1.
Chemosphere ; 356: 141895, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38579947

RESUMEN

The over-exploitation of antibiotics in food and farming industries ruined the environmental and human health. Consequently, electrochemical sensors offer significant advantages in monitoring these compounds with high accuracy. Herein, MOF-derived hollow Co3S4@MoS2 (CS@MS) heterostructure has been prepared hydrothermally and applied to fabricate an electrochemical sensor to monitor nitrofuran class antibiotic drug. Various spectroscopic methodologies have been employed to elucidate the structural and morphological information. Our prepared electrocatalyst has better electrocatalytic performance than bare and other modified glassy carbon electrodes (GCE). Our CS@MS/GCE sensor exhibited a highly sensitive detection by offering a low limit of detection, good sensitivity, repeatability, reproducibility, and stability results. In addition, our sensor has shown a good selectivity towards the target analyte among other potential interferons. The practical reliability of the sensor was measured by analyzing various real-time environmental and biological samples and obtaining good recovery values. From the results, our fabricated CS@MS could be an active electrocatalyst material for an efficient electrochemical sensing application.


Asunto(s)
Cobalto , Técnicas Electroquímicas , Furazolidona , Estructuras Metalorgánicas , Molibdeno , Técnicas Electroquímicas/métodos , Furazolidona/análisis , Catálisis , Cobalto/química , Cobalto/análisis , Molibdeno/química , Estructuras Metalorgánicas/química , Electrodos , Disulfuros/química , Límite de Detección , Reproducibilidad de los Resultados , Antibacterianos/análisis
3.
BMC Urol ; 22(1): 56, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413871

RESUMEN

This study aimed to investigate clinical effectiveness of stone disintegration by using isolation coupling pad ("icPad") as coupling medium to reduce trapped air pockets during extracorporeal shock wave lithotripsy (ESWL). Patients underwent ESWL between Oct. 2017 and May 2018 were enrolled in this clinical observational study. An electromagnetic lithotripter (Dornier MedTech Europe GmbH Co., Germany) was used in this study. Patients were divided into icPad group P1, P2 and semi-gel group C by different coupling medium. The energy level and total number of shock wave (SW) for group P1 and C was set at level 2 and 3000 and group P2 at level 3 and 2500. The successful stone disintegration rate (SSDR) was determined to evaluate the treatment outcome. All patients were evaluated by KUB film and ultrasonography after 90 days. Complications during ESWL were recorded. A total of 300 patients satisfied the inclusion criteria. There were no significant differences in characteristics of patients and stone among three groups. The corresponding SSDRs for patients in group P1, P2 and C was 73.0%, 73.2% and 55.3%, respectively. The SSDR in group P1 was statistically higher than Group C. Comparing to semi-liquid gel, coupling medium using by icPad could achieve better treatment outcome of stone disintegration in ESWL.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Fatiga , Humanos , Cálculos Renales/terapia , Resultado del Tratamiento , Cálculos Ureterales/terapia
4.
BMC Urol ; 21(1): 79, 2021 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-33990213

RESUMEN

INTRODUCTION: Air pockets between the lithotripter head and body surface are almost inevitably generated when applying a handful of gel onto the contact portion of the treatment head and that on the patient's skin during coupling procedure. These air pockets can compromise the transmission of acoustic energy of shock wave and may significantly affect efficacy of stone disintegration. Comparing to conventional gel, this study aims to investigate efficacy of stone disintegration by using a proprietary isolation-coupling pad ("icPad") as the coupling medium to reduce trapped air pockets during ESWL procedure. METHOD: In this phantom study, Dornier lithotripter (Delta-2 RC, Dornier MedTech Europe GmbH Co., Germany) was used with a proprietary gel pads (icPad, Diameter = 150 mm, Thickness = 4 mm and 8 mm). The lithotripter was equipped with inline camera to observe the trapped air pockets between the contact surface of the lithotripter head. A testing and measuring device were used to observe experimental stone disintegration using icPad and semi-liquid gel. The conventional semi-liquid gel was used as control for result comparison. RESULTS: The stone disintegration rate of icPad 4 mm and 8 mm after 200 shocks of energy at level 2 were significantly higher than that of the semi-liquid gel (disintegration rate 92.3%, 85.0% vs. 45.5%, respectively, p < 0.001). The number of shocks for complete stone disintegration by icPad of 4 mm and 8 mm at the same energy level 2 were significantly lower than that of the semi-liquid gel (the number of shocks 242.0 ± 13.8, 248.7 ± 6.3 vs. 351.0 ± 54.6, respectively, p = 0.011). Furthermore, quantitative comparison of observed air pockets under Optical Coupling Control (OCC) system showed that the area of air pockets in semi-liquid group was significantly larger than that of the group using icPad (8 mm) and that of the group using icPad (8 mm) after sliding (332.7 ± 91.2 vs. 50.3 ± 31.9, 120.3 ± 21.5, respectively, p < 0.05). CONCLUSION: The advantages of icPad includes: (1) reduced the numbers of shock wave and increased stone disintegration rate due to icPad's superior efficacy; (2) significantly reduce trapped air pockets in ESWL coupling. Due to the study limitation, more data are needed to confirm our observations before human trials.


Asunto(s)
Geles , Litotricia/métodos , Aire , Humanos , Litotricia/instrumentación , Fantasmas de Imagen
5.
Chin J Physiol ; 57(1): 31-40, 2014 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-24621336

RESUMEN

M-3M3FBS (2,4,6-trimethyl-N-(meta-3-trifluoromethyl-phenyl)-benzenesulfonamide is a presumed phospholipase C activator which induced Ca²âº movement and apoptosis in different cell models. How- ever, the effect of m-3M3FBS on cytosolic free Ca²âº concentrations ([Ca²âº]i) and apoptosis in SCM1 human gastric cancer cells is unclear. This study explored whether m-3M3FBS elevated basal [Ca²âº]i levels in suspended cells by using fura-2 as a Ca²âº-sensitive fluorescent dye. M-3M3FBS at concentrations between 5-50 µM increased [Ca²âº]i in a concentration-dependent manner. The Ca²âº signal was reduced by half by removing extracellular Ca²âº. M-3M3FBS-induced Ca²âº influx was inhibited by nifedipine, econazole, SK&F96365, aristolochic acid, and GF109203X. In Ca²âº-free medium, 50 µM m-3M3FBS pretreatment inhibited the [Ca²âº]i rise induced by the endoplasmic reticulum Ca²âº pump inhibitor thapsigargin. Conversely, pretreatment with thapsigargin partly reduced m-3M3FBS-induced [Ca²âº]i rise. Suppression of inositol 1,4,5-trisphosphate production with U73122 did not change m-3M3FBS- induced [Ca²âº]i rise. At concentrations between 25 and 50 µM m-3M3FBS killed cells in a concentration- dependent manner. The cytotoxic effect of m-3M3FBS was not reversed by prechelating cytosolic Ca²âº with acetoxy-methyl ester of bis-(o-aminophenoxy)-ethane-N,N,N',N'-tetraacetic acid (BAPTA/AM). Annexin V/propidium iodide staining data suggest that m-3M3FBS induced apoptosis at 25 and 50 µM. M-3M3FBS also increased levels of superoxide. Together, in human gastric cancer cells, m-3M3FBS induced a [Ca²âº]i rise by inducing phospholipase C-independent Ca²âº release from the endoplasmic reticulum and Ca²âº entry via protein kinase C-sensitive store-operated Ca²âº channels. M-3M3FBS induced cell death that might involve apoptosis via reactive oxygen species production.