Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Korean J Ophthalmol ; 30(5): 382-389, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27729759

RESUMEN

PURPOSE: To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). METHODS: Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. RESULTS: The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. CONCLUSIONS: The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance.


Asunto(s)
Afaquia Poscatarata/terapia , Extracción de Catarata , Lentes Intraoculares Fáquicas , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Afaquia Poscatarata/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis
2.
J Refract Surg ; 32(8): 526-32, 2016 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27505313

RESUMEN

PURPOSE: To evaluate functional results and reading performance using the Salzburg Reading Desk after implantation of a sector-shaped near-embedded, rotational asymmetrical multifocal intraocular lens (IOL) and a multifocal toric IOL with a +3.00 diopter (D) near addition. METHODS: In a prospective study, the LentisMplus and Mplus toric IOLs (Oculentis GmbH, Berlin, Germany) were implanted in 34 eyes of 18 patients at the University Eye Hospital of Heidelberg. Uncorrected and corrected distance visual acuity (UDVA, CDVA) and uncorrected and corrected near visual acuity (UNVA, CNVA) were evaluated using standardized visual acuity charts (ETDRS). The Salzburg Reading Desk was used to analyze unilateral and bilateral uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at a set (40 cm/80 cm) and subjective chosen near and intermediate distance. RESULTS: Postoperatively, the median UDVA was 0.08 logMAR (20/25 Snellen) and the median CDVA was 0.01 logMAR (20/20 Snellen). The median UNVA was 0.12 logMAR (20/25 Snellen) and the median CNVA was 0.03 logMAR (20/20 Snellen). The median uncorrected reading acuity measured with the Salzburg Reading Desk for near distance at 40 cm was 0.18 logMAR (20/32 Snellen). The subjectively preferred near distance was 39 cm and revealed similar visual acuity results. The best reading acuity for intermediate distance with a median of 0.22 logMAR (20/32 Snellen) was achieved at a median distance of 62 cm. CONCLUSIONS: Reading performance of the multifocal IOL corresponded for near standardized and individual distance, whereas reading function was better at the patient's preferred intermediate distance. [J Refract Surg. 2016;32(8):526-532.].


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Seudofaquia/fisiopatología , Lectura , Refracción Ocular/fisiología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Pruebas de Visión , Agudeza Visual/fisiología
3.
J Cataract Refract Surg ; 41(12): 2707-14, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26796451

RESUMEN

PURPOSE: To evaluate reading performance of a trifocal intra-ocular lens (IOL) at near and intermediate distances using the Salzburg Reading Desk. SETTING: International Vision Correction Research Centre and David J. Apple Laboratory, University Eye Clinic, Heidelberg, Germany. DESIGN: Prospective, nonrandomized clinical study. METHODS: Follow-up examinations at a minimum of 3 months postoperatively included uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA)) intermediate as well as uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity. Uncorrected and distance-corrected reading acuity at 40 cm for near, 80 cm for intermediate distance, and at the patient's preferred near and intermediate distances were evaluated with the reading desk. RESULTS: In this study, 22 eyes of 11 patients having cataract surgery with implantation of the trifocal Finevision IOL were evaluated. Postoperative monocular Snellen median values were 20/21.44 (range 20/52.61 to 20/14.49) for UDVA, 20/20.47 (range 20/38.11 to 20/16.64) for UIVA, and 20/26.39 (range 20/43.76 to 20/18.24) for UNVA. Subjective intermediate distance at the binocular uncorrected examination on the reading desk was 64.2 cm (range 51.9 to 80.0) with a reading acuity of 0.10 logMAR (range 0.32 to 0.00). Subjective near distance at the uncorrected binocular reading desk examination was 36.5 cm (30.8 to 41.2) with a near reading acuity of 0.06 logMAR (range 0.23 to -0.01). The preferred distances differed significantly from the fixed ones of 40 and 80 cm. The preferred intermediate distance was almost consistent, with the intermediate addition of 1.75 D corresponding to 57.1 cm. CONCLUSION: The visual and reading function of the trifocal IOL was better at the patient's preferred near and intermediate distances. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Seudofaquia/fisiopatología , Lectura , Visión Binocular/fisiología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Refracción Ocular/fisiología , Agudeza Visual/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...