 10 mm and 4, 9, 6 mm in AP, CC, LR directions, respectively. The heart dose between the two plans was not significantly different, whereas the dosimetric parameters for the ipsilateral lung were generally higher in the new plans. CONCLUSIONS: In patients with breast cancer receiving adjuvant radiotherapy, a higher BMI is associated with a greater positional uncertainty of the boost tumor volume. More generous margin should be considered and it can be safely applied through proper design of beam arrangement with advanced treatment techniques.


Asunto(s)
Neoplasias de la Mama/radioterapia , Carcinoma Intraductal no Infiltrante/radioterapia , Radiometría , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia/métodos , Adulto , Anciano , Índice de Masa Corporal , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Instrumentos Quirúrgicos , Incertidumbre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...