Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Quant Imaging Med Surg ; 13(12): 8094-8106, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38106274

RESUMEN

Background: Single-isocenter (SI) noncoplanar volumetric modulated arc therapy (NC-VMAT) has been widely used in stereotactic radiosurgery (SRS) or hypofractionated stereotactic radiotherapy (HSRT) for multiple brain metastases (BMs). However, it is critical to verify patient positioning at a noncoplanar couch angle. This study aimed to compare the noncoplanar setup discrepancies between kilo-voltage/mega-voltage image (kV/MV) orthogonal image pairs with a 2-dimensional/3-dimensional (2D/3D) matching mode and noncoplanar cone-beam computed tomography (NC-CBCT) with a 3D/3D matching mode in SI NC-VMAT HSRT for multiple BMs. Methods: Twenty patients with multiple BMs [2-5] who underwent SI NC-VMAT HSRT were enrolled in this study. Prior to each noncoplanar field delivery, both kV/MV orthogonal image pairs and NC-CBCT were used to determine setup errors. The setup error values reported by NC-CBCT were defined as the gold standard and compared to those reported by kV/MV orthogonal image pairs. The Bland-Altman analysis method was utilized to assess the agreement of the two positioning modalities. Results: In total, 104 kV/MV image pairs and NC-CBCT scans were acquired. The mean setup error differences (SEDs; absolute values) between the two positioning systems were 0.17 mm, 0.21 mm, 0.16 mm, 0.22°, 0.18°, and 0.17° in the vertical, longitudinal, lateral, yaw, pitch, and roll directions, respectively. The maximum SEDs regarding translation and rotation occurred in the longitudinal and yaw directions at 0.60 mm and 0.8°, respectively. Bland-Altman analysis showed excellent agreement between the two positioning modalities, and the 95% limits of agreement (LOAs) never exceeded 0.6 mm and 0.6° in the translational and rotational directions, respectively. Only 4.80% of SEDs exceeded the tolerance of 0.5 mm/0.5°. Conclusions: Orthogonal kV/MV image pairs with 2D/3D matching mode could provide comparable accuracy for noncoplanar positioning as NC-CBCT with 3D/3D matching mode.

2.
Nanoscale ; 15(19): 8854-8862, 2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-37114970

RESUMEN

Computational hyperspectral devices that use artificial filters have shown promise as compact spectral devices. However, the current designs are restricted by limited types and geometric parameters of unit cells, resulting in a high cross-correlation between the transmission spectra. This limitation prevents the fulfillment of the requirement for compressed-sensing-based spectral reconstruction. To address this challenge, we proposed and simulated a novel design for computational hyperspectral devices based on quasi-random metasurface supercells. The size of the quasi-random metasurface supercell was extended above the wavelength, which enables the exploration of a larger variety of symmetrical supercell structures. Consequently, more quasi-random supercells with lower polarization sensitivity and their spectra with low cross-correlation were obtained. Devices for narrowband spectral reconstruction and broadband hyperspectral single-shot imaging were designed and fabricated. Combined with the genetic algorithm with compressed sensing, the narrowband spectral reconstruction device reconstructs the complex narrowband hyperspectral signal with 6 nm spectral resolution and ultralow errors. The broadband hyperspectral device reconstructs a broadband hyperspectral image (λ/λ ∼ 0.001) with a high average signal fidelity of 92%. This device has the potential to be integrated into a complementary metal-oxide-semiconductor (CMOS) chip for single-shot imaging.

3.
Strahlenther Onkol ; 197(7): 592-600, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33725135

RESUMEN

BACKGROUND AND PURPOSE: Island blocking and dose leakage problems will lead to unnecessary irradiation to normal brain tissue (NBT) in hypofractionated stereotactic radiotherapy (HSRT) for multiple brain metastases (BM) with single-isocenter volumetric modulated arc therapy (VMAT). The present study aimed at investigating whether reducing the number of metastases irradiated by each arc beam could minimize these two problems. MATERIALS AND METHODS: A total of 32 non-small-cell lung cancer (NSCLC) patients with multiple BM received HSRT (24-36 Gy/3 fractions) with single-isocenter VMAT, where each arc beam only irradiated partial metastases (pm-VMAT), were enrolled in this retrospective study. Conventional single-isocenter VMAT plans, where each arc beam irradiated whole metastases (wm-VMAT), was regenerated and compared with pm-VMAT plans. Furthermore, the clinical efficacy and toxicities were evaluated. RESULTS: Pm-VMAT achieved similar target coverage as that with wm-VMAT, with better dose fall-off (P < 0.001) and NBT sparing (P < 0.001). However, pm-VMAT resulted in more monitor units (MU) and longer beam-on time (P < 0.001). The intracranial objective response rate and disease control rate for all patients were 75% and 100%, respectively. The local control rates at 1 year and 2 year were 96.2% and 60.2%, respectively. The median progression-free survival and overall survival were 10.3 months (95% confidence interval [CI] 6.8-13.2) and 18.5 months (95% CI 15.9-20.1), respectively. All treatment-related adverse events were grade 1 or 2, and 3 lesions (2.31%) from 2 patients (6.25%) demonstrated radiation necrosis after HSRT. CONCLUSION: HSRT with pm-VMAT is effective and has limited toxicities for NSCLC patients with multiple BM. Pm-VMAT could provide better NBT sparing while maintaining target dose coverage.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/patología , Neoplasias Pulmonares/patología , Hipofraccionamiento de la Dosis de Radiación , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos , Resultado del Tratamiento
4.
Langmuir ; 34(50): 15203-15210, 2018 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-30418030

RESUMEN

Abnormal rheological phenomena arising in Tris-borate-ethylenediaminetetraacetic acid solutions (believed to be Newtonian fluids) were observed in direct current electroosmotic flows within a nanocapillary with a diameter of 200 nm under a low electric field of tens of volts per meter. In solutions with different concentrations and pH values, the flow behavior indices of the power-law fluids were calculated on the basis of current-voltage relations. When the electric field intensity was below a critical value of 6.7 V/m, the fluids exhibited dilatant (shear thickening) effects. Fluid viscosity changed with electric field intensity because the near-wall shear rate of an electroosmotic flow changes with electric field intensity via a power-law relation. When the electric field intensity surpasses the critical electric field, the fluid again becomes Newtonian and has constant viscosity. The investigation shows that in nanocapillaries, fluids commonly believed to be Newtonian can become non-Newtonian near walls as a result of strong nanoscale interfacial effects. The results can also improve our understanding of electroosmosis-related transport phenomena in nanofluidics and biomedical science.

5.
Biomed Opt Express ; 8(12): 5651-5662, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29296494

RESUMEN

High-throughput imaging and screening is essential for biomedical research and drug discovery using miniature model organisms such as zebrafish. This study introduces a high-speed imaging system which illuminates zebrafish embryos flowing through a capillary tube with a sheet of light and captures them using a linear charge-coupled device (CCD). This system can image dozens of zebrafish embryos per second. An image algorithm was developed to recognize each embryo and to perform automatic analysis. We distinguished dead and living embryos according to the gray level distribution and conducted statistics of morphological characteristics of embryos at different growing stages.

6.
Biomicrofluidics ; 7(6): 61102, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24396534

RESUMEN

Plasmonic hot spots, generated by controlled 20-nm Au nanoparticle (NP) assembly, are shown to suppress fluorescent quenching effects of metal NPs, such that hair-pin FRET (Fluorescence resonance energy transfer) probes can achieve label-free ultra-sensitive quantification. The micron-sized assembly is a result of intense induced NP dipoles by focused electric fields through conic nanocapillaries. The efficient NP aggregate antenna and the voltage-tunable NP spacing for optimizing hot spot intensity endow ultra-sensitivity and large dynamic range (fM to pM). The large shear forces during assembly allow high selectivity (2-mismatch discrimination) and rapid detection (15 min) for a DNA mimic of microRNA.

9.
Phys Rev Lett ; 100(6): 067205, 2008 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-18352509

RESUMEN

We report the observation of a novel phenomenon, the self-retracting motion of graphite, in which tiny flakes of graphite, after being displaced to various suspended positions from islands of highly orientated pyrolytic graphite, retract back onto the islands under no external influences. Reports of this phenomenon have not been found in the literature for single crystals of any kind. Models that include the van der Waals force, electrostatic force, and shear strengths were considered to explain the observed phenomenon. These findings may conduce to create nanoelectromechanical systems with a wide range of mechanical frequency from megahertz to gigahertz.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...