1.
J Appl Clin Med Phys ; 25(4): e14300, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38386967

RESUMEN

PURPOSE: The aim of this study was to characterize a second-generation wide-detector dual-layer spectral computed tomography (CT) system for material quantification accuracy, acquisition parameter and patient size dependencies, and tissue characterization capabilities. METHODS: A phantom with multiple tissue-mimicking and material-specific inserts was scanned with a dual-layer spectral detector CT using different tube voltages, collimation widths, radiation dose levels, and size configurations. Accuracy of iodine density maps and virtual monoenergetic images (MonoE) were investigated. Additionally, differences between conventional and MonoE 70 keV images were calculated to evaluate acquisition parameter and patient size dependencies. To demonstrate material quantification and differentiation, liver-mimicking inserts with adipose and iron were analyzed with a two-base decomposition utilizing MonoE 50 and 150 keV, and root mean square error (RMSE) for adipose and iron content was reported. RESULTS: Measured inserts exhibited quantitative accuracy across a wide range of MonoE levels. MonoE 70 keV images demonstrated reduced dependence compared to conventional images for phantom size (1 vs. 27 HU) and acquisition parameters, particularly tube voltage (4 vs. 37 HU). Iodine density quantification was successful with errors ranging from -0.58 to 0.44 mg/mL. Similarly, inserts with different amounts of adipose and iron were differentiated, and the small deviation in values within inserts corresponded to a RMSE of 3.49 ± 1.76% and 1.67 ± 0.84 mg/mL for adipose and iron content, respectively. CONCLUSION: The second-generation dual-layer CT enables acquisition of quantitatively accurate spectral data without compromises from differences in patient size and acquisition parameters.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Humanos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Obesidad , Hierro
2.
J Cardiovasc Magn Reson ; 26(1): 100995, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38219955

RESUMEN

Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs.

3.
Sci Rep ; 14(1): 53, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38167550

RESUMEN

The objective of this study is to define CT imaging derived phenotypes for patients with hepatic steatosis, a common metabolic liver condition, and determine its association with patient data from a medical biobank. There is a need to further characterize hepatic steatosis in lean patients, as its epidemiology may differ from that in overweight patients. A deep learning method determined the spleen-hepatic attenuation difference (SHAD) in Hounsfield Units (HU) on abdominal CT scans as a quantitative measure of hepatic steatosis. The patient cohort was stratified by BMI with a threshold of 25 kg/m2 and hepatic steatosis with threshold SHAD ≥ - 1 HU or liver mean attenuation ≤ 40 HU. Patient characteristics, diagnoses, and laboratory results representing metabolism and liver function were investigated. A phenome-wide association study (PheWAS) was performed for the statistical interaction between SHAD and the binary characteristic LEAN. The cohort contained 8914 patients-lean patients with (N = 278, 3.1%) and without (N = 1867, 20.9%) steatosis, and overweight patients with (N = 1863, 20.9%) and without (N = 4906, 55.0%) steatosis. Among all lean patients, those with steatosis had increased rates of cardiovascular disease (41.7 vs 27.8%), hypertension (86.7 vs 49.8%), and type 2 diabetes mellitus (29.1 vs 15.7%) (all p < 0.0001). Ten phenotypes were significant in the PheWAS, including chronic kidney disease, renal failure, and cardiovascular disease. Hepatic steatosis was found to be associated with cardiovascular, kidney, and metabolic conditions, separate from overweight BMI.


Asunto(s)
Enfermedades Cardiovasculares , Diabetes Mellitus Tipo 2 , Hígado Graso , Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedades Cardiovasculares/complicaciones , Sobrepeso/complicaciones , Sobrepeso/diagnóstico por imagen , Diabetes Mellitus Tipo 2/complicaciones , Hígado Graso/complicaciones , Tomografía Computarizada por Rayos X/métodos , Fenotipo , Enfermedad del Hígado Graso no Alcohólico/complicaciones
5.
Eur Radiol ; 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38114847

RESUMEN

OBJECTIVES: To compare cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) for the quantitative assessment of the left ventricular (LV) trabeculated layer in patients with suspected noncompaction cardiomyopathy (NCCM). MATERIALS AND METHODS: Subjects with LV excessive trabeculation who underwent both CMR and CCT imaging as part of the prospective international multicenter NONCOMPACT clinical study were included. For each subject, short-axis CCT and CMR slices were matched. Four quantitative metrics were estimated: 1D noncompacted-to-compacted ratio (NCC), trabecular-to-myocardial area ratio (TMA), trabecular-to-endocardial cavity area ratio (TCA), and trabecular-to-myocardial volume ratio (TMV). In 20 subjects, end-diastolic and mid-diastolic CCT images were compared for the quantification of the trabeculated layer. Relationships between the metrics were investigated using linear regression models and Bland-Altman analyses. RESULTS: Forty-eight subjects (49.9 ± 12.8 years; 28 female) were included in this study. NCC was moderately correlated (r = 0.62), TMA and TMV were strongly correlated (r = 0.78 and 0.78), and TCA had excellent correlation (r = 0.92) between CMR and CCT, with an underestimation bias from CCT of 0.3 units, and 5.1, 4.8, and 5.4 percent-points for the 4 metrics, respectively. TMA, TCA, and TMV had excellent correlations (r = 0.93, 0.96, 0.94) and low biases (- 3.8, 0.8, - 3.8 percent-points) between the end-diastolic and mid-diastolic CCT images. CONCLUSIONS: TMA, TCA, and TMV metrics of the LV trabeculated layer in patients with suspected NCCM demonstrated high concordance between CCT and CMR images. TMA and TCA were highly reproducible and demonstrated minimal differences between mid-diastolic and end-diastolic CCT images. CLINICAL RELEVANCE STATEMENT: The results indicate similarity of CCT to CMR for quantifying the LV trabeculated layer, and the small differences in quantification between end-diastole and mid-diastole demonstrate the potential for quantifying the LV trabeculated layer from clinically performed coronary CT angiograms. KEY POINTS: • Data on cardiac CT for quantifying the left ventricular trabeculated layer are limited. • Cardiac CT yielded highly reproducible metrics of the left ventricular trabeculated layer that correlated well with metrics defined by cardiac MR. • Cardiac CT appears to be equivalent to cardiac MR for the quantification of the left ventricular trabeculated layer.

6.
Eur J Radiol Open ; 11: 100538, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38028186

RESUMEN

Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol. Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner. Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p < 0.001). The median DLP with the PCD-CT was 182.0 mGy.cm and EID system was 262.60 mGy.cm (p < 0.001). The contrast to noise ratio (CNR) was superior on the PCD-CT system 59.2 compared to the EID-CT 53.3; (p < 0.001). Kappa-statistic showed that there was poor agreement between the readers over the image quality from the PCD and EID scanners (κ = 0.19; 95 % CI: 0.12 - 0.27; p < 0.001). Chi-square analysis revealed that 3 out of 5 readers showed a significant preference for images from the PCDCT (p ≤ 0.012). There was no significant difference in the preferences of two readers between EID-CT and PCD-CT images. Conclusion: The first clinical PCD-CT system allows a significant reduction in radiation exposure while maintaining image quality and image noise using a standardized non-contrast chest CT protocol.

7.
Radiol Cardiothorac Imaging ; 5(4): e230022, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37693194

RESUMEN

Purpose: To perform a living systematic review and meta-analysis of randomized controlled trials comparing the effectiveness of coronary CT angiography (CCTA) and standard of care (SOC) in the evaluation of acute chest pain (ACP). Materials and Methods: Multiple electronic databases were systematically searched, with the most recent search conducted on October 31, 2022. Studies were stratified into two groups according to the pretest probability for acute coronary syndrome (group 1 with predominantly low-to-intermediate risk vs group 2 with high risk). A meta-regression analysis was also conducted using participant risk, type of SOC used, and the use or nonuse of high-sensitivity troponins as independent variables. Results: The final analysis included 22 randomized controlled trials (9379 total participants; 4956 assigned to CCTA arms and 4423 to SOC arms). There was a 14% reduction in the length of stay and a 17% reduction in immediate costs for the CCTA arm compared with the SOC arm. In group 1, the length of stay was 17% shorter and costs were 21% lower using CCTA. There was no evidence of differences in referrals to invasive coronary angiography, myocardial infarction, mortality, rate of hospitalization, further stress testing, or readmissions between CCTA and SOC arms. There were more revascularizations (relative risk, 1.45) and medication changes (relative risk, 1.33) in participants with low-to-intermediate acute coronary syndrome risk and increased radiation exposure in high-risk participants (mean difference, 7.24 mSv) in the CCTA arm compared with the SOC arm. The meta-regression analysis found significant differences between CCTA and SOC arms for rate of hospitalization, further stress testing, and medication changes depending on the type of SOC (P < .05). Conclusion: The results support the use of CCTA as a safe, rapid, and less expensive in the short term strategy to exclude acute coronary syndrome in low- to intermediate-risk patients presenting with acute chest pain.Keywords: Acute Coronary Syndrome, Chest Pain, Emergency Department, Coronary Computed Tomography, Usual Care Supplemental material is available for this article. Published under a CC BY 4.0 license.

8.
Sci Rep ; 13(1): 14895, 2023 09 09.
Artículo en Inglés | MEDLINE | ID: mdl-37689744

RESUMEN

We evaluate stability of spectral results at different heart rates, acquisition modes, and cardiac phases in first-generation clinical dual-source photon-counting CT (PCCT). A cardiac motion simulator with a coronary stenosis mimicking a 50% eccentric calcium plaque was scanned at five different heart rates (0, 60-100 bpm) with the three available cardiac scan modes (high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, retrospectively ECG-gated spiral). Subsequently, full width half max (FWHM) of the stenosis, Dice score (DSC) for the stenosed region, and eccentricity of the non-stenosed region were calculated for virtual monoenergetic images (VMI) at 50, 70, and 150 keV and iodine density maps at both diastole and systole. FWHM averaged differences of - 0.20, - 0.28, and - 0.15 mm relative to static FWHM at VMI 150 keV across acquisition parameters for high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, and retrospectively ECG-gated spiral scans, respectively. Additionally, there was no effect of heart rate and acquisition mode on FWHM at diastole (p-values < 0.001). DSC demonstrated similarity among parameters with standard deviations of 0.08, 0.09, 0.11, and 0.08 for VMI 50, 70, and 150 keV, and iodine density maps, respectively, with insignificant differences at diastole (p-values < 0.01). Similarly, eccentricity illustrated small differences across heart rate and acquisition mode for each spectral result. Consistency of spectral results at different heart rates and acquisition modes for different cardiac phase demonstrates the added benefit of spectral results from PCCT to dual-source CT to further increase confidence in quantification and advance cardiovascular diagnostics.


Asunto(s)
Estenosis Coronaria , Yodo , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Corazón/diagnóstico por imagen , Constricción Patológica
9.
Acad Radiol ; 30(10): 2269-2279, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37210268

RESUMEN

RATIONALE AND OBJECTIVES: Finding comparison to relevant prior studies is a requisite component of the radiology workflow. The purpose of this study was to evaluate the impact of a deep learning tool simplifying this time-consuming task by automatically identifying and displaying the finding in relevant prior studies. MATERIALS AND METHODS: The algorithm pipeline used in this retrospective study, TimeLens (TL), is based on natural language processing and descriptor-based image-matching algorithms. The dataset used for testing comprised 3872 series of 246 radiology examinations from 75 patients (189 CTs, 95 MRIs). To ensure a comprehensive testing, five finding types frequently encountered in radiology practice were included: aortic aneurysm, intracranial aneurysm, kidney lesion, meningioma, and pulmonary nodule. After a standardized training session, nine radiologists from three university hospitals performed two reading sessions on a cloud-based evaluation platform resembling a standard RIS/PACS. The task was to measure the diameter of the finding-of-interest on two or more exams (a most recent and at least one prior exam): first without use of TL, and a second session at an interval of at least 21 days with the use of TL. All user actions were logged for each round, including time needed to measure the finding at all timepoints, number of mouse clicks, and mouse distance traveled. The effect of TL was evaluated in total, per finding type, per reader, per experience (resident vs. board-certified radiologist), and per modality. Mouse movement patterns were analyzed with heatmaps. To assess the effect of habituation to the cases, a third round of readings was performed without TL. RESULTS: Across scenarios, TL reduced the average time needed to assess a finding at all timepoints by 40.1% (107 vs. 65 seconds; p < 0.001). Largest accelerations were demonstrated for assessment of pulmonary nodules (-47.0%; p < 0.001). Less mouse clicks (-17.2%) were needed for finding evaluation with TL, and mouse distance traveled was reduced by 38.0%. Time needed to assess the findings increased from round 2 to round 3 (+27.6%; p < 0.001). Readers were able to measure a given finding in 94.4% of cases on the series initially proposed by TL as most relevant series for comparison. The heatmaps showed consistently simplified mouse movement patterns with TL. CONCLUSION: A deep learning tool significantly reduced both the amount of user interactions with the radiology image viewer and the time needed to assess findings of interest on cross-sectional imaging with relevant prior exams.


Asunto(s)
Aprendizaje Profundo , Humanos , Estudios Retrospectivos , Radiólogos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos
10.
PNAS Nexus ; 2(3): pgad026, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36909822

RESUMEN

In modern clinical decision-support algorithms, heterogeneity in image characteristics due to variations in imaging systems and protocols hinders the development of reproducible quantitative measures including for feature extraction pipelines. With the help of a reader study, we investigate the ability to provide consistent ground-truth targets by using patient-specific 3D-printed lung phantoms. PixelPrint was developed for 3D-printing lifelike computed tomography (CT) lung phantoms by directly translating clinical images into printer instructions that control density on a voxel-by-voxel basis. Data sets of three COVID-19 patients served as input for 3D-printing lung phantoms. Five radiologists rated patient and phantom images for imaging characteristics and diagnostic confidence in a blinded reader study. Effect sizes of evaluating phantom as opposed to patient images were assessed using linear mixed models. Finally, PixelPrint's production reproducibility was evaluated. Images of patients and phantoms had little variation in the estimated mean (0.03-0.29, using a 1-5 scale). When comparing phantom images to patient images, effect size analysis revealed that the difference was within one-third of the inter- and intrareader variabilities. High correspondence between the four phantoms created using the same patient images was demonstrated by PixelPrint's production repeatability tests, with greater similarity scores between high-dose acquisitions of the phantoms than between clinical-dose acquisitions of a single phantom. We demonstrated PixelPrint's ability to produce lifelike CT lung phantoms reliably. These phantoms have the potential to provide ground-truth targets for validating the generalizability of inference-based decision-support algorithms between different health centers and imaging protocols and for optimizing examination protocols with realistic patient-based phantoms. Classification: CT lung phantoms, reader study.

11.
Quant Imaging Med Surg ; 13(2): 924-934, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36819257

RESUMEN

Background: To determine the spectral accuracy in detector-based dual-energy CT (DECT) at 100 kVp and wide (8 cm) collimation width for dose levels and object sizes relevant to pediatric imaging. Methods: A spectral CT phantom containing tissue-equivalent materials and iodine inserts of varying concentrations was scanned on the latest generation detector-based DECT system. Two 3D-printed extension rings were used to mimic varying pediatric patient sizes. Scans were performed at 100 and 120 kVp, 4 and 8 cm collimation widths, and progressively reduced radiation dose levels, down to 0.9 mGy CTDIvol. Virtual mono-energetic, iodine density, effective atomic number, and electron density results were quantified and compared to their expected values for all acquisition settings and phantom sizes. Results: DECT scans at 100 kVp provided highly accurate spectral results; however, a size dependence was observed for iodine quantification. For the medium phantom configuration (15 cm diameter), measurement errors in iodine density, effective atomic number, and electron density (ED) were below 0.3 mg/mL, 0.2 and 1.8 %EDwater, respectively. The average accuracy was slightly different from scans at 120 kVp; however, not statistically significant for all configurations. Collimation width had no substantial impact. Spectral results were accurate and reliable for radiation exposures down to 0.9 mGy CTDIvol. Conclusions: Detector-based DECT at 100 kVp can provide on-demand or retrospective spectral information with high accuracy even at extremely low doses, thereby making it an attractive solution for pediatric imaging.

12.
J Cardiovasc Comput Tomogr ; 17(2): 146-163, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36253281

RESUMEN

Coronary computed tomography angiography (CTA) improves the quality of care for patients presenting with acute chest pain (ACP) to the emergency department (ED), particularly in patients with low to intermediate likelihood of acute coronary syndrome (ACS). The Society of Cardiovascular Computed Tomography Guidelines Committee was formed to develop recommendations for acquiring, interpreting, and reporting of coronary CTA to ensure appropriate, safe, and efficient use of this modality. Because of the increasing use of coronary CTA testing for the evaluation of ACP patients, the Committee has been charged with the development of the present document to assist physicians and technologists. These recommendations were produced as an educational tool for practitioners evaluating acute chest pain patients in the ED, in the interest of developing systematic standards of practice for coronary CTA based on the best available data or broad expert consensus. Due to the highly variable nature of medical care, approaches to patient selection, preparation, protocol selection, interpretation or reporting that differs from these guidelines may represent an appropriate variation based on a legitimate assessment of an individual patient's needs.


Asunto(s)
Angiografía por Tomografía Computarizada , Radiología , Humanos , Estados Unidos , Consenso , Valor Predictivo de las Pruebas , Dolor en el Pecho/diagnóstico por imagen , Dolor en el Pecho/etiología , Servicio de Urgencia en Hospital , Angiografía , América del Norte , Angiografía Coronaria/métodos
13.
Radiol Cardiothorac Imaging ; 5(6): e230131, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38166341

RESUMEN

Mitral annular disjunction (MAD) refers to atrial displacement of the hinge point of the mitral valve annulus from the ventricular myocardium. MAD leads to paradoxical expansion of the annulus in systole and may often be associated with mitral valve prolapse (MVP), leaflet degeneration, myocardial and papillary muscle fibrosis, and, potentially, malignant cardiac arrhythmias. Patients with MAD and MVP may present similarly, and MAD is potentially the missing link in explaining why some patients with MVP experience adverse outcomes. Patients with a 5 mm or longer MAD distance have an elevated risk of malignant cardiac arrhythmia compared with those with a shorter MAD distance. Evaluation for MAD is an important component of cardiac imaging, especially in patients with MVP and unexplained cardiac arrhythmias. Cardiac MRI is an important diagnostic tool that aids in recognizing and quantifying MAD, MVP, and fibrosis in the papillary muscle and myocardium, which may predict and help improve outcomes following electrophysiology procedures and mitral valve surgery. This article reviews the history, pathophysiology, controversy, prevalence, clinical implications, and imaging considerations of MAD, focusing on cardiac MRI. Keywords: MR-Dynamic Contrast Enhanced, Cardiac, Mitral Valve, Mitral Annular Disjunction, Mitral Valve Prolapse, Floppy Mitral Valve, Cardiac MRI, Arrhythmia, Sudden Cardiac Death, Barlow Valve © RSNA, 2023.


Asunto(s)
Prolapso de la Válvula Mitral , Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/diagnóstico por imagen , Arritmias Cardíacas/etiología , Músculos Papilares/diagnóstico por imagen , Fibrosis
14.
Artículo en Inglés | MEDLINE | ID: mdl-35664728

RESUMEN

Phantoms are essential tools for assessing and verifying performance in computed tomography (CT). Realistic patient-based lung phantoms that accurately represent textures and densities are essential in developing and evaluating novel CT hardware and software. This study introduces PixelPrint, a 3D-printing solution to create patient-specific lung phantoms with accurate contrast and textures. PixelPrint converts patient images directly into printer instructions, where density is modeled as the ratio of filament to voxel volume to emulate local attenuation values. For evaluation of PixelPrint, phantoms based on four COVID-19 pneumonia patients were manufactured and scanned with the original (clinical) CT scanners and protocols. Density and geometrical accuracies between phantom and patient images were evaluated for various anatomical features in the lung, and a radiomic feature comparison was performed for mild, moderate, and severe COVID-19 pneumonia patient-based phantoms. Qualitatively, CT images of the patient-based phantoms closely resemble the original CT images, both in texture and contrast levels, with clearly visible vascular and parenchymal structures. Regions-of-interest (ROIs) comparing attenuation demonstrated differences below 15 HU. Manual size measurements performed by an experienced thoracic radiologist revealed a high degree of geometrical correlation between identical patient and phantom features, with differences smaller than the intrinsic spatial resolution of the images. Radiomic feature analysis revealed high correspondence, with correlations of 0.95-0.99 between patient and phantom images. Our study demonstrates the feasibility of 3D-printed patient-based lung phantoms with accurate geometry, texture, and contrast that will enable protocol optimization, CT research and development advancements, and generation of ground-truth datasets for radiomic evaluations.

16.
Eur Radiol ; 32(12): 8579-8587, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35708838

RESUMEN

OBJECTIVE: Evaluation of image characteristics at ultra-low radiation dose levels of a first-generation dual-source photon-counting computed tomography (PCCT) compared to a dual-source dual-energy CT (DECT) scanner. METHODS: A multi-energy CT phantom was imaged with and without an extension ring on both scanners over a range of radiation dose levels (CTDIvol 0.4-15.0 mGy). Scans were performed in different modes of acquisition for PCCT with 120 kVp and DECT with 70/Sn150 kVp and 100/Sn150 kVp. Various tissue inserts were used to characterize the precision and repeatability of Hounsfield units (HUs) on virtual mono-energetic images between 40 and 190 keV. Image noise was additionally investigated at an ultra-low radiation dose to illustrate PCCT's ability to remove electronic background noise. RESULTS: Our results demonstrate the high precision of HU measurements for a wide range of inserts and radiation exposure levels with PCCT. We report high performance for both scanners across a wide range of radiation exposure levels, with PCCT outperforming at low exposures compared to DECT. PCCT scans at the lowest radiation exposures illustrate significant reduction in electronic background noise, with a mean percent reduction of 74% (p value ~ 10-8) compared to DECT 70/Sn150 kVp and 60% (p value ~ 10-6) compared to DECT 100/Sn150 kVp. CONCLUSIONS: This paper reports the first experiences with a clinical dual-source PCCT. PCCT provides reliable HUs without disruption from electronic background noise for a wide range of dose values. Diagnostic benefits are not only for quantification at an ultra-low dose but also for imaging of obese patients. KEY POINTS: PCCT scanners provide precise and reliable Hounsfield units at ultra-low dose levels. The influence of electronic background noise can be removed at ultra-low-dose acquisitions with PCCT. Both spectral platforms have high performance along a wide range of radiation exposure levels, with PCCT outperforming at low radiation exposures.


Asunto(s)
Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Dosis de Radiación , Fantasmas de Imagen
18.
Eur Heart J ; 43(26): 2496-2507, 2022 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-35139531

RESUMEN

AIMS: To evaluate the impact of a simplified, rapid cardiovascular magnetic resonance (CMR) protocol embedded in care and supported by a partner education programme on the management of cardiomyopathy (CMP) in low- and middle-income countries (LMICs). METHODS AND RESULTS: Rapid CMR focused particularly on CMP was implemented in 11 centres, 7 cities, 5 countries, and 3 continents linked to training courses for local professionals. Patients were followed up for 24 months to assess impact. The rate of subsequent adoption was tracked. Five CMR conferences were delivered (920 attendees-potential referrers, radiographers, reporting cardiologists, or radiologists) and five new centres starting CMR. Six hundred and one patients were scanned. Cardiovascular magnetic resonance indications were 24% non-contrast T2* scans [myocardial iron overload (MIO)] and 72% suspected/known cardiomyopathies (including ischaemic and viability). Ninety-eighty per cent of studies were of diagnostic quality. The average scan time was 22 ± 6 min (contrast) and 12 ± 4 min (non-contrast), a potential cost/throughput reduction of between 30 and 60%. Cardiovascular magnetic resonance findings impacted management in 62%, including a new diagnosis in 22% and MIO detected in 30% of non-contrast scans. Nine centres continued using rapid CMR 2 years later (typically 1-2 days per week, 30 min slots). CONCLUSIONS: Rapid CMR of diagnostic quality can be delivered using available technology in LMICs. When embedded in care and a training programme, costs are lower, care is improved, and services can be sustained over time.


Asunto(s)
Cardiomiopatías , Sobrecarga de Hierro , Cardiomiopatías/diagnóstico por imagen , Citidina Monofosfato , Países en Desarrollo , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Espectroscopía de Resonancia Magnética
20.
Magn Reson Med ; 87(1): 323-336, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34355815

RESUMEN

PURPOSE: Magnetic susceptibility (Δχ) alterations have shown association with myocardial infarction (MI) iron deposition, yet there remains limited understanding of the relationship between relaxation rates and susceptibility or the effect of magnetic field strength. Hence, Δχ and R2∗ in MI were compared at 3T and 7T. METHODS: Subacute MI was induced by coronary artery ligation in male Yorkshire swine. 3D multiecho gradient echo imaging was performed at 1-week postinfarction at 3T and 7T. Quantitative susceptibility mapping images were reconstructed using a morphology-enabled dipole inversion. R2∗ maps and quantitative susceptibility mapping were generated to assess the relationship between R2∗ , Δχ, and field strength. Infarct histopathology was investigated. RESULTS: Magnetic susceptibility was not significantly different across field strengths (7T: 126.8 ± 41.7 ppb; 3T: 110.2 ± 21.0 ppb, P = NS), unlike R2∗ (7T: 247.0 ± 14.8 Hz; 3T: 106.1 ± 6.5 Hz, P < .001). Additionally, infarct Δχ and R2∗ were significantly higher than remote myocardium. Magnetic susceptibility at 7T versus 3T had a significant association (ß = 1.02, R2 = 0.82, P < .001), as did R2∗ (ß = 2.35, R2 = 0.98, P < .001). Infarct pathophysiology and iron deposition were detected through histology and compared with imaging findings. CONCLUSION: R2∗ showed dependence and Δχ showed independence of field strength. Histology validated the presence of iron and supported imaging findings.


Asunto(s)
Imagen por Resonancia Magnética , Daño por Reperfusión Miocárdica , Animales , Hierro , Fenómenos Magnéticos , Magnetismo , Masculino , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Porcinos
SELECCIÓN DE REFERENCIAS