Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
1.
Sci Rep ; 14(1): 17554, 2024 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-39080364

RESUMEN

Repositionable self-expanding valves allow for repositioning during deployment to achieve optimal valve placement. However, the risk of brain injury associated with repositioning, as detected by diffusion-weighted magnetic resonance imaging (DW-MRI), is unknown. Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with repositionable self-expanding valves and receiving DW-MRI before and within 7 days post-TAVR procedure were included. The primary outcomes were incidence, number, total volume, and volume per lesion of the cerebral ischemic lesion in DW-MRI after TAVR. Univariate and multivariate logistic regression assessed the association between repositioning and bigger total lesion volume (> 1 cm3 or > 0.5 cm3). Negative binomial regressions were performed to explore the association between repositioning and number of lesions. A propensity score matching was performed to adjust the potential confounders. Moreover, inverse probability of treatment weighted regression model with nonstabilized weights was used as sensitivity analysis. Among 243 included patients, repositioning was performed in 116 (47.7%) patients. The incidence of overt stroke (1.7% vs. 1.6%, p = 0.927) and silent stroke (86.2% vs. 85.8%, p = 0.932) were comparable between two groups. However, the number of new lesions (5.0 [2.0-9.0] vs. 3.0 [2.0-6.0], p = 0.048), and total lesion volume (275.0 [90.0-947.5] mm3 vs. 180.0 [50.0-440.0] mm3, p = 0.022) were significantly higher in the repositioned group. Moreover, the proportion of patients with lesion size greater than 0.5 cm3 was higher in the repositioned group (37.9% vs. 22.0%, p = 0.007). The similar results were observed after propensity score matching. In both multivariate regression model and sensitivity analysis, the repositioning was the independent predictor of number of lesions and bigger total lesion volume after TAVR. The utilization of the repositioning feature may increase the number and volume of silent brain infarcts in DW-MRI in patients who underwent TAVR. (Transcatheter Aortic Valve Replacement Single Center Registry in Chinese Population [TORCH]; NCT02803294).


Asunto(s)
Lesiones Encefálicas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/cirugía , Lesiones Encefálicas/etiología , Lesiones Encefálicas/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Prótesis Valvulares Cardíacas/efectos adversos , Incidencia , Factores de Riesgo , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
2.
J Med Internet Res ; 26: e41843, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39028996

RESUMEN

BACKGROUND: There are limited data available on the development of arrhythmias in patients at risk of high-degree atrioventricular block (HAVB) or complete heart block (CHB) following transcatheter aortic valve replacement (TAVR). OBJECTIVE: This study aimed to explore the incidence and evolution of arrhythmias by monitoring patients at risk of HAVB or CHB after TAVR using smartwatches. METHODS: We analyzed 188 consecutive patients in the prospective SMART TAVR (smartwatch-facilitated early discharge in patients undergoing TAVR) trial. Patients were divided into 2 groups according to the risk of HAVB or CHB. Patients were required to trigger a single-lead electrocardiogram (ECG) recording and send it to the Heart Health App via their smartphone. Physicians in the central ECG core lab would then analyze the ECG. The incidence and timing of arrhythmias and pacemaker implantation within a 30-day follow-up were compared. All arrhythmic events were adjudicated in a central ECG core lab. RESULTS: The mean age of the patients was 73.1 (SD 7.3) years, of whom 105 (55.9%) were men. The mean discharge day after TAVR was 2.0 (SD 1.8) days. There were no statistically significant changes in the evolution of atrial fibrillation or atrial flutter, Mobitz I, Mobitz II, and third-degree atrial ventricular block over time in the first month after TAVR. The incidence of the left bundle branch block (LBBB) increased in the first week and decreased in the subsequent 3 weeks significantly (P<.001). Patients at higher risk of HAVB or CHB received more pacemaker implantation after discharge (n=8, 9.6% vs n=2, 1.9%; P=.04). The incidence of LBBB was higher in the group with higher HAVB or CHB risk (n=47, 56.6% vs n=34, 32.4%; P=.001). The independent predictors for pacemaker implantation were age, baseline atrial fibrillation, baseline right bundle branch block, Mobitz II, and third-degree atrioventricular block detected by the smartwatch. CONCLUSIONS: Except for LBBB, no change in arrhythmias was observed over time in the first month after TAVR. A higher incidence of pacemaker implantation after discharge was observed in patients at risk of HAVB or CHB. However, Mobitz II and third-degree atrioventricular block detected by the smartwatch during follow-ups were more valuable indicators to predict pacemaker implantation after discharge from the index TAVR. TRIAL REGISTRATION: ClinicalTrials.gov NCT04454177; https://clinicaltrials.gov/study/NCT04454177.


Asunto(s)
Arritmias Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Estudios Prospectivos , Anciano de 80 o más Años , Electrocardiografía , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia
3.
Adv Sci (Weinh) ; : e2401527, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007192

RESUMEN

Myocardial Infarction (MI) is a leading cause of death worldwide. Metabolic modulation is a promising therapeutic approach to prevent adverse remodeling after MI. However, whether material-derived cues can treat MI through metabolic regulation is mainly unexplored. Herein, a Cu2+ loaded casein microgel (CuCMG) aiming to rescue the pathological intramyocardial metabolism for MI amelioration is developed. Cu2+ is an important ion factor involved in metabolic pathways, and intracardiac copper drain is observed after MI. It is thus speculated that intramyocardial supplementation of Cu2+ can rescue myocardial metabolism. Casein, a milk-derived protein, is screened out as Cu2+ carrier through molecular-docking based on Cu2+ loading capacity and accessibility. CuCMGs notably attenuate MI-induced cardiac dysfunction and maladaptive remodeling, accompanied by increased angiogenesis. The results from unbiased transcriptome profiling and oxidative phosphorylation analyses support the hypothesis that CuCMG prominently rescued the metabolic homeostasis of myocardium after MI. These findings enhance the understanding of the design and application of metabolic-modulating biomaterials for ischemic cardiomyopathy therapy.

4.
Artículo en Inglés | MEDLINE | ID: mdl-39049480

RESUMEN

Mitral regurgitation (MR) is the most common heart valve disease, and transcatheter edge-to-edge repair (TEER) has been recommended as a therapy for severe MR patients by guidelines. The classic Carpentier classification used to guide surgical mitral valve repair but is inadequate for mitral TEER (M-TEER). We herein proposed a new modified Carpentier classification named after "type + segment," which is suitable for M-TEER. We shared our strategies in M-TEER procedure for screening and performing the M-TEER according to the new modified Carpentier classification.

5.
Med Sci Monit ; 30: e943735, 2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39068511

RESUMEN

BACKGROUND Arthroscopic knee surgery (AKS) is minimally invasive, reducing hospital stay compared to traditional surgery, but postoperative pain remains a significant issue. This study compared the analgesic and functional outcomes following AKS following anesthesia using adductor canal block (ACB) with and without anesthesia using the interspace between the popliteal artery and posterior capsule of the knee (IPACK) block under spinal anesthesia (SA). MATERIAL AND METHODS We randomly allocated 120 patients into 3 groups: IPACK+ACB+SA for Group A (n=40), ACB+SA for Group B (n=40), and SA for Group C (n=40). The outcome was the visual analog scale (VAS) score evaluated at rest and during activity at 3 h, 6 h, 12 h, 24 h, and 48 h postoperatively, the frequency of administration of postoperative rescue analgesic, and the maximal walking distance at 24 h and 48 h postoperatively. RESULTS Compared with Group C, the VAS scores in Group A were significantly lower at 48 h postoperatively (P<0.05). There was a significant difference in the frequency of postoperative rescue analgesia use among the 3 groups (P=0.001). In a subgroup analysis of meniscus shaping under arthroscopy, the resting VAS score in Group A was lower than that in Group B and Group C at 48 h postoperatively (P<0.05). The maximum walking distance of Group A was longer than that of Group B and Group C at 24 h and 48 h postoperatively (P<0.01). CONCLUSIONS The effect of postoperative analgesia in the group receiving IPACK combined with ACB after AKS was obviously superior. In arthroscopic meniscus repair surgery, the duration of analgesia was longer, and the maximum walking distance at 48 h postoperatively was longer.


Asunto(s)
Artroscopía , Articulación de la Rodilla , Bloqueo Nervioso , Manejo del Dolor , Dimensión del Dolor , Dolor Postoperatorio , Humanos , Dolor Postoperatorio/tratamiento farmacológico , Artroscopía/métodos , Artroscopía/efectos adversos , Femenino , Masculino , Bloqueo Nervioso/métodos , Persona de Mediana Edad , Adulto , Manejo del Dolor/métodos , Articulación de la Rodilla/cirugía , Dimensión del Dolor/métodos , Resultado del Tratamiento
6.
Am Heart J ; 274: 65-74, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38701961

RESUMEN

BACKGROUND: There has not been a consensus on the prothesis sizing strategy in type 0 bicuspid aortic stenosis (AS) patients undergoing transcatheter aortic valve replacement (TAVR). Modifications to standard annular sizing strategies might be required due to the distinct anatomical characteristics. We have devised a downsizing strategy for TAVR using a self-expanding valve specifically for patients with type 0 bicuspid AS. The primary aim of this study is to compare the safety and efficacy of downsizing strategy with the Standard Annulus Sizing Strategy in TAVR for patients with type 0 bicuspid AS. TRIAL DESIGN: It is a prospective, multi-center, superiority, single-blinded, randomized controlled trial comparing the Down Sizing and Standard Annulus Sizing Strategy in patients with type 0 bicuspid aortic stenosis undergoing transcatheter aortic valve replacement. Eligible participants will include patients with severe type 0 bicuspid AS, as defined by criteria such as mean gradient across aortic valve ≥40 mmHg, peak aortic jet velocity ≥4.0 m/s, aortic valve area (AVA) ≤1.0 cm², or AVA index ≤0.6 cm2/m2. These patients will be randomly assigned, in a 1:1 ratio, to either the Down Sizing Strategy group or the Standard Sizing Strategy group. In the Down Sizing Strategy group, a valve one size smaller will be implanted if the "waist sign" manifests along with less than mild regurgitation during balloon pre-dilatation. The primary end point of the study is a composite of VARC-3 defined device success, absence of both permanent pacemaker implantation due to high-degree atrioventricular block and new-onset complete left bundle branch block. CONCLUSION: This study will compare the safety and efficacy of Down Sizing Strategy with the Standard Annulus Sizing Strategy and provide valuable insights into the optimal approach for sizing in TAVR patients with type 0 bicuspid AS. We hypothesize that the Down Sizing Strategy will demonstrate superiority when compared to the Standard Annulus Sizing Strategy. (Down Sizing Strategy (HANGZHOU Solution) vs Standard Sizing Strategy TAVR in Bicuspid Aortic Stenosis (Type 0) (TAILOR-TAVR), NCT05511792).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/complicaciones , Estudios Prospectivos , Método Simple Ciego , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Masculino , Femenino
7.
Insights Imaging ; 15(1): 125, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38816554

RESUMEN

OBJECTIVE: To observe prosthetic-associated subclinical thrombotic events (PASTE) after transcatheter aortic valve implantation (TAVI) by cardiac CTA, and assess their impact on long-term patient outcomes. MATERIALS: We prospectively and consecutively enrolled 188 patients with severe aortic stenosis treated with TAVI from February 2014 to April 2017. At 5 years, 61 of 141 survived patients who had completed annual follow-up CTA (≥ 5 years) were included. We analyzed PASTE by CTA, including hypoattenuated leaflet thickening (HALT), sinus filling defect (SFD), and prosthesis filling defect (PFD). The primary outcome was a major adverse cardiovascular composite outcome (MACCO) of stroke, cardiac re-hospitalization, and bioprosthetic valve dysfunction (BVD); the secondary outcomes were bioprosthetic hemodynamics deterioration (PGmean) and cardiac dysfunction (LVEF). RESULTS: During a median follow-up time of 5.25 years, long-term incidence of HALT, SFD, and PFD were 54.1%, 37.7%, and 73.8%, respectively. In the primary outcome, SFD and early SFD were associated with the MACCO (SFD: p = 0.005; early SFD: p = 0.018), and SFD was a predictor of MACCO (HR: 2.870; 95% CI: 1.010 to 8.154, p = 0.048). In the secondary outcomes, HALT was associated with increased PGmean (p = 0.031), while persistent HALT was correlated with ΔPGmean (ß = 0.38, p = 0.035). SFD was negatively correlated with ΔLVEF (ß = -0.39, p = 0.041), and early SFD was negatively correlated with LVEF and ΔLVEF (LVEF: r = -0.50, p = 0.041; ΔLVEF: r = -0.53, p = 0.030). CONCLUSIONS: PASTE were associated with adverse long-term outcomes, bioprosthetic hemodynamics deterioration, and cardiac dysfunction. In particular, SFD was a predictor of MACCO and may be a potential target for anticoagulation after TAVI (NCT02803294). REGISTRATION: URL: https://www. CLINICALTRIALS: gov ; Unique identifier: NCT02803294. CRITICAL RELEVANCE STATEMENT: PASTE, especially SFD, after TAVI based on cardiac CTA findings impacts the long-term outcomes of patients which is a predictor of long-term major adverse outcomes in patients and may be a potential target for anticoagulation after TAVI. KEY POINTS: Transcatheter aortic valve implantation is being used more often; associated subclinical thromboses have not been thoroughly evaluated. Prosthetic-associated subclinical thrombotic events were associated with adverse outcomes, bioprosthetic hemodynamics deterioration, and cardiac dysfunction. Studies should be directed at these topics to determine if they should be intervened upon.

8.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38419402

RESUMEN

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Pulmonar , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Asia , Catéteres
9.
Animal Model Exp Med ; 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38372410

RESUMEN

BACKGROUND: Calcific aortic valve stenosis (CAVS) is one of the most challenging heart diseases in clinical with rapidly increasing prevalence. However, study of the mechanism and treatment of CAVS is hampered by the lack of suitable, robust and efficient models that develop hemodynamically significant stenosis and typical calcium deposition. Here, we aim to establish a mouse model to mimic the development and features of CAVS. METHODS: The model was established via aortic valve wire injury (AVWI) combined with vitamin D subcutaneous injected in wild type C57/BL6 mice. Serial transthoracic echocardiography was applied to evaluate aortic jet peak velocity and mean gradient. Histopathological specimens were collected and examined in respect of valve thickening, calcium deposition, collagen accumulation, osteogenic differentiation and inflammation. RESULTS: Serial transthoracic echocardiography revealed that aortic jet peak velocity and mean gradient increased from 7 days post model establishment in a time dependent manner and tended to be stable at 28 days. Compared with the sham group, simple AVWI or the vitamin D group, the hybrid model group showed typical pathological features of CAVS, including hemodynamic alterations, increased aortic valve thickening, calcium deposition, collagen accumulation at 28 days. In addition, osteogenic differentiation, fibrosis and inflammation, which play critical roles in the development of CAVS, were observed in the hybrid model. CONCLUSIONS: We established a novel mouse model of CAVS that could be induced efficiently, robustly and economically, and without genetic intervention. It provides a fast track to explore the underlying mechanisms of CAVS and to identify more effective pharmacological targets.

10.
EuroIntervention ; 20(4): e239-e249, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38389469

RESUMEN

BACKGROUND: Severe degenerative mitral regurgitation (DMR) can cause a poor prognosis if left untreated. For patients considered at prohibitive surgical risk, transcatheter edge-to-edge repair (TEER) has become an accepted alternative therapy. The DragonFly transcatheter valve repair system is an innovative evolution of the mitral TEER device family to treat DMR. AIMS: Herein we report on the DRAGONFLY-DMR trial (ClinicalTrials.gov: NCT04734756), which was a prospective, single-arm, multicentre study on the safety and effectiveness of the DragonFly system. METHODS: A total of 120 eligible patients with prohibitive surgical risk and DMR ≥3+ were screened by a central eligibility committee for enrolment. The study utilised an independent echocardiography core laboratory and clinical event committee. The primary endpoint was the clinical success rate, which measured freedom from all-cause mortality, mitral valve reintervention, and mitral regurgitation (MR) >2+ at 1-year follow-up. RESULTS: At 1 year, the trial successfully achieved its prespecified primary efficacy endpoint, with a clinical success rate of 87.5% (95% confidence interval: 80.1-92.3%). The rates of major adverse events, all-cause mortality, mitral valve reintervention, and heart failure hospitalisation were 9.0%, 5.0%, 0.8%, and 3.4%, respectively. MR ≤2+ was 90.4% at 1 month and 92.0% at 1 year. Over time, left ventricular reverse remodelling was observed (p<0.05), along with significant improvements in the patients' functional and quality-of-life outcomes, shown by an increase in the New York Heart Association Class I/II from 32.4% at baseline to 93.6% at 12 months (p<0.001) and increased Kansas City Cardiomyopathy Questionnaire (KCCQ) score of 31.1±18.2 from baseline to 12 months (p<0.001). CONCLUSIONS: The DRAGONFLY-DMR trial contributes to increasing evidence supporting the safety and efficacy of TEER therapy, specifically the DragonFly system, for treating patients with chronic symptomatic DMR 3+ to 4+ at prohibitive surgical risk.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
11.
Nat Commun ; 15(1): 557, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38228638

RESUMEN

Calcific aortic valve disease is a prevalent cardiovascular disease with no available drugs capable of effectively preventing its progression. Hence, an efficient drug delivery system could serve as a valuable tool in drug screening and potentially enhance therapeutic efficacy. However, due to the rapid blood flow rate associated with aortic valve stenosis and the lack of specific markers, achieving targeted drug delivery for calcific aortic valve disease has proved to be challenging. Here we find that protease-activated-receptor 2 (PAR2) expression is up-regulated on the plasma membrane of osteogenically differentiated valvular interstitial cells. Accordingly, we develop a magnetic nanocarrier functionalized with PAR2-targeting hexapeptide for dual-active targeting drug delivery. We show that the nanocarriers effectively deliver XCT790-an anti-calcification drug-to the calcified aortic valve under extra magnetic field navigation. We demonstrate that the nano-cargoes consequently inhibit the osteogenic differentiation of valvular interstitial cells, and alleviate aortic valve calcification and stenosis in a high-fat diet-fed low-density lipoprotein receptor-deficient (Ldlr-/-) mouse model. This work combining PAR2- and magnetic-targeting presents an effective targeted drug delivery system for treating calcific aortic valve disease in a murine model, promising future clinical translation.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Ratones , Animales , Válvula Aórtica/metabolismo , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Osteogénesis , Calcinosis/tratamiento farmacológico , Calcinosis/metabolismo , Células Cultivadas , Fenómenos Magnéticos
12.
Circulation ; 149(8): 605-626, 2024 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-38018454

RESUMEN

BACKGROUND: A better understanding of the molecular mechanism of aortic valve development and bicuspid aortic valve (BAV) formation would significantly improve and optimize the therapeutic strategy for BAV treatment. Over the past decade, the genes involved in aortic valve development and BAV formation have been increasingly recognized. On the other hand, ADAMTS (a disintegrin and metalloproteinase with thrombospondin motifs) gene family members have been reported to be able to modulate cardiovascular development and diseases. The present study aimed to further investigate the roles of ADAMTS family members in aortic valve development and BAV formation. METHODS: Morpholino-based ADAMTS family gene-targeted screening for zebrafish heart outflow tract phenotypes combined with DNA sequencing in a 304 cohort BAV patient registry study was initially carried out to identify potentially related genes. Both ADAMTS gene-specific fluorescence in situ hybridization assay and genetic tracing experiments were performed to evaluate the expression pattern in the aortic valve. Accordingly, related genetic mouse models (both knockout and knockin) were generated using the CRISPR/Cas9 (clustered regularly interspaced short palindromic repeats/clustered regularly interspaced short palindromic repeat-associated 9) method to further study the roles of ADAMTS family genes. The lineage-tracing technique was used again to evaluate how the cellular activity of specific progenitor cells was regulated by ADAMTS genes. Bulk RNA sequencing was used to investigate the signaling pathways involved. Inducible pluripotent stem cells derived from both BAV patients and genetic mouse tissue were used to study the molecular mechanism of ADAMTS. Immunohistochemistry was performed to examine the phenotype of cardiac valve anomalies, especially in the extracellular matrix components. RESULTS: ADAMTS genes targeting and phenotype screening in zebrafish and targeted DNA sequencing on a cohort of patients with BAV identified ADAMTS16 (a disintegrin and metalloproteinase with thrombospondin motifs 16) as a BAV-causing gene and found the ADAMTS16 p. H357Q variant in an inherited BAV family. Both in situ hybridization and genetic tracing studies described a unique spatiotemporal pattern of ADAMTS16 expression during aortic valve development. Adamts16+/- and Adamts16+/H355Q mouse models both exhibited a right coronary cusp-noncoronary cusp fusion-type BAV phenotype, with progressive aortic valve thickening associated with raphe formation (fusion of the commissure). Further, ADAMTS16 deficiency in Tie2 lineage cells recapitulated the BAV phenotype. This was confirmed in lineage-tracing mouse models in which Adamts16 deficiency affected endothelial and second heart field cells, not the neural crest cells. Accordingly, the changes were mainly detected in the noncoronary and right coronary leaflets. Bulk RNA sequencing using inducible pluripotent stem cells-derived endothelial cells and genetic mouse embryonic heart tissue unveiled enhanced FAK (focal adhesion kinase) signaling, which was accompanied by elevated fibronectin levels. Both in vitro inducible pluripotent stem cells-derived endothelial cells culture and ex vivo embryonic outflow tract explant studies validated the altered FAK signaling. CONCLUSIONS: Our present study identified a novel BAV-causing ADAMTS16 p. H357Q variant. ADAMTS16 deficiency led to BAV formation.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Cardiopatías Congénitas , Enfermedades de las Válvulas Cardíacas , Humanos , Animales , Ratones , Pez Cebra/genética , Enfermedades de las Válvulas Cardíacas/metabolismo , Células Endoteliales/metabolismo , Desintegrinas/genética , Desintegrinas/metabolismo , Hibridación Fluorescente in Situ , Válvula Aórtica/metabolismo , Cardiopatías Congénitas/complicaciones , Matriz Extracelular/metabolismo , Trombospondinas/metabolismo , Metaloproteasas/metabolismo , Proteínas ADAMTS/genética , Proteínas ADAMTS/metabolismo
13.
Circ Cardiovasc Qual Outcomes ; 17(1): e010066, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38088154

RESUMEN

BACKGROUND: This study aims to evaluate limited data about daily physical activity patterns, influential factors, and their association with 1-year mortality or rehospitalization after transcatheter aortic valve replacement (TAVR) through smartwatches. METHODS: Consecutive severe aortic stenosis patients undergoing elective transfemoral TAVR in a Chinese tertiary hospital were enrolled from July 2021 to May 2022 and received a Huawei smartwatch at least 1 day before TAVR. The primary outcome was a composite of all-cause mortality or hospital readmission within 1 year. Linear mixed-effects models were applied to determine influential factors of daily step counts, and Cox proportional hazard regression models were to estimate the association between baseline step counts within 1 month since discharge and composite outcome from months 2 to 12. The dose-response association was assessed using restricted cubic spline curves. RESULTS: A total of 222 participants and 59 469 valid monitoring person-day records were included (mean age, 72.7 years; 61% women). Step counts increased rapidly within the first 2 months (P<0.001), followed by a slower increase for those without composite outcomes (P=0.029) and a gradual decrease for those who developed composite outcomes (P<0.001). In multivariate linear mixed models, a 1-m increase in baseline 6-minute walk test and a 1-month delay after discharge were associated with 4 (95% CI, 1-7) and 170 (95% CI, 145-194) additional step counts, respectively. In restricted cubic spline analysis, the hazard ratio declined progressively until ≈5000 steps per day, after which they leveled. Below 5000 steps, the adjusted hazard ratio of composite outcome associated with each 1000-step count increase was 0.67 (0.50-0.89; P=0.007). However, above 5000 steps, step counts were not significantly associated with the composite outcome (P=0.645), with a hazard ratio of 1.12 (0.70-1.79). CONCLUSIONS: Daily step counts rapidly increased within the first 2 months post-TAVR. Increased physical activity was associated with a lower risk of 1-year mortality or rehospitalization after TAVR for patients with daily step counts below 5000. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04454177.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos Electrónicos Vestibles , Humanos , Femenino , Anciano , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Ejercicio Físico , Válvula Aórtica/cirugía , Factores de Riesgo , Índice de Severidad de la Enfermedad
17.
Front Cardiovasc Med ; 10: 1064255, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37383702

RESUMEN

Background: Data on outcomes following transcatheter aortic valve replacement with SAPIEN 3 in China is limited as it was approved by the National Medical Products since 2020. The present study was designed to collect clinical data on the SAPIEN 3 aortic valve in Chinese patients with bicuspid aortic valve and tricuspid aortic valve stenosis. Methods: We analyzed the patient characteristics, procedural features and procedural outcomes of the first 438 patients (223 for bicuspid aortic valve and 215 tricuspid aortic valve) from 21 provinces in 74 sites treated with the SAPIEN 3 valve system for transcatheter aortic valve replacement between September 2020 and May 2022. Results: Procedural mortality was 0.7%. 5 cases during the operation were converted to surgery. Among 438 cases, permanent pacemaker implantation was performed in a total of 12 cases (2.7%). The patient had severe leaflet calcification of the aortic valve, with moderate and severe calcification reaching 39.7% and 35.2% respectively. The size of the implanted valves was predominantly 26 mm and 23 mm, reaching 42.5% and 39.5% respectively. The incidence of moderate or severe perivalvular leak in the postoperative period was 0.5%, with a predominance of 90/10 and 80/20 valve deployment height. There was a significant difference in the deployment height of the valve between bicuspid aortic valve and tricuspid aortic valve, with the bicuspid aortic valve having a more deployment height of 90/10. Annulus size in bicuspid aortic valve group was significantly larger than tricuspid aortic valve group. Valve sizing for oversized, within size, and undersized were different between bicuspid aortic valve and tricuspid aortic valve. Conclusions: Procedural success rates were high, with similar and good results for bicuspid aortic valve and tricuspid aortic valve, low perivalvular leak for both valve types, and low permanent pacemaker implantation rates for both valve types. Annulus size, valve sizing and coronary artery height were significantly different in the BAV and TAV group.

18.
J Zhejiang Univ Sci B ; 24(6): 530-538, 2023 Jun 15.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-37309044

RESUMEN

Considering the surgical risk stratification for patients with severe calcific aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) is a reliable alternative to surgical aortic valve replacement (SAVR) (Fan et al., 2020, 2021; Lee et al., 2021). Despite the favorable clinical benefits of TAVR, stroke remains a dreaded perioperative complication (Auffret et al., 2016; Kapadia et al., 2016; Kleiman et al., 2016; Huded et al., 2019). Ischemic overt stroke, identified in 1.4% to 4.3% of patients in TAVR clinical practice, has been associated with prolonged disability and increased mortality (Auffret et al., 2016; Kapadia et al., 2016; Levi et al., 2022). The prevalence of hyperintensity cerebral ischemic lesions detected by diffusion-weighted magnetic resonance imaging (DW-MRI) was reported to be about 80%, which is associated with impaired neurocognitive function and vascular dementia (Vermeer et al., 2003; Barber et al., 2008; Kahlert et al., 2010).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Imagen de Difusión por Resonancia Magnética
19.
ACS Nano ; 17(13): 12072-12086, 2023 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-37363813

RESUMEN

Tissue engineering raised a high requirement to control cell distribution in defined materials and structures. In "ink"-based bioprintings, such as 3D printing and photolithography, cells were associated with inks for spatial orientation; the conditions suitable for one ink are hard to apply on other inks, which increases the obstacle in their universalization. The Magneto-Archimedes effect based (Mag-Arch) strategy can modulate cell locomotion directly without impelling inks. In a paramagnetic medium, cells were repelled from high magnetic strength zones due to their innate diamagnetism, which is independent of substrate properties. However, Mag-Arch has not been developed into a powerful bioprinting strategy as its precision, complexity, and throughput are limited by magnetic field distribution. By controlling the paramagnetic reagent concentration in the medium and the gaps between magnets, which decide the cell repelling scope of magnets, we created simultaneously more than a hundred micrometer scale identical assemblies into designed patterns (such as alphabets) with single/multiple cell types. Cell patterning models for cell migration and immune cell adhesion studies were conveniently created by Mag-Arch. As a proof of concept, we patterned a tumor/endothelial coculture model within a covered microfluidic channel to mimic epithelial-mesenchymal transition (EMT) under shear stress in a cancer pathological environment, which gave a potential solution to pattern multiple cell types in a confined space without any premodification. Overall, our Mag-Arch patterning presents an alternative strategy for the biofabrication and biohybrid assembly of cells with biomaterials featured in controlled distribution and organization, which can be broadly employed in tissue engineering, regenerative medicine, and cell biology research.


Asunto(s)
Técnicas de Cultivo de Célula , Tinta , Ingeniería de Tejidos/métodos , Comunicación Celular , Técnicas Analíticas Microfluídicas , Técnicas de Cocultivo , Movimiento Celular , Magnetismo , Humanos , Técnicas de Cultivo de Célula/métodos
20.
Int J Cardiol ; 386: 30-36, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37178802

RESUMEN

BACKGROUND: There is little evidence of evolution in cardiac damage after transcatheter aortic valve replacement (TAVR) in aortic stenosis (AS) patients. Less is known about the prognostic value and potential utility of different cardiac damage trajectories following TAVR. OBJECTIVES: This study aims to investigate the cardiac damage trajectories following TAVR and explore their association with subsequent clinical outcomes. METHODS: AS patients undergoing TAVR were enrolled and classified into five cardiac damage stages (0-4) based on the echocardiographic staging classification retrospectively. They were further grouped into early stage (stage 0-2) and advanced stage (stage 3-4). The cardiac damage trajectories in TAVR recipients were evaluated according to their trend between baseline and 30 days after TAVR. RESULTS: A total of 644 TAVR recipients were enrolled, with four distinct trajectories identified. Compared to patients with early-early trajectory, patients with early-advanced trajectory were at 30-fold risk of all-cause death (HR 30.99, 95% CI 13.80-69.56; p < 0.001). In multivariable analyses, early-advanced trajectory was associated with higher 2-year all-cause death (HR 24.08, 95% CI 9.07-63.90; p < 0.001), cardiac death (HR 19.34, 95% CI 3.06-122.34; p < 0.05), and cardiac rehospitalization (HR 4.19, 95% CI 1.49-11.76; p < 0.05) after TAVR. CONCLUSIONS: This investigation provided insight into four cardiac damage trajectories in TAVR recipients and confirmed the prognostic value of distinct trajectories. Early-advanced trajectory was associated with poor clinical prognosis following TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos , Corazón , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA